WHAT IS RCC FLAT BEAM / HATCH BEAM ON OLD SLAB (पुरानी छत के ऊपर नई बीम कैसे डालें)
Вставка
- Опубліковано 2 гру 2017
- hello dosto... i am aman singh i am talking about in this video...
what is RCC FLAT BEAM OR RCC HATCH BEAM ...
agar aap ke ghar ke slab purani hai aur aap ko us slab ke upper room banane hai aur planning bhe change ho ground floor se tb aap apne ghar me is type se beam daal sakte hai ....
is video me ye ghar pura 230mm,9inch ke wall pe bana hua tha aur 1st floor ke planning chang krne the to new column daal ke phir slab se joint krke upper nikala gya hai ... aur slab ke upper he 4-5inch ke beam banaye gye hai.....
Thanks sir,AAP ki vjh se mujhe apna ghar banane me kafi mmd mil rhi hai.... praveen Kumar Singh
AAP se sujhav hetu ,kis tarah bat ho sakati hai.
Aapne bahut achhi tarh she samjhaya hatch beam me bare me dhanyvad
Thank u sooo much sir u clear my doubts thank u sooo sooo much 🙏
Thanku so much sir mujhe apki video bot Jada smjh me ati h 🙏
Sir bhut achha lga video ,👍👍👍
Boht achaa nice
good engg.
good work. loads easly transfer to columns and and footing
Very nice video something different
Interesting.
Mera Ghar 2018 me bana,jisme column aur pillers hai,nichey beam h but upar beam ni pada h...
Bahar ki deewar 9inch ki hai, but Andar ki deeware 4 inch hi hai...
Ab jab mujhe in chijo ka knowledge hua toh man bahut dukhi rahta hai,ye sab soch kar please mujhe kuch upay bataye ki mere ghar me majbuti aa sake
Very informative video. Thanks bhai jaan
Nice sir aapki baat hi nirale h
Bhut ache sir
Very nice sir
Sir mai ek architecture student hu or apki video se mujhe bht knowledge milti hai 😊
Thanks bro...
Kaha se ho..aap
Mai bhi 1 architecture student hu sir 😁 or ap ki videos bahut help krti hai service ko theeek se smjne mai madat milti hai thanks sir
Cement Ka set say ghar ha Mara usko slabe kaisa dala ja tha ha beam nai ha big heant Ka dewal ha
Aap ko agar khabi moqa mily is tara k kaam karny ka to plinth beam zaroor lagwana
Ye bhai sahb ne pilnth beam nai lagway hein
Very important information...
Thank you very much... Big brother
... Radhe Radhe jai shree Krishna ji 🙏
thanks bro...radhe radhe...
Very nice
Aap ke sare video helpful Rehte Hain.
Nyc vdo
Great sir.
We are going to have such modification. This is helpful..
Nice sir.
Bahut badhiya ....
बहुत अच्छा वीडियो
Best knowledge video 👌
Sir tell me about which filler material we use to make floor and hidden beam at same level .
Informative video 👍🏻
guys, kuch cheeze nazar andaz kare gayi hai??
suprb demonstrationsir! you let me clear all doubts in a moment ,only thing plz let me know how to relocate the bathrooms also in same floor
Very good information sir just👍🏻👍🏻👍🏻
Sir ji...Mera 15 × 30 aria me garder fharsi ka grund flour bana hua he jisme ek room , kitchen and let bath bane hue he . 8 inch ki wall he . Hum ground floor ko toch kiye bina first floor bana sakte he kya ? 2 room with RCC chat . Please suggest kijiye 🙏🙏
Sir, how to provide cantilever slab for balcony in this type of house. Please give answer, I am watching your every video.
Wont providing a hatch beam and filler materials add additional load on the slab?
Agar ek colum kiye hua ghar ko extension Kiya Jai tab Chad ko kyase jode. Ghar do floor ka hai. Please bataiye
Hi,Please let me know the scientific method of connecting an old roof which has no link on the wall to new roof adjoining to the old one, thanks
Wow, old house pe bilkul bhi load nahi hoga upar ke floor ka
Thank you making this video
Nowadays people use hatch beams instead of down beams..is it equally stable?
Very informative video.....Keeps going...
Thanks
Kya technically yah slab lot sear karega?
Kunki normally desi type ke house constitution work Mai people desi civil work karte hai, Es type ke jugad working ko nhi kiya jaye , Kunki yah dekhna hoga ki lend kis zone mai aata hai, or soil report Kya hai.
Thankyou very much sir 🌹 🙏 🌹
Sir isme jo chhat ke upar beam dali gaii h uska load or uske upar jo wall padegi in dono ka load chhat pe to padega hi..
Ha bro but bahut km... maximum load column me transfer ho jayaga...
