    Roger ‪@theheatingpro‬ How to set up demo for ESi Programmable stat. A longer video than usual but a lot to explain and set up on this stat from Esi. You can also find the pdf instructions at my website - www.cparkinson.com. Please as always post any questions and I will reply as soon as I can. Like and subscribe to my channel for more how to videos. Regards Roger

КОМЕНТАРІ • 590

  • @FIFAHERO90
    @FIFAHERO90 5 років тому +83

    Thanks for the video set mine up with ease! People like you who take the time to make these videos have all my respect 👍🏻

    • @JohnBobbit
      @JohnBobbit 3 роки тому +4

      I second this
      The manual was useless and I was getting really annoyed. Thanks for the video

    • @theheatingpro
      @theheatingpro  3 роки тому +1

      @@JohnBobbit
      Thanks for the comment John much appreciated.
      Any questions please let me know
      Regards
      Roger
      @theheatingpro.com
      Please Like & Subscribe

    • @Soniazaib786
      @Soniazaib786 Рік тому

      Hi anyone can help me how can heating on automatic 😔

  • @beckyzwhite
    @beckyzwhite 2 роки тому +4

    The manual (poorly written Chinese translated into poorly written English), leaves you scratching your head. Thank you God for sending us our thermostat saviour. Great stuff. xxx

    • @theheatingpro
      @theheatingpro  2 роки тому

      Thanks Rebecca,
      New one for me "The Thermostat Saviour" lol.
      Glad to have helped and any questions let me know
      Regards
      Roger
      @theheatingpro.com
      Please Like & Subscribe

  • @graysworldyeahyeah4157
    @graysworldyeahyeah4157 5 місяців тому +4

    Thankyou, nowhere does the manual explain that P2,P4 and P6 are the off times...now I understand it much better. Thanks for taking the time to explain

  • @jondavies1376
    @jondavies1376 Рік тому +7

    Thanks so so much for taking the time to help people like myself who lost the original booklet! You explain everything so straight forward, thanks again 👍

  • @susan4055
    @susan4055 2 роки тому +9

    Thank you ver much, gas fitter left me without instruction booklet after I said was struggling to set up timer. Found it too complicated anyway. You have explained it in easy language and I successfully set all my timers. What a godsend. You have saved my sanity. Please keep up the good work. If any gas heater making reading this, give this man a job and make people’s life’s less stressful !!!

    • @theheatingpro
      @theheatingpro  2 роки тому

      Susan
      Glad it helped, do try and make things that little bit easier
      Regards
      Roger
      @theheatingpro
      Please Like & Subscribe

  • @RachelByford
    @RachelByford 11 місяців тому +3

    Thank you. Life saver! So much better to watch someone knowledgeable explaining it simply.

    • @theheatingpro
      @theheatingpro  11 місяців тому +1

      Thanks for the kind words. please Like and Subscribe

  • @deepmidwicket
    @deepmidwicket 8 місяців тому +2

    Mine was messing up and this has SAVED ME cannot thank you enough!

  • @Gomgom-g1e
    @Gomgom-g1e 11 місяців тому +2

    Thank you so much! This was just what I needed right now. You can't beat watching the operation in order to understand fully 👍😊

  • @alexbrown1052
    @alexbrown1052 3 роки тому +5

    Brilliant step by step guide on how this works. The manual was information overload. Simple to follow and easy to understand. Thank you !!!!

    • @jakekraweckyj2801
      @jakekraweckyj2801 2 роки тому

      100% agree! Really struggled with that manual 😂

  • @mariabatchelor8559
    @mariabatchelor8559 Рік тому +1

    Fabulous instructions. Clear, precise, well spoken and not full of ‘umm’ and ‘errr’! Helped me enormously. THANK YOU!

    • @theheatingpro
      @theheatingpro  Рік тому

      You're very welcome! I'm glad I could be of help. If you have any further questions or if there's anything else I can assist you with, please don't hesitate to ask

  • @shabsjay9788
    @shabsjay9788 5 років тому +9

    Hi thank you so much for a very clear step by step instructions. I've just had this boiler installed 2 days ago and this has completely made my life easier in figuring out how to use the thermostat.

  • @szilviaszabo8057
    @szilviaszabo8057 6 місяців тому +1

    Thank you so much we are pushing it back to set up as the manual looks too complicated. 😅 We’ve just moved in and first time we have this termostat. Once we pack everything from the heaters we will set it up with this help guide. 😊

  • @juliadinsdale8049
    @juliadinsdale8049 2 роки тому +4

    Thank you so much for this video. I’m sure I’m not alone in saying these things really stress me out and I had been putting off programming the thermostat because I simply couldn’t understand that (useless) little booklet it came with. You have explained this so clearly and patiently. I will be returning to this video every time I need to change the settings but that’s ok😊. Thank you again

  • @CMDRRustyDog
    @CMDRRustyDog 5 років тому +4

    You are the man ! Thank you for this informative and helpful video. I just moved house and this was the system I was left with and had no clue how to use it.
    Watching this video has made everything so very clear ! Awesome.

    • @theheatingpro
      @theheatingpro  5 років тому

      Rusty Dog Thanks for the comment, glad the video helped. Free to subscribe and a like on the video too would be much appreciated Regards Roger

  • @shereeellis6226
    @shereeellis6226 Рік тому +1

    Thank you so much. I moved into a property and didn't know how to work this. I do now! Perfect!

