Differential Relay Testing (Micom P643)

Поділитися
Вставка
  • Опубліковано 21 жов 2024

КОМЕНТАРІ • 20

  • @Technicalguy_123
    @Technicalguy_123 Рік тому

    Sir i have doubt that we need to inject HV LV value after multiplying with matching factor?
    Or without matching factor as relay will multiply with matching factor internally?

    • @relayprotectionelectrical
      @relayprotectionelectrical  Рік тому

      Go through the playlist for differential relay. I think you will have clear Idea about above
      ua-cam.com/play/PLawO3DDAIgHGsFxFjkech1CgGBWgArtok.html

  • @Kiran-nb5xi
    @Kiran-nb5xi Рік тому

    Very nice 👌

  • @surendrakverma555
    @surendrakverma555 2 роки тому

    Very good. Thanks 🙏🙏🙏🙏🙏

  • @mkhoirun918
    @mkhoirun918 10 місяців тому

    When Id is set to 0.3 In, what is In here? since transformer has 2 In. first In for LV side, second is In for HV side

    • @rjshtk
      @rjshtk 8 місяців тому

      For HV side, In will be the full load current of HV side expressed in secondary terms. Similarly, for LV side, In will be the full load current of LV side expressed in secondary terms.

  • @happysingh-gk2dj
    @happysingh-gk2dj 2 роки тому

    Hello sir, I designed a differential relay , I want to discuss with you .how can I contact with you

  • @ravindrayogi3196
    @ravindrayogi3196 Рік тому

    Why we take is1.002 and is2 3pu and k1 is 30 % and k2 50% .how it comes

    • @relayprotectionelectrical
      @relayprotectionelectrical  Рік тому

      Is1 is set as minimum as possible in order to give sensitivity to differential relay but it is so chosen that due to mismatch of tap position it should not operate. Again next slopes are given to maintain stability due to through fault. You can go through video ua-cam.com/video/9sc9WsiqmA4/v-deo.html

  • @souvikdasgupta6363
    @souvikdasgupta6363 2 роки тому

    How did u get end section 1 value as. 67?

  • @ranjansahu2362
    @ranjansahu2362 3 роки тому

    Well done sir

  • @anilshemade6048
    @anilshemade6048 3 роки тому

    Plz explain Is1 and Is2.

  • @sreehari2969
    @sreehari2969 2 роки тому

    how did you get 0.67 in chara. can you explain

  • @bablukumar-hz9nr
    @bablukumar-hz9nr 2 роки тому

    Distance protection relay testing and configuration pls sir

    • @relayprotectionelectrical
      @relayprotectionelectrical  2 роки тому +1

      Thank you for your comment. I will definitely upload video on Distance Relay testing and configuration.

  • @prabhakarrayalaseema333
    @prabhakarrayalaseema333 2 роки тому

    Very low voice