Types of Plumbing Valves and Their Functions

Поділитися
Вставка
  • Опубліковано 17 жов 2024

КОМЕНТАРІ • 40

  • @fernandocabanillas8133
    @fernandocabanillas8133 2 місяці тому

    So glad to finally hear somebody pronounce pōtable water correctly

  • @Allintn22
    @Allintn22 Рік тому +4

    Roger i remember when you had about 10k subs then 100k now at the level you built this channel congrats man 20 year service/ install plumber in Tennessee here keep it up

    • @RogerWakefield
      @RogerWakefield  Рік тому

      I appreciate that! This has been a long road, but we made it! Thanks for sticking around

  • @LuckySTR8
    @LuckySTR8 Рік тому +8

    I work in Weatherford and those cast iron meter can always destroy those husky keys because theyre made of aluminum and bend so easily. I always recommend the bronze key to get in and shut it off

    • @RogerWakefield
      @RogerWakefield  Рік тому +5

      That’s a good tip! I have 2-3 different keys that I rotate between

  • @Zero_8347
    @Zero_8347 Рік тому +2

    very educational! i loved being able to see inside the different valve types

  • @iwantmyvanback
    @iwantmyvanback Рік тому

    Neat. I work in irrigation on a golf course and I use a few of these

  • @jordanisrael8631
    @jordanisrael8631 Рік тому

    Hey sir, I am currently renovating a house I inherited built in the 60’s. I had to run a new waterline to a new well/pump. I am inside the house with PVC, and I’m going to convert to PEX-A. There are 2 brands available locally, Sharkbite and Apollo. What are your thoughts on these brands, or should I just go ahead and order Uponor?

  • @Keith_Mikell
    @Keith_Mikell Рік тому

    Just got done using some valves. Flushed out my water heater. It was due. Roger, My house was built in 1980, and so far we have changed most of the valves to ball. I had globe valves and gate valves before. We just did full port ball valves on my outside silcocks. Now the pressure is crazy. My question for you is i have a swing check on the city water (my side) of the meter. It's clanging and banging. That means it's bad, right?

  • @termiterasin
    @termiterasin Рік тому +1

    great video

  • @AdachiCabbage
    @AdachiCabbage Рік тому

    Dang I haven't been on UA-cam in a while. Congrats on your channel having half a million!

    • @RogerWakefield
      @RogerWakefield  Рік тому

      Thank you! Stop by more often😅 miss havin you here

  • @x1984x
    @x1984x Рік тому

    You're supposed to change T&P valves annually? I've never heard that before or seen anyone do that level of water heater maintenance.

  • @DarkCheeld
    @DarkCheeld Рік тому

    Needs more Cow bell.

  • @tphvac87
    @tphvac87 Рік тому

    @rodgerwakefield I know there’s not many boilers in Texas but can you do some boiler videos? Annual t+p changing? I don’t think so…. Hose bib is called a silcock your forgetting a few too, zone valve, water feeder (eg 911s), air scrubber, hy vent, ect.

  • @christianstock7183
    @christianstock7183 Рік тому

    What about angle seat valves definitely the best type for potable water.

  • @bravingbrivatebrian
    @bravingbrivatebrian Рік тому

    What is the distinction between pressure and flow?

    • @kenbrown2808
      @kenbrown2808 Рік тому

      pressure is how hard it is to stop the water, flow is how much comes out.

  • @MesquiteMan
    @MesquiteMan 2 місяці тому

    A gate valve does control pressure, It's just that it does it symptomatically, not specifically

  • @kevinorr6880
    @kevinorr6880 Рік тому +1

    I have a “frost-free” that has the stem broken waay back. It is in brick. Let's talk about replacement?! Thank you.

    • @Hybris51129
      @Hybris51129 Рік тому

      Where I work we have at least three of these types of valve spigots that when you try to use them water erupts out around the face of the spigot and out of the spigot proper. We simply stopped using them because the risk of water being left in the valve and freezing come winter is just too high.

    • @davidt892
      @davidt892 Рік тому +1

      ​@@Hybris51129 Yeah that's why i don't think they should make the regular "Frost-free" hose bibs. They make a better design that drains the water even if the hose is attached, when the hose bib is shutoff. Although that doesn't stop someone from leaving the hose bib on with a closed valve or sprayer on the hose.

    • @matthewjamison1193
      @matthewjamison1193 Рік тому +2

      You could try a rebuild kit, sold typically by brand and length..

    • @kevinorr6880
      @kevinorr6880 Рік тому

      @@matthewjamison1193 I was told it was too old. Bummer.

  • @bodievinyard5809
    @bodievinyard5809 Рік тому

    TMP… 😂

  • @charlescarter4718
    @charlescarter4718 Рік тому +1

    Can I have a job?

  • @kenbrown2808
    @kenbrown2808 Рік тому

    valves are just water switches.

  • @michaeldudas7584
    @michaeldudas7584 Рік тому

    I heard they are going to show your videos to federal prisoners instead of solitary confinement.

  • @cheddarbiskit1
    @cheddarbiskit1 Рік тому

    You didn’t even mention plug valves roger, I’m just a little disappointed right now.

    • @davidt892
      @davidt892 Рік тому

      I didn't even think about plug valves. I was like what about butterfly or needle valves.

    • @RogerWakefield
      @RogerWakefield  Рік тому

      I did mention butterfly but it didn’t make it in

    • @davidt892
      @davidt892 Рік тому

      @@RogerWakefield Your video seems more directed at the home owner, so it makes sense not to include butterfly valves. I was expecting a complete list, but you at least covered the common valves.