Good information janab
can you add beam below an old roof, and build wall on top of the beam?
Nice
सॉइल फीलिंग के बाद रेत डालना है या इट के बाद रेत डालना अच्छा रहेगा
Thank you for video. Please tell me is hide beam safe ?? It's interesting design ,I like.
Sir lenter par. Room par Dewar laga sakte ha room lenth 11 feet ha window 8,feet. Lagana ha
Sir me video apka dekhta hun krpyaye batay ki niche se 2 feet upar beem wali d p c kaiae dale bena jyda dwae nuksanpahuchay aur beem kaise dale h am upar ka lenter tod kar 2 feet upar lenter dlna chah te he
Hlo sr old housr jismai column or bhim na ho us ghar ke upper construction .kaisai ki jaai bina lanter ko gira kr please rply
Hi dear my house is gatter + Patia ( red flat stone) not lenter How to create pillar and hatch beam over that plz advise me
Sir, can you please tell me..what are other alternative of khangar?? because it not available everywhere.
Coal lumps
bahut achha vidio hai
Bina chath dale ghar banwa chuki hun aur ab usse ghar ko tode bina chath dalwana chahti hun kya asaa krwana possible hai please reply me
सर, मेरा ग्राउंड फ्लोर 2016 में बन गया था और उसमें कॉलम तो पड़े थे पर लेंटर से पहले लटक बीम नहीं पड़ी थी, ग्राउंड फ्लोर की खिड़कियों और दरवाजों के ऊपर फर्श से 8 फीट की ऊंचाई पर डोर बैंड पड़ा था पूरे मकान में, उसके बाद 3 फीट की चिनाई हुई और सीधे ईंट के ऊपर लेंटर पड़ा गया। ग्राउंड फ्लोर के कॉलम लेंटर से ऊपर 2 फीट निकले हैं, अब फर्स्ट फ्लोर की प्लानिंग चल रही है, ग्राउंड फ्लोर के कॉलम के साथ हम फर्स्ट फ्लोर के कॉलम खड़े कर रहे हैं, पर अभी उनमें कंक्रीट नहीं भरा है, तो मैं यह पूछना चाहता हूं कि हमें ग्राउंड फ्लोर के लेंटर के ऊपर हैच(फ्लैट) बीम देनी पड़ेगी या नहीं।
और सर हमारी ज्यादातर दीवार तो नीचे वाली दीवार के ऊपर ही आ रही हैं पर 3 दीवार ऐसी है जो नीचे वाले कमरों के लेंटर के बीच में आ रही है तो क्या करें?
Sir please reply fast......... urgent
भाई साहब concept आपका बोहत अच्छा था बस दो बातें कहना चाहूंगा , एक तो 5:28 पर देखिएगा जो beam है आपका वो column से out है जो की गलत है , beam एकदम center में होना चाहिए और दूसरी बात आप इसमें अगर rcc ceiling ( 12 mm 6" x 6" रिंग , single layer) देते तो ज्यादा अच्छा होता , छत का सारा लोड उस पर आ जाता |
Sir mujhe 1st floor pr ground floor sedifferent portion bnaana pr mistri bol rha h k nai wall k uper hi wall uthaayi jaaegi ,sir pls helo me sir
Hello sir how are you aap Bohut Achi video bante very nice zabardsta thanks very much information dene k liye
Fine bro .. thanks
nice information. keep it up . thanks.
Very informative....👍👍👍
I want to make first floor construction
But ground floor only six pillers 9*9
Out side only
Can I make first floor construction on ground floor already made
Please arrange to advise
I hope you will accede to my request
Sir ,, humare makan 100 gaj ka h or humne column nhi lagaye the , kya deewar ko kaat kar column lag sakte h jise apne is video me dikhaye ...or sir please yeh bhi bataiye ki 100 gaj ke ghar me 9 column lagwane par kitna khrach aata h please sir jarur batana .....apka channel bahut acha h
Very nice video
nice
Charo side pe hatch lagage v kiya ja sakta tha, partition wall ko 5inch rakhne se problem hoti kya
Agr slab ki cutting kr k kren gy to ground floor ki slab ki strength kam ho jay gi plz ans me
Beams weren't enough as it would have rested on ground floor walls? Why columns were constructed?
Teen manjili bangeya kya esye type karke naya pillar dey sakta hu majbhoot key liye, sir
Toh hum is tarah ki beam ka use achi finishing k liye bhi kar sakte hain
Hatch beam kya hota hai aur kaha use hoti hai ispar ek pura video banaiye
Ok
sir RB linter po hachmi beem dalko kahi sai bhi wall ker sakte hai please reply
Sir kuchh column ke elevation machin se krte ha normal house ke liye usme kitne floor tk bna sakte ha
Sir please tell me which cement and steel brand name please for foundation..
