Seismic analysis As per IS1893 2002 in Staad Pro best explained

Поділитися
Вставка
  • Опубліковано 17 лис 2024
  • To watch entire training series of Stadd pro V8i .....Kindly subscribe the channel.......If you need any particular topic ...then kindly tell the topic in coments....

КОМЕНТАРІ • 91

  • @guptasagar694
    @guptasagar694 6 років тому +3

    sir please can you make video on" analysis of multistorey building with shear wall"

  • @GrazUralKamaz
    @GrazUralKamaz 3 роки тому +1

    Really appreciate your efforts... Thank you

    • @Jags22079
      @Jags22079  3 роки тому

      Thank you dear for your motivating feedback.... please Like and Subscribe to support my channel

  • @nayansurvase5619
    @nayansurvase5619 6 років тому +7

    why the member weight 15 KN\m is provided during seismic definition

  • @showmitrabarua2555
    @showmitrabarua2555 5 років тому +1

    Helpful! Thanks from Dhaka

    • @Jags22079
      @Jags22079  5 років тому

      You are welcome 😊 .... please like the video to support me

  • @chetankumar9463
    @chetankumar9463 5 років тому +4

    Sir when i am clicking generate then a dialog box appear which says that 'creation Failed'. Please solve this issue.4:15

    • @sapnac3257
      @sapnac3257 5 років тому

      Yeah me too facing problem how to fix this ??

    • @waqarmukhtar7902
      @waqarmukhtar7902 4 роки тому

      Hi... please its problem in your staadpro software..plz download new and enjoy

  • @adamntium
    @adamntium 3 роки тому +1

    please explain abt seismic analysis of water tank structure in staad pro

    • @Jags22079
      @Jags22079  3 роки тому

      Sure.... Please Like and Subscribe to support the channel

  • @farazkhan2564
    @farazkhan2564 7 років тому +1

    well your video is good in short u explained almost all aspects but at the same time you should take a example of which u have manually calculated the answer so for the better understanding what is the error and what not.
    Thank You

  • @architectcreations5633
    @architectcreations5633 4 роки тому +1

    Sir 1893-2016 new code aaya hai use ke anusar kese load use karenge

    • @Jags22079
      @Jags22079  4 роки тому

      architect creations let me go through that .... after that i will post a video on that

  • @burhanadenwala6803
    @burhanadenwala6803 6 років тому

    How you consider the load of member weight ? What does UNI mean? It will be a very informative video if you would have showed the manual calculation else it is like we have to accept the values and when we do the same thing for our project, we are blank.

  • @sidduhussain8005
    @sidduhussain8005 6 років тому +1

    on what basis that you are taken member weight as 15 and damping ratio as 0.5
    can you please explain

  • @sidhuraj8417
    @sidhuraj8417 5 років тому

    Please say about warning in seismic loads after analyze the structure

  • @bhushandoshi1985
    @bhushandoshi1985 3 роки тому

    while generating the seismic forces it shows creation failed in that case what should i do?

  • @jagadeeshmalla2744
    @jagadeeshmalla2744 5 років тому

    sir why u don't consider seismic in -x & -z direction

  • @peoplespowerhellyeah8619
    @peoplespowerhellyeah8619 5 років тому

    upload a video about how calculate various loads for staad specially floor load and udl

  • @Rahul-ic2hh
    @Rahul-ic2hh 4 роки тому

    How you take pressure can you plz explain ,wich type of thickness you are taking about?

  • @meghnamore6608
    @meghnamore6608 8 років тому +1

    and also explain column and beam design in staad pro

    • @Jags22079
      @Jags22079  7 років тому

      +meghna more hey here is the video as u requested. ua-cam.com/video/2B9JWyU0QEk/v-deo.html
      Please share the video as much as u can

  • @ankursingh6233
    @ankursingh6233 6 років тому +1

    While giving member load UNI, how did you get the value 15? Please explain.

    • @burhanadenwala6803
      @burhanadenwala6803 6 років тому +1

      Even what does UNI mean?

