Renogy (RBM500) 500A Battery Monitor Unboxing & Installation

Поділитися
Вставка
  • Опубліковано 17 лип 2022
  • ​‪@RenogySolar‬
    ‪@renogyjapan448‬
    USA Link:
    amzn.to/3l86oJ7
    Canada Link:
    amzn.to/3JaIhBI
    UK Link:
    amzn.to/423QGiT
    This is the 500A shunt battery monitor Model# RBM500. Installation is very simple make sure you have the proper wire or buss bar to connect the shunt to the battery does not include one
    Renogy 500A Battery Monitor with Shunt, High and Low Voltage Programmable Alarm, Voltage Range 10V-120V and up to 500A, 20ft Shielded Cable, Compatible with 12V Lithium Sealed, Gel, Flooded Batteries
    【1% Accuracy Measurement】Shunt-type monitor design provides much more accurate real-time voltage and current draw measurement.
    【Protect the batteries】With High and low capacity alarm functions, our battery monitor with shunt will alarm, and backlight and voltage value will flash simultaneously to protect the batteries from getting over-discharged.
    【Fit for all battery】Compatible with various battery types, including Lead Acid (AGM, GEL), Lithium Iron Phosphate, Lithium-ion, Nickel-metal hybrid.
    【Easy To read】Displays multiple electronic parameters, including Voltage, Current, Consumed Power, Battery Capacity, and battery degradation rate with a customized brightness high-definition Backlight Display.
    【Easy to Install】Transparent shunt holder makes it easier to mount the shunt. And the 20ft Shielded cable allows you to monitor the battery status from a distance.
    Renogy 500A Battery Monitor
    The Renogy Battery Monitor is designed to monitor performance for most kinds of batteries. Its high-precision measurements will eliminate the guesswork from battery usage and improve your battery bank's overall performance and longevity!
    It is a universal battery monitor that you can use with voltage ranging from 10V to 120V and up to 500A.
    Adjustable brightness levels to keep you comfortable at night and save your battery power.
    Allow you to customize the turn-off voltage to save battery power.
    Professional's choice that allows you to monitor your battery degradation timely.
    Temperature range: 32°F -95°F
    Voltage Accuracy: ± 1%
    Current Accuracy:± 1%
    #solarenergy
    #renewableenergy
    #shunt
    #freeenergy
    #solarmeter
    #offgrid
    #solarpanel
    Capacity Accuracy:± 1%
    Backlight on current (50A): 100mA
    Weight (LCD Interface) 2.6 oz / 75 g
    Size (LCD Interface) 3.9 x 2.4 x 0.7 in / 99 x 61 x 18 mm
    Temperature range 0-35°C
    Shielded Wire Length 20 ft/6 m
    B+ Wire Length 3 ft/1 m
    Working Voltage: 10-120V
    Working Dissipation: 10-15mA
    Standby Dissipation: 1-2mA
    Temperature range: 32°F -95°F
    LOW POWER CONSUMPTION DESIGN
    The backlight will automatically shut down when the charging current is <100mA and only 1 mA Standby Dissipation. This battery monitor is equipped with data storage capacity. It automatically saves the last testing data when its power is off.
    PROTECT YOUR BATTERY
    This monitor gives you high precision current detection and accurate battery state of charge. You can also set an alarm for high or low current voltage. When the alarm is activated, the backlight and voltage value will be shown on the screen to alert you on what to do when you reach the cut-off voltage.
    EASY TO INSTALL
    The package includes
    The LCD interface,
    500A shunt,
    transparent shunt holder,
    20 ft shielded wire,
    and B+ wire.
    The shunt holder makes it very convenient to mount the shunt while the long shielded wire allows you to monitor the status of your battery from a distance.
  • Наука та технологія

КОМЕНТАРІ • 90

  • @johndixon5539
    @johndixon5539 7 місяців тому +2

    Thank you for help on the installation. Great job.

    • @DIYKAI
      @DIYKAI  7 місяців тому

      Your welcome

  • @vdub1959
    @vdub1959 2 роки тому +7

    Thanks for posting this vid. I had some minor difficulties getting the provided battery + red wire in that small hole. Eventually got it to slide in… Otherwise this is a very solid and well made monitor. Only gripe is how the screen mounts, I prefer the bezel approach like the other monitor screens and switches from Renogy.

