  • @flylow4017
    @flylow4017 2 місяці тому

    Felicitari pentru prezentare , pe data de 29.10.2024 am pornit inv Deye hibrid cu 30 panouri Canadian N Type Top Con 460W. Astept in 2-3 saptamani sa devin prosumator. As aprecia tare mult daca iti permite timpul sa schimbam cateva cuvinte. Multumesc inca odata pentru informatiile valoroase ce le-am regasit in ambele video despre inv. Deye.

  • @cptbill80
    @cptbill80 3 місяці тому

    w04 meter comm fail also here with an external CT (chint). It just appears randomly and doesnt affect anything. Weird problem. My inverter is a 12K Hybrid Deye.

  • @nickzouein
    @nickzouein 7 місяців тому

    can you please only explain what the "Gen Port and Smart Load" usage is for.

  • @portugalvilla8071
    @portugalvilla8071 9 місяців тому

    Hi Gigi, Why did you use a extra smart meter from Eastron, is it worth the extra money or not? What is the difference with or without? I am going to install the same inverter and thinking to buy the extra meter or not ... what are your thoughts? If so Eastron or Shint ? Thanks 🙂

  • @nyeinchanphyoe1496
    @nyeinchanphyoe1496 7 місяців тому

    At time working on Generator, there have been some issues when grid is ON?

  • @alexandrubocancia9239
    @alexandrubocancia9239 6 місяців тому

    Bună ziua, Mulţumesc tare mult pentru video. Aş vrea să vă întreb dacă funcţia "smart load" poate fi folosită dacă nu există baterii? Mai exact dacă producţia panourilor depăşeşte 3000 w (cât este rezistenţa la boiler-ul meu) să activeze boiler-ul şi eventual dacă se poate combina ce produc panourile cu diferenţa din reţeauna naţională? Mulţumesc tare mult

  • @hd20max
    @hd20max 10 місяців тому

    Hello Gigi. There is a swiching time delay in case of grid off / battery on ?

    • @GigiBeleaDK
      @GigiBeleaDK  10 місяців тому

      A few ms , you will not notice the switchover. I have servers running on Load port and whenever I switch off the grid the servers will keep running without any problem.

  • @paulierco
    @paulierco Рік тому

    1. What is the maximum consumption that can support on the GEN port? Can you connect the whole house? I have a heat pump, switches, servers and others. The maximum consuption shouldn't be more than 5kw.
    2. Do you know if there are any differences between 12Kw model and 30Kw model? I have 3 Huawei Inverters (10+10+4kw) + backup box (without battery) and I'm thinking to switch to Deye + batteries. I have 28Kw of panels (high peak of course)
    Thanks a lot.

    • @GigiBeleaDK
      @GigiBeleaDK  Рік тому

      1. Max capacity of the inverter is 12kw , so whatever you put on GEN + Backup port must not exceed 12kw then you will be fine. 2. Think the only difference would be the capacity , else all functions should be the same , but 30Kw is only for HV batteries.

    • @sobanidrees2999
      @sobanidrees2999 4 місяці тому

      Could it be possible to use micro inverters at PV string(AC output) to be fed at Gen port which would definitely spare a MPPT port for additional input(which could be used for wind turbine controller output) ​@@GigiBeleaDK

    • @GigiBeleaDK
      @GigiBeleaDK  4 місяці тому

      @@sobanidrees2999 Yes, Deye confirmed is possible.

    • @ericrasgo798
      @ericrasgo798 21 день тому

      @@sobanidrees2999 can you also use grid tie inverter instead of micro inverter

    • @sobanidrees2999
      @sobanidrees2999 19 днів тому

      @@GigiBeleaDK
      By doing so can deye user could increase the input power to battery bank or that gen port only work for feeding load meanwhile the MPPT Input(wind turbine) would only be the power available to be fed to storage batteries ??

  • @caraselul
    @caraselul 11 місяців тому

    Hello, i have the same inverter. Can i use the Gen port to power directly a 6kw water heater? What happens if there is only 4 kw of power available on solar?
    I don’t want to use the grid for smart load,
    I am not selling , i just want to put the excess solar power in an 500 liters puffer

    • @GigiBeleaDK
      @GigiBeleaDK  11 місяців тому

      If there is not enough PV the inverter will pull from battery , without battery smart load port will not work unless you say the port should be active as long as there is grid connection , then will pull from grid.

  • @targaplus4675
    @targaplus4675 Рік тому

    Hi Gigi, where can I buy the Wifi circuit breakers

    • @GigiBeleaDK
      @GigiBeleaDK  Рік тому

      Found them on eBay but I think you can get them a bit cheaper from Aliexpress.

  • @paweljandobruk1791
    @paweljandobruk1791 Рік тому

    Hi . Please tell me is this iventer deye 12 works 100 % off grid . Just only pv and aku ? Zero grid . Thx for answer . And happy new year 2024 .

    • @GigiBeleaDK
      @GigiBeleaDK  Рік тому

      Yes, it will work offgrid also but think the self consumption of the inverter is around 70-80w .. so you will have a constant draw on the system.

    • @arturagonski4674
      @arturagonski4674 11 місяців тому

      @@GigiBeleaDK How much are you sure about this self consumption? I plan to use it for off-grid and when it's night only to power 60W for PLC/HMI, so I don't need big battery, but taking into consideration this consumption it more than double my needs. Other inverters show sth around 10-20W when it's idle.

    • @GigiBeleaDK
      @GigiBeleaDK  11 місяців тому

      @@arturagonski4674 I am pretty sure :)

  • @piparussmekeru6869
    @piparussmekeru6869 11 місяців тому

    Gigi Belea,dar romaneste nu mai stii?

    • @GigiBeleaDK
      @GigiBeleaDK  11 місяців тому

      De cand esti tu "smeker" nu. Invata engleza :)

    • @piparussmekeru6869
      @piparussmekeru6869 11 місяців тому

      @@GigiBeleaDK eu stiu engleza,ca de asta ti-am urmarit tutorialu,asa l-am si gasit,am tastat in engleza ce ma interesa,