    • @mystogan1186
      @mystogan1186 4 роки тому

      @@burhanadenwala6803 Uniform

    • @mystogan1186
      @mystogan1186 4 роки тому

      But what I'm not getting is how did he get 15

    • @ameen470
      @ameen470 2 роки тому

      @@mystogan1186 it is the weight of masonry wall on each beams

  • @MohsinKhan-tj2xo
    @MohsinKhan-tj2xo 5 років тому

    Sir what about dead load of building and live load
    Again what about load combinations

  • @anamasar511
    @anamasar511 5 років тому

    While defining member weight .....why do you choose UNI what does it mean

    • @surojit_ghosh
      @surojit_ghosh 3 роки тому

      It is Uniformly Distributed Load with with same load intensity at start and end point. Normally it is used to represent the weight of the wall.

  • @malyvlogs
    @malyvlogs 7 років тому

    sesimic analysis and design G+20 multistorey buliding by using STADD.pro

  • @meghnamore6608
    @meghnamore6608 8 років тому +1

    Tysm sir 😊 for proper explanation.

    • @Jags22079
      @Jags22079  8 років тому

      meghna more u r welcome .....I have a complete training series of Staad pro tutorials on this channel... if u feel any problem u can ask for help on monimalikn73@gmail.com ......kindly share the videos as much as u can on Facebook and WhatsApp with your friends

    • @meghnamore6608
      @meghnamore6608 8 років тому

      +Jags 22079 okay sir 😃😃😊 ty

  • @engineermohammedsoyebbadgu3714
    @engineermohammedsoyebbadgu3714 6 років тому

    What about Damping Ratio ???

  • @nandusprakash4331
    @nandusprakash4331 3 роки тому

    Where did you get the member weight as 15kn/m

    • @surojit_ghosh
      @surojit_ghosh 3 роки тому

      I think it is specified to consider the weight coming from the wall as UDL -- (3.3m wall height - 0.3m beam depth)*0.25m exterior wall thickness*19.2kN/m3 unit weight of brick wall - roughly 15kN/m.

  • @atikahasfi6590
    @atikahasfi6590 3 роки тому

    Hi, may i know how your 'output viewer' shows the results by level/metre? Because mine shows the results according to node and beam which im not sure those belongs to which height since my structure has 33 floors height. Its hard for me to analyse by one by one

  • @guptasagar694
    @guptasagar694 6 років тому

    Sir beams aur columns ko koi property assign kyu nahin ki...jaise purane videos me karte he..bina property assign kare hi sesismic loads laga diye

  • @gilitato697
    @gilitato697 4 роки тому

    Bro,
    I can see the other result but unable to find a lateral force distribution of each floors in output result. I have applied all the parameters as you shown in this tutorial. Please, suggest , how to rectify?

  • @suliman9058
    @suliman9058 5 років тому +1

    Please i want tutorials on IBC OR asce analysis on staad pro

    • @Jags22079
      @Jags22079  5 років тому

      Sure ....kindly give me some time to make that video for u ...... kindly subscribe and hit bell icon so that u get notifications when I upload that video

  • @omgomase84
    @omgomase84 4 роки тому

    How to define mass scource for live load like for LL=3kN ---0.25% and above 0.5%

  • @nirmalraj8303
    @nirmalraj8303 5 років тому +1

    What method of seismic analysis is this ? If it is static analysis, it is either 'Equivalent static analysis' or 'non linear static analysis (pushover analysis) ? Please respond, sir !

    • @Jags22079
      @Jags22079  5 років тому

      Watch this
      Seismic design using Interactive Design in Staad Pro ua-cam.com/video/XijrffDmer0/v-deo.html

    • @Jags22079
      @Jags22079  5 років тому

      For dynamic analysis Response Spectrum Analysis (Dynamic) in Stadd Pro v8i on IS1893 Best explained ua-cam.com/video/KcrVbkxW5_c/v-deo.html

  • @americanunchimeeani2938
    @americanunchimeeani2938 7 років тому

    my project is on sesimic analysis of prestressed concrete frames

  • @RAHUL-kp5pn
    @RAHUL-kp5pn 6 років тому

    Sir can you please tell me if base isolaters can be provided in stadd pro?

  • @hasanshirazi9535
    @hasanshirazi9535 6 років тому +2

    @ 7:52 why you give damping ratio as 0.5%? It should be 5% for RCC structures.