    • @DIYKAI
      @DIYKAI  2 роки тому

      Your welcome! Yup we had the same issues and grip lol hopefully they fix a lot of the customers concerns that’s a quick way to lose people

  • @andyirons7162
    @andyirons7162 10 місяців тому +3

    Tip for other newbies ---> that positive wire is a pain to get into the shunt spacing.....true pain in the you know what (perhaps I just had crappy socket opening)

    • @DIYKAI
      @DIYKAI  10 місяців тому

      Yes you have to get creative with connections sometimes

  • @baneverything5580
    @baneverything5580 2 роки тому +3

    Been looking at these. I just received a 300 ah Ampere Time LiFePo4 for emergency solar power in my camper. I have 11 solar power stations for all the small stuff and my chest freezer and dorm fridge but need some emergency air conditioning after hurricanes. Plus I can use it to reduce my electric bill so I can buy other things which is important when you`re on a tiny Social Security check. Spend my savings on the battery, 60 amp MPPT charge controller, wiring, and fuses. I already have 500 watts of glass panels, several sets of 20 ft MC4 cables, and 100 and 120 watt high quality folding panels. Gotta figure all this out on my own but I`m studying about it. Gotta get one of these monitors too.

    • @DIYKAI
      @DIYKAI  2 роки тому +2

      it's well worth it you will know exactly how much power you have and what's coming ang going out the battery

    • @baneverything5580
      @baneverything5580 2 роки тому +1

      @@DIYKAI I have nothing right now but a watt meter to measure what`s coming out of the inverter but that doesn`t measure inverter losses. Not sure what the losses will be since they can vary wildly. But right now I at least have enough backup power for cooling off if a storm comes any time soon. In the process of moving which got very expensive fast due to my sister screwing up repeatedly trying to get electricians to hook up my camper. Thank God I got the battery before this happened or I`d have no money left. I made the mistake of assuming she had a working brain.

    • @DIYKAI
      @DIYKAI  2 роки тому

      Usually a modified sine wave inverter is about 85% efficient and a pure can be between 90-95%

  • @arkhamkillzone
    @arkhamkillzone 27 днів тому

    Mine is showing how much I use but not much is going back in.

  • @camperbum
    @camperbum 2 роки тому +1

    I have this, I need to see about adjusting the light, also, I needed a longer cable, found one on Amazon, had to file some plastic tabs off at one end but it worked out great for me...

    • @DIYKAI
      @DIYKAI  2 роки тому +2

      this one has 8 levels of light adjustment, or you can turn it off we are going to mount it today hopefully all goes smooth

    • @camperbum
      @camperbum 2 роки тому +2

      @@DIYKAI I know how to turn the light on and off I want to see if mine adjust, I mounted mine inside my trailer, the cable was to short, so I had to find a longer one, hopefully you don't have that problem lol.

    • @DIYKAI
      @DIYKAI  2 роки тому +1

      @@camperbum Ah got ya….ours is in a solar back up room so we went straight into the Sheetrock lol all is good

  • @2gunslefty
    @2gunslefty Рік тому +1

    Could I extend the postive wire so I can mount in, under the bed where all my power connections are? Or can I tap into the power lead to the battery? Thanks any help would be appreciated

    • @DIYKAI
      @DIYKAI  Рік тому +1

      With the shunt the neg needs to come directly from the battery and all loads on the other side......as far as the power side the main also on the hot side but you should be able to tap it anywhere off the main as it's just sampling from that side and powering the screen

  • @lisarouillier7727
    @lisarouillier7727 2 роки тому +1

    Nice ⭐️⭐️⭐️⭐️

  • @LA-Creative
    @LA-Creative Рік тому +1

    Hi great video! I like how you show it in action. Do you know if the meter can be used with non-Renogy controllers (just for the use you demonstrated, not Renogy app use)!

    • @DIYKAI
      @DIYKAI  Рік тому

      Yes it will work without the app and just using the monitor

    • @DIYKAI
      @DIYKAI  Рік тому

      Thanks!

