Leaking water heater T&P troubleshoot & repair(PRV replacement#2)

Поділитися
Вставка
  • Опубліковано 29 чер 2024
  • ln this video a troubleshoot and repair a T&P on a water heater. l cover material, tools and what you need to know to get the job done.
    Like and subscribe!!
    T&P
    amzn.to/3zQx0W2
    12" Pipe wrench
    amzn.to/3SeNrC3
    Channel lock pliers
    amzn.to/3y7OJrv
  • Навчання та стиль

КОМЕНТАРІ • 2

  • @briancrandall1601
    @briancrandall1601 20 днів тому +2

    I had the same problem after adding a prv. The water services have check valves before the meters which makes it a closed system. A expansion tank was added after the prv and inflated to match the water pressure and it fixed the leaking t&p valve.

    • @HomeownerDIY
      @HomeownerDIY  20 днів тому +1

      Thanks for the comment, there is an expansion tank above the water heater but it was so poorly done that it wasnt doing anything. Stay tuned for that video.