  • @beenay18
    @beenay18 5 років тому

    how would steel bars effect the modulus of elasticity of concrete section? I need the moment of inertia and modulus of elasticity of reinforced concrete section with effect of percentage of steel. actually I need it because I need stiffness of column to calculate the stiffness of whole story of the building. I modeled a RC building in etabs. etabs gives me stiffness of the story after I run the analysis. but i haven't even run design. How did it calculate the story stiffness even before the reinforcement percentage in column is determined. Is it calculating stiffness of columns with no reinforcement in it ? or is it calculating stiffness of column with minimum required percentage of steel? will it change the stiffness of columns and then the stiffness of whole story after I run design in accordance with the amount of steel it calculates for each column? is the stiffness of the whole story sum of stiffnesses of all the columns of that story?

  • @mohdjunaid7011
    @mohdjunaid7011 6 років тому

    hello sir in my staad pro when i click generate is showing creation failed ...plz help wht should i do.

  • @2kmoments683
    @2kmoments683 5 років тому +1

    Water tank Mai kese lagayege? Seismic load

    • @Jags22079
      @Jags22079  5 років тому

      Same way

    • @2kmoments683
      @2kmoments683 5 років тому

      @@Jags22079 yr building alag structure hota hai or water tank different to atleast bto yr kese krna hai water tank mai

  • @meghnamore6608
    @meghnamore6608 8 років тому +1

    sir pls explain introduction to fem

    • @Jags22079
      @Jags22079  8 років тому

      +meghna more sure dear just give me some time

  • @Souvik62674
    @Souvik62674 4 роки тому

    Can you suggest me how to get full version of staddpro coz every time it only give 7 days trail even after following all steps to activate ??

    • @Jags22079
      @Jags22079  4 роки тому +1

      I have uploaded a new video for that .... please follow it ... it is happening because of you have some file left of your previous installation

    • @Souvik62674
      @Souvik62674 4 роки тому +1

      @@Jags22079 thnx

    • @Jags22079
      @Jags22079  4 роки тому +1

      Please like the video to support

  • @raviteja3140
    @raviteja3140 7 років тому

    hi , in the seismic definitions you have given member weight as 15kN/m2 . what is this value actually ?? kindly write to me

    • @burhanadenwala6803
      @burhanadenwala6803 6 років тому

      I guess it is total weight of all the members excluding slab divided by the plan area.

  • @tirtharajishore8033
    @tirtharajishore8033 5 років тому

    Sir i have a problem. The problem is that after doing analysis staad showing that " udl is not define for member 3 or 4 etc......" so what is thr problem ? And how can i remove it???? Sir please help me.

    • @Jags22079
      @Jags22079  5 років тому

      I can’t suggest anything with the information u have provided .... i need to see the model

  • @praneethajogi1286
    @praneethajogi1286 5 років тому

    dont we need to apply dead load??

    • @Jags22079
      @Jags22079  5 років тому

      Surely we need to apply .... but i was just focusing on the seismic part

  • @ankitapatel3233
    @ankitapatel3233 5 років тому +1

    SIR HERE ONE THING PLEASE EXPLAIN ME WHY YOU ARE PUTTING HERE MEMBER WEIGHT 15KN/M IN SEISMIC LOAD

    • @Jags22079
      @Jags22079  5 років тому

      Its a rough assumption

    • @RahulKumar-wc2hh
      @RahulKumar-wc2hh 4 роки тому

      @@Jags22079 Wrong bro You should learn is 875 all 5 part .....Thast is dead load of the the building then + 50% of live load

  • @shankardebnath933
    @shankardebnath933 2 роки тому

    please shear earth quake resistant rcc chimney design 300 m

  • @mukundkrishna5161
    @mukundkrishna5161 3 роки тому

    Damping ratio is 5% itself. Why have you changed to 0.5%?

  • @motospoin
    @motospoin 8 років тому

    how to calculate member load ?

  • @gaganmwanted
    @gaganmwanted 8 років тому

    Sir during loading....staad will automatically calculate the slab load or we have calculate it?
    You assign the slab load during seismic load in this video

  • @goldyakash
    @goldyakash 7 років тому

    sir can you please explain the design of a cooling tower with all the essential loading (dead load, live load, static and dynamic seismic load, wind load. i will b very grateful. I have also sent you an email. please help me out here sir.

  • @farhadnekonam1298
    @farhadnekonam1298 7 років тому

    Thanks

  • @Vaibhav-vt3bt
    @Vaibhav-vt3bt 5 років тому

    Bhai , voice bhut thodi hai , jor se bola kar thoda