    • @theheatingpro
      @theheatingpro  11 місяців тому +1

      Glad it helped you out. Please Like and Subscribe

  • @yvonnefraser514
    @yvonnefraser514 10 місяців тому

    I just got a new boiler installed with this thermostat. Best explained video amongst others showing how to operate the thermostat. Thank you.

    • @theheatingpro
      @theheatingpro  10 місяців тому

      Glad it helped and glad you have now the "mastered the stat". Makes you feel like a genius when you can figure them out and get your heating on as and when you want it.
      Regards
      Roger@theheatingpro.com
      Please Like & Subscribe

  • @chrisshort3339
    @chrisshort3339 6 років тому +4

    Absolutely fantastic guide! I looked at my instruction booklet and was totally lost, but watching this it’s gonna be easy, can’t wait to finish work and get it set up 👍🏻😎👍🏻

    • @missmouse3
      @missmouse3 6 років тому

      Chris Short I agree this is far better to understand than the gobbledegook leaflet but Im not too impressed there isnt a definitive "off" time function!

    • @theheatingpro
      @theheatingpro  6 років тому +2

      Hi Chris, manufacturers instruction is the reason for me doing the videos. Hope it helps and please subscribe for further upcoming videos with helpful tips to get the most from your Plumbing and Heating at home.
      Regards
      Roger
      www.cparkinson.com

    • @chrisshort3339
      @chrisshort3339 6 років тому +1

      CParkinsonBuryLtd Set my thermostats up yesterday with ease after watching your video, now subscribed to your channel too!!

  • @MauriceNeedoff
    @MauriceNeedoff Рік тому +1

    Thank you for explaining this so clearly. I now feel more confident to set my Parent's thermostat.

    • @theheatingpro
      @theheatingpro  Рік тому

      Glad I could help! I love UA-cam and the way it helps, my small bit to share what i know

  • @julsmarie53
    @julsmarie53 5 років тому +5

    Thankyou so much, i just had a new boiler installed and was gi ven this thermostat, the engineer explained the settings to me but i forgot. I found this video very helpful.

    • @theheatingpro
      @theheatingpro  4 роки тому

      Thanks for the comments Julie
      Regards
      Roger
      Please Like & Subscribe

  • @louisepage1778
    @louisepage1778 3 роки тому +1

    Thank you so much, we were left with no instructions and no explanation from the installers (as they were late to watch the football.) You have saved my hubby from going mad at the thing, a life saver!

    • @theheatingpro
      @theheatingpro  3 роки тому

      Hi Louise Page,
      Glad to have saved your husbands sanity. Late to watch the football tells me the installers didnt know how to set it either (more common than you would think)
      Click Like and subscribe and you will always have this video to hand and feel free to ask any questions in the comments
      Regards
      Roger
      @theheatingpro.com

  • @denisedayman4355
    @denisedayman4355 5 років тому +1

    Just had this new timer for our boiler and the operating instructions are really poor...this video is a life saver! Fantastic thank you

    • @theheatingpro
      @theheatingpro  5 років тому

      Denise Dayman Hi Denise glad to hear that it helped you our Regards Roger

  • @cevans7119
    @cevans7119 11 місяців тому +2

    Lost my manual. This helped a lot. Good detailed video!

    • @theheatingpro
      @theheatingpro  11 місяців тому

      Thanks for the kind words. please Like and Subscribe

  • @physiolee1
    @physiolee1 5 років тому +6

    This was much easier than reading the manual ! Managed to sort our heating after delaying setting it up due to the instruction manual not being idiot proof :) Thank you 👍🏻

  • @MrSagsta
    @MrSagsta 5 років тому +3

    Thanks. Well explained. Saved me from obtaining a manual. Just had new boiler fitted 2days ago and gas Safe engineer said just use the + - buttons to adjust temp. When I asked about programming it he said don't bother as the toggle switch will break 😂😂

    • @theheatingpro
      @theheatingpro  5 років тому +3

      Thanks Raja. "Don't bother the toggle switch will break" translates into "I have no idea even though I am fitting for you!" Regards Roger

  • @michaelsummerell8618
    @michaelsummerell8618 Рік тому

    Thank you so much for taking the time and effort to demonstrate how to use this - I've just had a new boiler fitted with one of these installed, but was not shown how to use it, and the instructions are like double Dutch..... Thanks for helping!

    • @theheatingpro
      @theheatingpro  Рік тому

      You are welcome!
      Regards
      Roger
      @theheatingpro.com
      Please Like & Subscribe

  • @robertdinn6805
    @robertdinn6805 4 роки тому +2

    Thanks - a very useful video. I found the instruction booklet hard to follow (and left out some of the useful information contained in the video), so the filmed instructions were great.

    • @theheatingpro
      @theheatingpro  3 роки тому

      Glad it was helpful! Let me know of any other videos you would find useful
      Regards
      Roger
      @theheatingpro.com
      Please Like & Subscribe

  • @robertlunt-01147
    @robertlunt-01147 10 місяців тому

    Brilliant mate just had a new boiler fitted with this programmer,and I had no idea how to use it ,you have explained that brilliantly for me and I can now use it thanks a lot 👍👍👍

    • @theheatingpro
      @theheatingpro  10 місяців тому

      Glad it helped. Thats what the video is there for
      Regards
      Roger@theheatingpro.com
      Please Like & Subscribe

  • @litonali2994
    @litonali2994 2 роки тому

    Just got the boiler installed, your video makes it much easier to understand than the manual. Thank you 😊

  • @andreastevenson2173
    @andreastevenson2173 2 роки тому +2

    Thank you, made my setup so easy. Appreciate the time you took to help others

  • @JulieBlackwell-West
    @JulieBlackwell-West 8 місяців тому +1

    Thank you very much for your reply Roger, it does help a lot.

