How to connect Higher current Rating module with small capacity of inverter ?

Поділитися
Вставка
  • Опубліковано 29 сер 2024
  • How to connect Higher current Rating
    module with small capacity of inverter ? || अब हाई करंट के पैनल भी लगेंगे छोटे इनवर्टर पर |
    #havells #canadiansolar
    #Module compatibility #highercurrentmodule
    Solarinverter #solarpanel #stringdesign #stringdeignofhighercurrentmodule
    Solar
    Safest
    Smarter
    Saur urja
    Biljli Kaise bachaye
    Solar se Bijli Kaise Bachaye
    Benefits of Installing solar
    Profitable solar
    Solar k Fayede
    Solar Lagane k Fayade
    MCB
    MCCB
    ACB
    AJB
    ACDB
    DCDB
    Lighting Arrester
    walkway
    cable Tray
    Solar Panel
    Solar Inverter
    Solar Cable
    AC Cable
    Follow me on -
    Telegram- t.me/+uVOzUWjD...
    LinkedIn- / raman-kumar-666436141
    Facebook - / solarfacts-37057195372...
    solar structures
    Solar panel mounting structure
    Solar mounting structure
    acdb and dcdb for solar system
    acdb box price
    dcdb box for solar system
    dcdb box price
    long rail solar structure
    mini rail for solar panels
    mini rail solar structure
    solar mounting structures
    solar panel structure
    solar structure
    solar structure types
    types of mounting structures for solar panels
    types of solar mounting structure
    types of solar structure
    mounting structure for solar panels
    mono rail solar structure
    solar acdb box
    solar acdb dcdb box
    solar dcdb box
    solar mini rail
    standing seam solar structure
    tilted solar structure
    acdb box for solar
    dcdb box for solar
    Video link -
    1. How solar zero export works.- lnkd.in/evPgfuj2
    2. What is Enphase microinverter ? // Microinverter & it’s step wise installation explanation. - lnkd.in/e3mr7HjF
    3. Concept of Solar Inverter Overloading //Solar inveter overloading is right or wrong !!!! - lnkd.in/eDNXTc2z
    4. What is Reactive Power ? // Why Industries Power Factory become poor after installing Solar! - lnkd.in/ei8S_d_m
    5. What is CT? What is CT Ratio? How to select CT? - lnkd.in/eCkNRTtZ
    6. How to check Current Transformers? - lnkd.in/eT5gc99e
    7. Why Solar Systems are not Success with Zero Export device. // Precautionary Majors for Zero Export. - • Why Solar Systems are ...
    8. How to design SolarEdge string // How to use SolarEdge string designing tool. - • How to design SolarEdg...
    9. How to install solar panel // What is the right way to install solar panel. - • How to install solar p...
    10. How to calculate string design for solar Inverter? -- lnkd.in/ekujjSpm
    11. How to design stand alone solar system & Battery bank capacity - lnkd.in/exEYzYdD
    12. What is surge protection device? // How to protect our system from surge? - • What is Surge Protecti...
    13. What is Armoured cable? // what is the benefits of Armoured cable?- • What is Armoured cable...
    14. Why Single Core Cable Comes with AL Armoured not with Steel? -- • Why Single Core Cable ...
    15. How To Calculate Neutral Current? 3 Phase Neutral Current Calculation! Unbalance current calculation! - • How To Calculate Neutr...
    16. What is Neutral Floating? // Why voltage increase // what happen if neutral breaks in a transformer. - • Video
    17. Solar Power Plant Shadow Analysis ! // Shadow Calculations for Row Spacing.
    • Solar Power Plant Shad...
    18. What is 1000VDC and 1500VDC solar system.// Advantage and Disadvantage of 1500VDC Solar System - • What is 1000VDC and 15...
    19. What is Netmetering and What is Gross metering. // Netmetering and Gross metering billing method. -- • What is Netmetering an...
    20. What is PID (Potential Induced Degradation) ? Why PID Occurs in Solar Panel ? / How to check PID ? -- • What is PID (Potential...
    21. How to select solar panel on technical basis ? // Best solar panel selection as per project. -- • How to select solar pa...
    22. What Is Solar PERC Technology? // Mono PERC // Poly PERC. // Passivated Emitter and Rear Contact -- • What Is Solar PERC Tec...
    23. How to Calculate size of Earting Conductor and Earthing Electrodes? // Earthing Calculation. -- • How to Calculate size ...
    24. How Mismatch affect Solar Plant Generation?What are the causes of Mismatch losses ? -- • How Mismatch affect So...
    25. Why Solar Energy Consume First ? // How Import and Export Works in Solar system ? -- • Why Solar Energy Consu...
    26. What is P-Type and N-Type Semiconductor? // How Solar Cell Works? -- lnkd.in/e6Ydxc2P
    27. Design your Solar Plant On your Own /Battery Selection and Sizing Calculation /Battery Calculation. -- • Design your Solar Plan...
    28. How Lithium-Ion Batteries Are Cheaper Than Lead Acid? // C Rating of Battery // C-10, C-20 and C-5. -- • How Lithium-Ion Batter...
    29. Comparison between string inverters vs micro inverter // Benefits of micro inverter. -- • Comparison between str...
    L
    For more information contact us 😊.
    Name - Raman Kumar
    Contact No- 9871073342

КОМЕНТАРІ • 50

  • @technopower1298
    @technopower1298 2 роки тому +1

    Good work sir , i too was designing 5kw with cs and finding the same issue, but now its all clear all thanks to you.

  • @Amazingsolar7753
    @Amazingsolar7753 2 роки тому +1

    Very informative video

  • @neutral6778
    @neutral6778 2 роки тому +1

    Very informative sir

  • @sourabhsharma9985
    @sourabhsharma9985 2 роки тому +1

    Love to see that how basic KCL can solve the bigger problem,very nice vedio sir.

