How to install and align a pump and motor coupling on an API 610 VS4 pump

Поділитися
Вставка
  • Опубліковано 10 лют 2019
  • How to correctly install and align an API 610 VS4 vertical sump pump coupling between the pump shaft and motor pump to minimise vibration when operating. For more information visit www.amarinth.com
  • Наука та технологія

КОМЕНТАРІ • 6

  • @bilhagy
    @bilhagy 3 роки тому

    Hello,
    I have a pump where the spacer slightly moves to the left and right between the two couplings
    IS THAT NORMAL? OR SHOULD THE SPACER NOT MOVE AT ALL?

  • @nextrotatingsolutions9950
    @nextrotatingsolutions9950 4 роки тому +1

    ... Did you just use a ruler to check alignment? if you manufacture API equipment please have your clients use a dial or laser. Based on RPM you should be aiming for .05-.09 mil angular and 1-1.5 mil offset. Also is this doweled, flat faced or a spigot? Even a spigot can have a .005"-.0020" slop. Don't for get to check you TIR at the shaft closet to the coupling to ensure you have done the alignment correct

  • @lingeshwaranb28
    @lingeshwaranb28 Рік тому

    What is the type of coupling being used?

  • @Prabhuchamy1
    @Prabhuchamy1 4 роки тому

    Why can't you install the motor side coupling beforehand

  • @PilgrimPiper
    @PilgrimPiper Рік тому

    👀

  • @cck1496
    @cck1496 Рік тому

    I don't think so,it will give you correct alignment.... It's just a rough alignment..