  • @dawnzdrodowski6995
    @dawnzdrodowski6995 5 років тому +1

    Helped out is an understatement! I have struggled with my new heating system since January - I now understand why.

  • @knittingpoppy
    @knittingpoppy 2 роки тому +1

    Thank you, I haven’t been able to set this since I got it, hopefully got it right now!

  • @shonapape4451
    @shonapape4451 2 роки тому +2

    Thank you so much for this video, it was really useful as I didn’t find the instructions very helpful

  • @786slizza
    @786slizza 3 роки тому +1

    Absolute legend. This is much much much better than the manual that came with the thermostat. Thank you soo much for the help

  • @NagaChitturi-w8o
    @NagaChitturi-w8o 3 місяці тому +1

    This is best video compared to other channel videos.

  • @bombertowtow4390
    @bombertowtow4390 3 роки тому +1

    Very easy and well explained video ….. thanks for your time and making it easier than a paper manual guide …keep up the great vids

  • @d.b.cooper1
    @d.b.cooper1 4 роки тому +6

    Wow thanks for this, The manual it comes with is shockingly bad & this is hands down the best video on this out there, cheers! Do most people opt for leaving it in the auto setting with timed setting or is the off- then manual setting when need common/ok to use? I ask as my engineer who put our new boiler in only bothered showing us the off-manual options.

    • @theheatingpro
      @theheatingpro  4 роки тому +1

      Charlie Hi Charlie, thanks for the comments, much appreciated. As per leaving in auto or manual, the best way is to work for your own needs. Personally this time of year I set to manual and bring on as and when I feel I need it as some days need and some days don’t, the further we get into autumn and much colder weather I will set to auto but try reduce the timed events until the really cold weather when sometimes it can be on all day due to freezing conditions outside. Some people would sooner the convenience of switching to auto now and forgetting about. What ever suits your needs is the only real answer.
      Hope this helps
      Regards
      Roger
      Please Like & Subscribe

  • @emmah7685
    @emmah7685 4 роки тому +1

    our landlord has just installed a new boiler and we have this , this was so helpful thankyou ! subscribed !

    • @theheatingpro
      @theheatingpro  4 роки тому

      Hi Emma, Glad it helped and thanks for Subscribing. Any questions let me know
      Regards
      Roger

  • @poppydoodles8514
    @poppydoodles8514 6 років тому +5

    This video is an absolute godsend. Thank you!

  • @johnburns4017
    @johnburns4017 5 років тому +1

    _Manual_ means it is just a room stat. Using _OFF_ and _MAN_ means it is just a room thermostat with an on and off switch. Very useful and *simple.*

    • @theheatingpro
      @theheatingpro  5 років тому +2

      John Burns Hi John, Thanks for the comment. Truly hope the video helped as that’s what I set out to do as the instructions with most stats are as clear as mud. Useful and simple is praise indeed.
      Regards Roger

    • @johnburns4017
      @johnburns4017 5 років тому

      @@theheatingpro
      Very useful. I get many requests to remove complex stat/programmers, especially by landlords, as people do not understand them. Except for their latest models, Salus and Horstmann are awful to figure out. Terrible products. The landlords are fed up with requests from tenants on how to use them, and of course the landlord does not know.
      The regs say the stats/programmers must be Boiler Plus compliant, so timers are needed. Many people in flats, especially rented flats, do not use the timers, they just want to turn the heating on and off simply when they wake up and go out. And set the temperature simply.
      This range of Boiler Plus compliant stat/timers gives that - a stat with an on-off switch.
      Because of people using the on-off, I advise to install a kickspace heater with a switch over the worktop, in the kitchen, as these warm up the room quickly. So they can get up in mid winter, switch on the heating and get instant heat from a kickspace as they make breakfast. A big hit.

  • @richardparry6696
    @richardparry6696 3 роки тому +1

    this video was so much better than the manual...thank you

    • @theheatingpro
      @theheatingpro  3 роки тому

      Thanks Richard,
      I would like to think so as I gave up on the instructions manuals years ago lol
      UA-cam has been my go to for everthing so only too happy to add my knowledge on all things heating to helps others.
      Let me know if you have any questions as I am only too happy to help
      Regards
      Roger
      @theheatingpro
      Please Like & Subscribe

  • @Coopdegras
    @Coopdegras 3 роки тому +1

    Really helpful video! I turned off the boiler to replace some taps and must have switched to auto was running a programme of different temperatures which I was manually changing, it was driving me mad I just needed to switch it to manual 🤣 just keep at a constant temp. Thank you.

