  • In this video, you will learn about hipot test for 11kv cable, hipot testing procedure, high voltage testing of electrical equipment.
    #Hipot
    *****************************************************
    Get in touch with Electrician Iइलेक्ट्रीशियनI Adda Iअड्डाI
    टैकनीकल वीडियो देखने लिए Electrician Adda चैनल को सब्सक्राइब करें।
    1. RMU Operation in Hindi | Ring Main Unit Operation in Hindi |
    • RMU Operation in Hindi...
    2. Ring Main Unit Working | Basic knowledge Of RMU in Hindi | Ring main Unit (RMU) |
    • Ring Main Unit Working...
    3. Parts and accessories of Ring Main Unit | Parts of RMU | Ring Main Unit "RMU" Practical Components |
    • Parts and accessories ...
    4. Breather in a transformer in Hindi| transformer breather working | what is breather |
    • Breather in transforme...
    5. HT XLPE Cable Jointing Procedure | HT Cable Jointing Training in Hindi |
    • HT XLPE Cable Jointing...
    6. Parts Of Transformer and Their Functions in Hindi |ट्रांसफार्मर के पार्ट्स और उनके कार्य|
    • Parts Of Transformer a...
    7. Special types of transformer | Auto-transformer | Welding transformer | Earthing transformer |
    • 7 Special types of tra...
    8. What is Circuit Breaker and Types of Circuit Breakers in Hindi
    • What is Circuit Breake...
    9. ROLE OF RMU IN RING MAIN POWER DISTRIBUTION SYSTEM | RING MAIN SYSTEM IN HINDI |
    • ROLE OF RMU IN RING MA...
    10. All About Current Transformer In Hindi | What Is CT Ratio | What Is Burden In CT |
    • All About Current Tran...
    11. Potential transformer (PT) in Hindi | Potential Transformer Construction and Working |
    • Potential transformer ...
    12. Air Circuit Breaker in Hindi | Working of ACB in Hindi | Parts of Air Circuit Breaker |
    • Air Circuit Breaker in...
    Thanks🙏

КОМЕНТАРІ • 44

  • @ashishtripathi2261
    @ashishtripathi2261 3 роки тому +1

    Great explanation....thanks for sharing this

  • @greenedificemedia630
    @greenedificemedia630 9 місяців тому

    Very informative, thankx

  • @pradeepgiri3589
    @pradeepgiri3589 Рік тому +1

    Thankyou dear sir 🙏

  • @user-xo7ii2rz7m
    @user-xo7ii2rz7m Рік тому +2

    for 11kV cables, how much DC voltage is injected for the test? is there any specific reference you use for this test to refer to? thanks in advance. 😁

    • @Bholabalatv
      @Bholabalatv 11 місяців тому

      10 kv DC is applied

  • @manoranjan4598
    @manoranjan4598 3 роки тому +1

    Nice sir kooch testing ka aur video banaiye

  • @Bholabalatv
    @Bholabalatv 11 місяців тому

    Awesome bro

  • @pawandwivedi236
    @pawandwivedi236 3 роки тому

    Very good explanation

  • @sefatullah441
    @sefatullah441 2 роки тому

    also tell in video if leakege current appear in device or cable how to trace it and how to troubleshoot the lekage current and how to set it?
    please make a complete video about any test with full information

  • @rajjupiter2847
    @rajjupiter2847 Рік тому

    At the end i have seen HT clip is on cable end and earthing clip on other end of the cable actually that smaller clip should be grounded,since you are testing single phase respect to ground,This test set is meant for single phase testing only.There is another set for phase to phase testing.
    Raj vir singh JUPITER INSTRUMENTS INDIA

  • @sriram8114
    @sriram8114 7 місяців тому

    Sir, Power cable have 11KV 3-phase AC supply, then how it is possible to give DC supply testing for this cable? Please let me know about this ..Little bit confusion sir ..

  • @jaherayo6978
    @jaherayo6978 Рік тому

    Sir ,what is the permissible value of leakage current

  • @vidhyapatijha4858
    @vidhyapatijha4858 Рік тому

    Sir, Folt ka kese pata chalta he. Folt hoga to kya hoga...