  • @cruzincondo3395
    @cruzincondo3395 Рік тому +2

    How does this reset? Mine keeps showing the prior setup for another battery I had it connected to

    • @DIYKAI
      @DIYKAI  Рік тому

      I believe you have to go into the settings or leave it disconnect for 30 minutes

  • @BIGTREESJOE
    @BIGTREESJOE Рік тому +1

    how did you bend the bus bar and did you drill the holes before or after it was bent? I have a piece of 1/8x 1 bus bar that I'd like to use for that.

    • @DIYKAI
      @DIYKAI  Рік тому

      Vise and a good ole hammering. Drilled before use some heat to bend and oil to drill

    • @WizzRacing
      @WizzRacing Рік тому +3

      You don't have to do any of that. Just get the Blue Sea Terminal Block 5191 without the fuse.. The block will make the connection to the battery terminal. As these Fuse Blocks are designed for fuses to make the final connection. But the Shunt hole is big enough to fit over the insulator...Best way I found without all the fuss...

    • @JustScottPaid
      @JustScottPaid 10 місяців тому +2

      ​@@WizzRacingGreat idea! Thanks!

  • @Mike-ip8hg
    @Mike-ip8hg 4 місяці тому +1

    Nice video easy to understand.question what size is the bolts on the shunt. Thanks mike

    • @DIYKAI
      @DIYKAI  4 місяці тому

      Thanks we will check and reply back

  • @LachlanBarclay4wd
    @LachlanBarclay4wd Рік тому +1

    I noticed the backlight is flashing when its charging, is there a way to turn this feature off and does it stop flashing if you have the backlight turned off?

    • @DIYKAI
      @DIYKAI  Рік тому +1

      Yes you can turn it off we find it annoying that it flashes while charging. Yes backlight is totally off when you select it off and stays off until you turn it back on

  • @JADudley
    @JADudley Рік тому +1

    Before I purchase I am trying to find out if it can transfer the data to the charge controller so the info can be transferred via Bluetooth

    • @DIYKAI
      @DIYKAI  Рік тому

      Not sure we can check and get back to you

  • @terryhorrocks2685
    @terryhorrocks2685 10 місяців тому +1

    I have one of these but it never shows a plus input only out whatts or amps
    I have 400w solar dc2dc and 240 charger but it never shows or adjusts the remaining amp hours/ battery life
    The only way I know it’s charging is the battery volts climb back up to 14.2
    Is this a common fault ?

    • @DIYKAI
      @DIYKAI  10 місяців тому

      No we never had that issue we set it on e last year and its been on autopilot since

  • @Snake16
    @Snake16 Рік тому +1

    Hi. The company that installed my Renogy 2000w Pure sine inverter charger put it in the back of a cupboard that i have No access too..
    So i need to a add a battery monitor screen.
    Can i use this Renogy shunt monitor on my Renogy 200w pure sine Inverter charger ?
    (I contacted Renogy directly but they've replied saying it cant be used with my 2000w charger inverter)
    (I am a bit confused because I've seen videos on youtube of people using them together)

    • @DIYKAI
      @DIYKAI  Рік тому

      The shunt can be used in any system up to the amps it’s rated for….this shunt is good for 500A at 14vdc or so……you will be fine on a 2kW inverter…..we have it on a 3kw inverter

    • @DIYKAI
      @DIYKAI  Рік тому +1

      The shunt goes between the inverter and battery make sure you have the proper size wire for your loads we use 2/0

  • @crossthreadaeroindustries8554
    @crossthreadaeroindustries8554 Рік тому +1

    Do you program in the battery technology you are using? It looks like you use LiFe batteries which can be taken to complete empty? I am using AGM which can go 50%, only.

    • @DIYKAI
      @DIYKAI  Рік тому

      Yes lifepo4 we drain them to about 20% most of the time

    • @DIYKAI
      @DIYKAI  Рік тому

      Yup agm lead acid 50%Dod

  • @ShadowAlmighty
    @ShadowAlmighty 4 місяці тому +1

    I just installed this with my RV batteries, and it seems to work great. I would, however, like to have a monitor at the front of the coach and one at the rear. Is it possible to put two of these monitors in parallel?

    • @DIYKAI
      @DIYKAI  4 місяці тому

      Yes while but this is possible, When connecting the two shunts in series, errors in the battery voltage measurement can occur. The shunt that is not directly connected to the battery loses the voltage drop of the other shunt in the voltage measurement.