    • @theheatingpro
      @theheatingpro  3 роки тому +1

      HI Bean,
      Glad the video helped you out
      Regards
      Roger
      Please Like & Subscribe

  • @MSB240
    @MSB240 4 роки тому +38

    Instructions to change from 4 to 6 programmes.
    Change From 4 Programs To 6 Programs
    1. Move the slider bar to the OFF position. You should see a snowflake on the display.
    2. Press & Hold the A button, H button and >> button together. You will see either ON or OFF flashing on the display. Release the buttons.
    3. Press & Release the >> button until you see CODE on the display.
    4. Press the >> button once more and you will see an error code appear and then disappear.
    5. The error code will be replaced by number 4.
    6. Use the + button to change the 4 to 6.
    7. Press the HOME button to exit the menu.
    You will now have 6 programmable events instead of 4
    Hope this helps ¡¡

    • @monsterp1970
      @monsterp1970 4 роки тому +1

      MSB MSB Thank you! The instruction manual for this controller is poor. They tell you how to change done thing but don't explain why you might want to do so. 😤

    • @Kingsofgames
      @Kingsofgames 4 роки тому +1

      Literally eatched the whole video to find this. Thank you. Couldnt find this anywhere

    • @fateema7
      @fateema7 4 роки тому +1

      Thank you

    • @poisonedchalice
      @poisonedchalice 3 роки тому +1

      Thank you!

    • @richardstafford4170
      @richardstafford4170 3 роки тому +1

      Thank you

  • @sanjayjoshi4172
    @sanjayjoshi4172 3 роки тому +2

    Thank you for taking the time to make this video. I found this very useful.

    • @theheatingpro
      @theheatingpro  3 роки тому

      Hi Sanjay,
      Thank you for taking the time to leave the comment. You are most welcome
      Regards
      Roger
      @theheatingpro.com
      Please Like & Subscribe

  • @abovemsa4123
    @abovemsa4123 3 роки тому +2

    Very concise and clearly presented. Thank you!

    • @theheatingpro
      @theheatingpro  3 роки тому

      Hi Above Msa,
      Thanks for the comments, any questions just let me know
      Regards
      Roger
      @theheatingpro.com
      Please Like and subscribe

  • @martynstuart1191
    @martynstuart1191 2 роки тому +1

    Nice video with good detailed explanation of controls

  • @dariuszebrauskas4865
    @dariuszebrauskas4865 9 місяців тому +1

    Thanks for this great video. Is there a some secret or advanced settings in this thermostat? The problem i am having is, lets say i turn Manual mode and set the temp to 19 degrees. Now the heating wont kick in until it drops to 18 degrees and wont stop untill it reaches 20! Which is insane and drives me mad. Is there some setting that can be changed? Thank you

    • @theheatingpro
      @theheatingpro  8 місяців тому

      That's exactly as it works. To get an average temp maintained of 19 the stat will drop to 18 heat to 20 the average then the 19 you set. If you drop it to 18 it will swing between 17&19 to get the average temp and so on. Hope this helps

  • @andrewrussell4707
    @andrewrussell4707 3 роки тому +2

    Useful video, thanks.
    I needed read the comments below to understand the switch between 4 event and 6 event set-up.
    Unfortunately, no sign of how to do this basic function change on the ESi website.

    • @theheatingpro
      @theheatingpro  3 роки тому +2

      Hi Andrew,
      It is hidden somewhere in the installer instructions and not in the user iinstrcuctions which is a bit of an oversight for sure. Glad you found it in the comments and I will pop up a short video soon, as I realise this is a repeated comment/question
      Glad you found the answer in the comments but please feel free to ask in future if you have any questions
      Regards
      Roger
      @theheatingpro.com
      Please Like & Subscribe

    • @andrewrussell4707
      @andrewrussell4707 3 роки тому +2

      @@theheatingpro yes I was thinking later that the 4 to 6 issue might be in the installation part of the instructions, but a bit of an oversight it’s not in the operating instructions (IMO)
      Thanks for the reply.

    • @theheatingpro
      @theheatingpro  3 роки тому +1

      @@andrewrussell4707 Truly is as the engineer at setting up will not likely know the customers requirements for event times settings, thats if they set it up at all. Quick google of the installer instructions in pdf may help you
      Regards
      roger
      @theheatingpro.com

  • @tkdonyt
    @tkdonyt Рік тому +1

    1. Thank you Very much.
    2 Question -
    . Only getting 4 Settings.
    Unable to get mid day setting. Goes straight to P1, P2, P3 & P4. I'm not getting P1,2,3,4,5 6 !
    Any idea what I'm doing writing please? Tried on all 3 options of 5/2, 7 day, 24 Hr !!
    Thank you so much again.

  • @debonweb
    @debonweb 4 роки тому +1

    Thanks so much for this. I got this stat with my new boiler last April but have found the instructions that came with it pretty useless so have just been using the manual option to turn heating off and on until now. Not ideal ! I still find it pretty confusing tbh - with all the available options - but after I've watched your vid perhaps 6 more times it may all sink in! :) You're a star for making this vid though .... it's a huge help ...... so thanks again.

    • @theheatingpro
      @theheatingpro  4 роки тому

      Deborah Moores Hi Deborah, glad it helped out,
      Merry Xmas.
      Regards
      Roger
      Please like and Subscribe

  • @Iremnaz786
    @Iremnaz786 Рік тому +4

    Hi Thank you so much for the clear instructions but when I am setting up the programme it only goes upto p4, how can I set times for p5 and 6? Thanks in advance 😊

    • @theheatingpro
      @theheatingpro  Рік тому

      Hi Irem, I will post a video this next week to show you how to do this. Easier than my me giving you a rambling on how to do it
      Regards
      Roger
      @theheatingpro.com
      Please Like & Subscribe

    • @theheatingpro
      @theheatingpro  Рік тому

      Just set this in my reminders to have posted by this Sunday

  • @bonzillesgames
    @bonzillesgames 3 роки тому +1

    Thank you for the information had one of these fitted last week when the old thermostat went wrong but the bloke that fitted it never told me how to actually use it just fitted it as quickly as possible and left as soon as he could.
    tried using the attached manual but could work head nor tails from it way too many settings one I had before just had a couple of buttons temp up temp down way easier to use but I suppose that's progress for you. Working fine now so thanks again.