  • @lovekushsharma7123
    @lovekushsharma7123 2 роки тому

    Sir solar penal ka hi pot test kese krte h

  • @nuruahmed2575
    @nuruahmed2575 2 роки тому

    can we say the current as no load curreent that we get from the hipot testing

    • @electricianadda
      @electricianadda  2 роки тому

      The hi-Pot test is used to evaluate the insulation condition of the test object. The Hipot test ensures that current will not flow from one point to another and indicates the ability of the insulation to withstand high voltage and over-voltage transient.

  • @shriranggawate6562
    @shriranggawate6562 3 роки тому +2

    Hi

  • @munnakumar-lr2xe
    @munnakumar-lr2xe Рік тому

    How to know that,current leakage or not

  • @kevinamrutiya8892
    @kevinamrutiya8892 3 роки тому

    How much second apply for testing between phase to phase and phase to ground? Also, know me second side cable is open or not?

    • @electricianadda
      @electricianadda  3 роки тому

      Applied voltage for 60 sec.
      and another side cable terminal open

  • @basavarajkumar8197
    @basavarajkumar8197 Рік тому

    Sir how much cost for one day testing in site

  • @Pupul9178
    @Pupul9178 2 роки тому

    Plz formula kya he hm kitina kv denge in 33kv cable pe

  • @pardeepkumar-qz8wn
    @pardeepkumar-qz8wn 2 роки тому

    HT ka phase kha pr touch krnge ji

  • @mohammadvajirullah5062
    @mohammadvajirullah5062 10 місяців тому +1

    Sond nahi aa raha hai

  • @moumitamondal5188
    @moumitamondal5188 3 роки тому

    The voltage applied is AC or DC to measure the leakage current?

    • @pawandwivedi236
      @pawandwivedi236 3 роки тому +1

      DC

    • @ranjeetmlp
      @ranjeetmlp 3 роки тому

      Why apply DC supply...???

    • @electricianadda
      @electricianadda  3 роки тому +1

      When you apply a voltage between the core conductor and the conducting shield of a long cable, this cable is seen by the supply as a capacitor.
      If you apply alternated voltage on a capacitor, some current will be drawn, which is undesirable for a HIPOT test, since HIPOT equipment usually have low current capabilities and it may be hard to differentiate the “capacitor” current from any eventual breakdown current.
      When you apply direct current, after the voltage has stabilized, if some current is drawn, all of it is due to breakdown or leakage.
      So , from above discussion we can see that insulation testing methods are designed to use DC voltage not AC

  • @nuruahmed2575
    @nuruahmed2575 2 роки тому

    thanks for the info but i have a question since we are using hipot testing with the one terminal open(end terminal) how is the current is display on the display pannel

  • @jayprakash5390
    @jayprakash5390 3 роки тому

    Why use dc High voltage for test

    • @electricianadda
      @electricianadda  3 роки тому

      When you apply a voltage between the core conductor and the conducting shield of a long cable, this cable is seen by the supply as a capacitor.
      If you apply alternated voltage on a capacitor, some current will be drawn, which is undesirable for a HIPOT test, since HIPOT equipment usually has low current capabilities and it may be hard to differentiate the “capacitor” current from any eventual breakdown current.
      When you apply direct current, after the voltage has stabilized, if some current is drawn, all of it is due to breakdown or leakage.
      So, from the above discussion, we can see that insulation testing methods are designed to use DC voltage not AC

  • @ranjeetmlp
    @ranjeetmlp 3 роки тому

    Why apply DC supply...???
    Why not apply AC supply...???

    • @electricianadda
      @electricianadda  3 роки тому +2

      When you apply a voltage between the core conductor and the conducting shield of a long cable, this cable is seen by the supply as a capacitor.
      If you apply alternated voltage on a capacitor, some current will be drawn, which is undesirable for a HIPOT test, since HIPOT equipment usually have low current capabilities and it may be hard to differentiate the “capacitor” current from any eventual breakdown current.
      When you apply direct current, after the voltage has stabilized, if some current is drawn, all of it is due to breakdown or leakage.
      So , from above discussion we can see that insulation testing methods are designed to use DC voltage not AC

  • @sbasba7486
    @sbasba7486 2 роки тому

    same point s he did not explain

  • @mahendarbadavath4764
    @mahendarbadavath4764 3 роки тому

    Y music

  • @PavanKumar-ww1jq
    @PavanKumar-ww1jq 3 роки тому

    कितने रुपए की है कहां मिलेगी कांटेक्ट नंबर भेजो

  • @user-we6hg7zr6p
    @user-we6hg7zr6p 2 роки тому

    Please speak english good or arabe or french