Thank you so much sir for all you do. I get it very well but my issue is the shock. I have done this connection twice with 2 different energizer (wizord 4 and druid 13) what I noticed is that the earth lines are the only once with current which are just 2 lines out of 6 for 6 lines installation. But when any line is tempered with (cut) the alarm goes off but the live wires can be touched with bare hands with not shock this has been my observation. Please is this how it works or can something be done? Thanks in anticipation.
Wow! Congratulations! I am very happy to hear this, you are a very observant fellow like me and it's obvious that you will go very far too. I totally understand what you are talking about and I have also observed it. What you need to do is, 1. Do you have earthrod installed with the fence. If you don't have that, please install earthrods 2. Alternate your lines, as in, the terminal on the Energiser that has shock can be swapped with the earth, but ensure that the link at the buttom of the earth terminal is removed and moved to the other side, which is the live, thereby having more lines with shock. I hope this explanation is clear?
@@defotechtv9093 Thank you very much sir. I haven't been using earth rods. But I will check that out in your videos on how it's done (earth rods installation). So you mean the remedy for that is for me to remove the earth loop under the energizer and use earth out - earth in in place of live in - live out then loop the live as a single wire to replace the earth?
Thanks so much for this
You are welcome
Thank you so much
You are welcome. Thanks for reaching out
Well explained..., Thank you sir
You are welcome.
Thank you so much sir for all you do. I get it very well but my issue is the shock. I have done this connection twice with 2 different energizer (wizord 4 and druid 13) what I noticed is that the earth lines are the only once with current which are just 2 lines out of 6 for 6 lines installation. But when any line is tempered with (cut) the alarm goes off but the live wires can be touched with bare hands with not shock this has been my observation. Please is this how it works or can something be done? Thanks in anticipation.
Wow! Congratulations! I am very happy to hear this, you are a very observant fellow like me and it's obvious that you will go very far too.
I totally understand what you are talking about and I have also observed it. What you need to do is,
1. Do you have earthrod installed with the fence. If you don't have that, please install earthrods
2. Alternate your lines, as in, the terminal on the Energiser that has shock can be swapped with the earth, but ensure that the link at the buttom of the earth terminal is removed and moved to the other side, which is the live, thereby having more lines with shock. I hope this explanation is clear?
@@defotechtv9093 Thank you very much sir. I haven't been using earth rods. But I will check that out in your videos on how it's done (earth rods installation). So you mean the remedy for that is for me to remove the earth loop under the energizer and use earth out - earth in in place of live in - live out then loop the live as a single wire to replace the earth?
@@Ebiz-yt9tr Absolutely.
Thanks so much
You are welcome
Good morning Sir, Can wire coming out from the heartrod going directly to the energizer before taking it out to the fence heart connection, thanks.
Yes, absolutely
You mean physically connect the wires on all the 3 sides first using the ferrules ?
I don't understand this question at all
Thankyou so much sir
Most welcome
Can u connect heart directly to d Energizer without earthrof?
No . You need an earthrod to terminate it to .
Can you repeat circulation again mister
@@JosephApepa Good day sir, what do you mean by "circulation"?