  • @sathyaprasad1411
    @sathyaprasad1411 5 місяців тому

    ,,👌👌👌👏👏👏👍👍👍👍

  • @ramdhaniyadav2338
    @ramdhaniyadav2338 2 роки тому +1

    Very well explained!!
    Thank you🙏🙏

  • @amardeepsingh1984
    @amardeepsingh1984 2 роки тому +1

    well explained

  • @siddharthsrinet9022
    @siddharthsrinet9022 2 роки тому +1

    👍👍👍👍

  • @harikrishnankr9150
    @harikrishnankr9150 2 роки тому +1

    😍😍

  • @user-bj6eo2ke9x
    @user-bj6eo2ke9x Рік тому +1

    Hello sir. Good Explanation. But if MC4 burn or damage of any positive or negative end will cause a dangerous situation for the inverter at peak load. Isn't it? Please explain

    • @solarfacts4242
      @solarfacts4242  11 місяців тому

      Actually in this case both the MPPT Are working parallel it’s not working individually

  • @pgmakwana
    @pgmakwana Рік тому +1

    Sir jo baord pe write karke rakhte ho vo value Barbara dikhti nahi he so write big so we under stand better

    • @solarfacts4242
      @solarfacts4242  Рік тому

      Please rotate your phone
      I am sure it will be visible

  • @hb1605
    @hb1605 13 днів тому

    Sir please suggest me good on grid 1 phase inverter for adani TOPCcon 570wh (I am confused in Havells or Polycab)

  • @gnaneshwarsamal7176
    @gnaneshwarsamal7176 2 роки тому +1

    if you are using 2 MMPT means than you can select parallel operation mode

  • @pramodshah1830
    @pramodshah1830 8 місяців тому

    Mere question hai ki. Mppt agar ak hai inverter me 100kw le delta me. Or usme 8 string de rahe hai smb me each having 16 amp. How will mppt work than. Multiple string but only 1 mppt in imverter?

  • @utkarsh329
    @utkarsh329 Рік тому +1

    but in Y-connector case only one string making then this will not make use of 2 MPPT (if shadow on 1 panel then whole system down)

  • @siddharthsrinet9022
    @siddharthsrinet9022 2 роки тому +1

    Bhai kabhi transformer less aur transformer wale inverter me diffrence wala vedio banao

  • @saifsyedmohammad3769
    @saifsyedmohammad3769 Рік тому +1

    I have 15 panels of 335 W panels in series with a total voltage of 520V. My inverter supports 1000V Voc. I have a 550 W panel with a slightly higher current rating lying around. Can I connect this single panel in series will all other 15 panels ?

    • @solarfacts4242
      @solarfacts4242  Рік тому

      You can but due to miss match your 550 watt panel will also work as a 335 watt panel

  • @saifsyedmohammad3769
    @saifsyedmohammad3769 Рік тому +1

    Help Please !I have 15 panels of 335 W panels in series with a total voltage of 520V. My inverter supports 1000V Voc. I have a 550 W panel with a slightly higher current rating lying around. Can I connect this single panel in series will all other 15 panels ?

    • @solarfacts4242
      @solarfacts4242  Рік тому

      You can but due to miss match your 550 watt panel will also work as a 335 watt panel

  • @mohanmachinerymart4551
    @mohanmachinerymart4551 2 роки тому +1

    hello sir yeh parallel mode har invertor mai hota hai

  • @MR_SOLAR_BABA
    @MR_SOLAR_BABA 2 роки тому +2

    It is dangerous practice, suppose one mppt stops working connector may burn or damaged to the inverter.

    • @solarfacts4242
      @solarfacts4242  11 місяців тому +1

      Sir actually both tha MPPT is working in parallel mode if there is any problem with one MPPT both will not work

    • @solarfacts4242
      @solarfacts4242  11 місяців тому +1

      So there is no problem

  • @ptkgupta
    @ptkgupta 2 роки тому

    Problem: 540Wp/IMP: 12.9A
    Using Y connectors, we
    We are unable to overload the inverter as only 1 string can be connected per MPPT. Any suggestions. Can you suggest some good inverters with 30A+ MPPTs in 50 to 100KW range.

    • @solarfacts4242
      @solarfacts4242  2 роки тому

      for 50 and 100 Kw you can get high rating of MPPT

  • @karkar5360
    @karkar5360 11 місяців тому +1

    The 17 amp will not divide into as you said.8.5 +8.5 by Y connectors
    You are wrong make it correct .

    • @solarfacts4242
      @solarfacts4242  11 місяців тому

      Sorry but in this case both the mppt will work in parallel mode and equal amount of current will flow

  • @yasirkazi9703
    @yasirkazi9703 2 роки тому +1

    Can you please confirm that the current through the y connector gets divided equally?
    Also, does the inverter manufacturer allow us to use this? Technically it looks feasible.
    But the manufacturer should also approve it so that it helps in case of claiming warranty.

  • @poorvadityainfrasolutions5186
    @poorvadityainfrasolutions5186 Рік тому +1

    How to connect if inverter have only single mppt

  • @CoolDude-vc2fl
    @CoolDude-vc2fl Місяць тому

    MPPT can not share a string.

    • @solarfacts4242
      @solarfacts4242  Місяць тому

      It can and I have done at multiple sites

  • @sachinwadje3948
    @sachinwadje3948 2 роки тому

    Not agreed with last point explain by you at evening or in morning voltage not get affected only current generation is lower
    So in case of renewsys 400wp module we can used two separate string
    Benefit of using two separate string is in case of failure of other string at least half generation is continue
    other thing nicely explain by you