Heat Door Actuator - 2004-2008 5.4L Ford F-150

Поділитися
Вставка
  • Опубліковано 27 сер 2020
  • On this episode of Fear No Fix, Chris and Jordan replace the Heat Door (or Blend Door) Actuator in a 5.4L Ford F-150 (model years 2004-2008).
    DTCs (Diagnostic Trouble Codes) associated with this fix:
    • B0229
    • B0414
    • B3770
    Symptoms associated with this fix:
    • No, or limited heat control (all hot or cold air)
    Required Tools:
    Trim removal tool amzn.to/3hy8QnW
    Socket set: amzn.to/3vYpfGm
    8mm wrench: amzn.to/2Tr1WqF
    If this video helped you out, please like it and subscribe to our channel!
    To learn more about BlueDriver automotive tools, visit:
    www.bluedriver.com
  • Авто та транспорт

КОМЕНТАРІ • 133

  • @Jmpostal
    @Jmpostal 2 місяці тому +2

    Thanks to this video, temperature control blend door back to normal, tight space to work in so be patient.

  • @Strib420
    @Strib420 Рік тому +3

    I did not have an error code. I did try everything else prior since the radiator was replaced a year ago. I feared the heater core was clogged. It flushed well, so I replaced the thermostat and flushed the engine bay as well. So, with the issue still present, I decided to try the blender door.
    Everything went as excepted. I did have to remove the navigation module below the radio to help with accessing the bolts.
    Nice to have heat and my cold air again. $29 fix. Having something to back the 8mm bolts out with limited movement would have been nice. I used two hands from each side to hold it steady. I know what a surgeon feels like now.
    Thanks for the video.

  • @terrenceking1665
    @terrenceking1665 2 роки тому +11

    Thanks gentlemen! I'll be doing this repair in a few days when my actuator arrives. Your instruction video gives me confidence this will be an easy job!

  • @paul99501
    @paul99501 2 роки тому +3

    I followed this video to replace the blend door actuator in my 2007 F-150 and it worked perfectly! Accessing those three bolts on it sucks but it all worked. Thanks!

  • @JerryEgge
    @JerryEgge Рік тому +5

    Thanks for the excellent video. I ordered my replacement part for my Ford 2006 F150 from Amazon. I received the correct part, installed it, and it works! I now have full control over my temperatures. However, the install was much harder than this video showed, as my vehicle was Ford F-150, 2006 truck. Two of the three actuator-bolts were on the right side. I couldn’t see nor reach them through the open radio pull-out slot. I had to go through the glove box. However, I still couldn’t see the bolts. I had to remove the passenger dash-panel over. (Right below the airbag.) There we’re four bolts, which I had to remove: two bolts were easy to remove, however, two were located halfway up inside the open glove box. Note, this is just below the airbag area. I have large hands; as a result, I struggled with the removal and install. The good news, I was able to do it. Good luck with your replacement. I hope this helps.

  • @bobdoten8324
    @bobdoten8324 3 роки тому +7

    Wasn't easy with my large hands, but thanks to this video, full heat and full cold are back to normal. Great help for DIY'ers!

    • @LemurMonitors
      @LemurMonitors  3 роки тому +2

      Being comfortable in your vehicle is pretty important! Glad we could help get yours working again!

    • @RussianDaddyO
      @RussianDaddyO 2 місяці тому

      @@LemurMonitors good video, One question.. is this the same on the 2005 F150 XLT 4.6L? My problem is sometimes the directional control does not change from defrost to floor and such. Or do you have a video for that by chance?

  • @freckledtrout3299
    @freckledtrout3299 3 роки тому +6

    Thanks. Was able to replace without any issue. It took about 1 hour but I have experience pulling the radio.

  • @ellissmithjr6599
    @ellissmithjr6599 3 роки тому +4

    Frickin Awesome,this im sure is my problem with the blend door not operating...Thank You 👍🇺🇸🇺🇸🇺🇸.

  • @Cod3Thr33
    @Cod3Thr33 8 місяців тому +1

    Excellent video! This tutorial was 100% accurate, and just what I needed to restore the heat in my 2005 F150. You even mentioned what size wrenches to use, which was a big help. That right forward bolt is a bit of a pain, and if I ever have to do this again, I'll be buying an 8mm ratcheting wrench beforehand. Anyway, thanks for a great video!

  • @billvaughn7368
    @billvaughn7368 3 роки тому +5

    Outstanding, very detailed instructions. Thank you.

