Trane VOYAGER Test Mode

Поділитися
Вставка
  • Опубліковано 29 кві 2020
  • Troubleshooting Trane AC using test mode,
    Beginners and pros how to use test function on Trane RTU ac units, to turn on every function without using the thermostat or it’s terminal block
    #tranehvac #d2dnyac

КОМЕНТАРІ • 17

  • @joshuaricks7730
    @joshuaricks7730 2 роки тому +2

    If you have wires connected to 1-14 you cannot jump at the conventional terminals. ( R G Y W C ) it set higher priority to the 5vdc circuit

    • @D2DNYAC
      @D2DNYAC  2 роки тому

      Ooh 👍 thanks for stopping by

  • @Bluecollarrebel
    @Bluecollarrebel 4 роки тому

    🤙

  • @joehead1294
    @joehead1294 3 роки тому

    Do NAVAC hoses have some sort of check valve in the hose, as there is no shut-off or does it not need it as it is not a manifold gauge.

    • @D2DNYAC
      @D2DNYAC  3 роки тому

      No check valve here, and this is an actual gauge and manifold! This gauge and manifold was geared towards mini splits being that they only have one service port.

    • @joehead1294
      @joehead1294 3 роки тому

      @@D2DNYAC Yeah, I guess I think manifold has more than one gauge, you are correct. Does it not need shut-off down at end of hose, Montreal Protocol?

  • @arminbrambila9118
    @arminbrambila9118 2 роки тому +1

    I put a jumper between Test 1 and Test 2 It worked ok, and I did it again and the Electronic Board Turned off, I can't see the leds flashings, I had to disconnect and comect the electrical supply and then the board turned on. What happened here? Thanks

    • @D2DNYAC
      @D2DNYAC  2 роки тому +1

      If you are using the screw terminals they may be corroded so it's a hit or a miss best to go behind! And if not then the unit may have a control short on either economizer, HEATING or cooling circuit, so I would do it test again and pay close attention to what stage or mode of test the led goes out ie fan, economizer, HEATING cooling etc

  • @JuanSanchez-nn1db
    @JuanSanchez-nn1db Рік тому

    What model of Navac gauges are those?

    • @D2DNYAC
      @D2DNYAC  Рік тому +1

      i will let you know

  • @jractk
    @jractk 3 роки тому

    Put the door on over the compressors when reading pressures!

    • @D2DNYAC
      @D2DNYAC  3 роки тому

      Sure that’s the correct way to do it

  • @richardreynoso7260
    @richardreynoso7260 3 роки тому +1

    I got circuit 1 compressor do not started
    help

    • @D2DNYAC
      @D2DNYAC  3 роки тому +1

      Got to give me more information than that! If u need me to help

    • @phillipsierra2074
      @phillipsierra2074 3 роки тому +2

      Find a professional

  • @globaltecnicianworldsbest3031
    @globaltecnicianworldsbest3031 4 роки тому

    What's reliatel?

    • @D2DNYAC
      @D2DNYAC  2 роки тому

      Tranes control board inside its smaller RTUs that's capable of using standard non trane thermostats