    • @theheatingpro
      @theheatingpro  3 роки тому

      Hi,
      Glad the video helped you out. Any questions let me know
      Regards
      Roger
      @theheatingpro.com
      Please Like & Subscribe

  • @fionawilliams1081
    @fionawilliams1081 11 місяців тому +1

    Thank you so much for your clear instructions.

    • @theheatingpro
      @theheatingpro  11 місяців тому

      Thanks for the kind words. please Like and Subscribe

  • @rogerturner5504
    @rogerturner5504 Рік тому +1

    A very good presentation - excellent help thanks. A quick question. Owing to the current gas prices, we only want events 1 & 2, on/off in the morning. What is the best way to disable further events during the day? Would be very grateful for a response.

    • @theheatingpro
      @theheatingpro  Рік тому

      Just set all the other events to your off temp, doing so it will ignore them

    • @rogerturner5504
      @rogerturner5504 Рік тому

      @@theheatingpro Thanks Heating Pro - I did manage to figure it out shortly after my query to you. What was not clear at the time was setting the off temp to some quite low value like 10 degrees. Thought it through and now we are fine. Best wishes.

  • @KuldipSingh-wv6ce
    @KuldipSingh-wv6ce 2 роки тому +2

    Flippin brilliant video. So useful.

  • @catsandtoys9701
    @catsandtoys9701 2 роки тому +2

    Hi thanks so much for this. Can you tell me how to just put hot water on but not heating? For in the summer. Thanks. Ellen x

    • @theheatingpro
      @theheatingpro  2 роки тому +1

      Hi,
      Typically you can do this via the boiler and set to hot water only usually a tap symbol if you have a combi boiler. It means regardless of what your heating stat is calling for the boiler will only accept hot water calls

    • @brie36benya12
      @brie36benya12 10 місяців тому

      I have a combi but can't find tap symbol and water isn't hot today

  • @poisonedchalice
    @poisonedchalice 3 роки тому +1

    Thank you so much for this video. Everything was so easily explained. You make a great teacher!

    • @theheatingpro
      @theheatingpro  3 роки тому

      Thanks Rosebud, Kind of you to say
      Regards
      Roger
      Please Like and Subscribe

  • @theheatingpro
    @theheatingpro  2 роки тому +2

    I hope this helps a little for the many posting comments regards the UNBOIL message.
    This is the response from ESI -
    The UNBOIL message which appears in place of the date on your thermostat is an OpenTherm notification. It is telling you that your boiler will not need to heat the return water any further at the moment as it is already satisfied. Typically, thermostats use electrical voltage to talk to boilers to say either ON or OFF, however OpenTherm works by using a language (called OpenTherm) that works as a load compensator which will regulate your heating by modulating the boiler at specific points to keep your heating at your target temperature far more accurately. The UNBOIL message will not interfere with any functions on your room thermostat and it is normal to see this. If your thermostat was not wired in using the OpenTherm terminals, then it is in effect talking to itself, but it will still not have any negative influence on the operation of your thermostat.
    This is the response I have received from ESI regards this and I have asked for further info on how to resolve this (a possible factory reset). I will hopefully update you soon as to their reply, as I dont believe there will be many that are wired opentherm and that it is a glitch for it to happen on a standardly wired stat.
    Most modern boilers will have the ability to be wired OpenTherm but will very likely be wired to the standard switched live.
    Regards
    Roger
    @theheatingpro.com
    Please Like & Subscribe

    • @qamarzaman6013
      @qamarzaman6013 2 роки тому +1

      Thank you. I was having heart failure because I don't have money to have mine repaired. It gives me reassurance that it will not interfere with the boilers normal operation.

    • @nickdavis531
      @nickdavis531 Рік тому +1

      Really glad I found you're video! Our thermostat is doing the same... Unbol. Glad it's nothing to worry about. Thanks for your informative video.

  • @fma7483
    @fma7483 Рік тому

    You sir are a lifesaver! Thank you very much. More informative than any manual!!👍👍

    • @theheatingpro
      @theheatingpro  Рік тому +1

      Hi FM A,
      I am the opposite to a manual, just genuine how do i work this, and this is how it works.They don't seem to be able to do this in any manual
      Regards
      Roger
      @theheatingpro.com
      Please Like & Subscribe

  • @mattpryor2762
    @mattpryor2762 3 роки тому +3

    Thank you, very helpful. I'm still trying to figure out what those two red and green buttons on the receiver unit are supposed to do though.

    • @KK-mg7nb
      @KK-mg7nb 2 роки тому +1

      That's what I'm struggling with

  • @annamaynard9498
    @annamaynard9498 3 роки тому +1

    Thanks very helpful 70years old didn't have to ask the kids 😊

    • @theheatingpro
      @theheatingpro  3 роки тому

      Hi Anna,
      Glad to be of help and save asking the kids!!
      Regards
      Roger
      @theheatingpro.com
      Please Like & Subscribe

  • @johnsmithysmith1930
    @johnsmithysmith1930 2 роки тому +1

    FABTASTIC VIDEO! Love it. Thank you. I can’t see the follow up videos on the other features of this (as you said you would do in the video). If you could do them that would be great. But brilliant nonetheless. Thank you

  • @onnoderooij4893
    @onnoderooij4893 Рік тому +1

    Thank you for this instructive video - your ESRT4RF+ shows P1 to P6 ours has just P1 to P4. The use instruction states on page 9 the Optimum Start [and stop] whereby the thermostat optimizes when to start to reach a pre programmed temp. at a given time. Could you demonstrate how that can be "activated" or set ?