  • @muhammadmukarram4065
    @muhammadmukarram4065 3 дні тому

    Thank you very much for uploading this video.
    I was able to change actuator successfully following your step by step video.
    Great video

  • @xaviermercado2079
    @xaviermercado2079 3 роки тому +4

    Great job guys! That helps me to understand the problem!

  • @jefffideler8046
    @jefffideler8046 3 роки тому +4

    Awesome! You guys saved me $1300 today!

  • @dinodino6907
    @dinodino6907 3 роки тому +3

    I love you guys,awesome work and helpful.

  • @randyrat1747
    @randyrat1747 Рік тому

    I am not sure if this is the issue with my heat but if it is you all made it look easy for almost anyone to do!

  • @paul99501
    @paul99501 3 роки тому +3

    Super helpful, thank you!

  • @nomadsadventures
    @nomadsadventures 3 роки тому +3

    Thanks! Just changed mine out with your help.

  • @daveholliday3082
    @daveholliday3082 3 роки тому +2

    Nice video, straightforward and clear. Big help
    Update: Your video was fabulous I will say this project is definitely a pain in the hind end getting that third boat was the most difficult thing I’ve done in three years and I repair houses for a living I have heat now I’m so grateful to you guys. I will say this might be one of those projects that are novice handy person would pay someone to do it would be worth $275 labor easily.

  • @bjl19761994
    @bjl19761994 2 роки тому

    THANK YOU VERY MUCH. This tutorial enabled me to replace my actuator. A bit different with the XLT Lariat package, but same procedure. Excellent instructions!

  • @on-site4094
    @on-site4094 3 роки тому +3

    Great video 👍

  • @selfreliantliving3449
    @selfreliantliving3449 Рік тому

    Thank you for saving me $700!!! I did this and my heater now works!!! Hardest part was the screws for the actuator, someone needs to fire the engineers that put this in the truck!!!

  • @Twilkins20
    @Twilkins20 Рік тому +2

    I did mine with the radio still in. Just took a very small 5/16 opened end wrench and followed your directions

  • @Alex-A-D
    @Alex-A-D 8 місяців тому

    The video helped me a lot👍👍

  • @alexanderwickham8239
    @alexanderwickham8239 3 роки тому +3

    Thank you so much!!!!

  • @josephcarter7881
    @josephcarter7881 2 роки тому

    Thanks that was very helpful

  • @gmracer01
    @gmracer01 2 роки тому +1

    Replaced the blend door as instructed. It only blows warm air which is exactly where this all started. I found that I can manually manipulate the blend door using a spindle. Is there a calibration or sensor elsewhere to check?

  • @timothypitts5795
    @timothypitts5795 2 роки тому +1

    Great video, I have heat but when I switch to defrost mode, there is very little air flow. If I turn to cold air while in defrost mode, there is all kinds of air flow. Is it possible something is blocking the hot air flow to the defroster?

  • @SlimShady771
    @SlimShady771 3 місяці тому +1

    Does this blend door also allow the cold ac air into the cab? I can feel my hvac box get cold with the ac on but it's not blowing out cold

  • @robertschroeck
    @robertschroeck 11 місяців тому

    nicely done thank you

  • @VidaliaOnion88
    @VidaliaOnion88 Рік тому +1

    Is there a position that you need to set first when installing the new blend door actuator? How do you know where to have the temp knob set before installing the new motor? Does it not matter? My problem is my heat is stuck on in my 2004 f150 XL 4.6

  • @JDIZZY024
    @JDIZZY024 2 роки тому +1

    I just recently bought a 05 f150 5.4L I'll be doing this before I even think about getting to the heater core hopefully that's it's thanks for the info

    • @neelsingh916
      @neelsingh916 Рік тому

      Did this solve your problem I was about to do the same before I moved to the heater core

  • @900443980
    @900443980 8 місяців тому +1

    So is there any calibrating that needs to be done when replacing the actuator? I need to replace mine in my 04 f150 4.6 XL (new body). When I take the old one out, how do I know where the new actuator's little gear needs to be to line up with where the ac/heat selection is already? Is this all done automatically with the truck's computer? You simply removed and replaced. Is that really all there is to it and you don't have to line anything up when installing the new one?

  • @jadaf4i
    @jadaf4i 3 роки тому

    Nice guys and easy

  • @victorhugorodriguez4245
    @victorhugorodriguez4245 3 роки тому

    I have 2007 lincoln navigator its the same?

  • @raudelbencomo5372
    @raudelbencomo5372 2 роки тому

    What problem could be if I turn on the heater and lot a smog start coming up from those front vents .?