    • @DIYKAI
      @DIYKAI  4 місяці тому

      But if you can connect one to each battery that’s better or go with an induction pickup type that just clamps around the wire for up front as you are only going to be monitoring only from one hope this helps

    • @ShadowAlmighty
      @ShadowAlmighty 4 місяці тому +1

      @@DIYKAIThanks for the reply. Still trying to understand this. So the meter is measuring a small voltage drop across the shunt which can be used to calculate current through the shunt, is that correct? What if I wired in a second meter on the same shunt, so basically the two meters were connected together? I'm not sure how I would do this, I guess I'd have to splice into the first meter's connecting wires. Would this cause an error in the readouts?

    • @ShadowAlmighty
      @ShadowAlmighty 4 місяці тому

      Also, I can already monitor the voltage up front, with a simple cigarette lighter meter, but I'm mostly interested in how much current is going into the batteries from the alternator, and knowing when they are fully charged.

  • @carl8568
    @carl8568 Рік тому +2

    Why do you need a bus bar for higher amperage? I'm setting up a 24v system with 540ah of LA storage.

    • @DIYKAI
      @DIYKAI  Рік тому +2

      We like to use bus bars because they are rigid less chance of something coming loose

    • @carl8568
      @carl8568 Рік тому +2

      @@DIYKAI
      Ok, no worries. Thanks for the quick reply.

    • @DIYKAI
      @DIYKAI  Рік тому +1

      @@carl8568 Your welcome its more preference than anything we always like to over engineer things lol

    • @carl8568
      @carl8568 Рік тому +3

      @@DIYKAI
      That's a good philosophy mate. I'm setting up off grid in an area in Australia that is prone to bushfires in summer, and the last thing I want it for my system to overheat and cause a fire.

    • @DIYKAI
      @DIYKAI  Рік тому +3

      Pure bar would definitely outlast wire and rubber lol we generate about 2.2kW a day off 600w

  • @noahbell7767
    @noahbell7767 Рік тому +1

    I like that it says how much time you can run the load

    • @DIYKAI
      @DIYKAI  Рік тому +1

      Yes and it’s very accurate

  • @borrowedtime2559
    @borrowedtime2559 2 місяці тому +1

    I have my renogy monitor connected to Trolling motor + circuit breaker + battery and all negatives are connected correctly but the "Remaining AMP Hours" are stuck on Zero when i run test the motor... any ideas why this is so? Or is this product simply only works with inverters? or do i need something else connected to the Negative?

    • @DIYKAI
      @DIYKAI  2 місяці тому

      should be battery negative to one side all other negs to other side. Did you set the Ah up in the menu

    • @borrowedtime2559
      @borrowedtime2559 2 місяці тому +1

      @@DIYKAI yup did all you mentioned and still Zero in the remaining hours 😭

    • @DIYKAI
      @DIYKAI  2 місяці тому +1

      @@borrowedtime2559 hold the up arrow for a few seconds

    • @borrowedtime2559
      @borrowedtime2559 2 місяці тому

      @@DIYKAI yeah tried resetting using both up and down and still no use. I noticed the Amp reading barely budge above 3Ah no matter how high I adjusted my motor throttle. I suspect the meter was reading DC only as I'm in Australia and we have AC .. that's my guess really

    • @DIYKAI
      @DIYKAI  2 місяці тому

      @@borrowedtime2559 so the shut won’t measure amps of the motor it will only display capacity of the battery and watts/amps being drawn out of the battery

  • @marksmith2434
    @marksmith2434 10 місяців тому +1

    I bought one and installed it as per the instructions. Its been used for about a month and only ever shows 100%.... I disconnect the DC/DC charger for 3days and let my car fridge run in a hot car and it still shows 100% !! Not sure what the issue is..

    • @DIYKAI
      @DIYKAI  10 місяців тому +1

      Have you gone into the setting and tried to adjust

  • @sherrieeverett4733
    @sherrieeverett4733 Рік тому +1

    Ok, I found this video helpful. But, why did you have to make the "Z" part? Is that something I will have to do when I instal? I didn't understand that part. Thx!

