Ram Pump Delivery Pipe Closed at the Top

Поділитися
Вставка
  • Опубліковано 28 чер 2024
  • The Ram Pump delivery pipe can be closed at the top of the delivery while the pump is running. This will cause the pump to cycle without an output and the pressure tank will build full pressure allowed by the input head pressure. If there is not enough lift out to maintain back pressure the pump will stop when the delivery pipe is opened at the top after pressure has been built up in the line.
    Buy a Ram Pump at the Land To House Store:
    landtohousestore.com/
    Ram Pumps available on AMAZON
    amzn.to/2EWrQHN
    Help Support land To House by Paypal:
    paypal.me/landtohouse
    Send Mail to Land To House:
    Land To House llc
    P.O. Box 323
    Micaville, NC 28755
    See whats coming up before it hits UA-cam on my Facebook Page:
    / landtohouse
    Land To House is a participant in the Amazon Associates Program, an affiliate advertising program designed to provide a means for sites to earn advertising fees by advertising and linking to amazon.com

КОМЕНТАРІ • 13

  • @TradisionalChannel_Indonesia
    @TradisionalChannel_Indonesia 14 годин тому

    simple... but extraordinary benefits

  • @jllaine
    @jllaine 4 дні тому

    Nice demonstration, thank you.

  • @hayderalsalman7984
    @hayderalsalman7984 6 днів тому

    Good job now you need to do same cable and pipe arrangement inside Trench 🎉 in future as you saied

  • @jayjay6804
    @jayjay6804 6 днів тому

    The difference is because when the 'static' pressure is changed to 'dynamic' pressure it is enough to cause an imbalance in the system as you stated. However, the 'static' pressure will always be the same at the top of the delivery pipe and at the pressure chamber when the upper delivery valve is closed. It is a closed system at that point and pressures are equal throughout. Problems can be avoided by using a relief valve or a bleed off orifice at the top of the delivery pipe to avoid a static pressure situation. You can verify this by comparing two pressure gauges at each end of the delivery pipe and closing it off.

  • @dynamicdyna
    @dynamicdyna 4 дні тому

    you already try the waste valve is smaller i mean the you install the pump pipe is 1 1/2 and the waste valve reduce in 1inch diameter, thanks

  • @hayderalsalman7984
    @hayderalsalman7984 6 днів тому

    Can we use two pressure tank on the same ram pump and can that increase head

    • @LandtoHouse
      @LandtoHouse  5 днів тому

      I ran a test on that a while back. It does not increase the output.

    • @RamPumpShop
      @RamPumpShop 4 дні тому

      The function of the pressure tank is to buffer vibration and store pressure through compressed air. Adding more pressure tanks can only make your ram pump vibrate less when running. But it will not increase the head or water output~

    • @workbenchz
      @workbenchz 4 дні тому

      Without a pressure tank, the pump has to push all the water in the delivery pipe uphill all at once and that is a lot of rest inertia to fight. The air space in the tank compresses allowing more water to rush into the tank and then slowly push the water uphill. Two tanks or a larger single tank can allow more air space to be compressed and more water enters the tank, but only up to a point.

  • @davebaldwin7218
    @davebaldwin7218 5 днів тому

    Soo.. I'm about to purchase the 3/4 to 1/2 del.
    What is the best way to stop water flow without having to restart pump

    • @LandtoHouse
      @LandtoHouse  5 днів тому

      You can stop the pump from the top of the delivery as long as you have enough lift. In this example I had the delivery pipe right at the lowest possible point to demonstrate the loss of pressure.

    • @davebaldwin7218
      @davebaldwin7218 5 днів тому

      @LandtoHouse I will have about 65 ft of lift from creek up a bluff. I was worried it would be too much lift

    • @RamPumpShop
      @RamPumpShop 4 дні тому

      @@davebaldwin7218 The water outlet shutoff does not affect the operation of the rampump. If you are worried about too much pressure, you can install a safety relief valve on the rampump like I did. When the water outlet shutoff pressure exceeds the set value, the safety valve will open to discharge the high pressure.