  • @TonicofSonic
    @TonicofSonic 2 роки тому

    So I did this. I forgot to disconnect the battery.
    Now finished, the unit works, although the strange noises persist.
    But I have a crank no start with a u1900 code.
    Any ideas?

  • @sgt.hollowpoint6968
    @sgt.hollowpoint6968 2 роки тому +2

    Is there any calibration required with new actuator?

  • @seansmith8087
    @seansmith8087 2 роки тому +2

    Question: Which fuse serves this actuator?

  • @juilieta619
    @juilieta619 5 місяців тому

    Do you guys have the link to buy it

  • @bigden31
    @bigden31 Рік тому

    Any way to test the old actuator?

  • @josephweems8551
    @josephweems8551 Рік тому

    Is it the same on an 07 with the V6...?

  • @LoBeau53
    @LoBeau53 Рік тому

    You didn’t mention anything about clocking or orientation. I replaced mine a while back and now get a clicking noise from the actuator at both ends of the range. What did I do wrong.

  • @kevinschwinkendorf3202
    @kevinschwinkendorf3202 2 роки тому

    Are the actuator bolt 7mm also?

  • @rconger24
    @rconger24 7 місяців тому

    5:25. What about re-connecting the electrical lead onto the NEW actuator? 4:23
    Does it need to be clocked?

  • @joshholgin815
    @joshholgin815 2 роки тому

    so i have a question and hoping someone can shed some light on this problem. i have a 2008 Ford F 150 and I am having issues with my AC, the problem is that my cold air works but when i turn on the heater it gets hot on number 1 and 2 but blows cool air on 3 and 4 and was told that it is a blend door actuator issue. But i was looking to get this problem done at a shop but cost a chunk of change then came across this video to help me out with out removing the dash, but i was wondering how many "actuators" are there when it comes to replacing them? Is there one actuator to replace or is there more then one. I know of only 2,the floor one and the top one.

  • @darrendirk4427
    @darrendirk4427 Рік тому +1

    Don't you have to perform a calibration procedure on the actuator by removing a fuse etc?

  • @victorhugorodriguez4245
    @victorhugorodriguez4245 3 роки тому

    Es lo mismo para lincoln navigator 2007?

  • @kaufmankdk
    @kaufmankdk 2 роки тому

    Do I want to start project with Actuator in any special position ?, 2006 F150 Actuator Part # YH1752 FoMoCo Part.

  • @866mary2
    @866mary2 2 роки тому

    I'm guessing this would work on a 2007 Lincoln Mark LT?

  • @ChicoDeon
    @ChicoDeon 2 роки тому

    THANKS

  • @randybills3848
    @randybills3848 Рік тому

    mine came out of park and the cruze control worked perfect just did not have brake lights

  • @RMH7467
    @RMH7467 Рік тому +1

    How do you perform a climate control reset?

  • @adiamond1978
    @adiamond1978 3 роки тому +3

    Maybe a dumb question, but If the blend door and actuator spindle don't line up, do you rotate the blend door or actuator to match?

    • @GeoffPritchett
      @GeoffPritchett 2 роки тому

      I need the answer to this too. This was clearly not done on a failed unit there appears to be no way to align the 2. Thumbs down 👇

  • @chuckgarreaux5292
    @chuckgarreaux5292 2 роки тому

    I didn't see any info on your video of how much coolant goes back in when changing the thermostat and water pump.

    • @LemurMonitors
      @LemurMonitors  2 роки тому

      The correct levels would be found in the owners manual!

  • @leonarddaneman810
    @leonarddaneman810 9 місяців тому +1

    There is a trick to reset the actuator by removing fuse #'s 5 and 13. I got the right side blowing hot . . . I hope another 'reset' procedure can get the left side blowing hot again. In your truck, there is another method not requiring removal of the fuses, but you can't do it with an Auto Climate Control system.

  • @superliner19
    @superliner19 3 роки тому +1

    Thanku made it ez

  • @CanukSteve
    @CanukSteve 10 місяців тому

    Did I miss something? How does the power get to the actuator. I didn't see any disconnecting or reconnection of any wires.

  • @eduardomayoral2497
    @eduardomayoral2497 2 роки тому +1

    How do i know if ?it’s the actuator ,

  • @ruebenchico1425
    @ruebenchico1425 3 роки тому +2

    The question was never answered.. i’ve replaced my blend door and it’s still making the noise as well as blowing out hot air do the gears need to be lined up?