    • @DIYKAI
      @DIYKAI  Рік тому +1

      Hello thanks for watching…….that Z piece is a stand off because it does not sit flat and we wanted it connected directly to the battery….if you use the provided holder and run battery cable off each side you will be fine….this was just not wanting to have extra wire to deal with

    • @sherrieeverett4733
      @sherrieeverett4733 Рік тому +1

      @@DIYKAI Where do I find all the values enter into the monitor?

    • @DIYKAI
      @DIYKAI  Рік тому +1

      @@sherrieeverett4733 Press and hold the OK button to enter the menu

    • @sherrieeverett4733
      @sherrieeverett4733 Рік тому +1

      @@DIYKAI how do I know the values to enter, I have 100ah

    • @DIYKAI
      @DIYKAI  Рік тому

      @@sherrieeverett4733 the battery should have came with a card….what type of battery are you using?

  • @edthompson342
    @edthompson342 Рік тому +1

    What size hole does the monitor fit in?

    • @DIYKAI
      @DIYKAI  Рік тому

      We can check for you but it was maybe 1”x3”

    • @DIYKAI
      @DIYKAI  Рік тому +1

      Just under 4” wide and about 2.5” height
      5/8” thick

  • @Stuff7164
    @Stuff7164 11 місяців тому +1

    Can this unit monitor a bank of batteries, or do you need one monitor per battery in the bank?
    Thanks in advance.

    • @DIYKAI
      @DIYKAI  11 місяців тому +2

      Hello and thanks for viewing.
      It monitors the whole system. All your load negatives will go to the shunt.
      This single shut can handle 500A it does not matter how much reserve capacity you have. We use it with two 400aH batteries no issues

    • @Hawkcrom
      @Hawkcrom 5 місяців тому +1

      @@DIYKAIso you have the monitor set to 800Ah ?

    • @DIYKAI
      @DIYKAI  5 місяців тому +1

      @@Hawkcrom typo we meant (2) 200Ah

  • @UKvet246
    @UKvet246 6 місяців тому +1

    What is the terminal size please

    • @DIYKAI
      @DIYKAI  6 місяців тому

      Not sure it’s either M8 or M6 you will have to have a bus bar or similar to attach it to the battery

  • @thomasoconnor1068
    @thomasoconnor1068 Рік тому +1

    Busbar standoff? Why are 2 sides hooked to negative? Confusing video.

    • @DIYKAI
      @DIYKAI  Рік тому +1

      standoff is a term used...you can say its like a bridge.......shunts work only on the negative side as with DC it flow Neg-Pos......you have to have basic electrical knowledge before attempting something like this for safety reasons

  • @benjamindavidscargill5633
    @benjamindavidscargill5633 Рік тому +2

    Definitely wouldn’t buy this again, it’s so frustrating. It should be simple but the bolts are so thick they’re too big to for any of the rest of my setup. Don’t have any wire lugs big enough to fit on them and don’t have the facilities to make a Z bus bar just to fit it on my battery terminal. Absolutely stupid.

    • @DIYKAI
      @DIYKAI  Рік тому

      Yes this is a 500A shunt that’s why it’s so large. Maybe try a smaller one what size is your system?

    • @benjamindavidscargill5633
      @benjamindavidscargill5633 Рік тому +1

      @@DIYKAI Only a 200amp system at the moment but I have things to add. I've managed to fit the shunt now but I'm not getting anything from the actual monitor LED screen. Do you know why that might be? (The shunt is wired in series on my negative side as instructed and all my appliances are working as normal) I've tried the positive in each positive terminal of the shunt and still nothing. Could my device be faulty?

    • @DIYKAI
      @DIYKAI  Рік тому

      @@benjamindavidscargill5633 Ok shunt connected directly to battery one side the other side all loads.
      Did you wire the monitor power it should be some small wires

    • @benjamindavidscargill5633
      @benjamindavidscargill5633 Рік тому +1

      @@DIYKAI yeah I have the shunt coming directly off the negative terminal with all the negatives coming off that with the small red power cable attached to the positive terminal.

    • @DIYKAI
      @DIYKAI  Рік тому

      @@benjamindavidscargill5633 weird ok we will look at our system real quick and let you know how we have it