    • @theheatingpro
      @theheatingpro  Рік тому

      I have a list of videos to do from peoples comments so i will add this and get it done as soon as I can. Hit the Bell symbol on my channel and it will notify you when I load up a video. i will get this up as quick as I can

  • @JulieBlackwell-West
    @JulieBlackwell-West 8 місяців тому +1

    Hello. We have just had this installed. We want our heating to come on 7 days a week at 6am at 21 degrees and go off at 10.30pm at 17 degrees. I believe your video said I have to select the 24 hour option to make it the same each day? Our installer said we would need to select 7 days if we wanted it the same for 7 days which is different to your advice. I’m not sure what to do with P3 & P4 and P5 & P6 as we only need the 2 temperatures. Are you able to advise please?

    • @theheatingpro
      @theheatingpro  8 місяців тому

      Hi,
      Not quite, 7 days setting gives you the ability to set each day individually for those with non standard work patterns. ie work from home on a Thursday you can set that day up differently.
      Ok so you have 6 settings. Set up 1 at 6am for 21 degrees, 2,3,4&5 at any time between 6am and 10:30pm all at 21 degrees then set up 6 at 10:30 pm at 15 degrees. That way is will see as you have a demand all day at 21 degrees and ulimately only adjust the temp down at 10:30pm as you want.
      Hope this helps
      Regards
      Roger@theheatingpro.com

  • @CA-gm1bu
    @CA-gm1bu 3 роки тому

    Thank you for doing this. The instruction manual was hard to understand and this is great!

    • @theheatingpro
      @theheatingpro  2 роки тому

      C A,
      You're welcome!
      Regards
      Roger
      @theheatingpro
      Please Like & Subscribe

  • @pdr60
    @pdr60 Рік тому +1

    Do you have to use all 6 settings (P1 P2 etc) or can you just use 2 or 3 ? Thanks

    • @theheatingpro
      @theheatingpro  Рік тому

      Hello,
      You can use as many as you like, if yo dont want a setting just choose the same temp as the previous off temp it will then ignore the chagne of temp. So P1 0630 20 degrees - P2 0830 15 Degrees - P3 1630 20 degrees - P4 2200 15 degrees. Then P5 2215 15 degrees, P6 2230 15 degrees. If set along these lines as you can see iit will ignore the last two as the temp doesnt change from P4.
      If you wanted heating on more perm then set P1,P2,P3,P4,P5 to 20 degrees and P6 to 15 degrees and it will give you heat all da.
      Hope this makes it clearer
      Regards
      Roger
      @theheatingpro.com
      PLease Like & Subscribe

  • @olfamejdi
    @olfamejdi 2 роки тому +1

    Thank you for this video very helpful explanation 👍🏾

  • @alayneamitchinson4034
    @alayneamitchinson4034 3 роки тому +4

    How do i just knock the heating on and off when i want?

  • @asmrbeautyreviews
    @asmrbeautyreviews 5 місяців тому +1

    Does this operate hot tap water . Can you distinguish setting for heating and hot water barrel for the tap? Or is this only for room temperatures.

    • @theheatingpro
      @theheatingpro  3 місяці тому

      Only the heating. If you are a combi boiler hot water is as you turn on the tap. if you have a cylinder then you will have another control for the hot water

  • @rassellsobur5342
    @rassellsobur5342 2 роки тому +1

    Is there a certain temperature or what is the best and most efficient temperature I need to set my boilers hot water and radiators to?? At the moment I have both my water and heating temperature up to the max is that a good idea?? Thanks again for taking the time making this very helpful vid

    • @theheatingpro
      @theheatingpro  2 роки тому +3

      Hi Rassell,
      Hot water - set to temp you want to come out of the tap and no more
      Most boilers will output around 65 degrees which is more than you would typically want. The lower you are happy with the setting the cheaper on gas. No point heating hot water to a temp too high then mixing in cold to cool it down, you paying for the privilege.
      Heating - Some boilers have a E setting on them which is usually the best place to set without me seeing it first hand. A lower temp is ok as long as it meets your demand and ultimately gets the house up to temp. Reduce it slightly and take a look at your desired temp at the stat. Try reducing it by 0.5 degrees at a time over the period of a couple of weeks. This way you do not notice a slight reduction in temperature and become acclimatised. Again over a longer period will improve you effiency and save on those gas bills.
      Hope this helps and feel free to ask any other questions
      Regards
      Roger
      @theheatingpro
      Please Like & Subscribe

  • @Phil8719
    @Phil8719 3 роки тому +2

    Great video, but how do you set up optimum/delayed start or does the ESRTP4 not support these?