Video bahut achchi thi
Jab hum footing k liye suppose 4'×4' ka area excavate karenge tab existing walls ka Kya hoga jo upar hai,isme to hmne sirf column wale area me hi wall todi hai
Pls explain
Hello sir... nice information. I had a doubt.... sir, insted of using conventional coloumns and beams, can we use ISMB 250 or 150... depending on the load above..? Even for the hatch beams, can we use same ISMB?. Please clarify.
Building lifting and shifting building main beams and columns dalwai=6201962545
Maine cantilever pe edge beam nehi to aisa kar sakte hai 1st floor pe
भाई साहब यदि ग्राउंड और फर्स्ट फ्लोर पर 9 और 14 इंच की दीवारें हो तो क्या हम छत पर हैच बीम को नीचे की दीवाल पर रेस्ट कर के कहीँ भी दीवाल उठा सकते है?
,
Very good information
Ashish Kumar Prajapati thanks bro
Sir mai bhi110 saal puraane makaan me chat par kmre. Banwa raha hu , thekedar ka kasa padta hai ki upR kamre ki base me jaala aur jumper .Plus beam ke bich me taaki upar ka l.oad nichr naa. A ye haalanki upar kamre ban a chuka hai abhi ties aur palastar baaki hai niche koi problem na ho kya karu
sir kya aap plan bhi banate ho ghaer ke 30x60 ka plot hai
Gyap bharneke ke liye hankar low weight ka material kon sa hota hai
Is there any connection between slab and beam?
Aap ne falor m kya bola light wat daalte h jo uska name batana
This beam needs more filling... For clear floor... The dead load on the roof is massive I think
Can I make only one partition wall 5” 12 feet long on roof where there no wall below I’m adviced to make only flat beam on roof without pillers from ground floor pls sir reply I’m in too much confusion what to do.
Kia is beam ka aik corner free reh sakta means cantilever??kion kay video may hatch beam free hay balcony ki side say mean kisi colum say connect nai hay..??
hi sir first floor Pai kaam kara raha hu RB linter hai uspai ground change kerke room banjayge
Sir ji mujhe bhi 10*11 ke room ko 15*15 ka banan hai ban jayega jagah hai sab hai aap idia btaiye
Thnx sir
iske upar aap kitni floor or bna skte h hatch beam ke upar. yeh bhi kam normal beam ki tarah kregi. ya uske comparison mai kamjor rhegi.
Hy sir.... Ek band makan h to..... Usme ek L type ki diwar h to..... Usko thod k.... Mkan k aaage bnani h........ Kuch btaye sir... Plzzzz
Flat beme 2 feet dal kar usko fhiling kar sakhte hi
sir ek question h aapse ye aapne jo hatch beam ground floor ki slab se uper 6 inch uthai h...m beam uper nh lejana chahta toh beam ki width k equal slab ko todhkar fr jab slab ka reinforcement dikhne lge usi reinforcemnt par beam ki bars niche ki side tie krke beam ko niche hi cast kru aur dono side column se support krna chah raha hu ..ye thk rahega.?????????.i hope you got my question....ye m bas ek room ki width badhana chahta hu...islye krra hu baki deewar k uper deewar ayengi first floor m....i wnt your suggestion...i will wait fr it.. although from my side i have done all the calculations..i want to clear my doubt
Sir garder Farsi ke makan pr chat kese dale bataiye please
Waiting for this video...bro
Nice video
15 *36.. 1993 years old house h. 8 pillar h. 9inch k. 12 m.m.k 6. bar h. Side m dono side house h... Jeck nahi lag sakta. Is par kitne floor or bana sakty h. Abhi ground flor hi h. Road se 2feet doun h. Plz help. & suggest
Sir beam me steel bar ka kya Dia hai
9"x9" ke pillar me 4 se jyada bara dalna galat hai
Balakni chhaja kaise andar lete hai bumbaime balkni abhai nhi hai ghar bda karneke luye chhaja kaise andar lila jata hai ye btao. Or kitna kharch aata hai. Pl.
Sir es mkan Ka Pura video Daliyaga
Sir nice information .....mere Ghar me vertical beam hai par horizontal beam nahi Dale hai Abi to ground floor hai lekin upari manzil banani ho to Kase beam provide Kare
Thanks a million for the informative video even though I don't understand (Hindi?) I kind of got the hangs of the topic.
Would you be able to share how far are the columns from each other, their dimensions and how deep they go in the group (footing).
Once again thanks a million.
Bim ke uper gate lagega to uncha ho jayega na pharsh se
Good knowledge
Old building me hall banana ho? Kya kre ? Aur ooper home?
Good job