Warehouse design Parameters | Staad Pro

Поділитися
Вставка
  • Опубліковано 29 січ 2025

КОМЕНТАРІ • 35

  • @azmat_waseem
    @azmat_waseem 4 роки тому +1

    Very Informative.... Thanks....

  • @mainuddinfaisal4532
    @mainuddinfaisal4532 4 роки тому +1

    Good Job Boss.

  • @sankalpagrawal9868
    @sankalpagrawal9868 4 роки тому +1

    Sir, agar hum built-up column lete hai say 2 - C channel, then will there be any change in Ly Lz parameter, as we would apply beta 90 degree there to reorient the column.

  • @sndesigncentre4011
    @sndesigncentre4011 4 роки тому +2

    Sir aap is series me connection design bhi sikhoge aap

  • @QualityStructurals
    @QualityStructurals 4 роки тому +2

    Dear sir
    Can you pls make a video of mezzanine floor in steel
    Thanking you sir

  • @abhishekvaish2355
    @abhishekvaish2355 4 роки тому +1

    Great sir, thnks

  • @ymv9741
    @ymv9741 4 роки тому +1

    Good sir

  • @sathishkumarm8799
    @sathishkumarm8799 4 роки тому +1

    Sir , please upload analysis of EOT Crane in steel building

  • @sndesigncentre4011
    @sndesigncentre4011 4 роки тому +1

    Nice

  • @sureshkumar-ji5kn
    @sureshkumar-ji5kn 4 роки тому +2

    Sir,Can you pls explain
    What is Lx parameter ?? Why we assigning Lx parameter?
    In older videos ly and lz only mentioned

    • @SteelDesign1
      @SteelDesign1  4 роки тому +1

      lx is unbraced length for flanges only. used for the Flexure(bending) members only.

    • @sureshkumar-ji5kn
      @sureshkumar-ji5kn 4 роки тому

      @@SteelDesign1 okay sir

    • @sureshkumar-ji5kn
      @sureshkumar-ji5kn 4 роки тому

      @@SteelDesign1 so Lx and Ly have same value?

  • @shreyakhandelwal8853
    @shreyakhandelwal8853 4 роки тому +2

    Sir please upload the next video on this topic.

    • @SteelDesign1
      @SteelDesign1  4 роки тому +2

      Sure Er. Shreya. you will get by tomorrow.

  • @ashutoshyadav5104
    @ashutoshyadav5104 3 роки тому +2

    Can you please share link for videos related to parameters

  • @shakirtechnology6633
    @shakirtechnology6633 Рік тому

    Sir parameter ka video konsa he Jo apne bola he

  • @rajithpatelrg5855
    @rajithpatelrg5855 Рік тому

    Sir for the rafter Ly and Lz were 1.5 my but why you provided Lx has 1.5 mt

  • @theummat1975
    @theummat1975 Рік тому +1

    Sir maine do baar playlist khatam kar diya lekin same error aa raha hai "Run Analysis" karne ke baad ek error aa raha hai wo ye hai " ERROR NO ACTIVE LOAD CASE IS PRESENT FOR IS 800:2007 STEEL' DESIGN." Plz help

  • @mohammadmujtaba5185
    @mohammadmujtaba5185 4 роки тому +1

    First comment

  • @ashutoshyadav5104
    @ashutoshyadav5104 3 роки тому

    Sir link for video explaining parameters is not available

  • @azmat_waseem
    @azmat_waseem 4 роки тому +2

    What about Parameters like Fu, FLYD, etc.,. u have not assigned???

    • @SteelDesign1
      @SteelDesign1  4 роки тому +1

      by default staad consider fyld 250 MP & FU 420 Mpa. these parameter we will define during optimisation of steel. :)

    • @azmat_waseem
      @azmat_waseem 4 роки тому

      @@SteelDesign1 Okay....

  • @AbhishekVerma-yx2dv
    @AbhishekVerma-yx2dv 3 роки тому +1

    Love you

  • @nileshpatil8118
    @nileshpatil8118 4 роки тому

    Sir please upload next video please...we are waiting

  • @adeshkumar3532
    @adeshkumar3532 3 роки тому

    Sir why you have not assign UNB and UNT.

  • @satishbarfa5888
    @satishbarfa5888 2 роки тому

    Plz share link for parameter like lx ky

  • @chanduthakur4631
    @chanduthakur4631 3 роки тому

    Hi