    • @theheatingpro
      @theheatingpro  3 роки тому +2

      Hi Phil,
      Sorry for the late response been a busy weekend.
      The stat does indeed give you the ability of TPI/Delayed/Optimum Start. It also has an Optimum Stop feature. Based on your question I will do a further video to show how this is done but to help out here and now please see the comments below
      Regards
      Roger
      @theheatingpro.com
      Please Like and subscribe

    • @Phil8719
      @Phil8719 3 роки тому +1

      @@theheatingpro thanks that would be great 👍

    • @theheatingpro
      @theheatingpro  3 роки тому +2

      Delayed Start - can delay the heating coming on by up to 45 minutes depending on how warm the room is when the heating is due to come on
      1. Switch slider to off, press and hold both A and H buttons, then press the next>> button to enter the tech settings. Then release all buttons. Use the +&- buttons to choose between OFF (running to normal settings) DS (delayed start delay of up to 45 mins based on room temp) when ON it will run this. OS (optimum start) when ON is selected it will run in this. You then have the option of pressing the >> button for OP STOP (on/off) and pressing>> again TPI settings with choices of OFF ( normal swing value) 3 or 6 cycles (3 is for oil fired boiler 6 for gas). Pressing>> again gives you swing sensitivity calibration.
      I will try and get a video on in the next few weeks covering this for you. TPI may not be available depending on how you system/ boiler is wired and what it is capable of. While the instructions do not have clarity on this it would usually require opentherm capabilities and wiring.
      Hope this helps & please come back to me with any questions
      Regards
      Roger
      @theheatingpro.com
      Please Like and subscribe

    • @theheatingpro
      @theheatingpro  3 роки тому +1

      @@Phil8719 Hi Phil, Only too happy to make extra videos based on your requests/questions. Not too many asking the questions you have, you have a better understanding than most. Not too sure how most people would take the video ( think I would loose 99.9%) but I am thrilled to do so.
      Thanks for your questions makes me very happy to extend the learning more than the general enquiries.
      Regards
      Roger

  • @saralfc6
    @saralfc6 3 роки тому +2

    Brilliant video. You exactly everything so well thank you

    • @theheatingpro
      @theheatingpro  3 роки тому

      Glad it helped, any questions please ask
      Regards
      Roger
      @theheatingpro.com
      Please like and subscribe

  • @amnaali9835
    @amnaali9835 Рік тому +1

    Hi, thank you for the video. Do you know how to turn the light on. My machine has gone dark and I don’t know how to turn the light on

    • @theheatingpro
      @theheatingpro  Рік тому

      Hi Amna,
      Sounds like you may be in need of a battery change.
      4.3 Battery Replacement
      When the low battery symbol flashes in the LCD display, the
      batteries need to be replaced as soon as possible. The battery
      compartment is located on the front of the thermostat, under
      the fascia cover. Remove the old batteries and insert new
      ones. All settings including time are maintained.
      N.B. If the display ever goes blank during normal operation,
      the batteries need to be replaced with high quality
      alkaline cells. The date, time and factory pre-set heating
      times will be retained (assuming the back up battery has
      not failed).
      Hope this helps
      Regards
      Roger
      @theheatingpro.com
      Please Like & Subscribe

    • @amnaali9835
      @amnaali9835 Рік тому

      @@theheatingpro thank you for responding! But the battery sign isn’t flashing. It shows half full though

    • @theheatingpro
      @theheatingpro  Рік тому +1

      @@amnaali9835 Try the batteries sometimes they deplete before the battery warning comes up

    • @theheatingpro
      @theheatingpro  Рік тому

      @@amnaali9835 first place to start

    • @amnaali9835
      @amnaali9835 Рік тому +1

      @@theheatingpro thank you!

  • @RachaelHarney
    @RachaelHarney 8 місяців тому

    Hi Roger. Just had this thermostat fitted. Did you do the other videos as I’m trying to work out how to set the delayed start and optimum start. Any help would be greatly appreciated. Thanks Rachael

  • @jessicahopton9849
    @jessicahopton9849 4 роки тому +2

    Thank you so much much easier than instructions! My downstairs thermostat says room temperature is constantly at 25 degrees which means I can’t use the auto mode other wise the house will be boiling! Is there a way to reset room temperature other than battery change and holding reset button?

    • @theheatingpro
      @theheatingpro  4 роки тому

      Hi Jessica, Sorry I missed your comment, a few comments don't seem to have been appearing in my feed and I have only just seen it now. If the display is showing the actual room temp at 25 degrees and your set temp is less than this your heating shouldn't some on anyway. your heating should only ever kick in if your room temp is lower than your target temp. One thing I wiould check is your upstairs stat isn't contolling downstairs. Turn down downstairs stat and turn up upstairs, if downstairs stays cold your ok, if they come on you have crossed zones which would need rectifiying.
      I could maybe talk you through how if this were the case
      Regards
      Roger
      Please Like & Subscribe

  • @jax8009
    @jax8009 3 роки тому +1

    Thank you, I now understand my new boiler remote control much better, the instructions that came with it are not clear at all. I also know why the heating didn't go off!

    • @theheatingpro
      @theheatingpro  3 роки тому

      Glad it helped Jacky.
      Regards
      Roger
      @theheatingpro.com
      Please Like & Subscribe

  • @janebuffoni3549
    @janebuffoni3549 2 роки тому +1

    Just moved house couldn’t work the timer out! Was the A button! Thanks so much I really understand how to use it now

    • @theheatingpro
      @theheatingpro  2 роки тому

      So Glad it was helpful Jane. Any questions just let me know.
      Regards
      Roger
      @theheatingpro.com
      Please Like & Subscribe

  • @nobro6824
    @nobro6824 2 роки тому +1

    Amazing video. Exactly what I was looking for

  • @PopcornPlaya8589
    @PopcornPlaya8589 2 роки тому +1

    Thanks for the video mate. Just had it installed and I'd got it on manual for now so what should I have the receiver on m/a or just manual? Iv got it on m/a at min and it makes a clicking noise every 10secs.