  • @gregstec4738
    @gregstec4738 3 роки тому +3

    Is there an easier way to get the one thru the glove compartment

    • @LemurMonitors
      @LemurMonitors  3 роки тому +1

      There might be an easier angle but this is the one that worked best for us - it's definitely not easy to get to

  • @albertorojas3687
    @albertorojas3687 Рік тому

    Buenas tardes amigo, saludos desde Venezuela. me podrías ayudar facilitándome el diagrama eléctrico de la computadora de la f150, 5.4 3v 2007 cabina y media, gracias

  • @bmanh2355
    @bmanh2355 3 роки тому +7

    How do u adjust the actuator? Is there a reset?

  • @davidpieper6940
    @davidpieper6940 3 роки тому +1

    Video is very accurate. I initially installed the new actuator with out screws and then ran the system, it ran great, hot air. Then, somehow, the actuator splined shaft moved and would not line up and seat where i could install the screws. finally figured i would need to move temp controls and make the device move to where it would seat...now, no hot air again...help!!! What should i do? thanks for any help!

    • @calebsherling5495
      @calebsherling5495 2 роки тому +1

      You should start the engine, turn the temp all the way to 90° then install the motor and screw it in. If this doesn’t work, take the part off and turn the temp to 60° and try again.

  • @RiQWitDaBliQ
    @RiQWitDaBliQ 3 роки тому +1

    Hey guys can you do a video of a 2002 accord ulev vtec knock sensor?

    • @LemurMonitors
      @LemurMonitors  3 роки тому +1

      I will suggest it to the team and see what they say, no guarantees thou.

    • @RiQWitDaBliQ
      @RiQWitDaBliQ 3 роки тому

      @@LemurMonitors thanks for the reply I appreciate it.

  • @derek2851
    @derek2851 3 роки тому +2

    2013 F150. Driver side vents blow correct cooled temp air, Passenger side vents blow HOT air...?

    • @gerard6038
      @gerard6038 Рік тому

      Might be a second unit to change out. I've read that some models have driver and passenger side units.

  • @brucerivers9744
    @brucerivers9744 2 роки тому +3

    What do you do when the shaft won’t line up on the new actuator

    • @jimsmith7716
      @jimsmith7716 4 місяці тому

      Other videos say to turn the key to on, then slightly turn the heat/ac dial until things line up again. Should drop right down.

  • @davidguyton3057
    @davidguyton3057 2 роки тому

    I changed that but I still don't have heat what could it be

  • @JerryWalshSr
    @JerryWalshSr 2 місяці тому

    My problem is the blower ducts do not switch from defrost floor to the panel is it the same idea?

    • @NickW90
      @NickW90 13 днів тому

      There is another actuator that controls that

  • @pasivo2009
    @pasivo2009 3 роки тому +1

    i reemplace but still no have ac and heat

  • @fearmit134
    @fearmit134 2 роки тому

    Does this work on a 2008 ford f150 4.6l

  • @jamieobrien4632
    @jamieobrien4632 6 місяців тому

    This actuator only moves when I turn the dial from hot to cold, where is the one that changes direction of airflow.

  • @janetortiz4861
    @janetortiz4861 Рік тому +1

    Is it the same on 4.6l engine?

  • @alvarovazquez6898
    @alvarovazquez6898 3 роки тому +1

    Me truck no have heat aire

  • @Justin-pt8cz
    @Justin-pt8cz 3 роки тому

    Can you make a video for a 2011

    • @LemurMonitors
      @LemurMonitors  3 роки тому

      I will forward it to the team and see what can be done, no guarantee.

  • @turtlethefam7121
    @turtlethefam7121 Рік тому

    I replace mine now heat comes on on cold side on the coldest setting its luke warm

  • @jadaf4i
    @jadaf4i 2 роки тому +1

    Nice job but mine won't line up to go back in, Why not?

    • @LemurMonitors
      @LemurMonitors  2 роки тому

      Hello Jada!
      Sadly without being able to see the vehicle and get hands on there wouldn't be much we could do to determine why. If the vehicle has ever been in a accident, even if the frame was pulled stright after things could still be misalinged.

    • @rrphelps
      @rrphelps 2 роки тому +1

      @@LemurMonitors I think Jada means that the post/gears don't line up... then what? I am stuck.

  • @ryanclark692
    @ryanclark692 Рік тому

    Looks like a serious murr

  • @robfolks
    @robfolks 3 роки тому

    It's a bitch to change out. Slow and steady gets it done. Took about 1 half hours.

