How to Install and Adjust VHS Motor for Deep Well Turbine Pumps

Поділитися
Вставка
  • Опубліковано 21 жов 2024

КОМЕНТАРІ • 8

  • @Day_1_Construction
    @Day_1_Construction 3 роки тому

    Thank you! Great video.

  • @valentingrimaldoponce1488
    @valentingrimaldoponce1488 4 роки тому

    Good night friend, I am going to install a 500 hp vertical pump, but I have doubts about the coupling because the pump has a threaded shaft with a coupling, I would like to see if you can guide me, thank you

  • @ronfosterjr278
    @ronfosterjr278 6 років тому +3

    Please help me understand why you adjust this pump up 70% without knowing the K factor of the bowl and the shaft diameter, shaft elongation and pump setting. I think this video could be miss leading or incorrect without all of the information. This video makes it sound lie all turbine pumps get adjusted 70% what if it was open impellers? I think this video should be redone with the right info

    • @joemann7667
      @joemann7667 5 років тому

      Do you know where I could find the coupling for the headshaft in this video?

    • @bigamigo4863
      @bigamigo4863 3 роки тому +1

      He's only setting the lateral of the pump (the available space for stack adjustment). The stack height would be adjusted when the pump is installed - to proper impeller height based on thrust, shaft and column elongation, impeller/pump weight etc.

  • @asifali1427
    @asifali1427 6 років тому +1

    sir12"inch 6 impier fan assambliy praise send me one pece

  • @bekiracar1228
    @bekiracar1228 7 років тому

    good