This Could Have Killed Someone! - A Day In The Life Of A Gas Engineer 179
Вставка
- Опубліковано 5 жов 2024
- Powered Now - Job Management Software
www.powerednow...
Unilite IL-925R
unilite.co.uk/...
unilite.co.uk/...
Use code UNCLE for 25% off
velocityprogea...
This installation could have killed someone! How do people get away with stuff like this?
Hope you enjoy the video!
As always, thank you all for supporting the channel, I appreciate it!
#plumbing #heating #boiler
towel radiator
vaillant
ufh
underfloor heating
blockage
magnetite
scale
lockshield
radiator valves
electric
boiler
electrical
wiring
What's the most dangerous job you've done across?? Don't forget to hit the LIKE & SUBSCRIBE buttons 👊🏾
Top vid Broski. I had two weeks off recently, back to work and the trusty transit van died on me, what an absolute f-on changing vans racking etc, easier moving homes.
Ah no way!! What happened to it? What's the new workhorse then?
Well..... the Friday before my two weeks rest I collected her from the garage after an Mot and Service. She sat on the drive two weeks, fired her up for work and it started leaking oil, followed by smoke, a lot of smoke, Greta would of had a heart attack. She was a 2010 Swb Transit, needed replaced to be honest so got a 22 transit L2 H2, massive but I can see my van floor now which is welcomed changed of events ha.
@@delboy6384 everything happens for a reason! Glad to hear you're back on the road! 🙌🏾
@@cputilitysolutions yep nothing worse than being stopped from graft, convid didn't stop me either haha
I found a vaillant ecotec once with flue in a void it was approximately 8 meters long and had fully rusted through most of the way along it. It was one of the worst installed flues I had ever seen. At the time boiler was 6 years old. But it was used 24/7 replaced the whole thing 🎉
Wow that sounds like a bad one!!
@@cputilitysolutions single lipped vaillant flue seals are total crap
💯 I've gotta change a turret & flue seal on one tomorrow 😅
nice one! Im literally going through the chimney / flues section of my gas training so this is great. I hope you let HSE know about this! Definitely should riddor this! ID!!!!!!
I think the customer is taking it on, shocking find!
Found same with these aswell - not connected properly!! Had to change some of the new vaillant energy R rear exit flues too cuz they're not long enough, cant see any white of the flue on inside of boiler or the screws ya shud see!! 🤷♀️🙌
Well spotted lad!!
Ah I've had to take the boiler off the wall to change a rear flue seal on an Ecosh!t 🤦🏾♂️
Thank you
You're welcome 👍🏾
Hell fire that gas flue installation was appalling and as you say highly dangerous. Am not a techie, wondered if you check for negative polarity to protect yourself? Saw YT vid where sparky called in due to eratic behaviour think of the led lights and found when meter been changed for smart the + - tails got reversed going into the Henley block.
Oh damn! I do carry out safe isolation and polarity checks where necessary, but yeah that's scary!
Was there last night boxing was good 👍
Nice one 👊🏾
What is the music ?
Just off UA-cam studio 👍🏾
Sounds like something out of the Knight Ryder 😂
😂
😎👍🤜
👊🏾👊🏾