  • @robertogijon795
    @robertogijon795 6 місяців тому

    ❤🎉😇🙏✅

  • @PeteVanDemark
    @PeteVanDemark 2 роки тому +1

    If only a 2006 was this easy. This 2004 seems to have room enough for a small apartment above the actuator.
    The 2006 has barely enough room to slide a wrench through, and zero space for hands. The glove box had to be completely removed and so did the trim plate above it to make access possible at all for the two bolts on the passenger side. Worse yet, it turns out there are two types of actuators, one with a short shaft and one with a longer shaft like the one in this video. Naturally, the parts store sold me the wrong one-just my luck. The cavities exposed under the dash were all coated with dust, and curiously there is no cabin air filter at all for this vehicle. Are the Ford engineers hooked on drugs up there in Detroit or what? Primitive tribes wearing loin cloths in the South Pacific design straw huts with more planning and forethought than the designers of these Ford trucks.

    • @JerryEgge
      @JerryEgge Рік тому

      I have a 2006 model. How do you remove the trim plate? Thanks

    • @qbienemy4663
      @qbienemy4663 Рік тому

      @@JerryEgge if your referring to the trim around the radio, you can use the slimmest thing to slid gently around the trim. I start by opening the ashtray and circling around the trim with my sons ipad case opener, just like they did in this video.

    • @JerryEgge
      @JerryEgge Рік тому

      @@qbienemy4663 Hello, thanks for your reply. No I wasn’t referring to the trim around the radio. I was able to remove it just fine. I had to also remove the trim around the glove box in order to get at all the bolts. I got it done, but it was a pain.

    • @qbienemy4663
      @qbienemy4663 Рік тому

      @@JerryEgge Hey Jerry, sorry I misunderstood, quick question, did it work for you? I literally removed the entire glove box when changing the part but unfort.. that whole change was for nothing because it still doesn't work!

    • @qbienemy4663
      @qbienemy4663 Рік тому

      Any suggestions on what to try next or anything you did different from me? I took the battery loose, removed everything, put in the new part and placed everything back to how it was, started the truck, and tried the eater, set there for a while, even took a drive and it still is not working properly.

  • @juniorsaloman2242
    @juniorsaloman2242 2 роки тому

    You forgot to plug it back up the actuator

  • @coreydavis7431
    @coreydavis7431 7 місяців тому +1

    Not accurate. I followed this video step for step. The dash has to come off!! The screws are in tight spot. If you notice he said, “after finally getting the screws out”. Exactly!!!!

    • @kolap4556
      @kolap4556 6 місяців тому

      Can’t get the last swcrew out about to break it

    • @yandresaviles2415
      @yandresaviles2415 6 місяців тому

      lol just did it this way. Dash does not have to come out

    • @NickW90
      @NickW90 13 днів тому

      You need to give up your tools and go to a shop. I just did this following the instructions in the video. It took me 20 minutes only because I lost the back bolt and had to fish it out.

  • @Yaboii.Drewskii
    @Yaboii.Drewskii Рік тому

    That man on the left think he’s too cool for the camera

  • @mclifer
    @mclifer 7 місяців тому

    Or buy a used Toyota and forget about replacing parts that should not fail.

  • @ShaneHolly
    @ShaneHolly Рік тому

    I have replaced my blend door motor 20 times. With out fail after a few months it happens again. At this point i am wondering are there preset positions the motor have to be at? Preset temperature? Preset anything?
    There is an arrow at the bottom of the motor.. Is the key on the spline shaft supposed to be in line with that arrow? There has to be a reason my spline is jumping out or reason my door always eventually falls shut again ton blast heat relatger than my ac. Help.

  • @joshnoyes6119
    @joshnoyes6119 2 роки тому +8

    Can you have a bad actuator without any error codes? I have cold air and when turned to hot does not get hot.

    • @qbienemy4663
      @qbienemy4663 2 роки тому +1

      Did you happen to get an answer for your question because I'm dealing with the exact same thing. I plan to check the fuse tomorrow but in the meantime, if you have an answer please let me know. Thanks

    • @joshnoyes6119
      @joshnoyes6119 2 роки тому +3

      @@qbienemy4663 no but I went ahead and replaced it this weekend. Seems to have worked.

    • @qbienemy4663
      @qbienemy4663 2 роки тому

      @@joshnoyes6119 Thanks

    • @snowblind5151
      @snowblind5151 2 роки тому

      I have the same problem on my 2005. No codes ,tried to flush the heater core and made a big mess. Tried forcing air through both hoses and had air going through the head then up into the reservoir. When you changed out your actuator door with no codes did it work and are you still getting heat? Because I might try this.

    • @joshnoyes6119
      @joshnoyes6119 2 роки тому +1

      @@snowblind5151 seems to heat better but not like it should.