    • @diw885
      @diw885 Рік тому

      Id like to know the answer to that question aswell. If wanting to set on automatic mode, should the receiver be switched to M or M/A?

    • @PopcornPlaya8589
      @PopcornPlaya8589 Рік тому

      @Di W iv no answer for you unfortunately still clicks all the time!

  • @xxdoodlemegxx3174
    @xxdoodlemegxx3174 3 роки тому +1

    Thankyou for this! What does the H button mean as well please? Thanks.

    • @theheatingpro
      @theheatingpro  3 роки тому

      Hello,
      You are Welcome.
      The H button is a holiday mode button.
      Holiday Mode saves energy by letting you reduce the
      temperature for 1 to 99 days while you are away from
      home, resuming normal operation on your return.
      You will need to set up the amount of days you will be away and what you would want the temp set to while you are away. After the days have counted down to zero it will return to your normal program.
      Hope this helps
      Regards
      Roger
      @theheatingpro.com
      Please Like & Subscribe

  • @iaanken347
    @iaanken347 3 роки тому +2

    Hi Thank you for the video and let us know “how to use” remote thermostat. Could you please advise what to do with other part of the thermostat which is fixed next to the boiler. Which has two buttons (M/A = RED & Manual = GREEN). Not sure when I need to leave them (both or only one) on for what setting?

    • @iaanken347
      @iaanken347 3 роки тому +1

      Sorry, just to update. I moved into a new property and found this heating system. I’m not sure how to set for any specific heating...
      Regards

    • @theheatingpro
      @theheatingpro  3 роки тому +1

      Hi Iaan Ken,
      the stat you have must be the RF version of this one with a receiver at the boiler to communicate without wires between the stat and boiler. Esi themselves have a couple of videos on this as I don't have an RF version to do a video on to show you. ua-cam.com/video/W24dLq4K3Gc/v-deo.html&feature=emb_logo
      Hope this helps but sounds like you may have manually overridden it if both lights are on so check this one out too.
      ua-cam.com/video/4H9VkBUfsHs/v-deo.html&feature=emb_logo
      Hope this helps
      Regards
      Roger
      @theheataingpro.com
      Please Like & Subscribe

    • @iaanken347
      @iaanken347 3 роки тому +1

      @@theheatingpro Thank you very much. I’ve sorted and set my heating system. Thank you for your help and support. Cheers

  • @rebeccataylor7642
    @rebeccataylor7642 3 роки тому +4

    We just got this today and we have 4 available programmable times. How do you get it to be 6 available times as you have?

    • @dupalopez
      @dupalopez 2 роки тому

      I know it's been 9 months since you asked the question... I've only just had this boiler installed and found the answer here:
      ua-cam.com/video/0g1EQp-UOcA/v-deo.html

  • @Danzwain1
    @Danzwain1 3 роки тому +1

    Excellent work help me out greatly

    • @theheatingpro
      @theheatingpro  3 роки тому

      Thanks Daniel
      Appreciate you saying. Any questions just post in comments
      Regards
      Roger
      @theheatingpro.com
      Please Like & Subscribe

  • @juliesettle3443
    @juliesettle3443 8 місяців тому +1

    Thank you - very well explained

  • @jamesshall5160
    @jamesshall5160 5 років тому +1

    Thanks for this great video. Just one question please. On your boiler, mine is Baxi 600. Do you turn the boiler on to maximum all the time to activate these settings on the thermostat?

    • @theheatingpro
      @theheatingpro  5 років тому

      james shallow Hi James, Boiler on max generally gives you an output on most boilers of between 75-80 degrees. This in theory shortens the time for your house/apartment to heat up and will likely result in your boiler reaching modulation/condensing mode quicker so again in theory should be cheaper on the gas bill. This will cover most modern installations 10 years old and less. Hope this helps Regards Roger

  • @emmadawson2360
    @emmadawson2360 8 місяців тому

    I have the thermostat, which I'm using manually. Can I switch off the heating, even if the room temperature doesn't reach the set temp - say after an hour? Can I switch the heating off once the set temperature has been set, but the swing setting hasn't kicked in, ( +/- 0.5 degrees c) - the set temperature and house temperature are the same, but the house temp hasn't reached 18.5 degrees?

  • @SS-kp7hw
    @SS-kp7hw 3 роки тому +1

    Life saver for the pre dawn populace

    • @theheatingpro
      @theheatingpro  3 роки тому

      Thanks S S,
      My exact target audience.
      Regards
      Roger
      @theheatingpro.com
      Please Like & Subscribe

  • @anneford2700
    @anneford2700 Рік тому +1

    Thank you so much, now I understand it !!

    • @theheatingpro
      @theheatingpro  11 місяців тому

      Glad it helped! Please Like and Subscribe

  • @Abbeyhartwig123
    @Abbeyhartwig123 3 роки тому

    Hi, really helpful and I have subscribed. I am still a little confused. All I want to do is it be around 21 degrees from 6.45 am to 7.45 am and then off until I get home from work at 5pm, around 21 degrees again. Don’t want heating on while I’m at work. Xx

  • @MegaStuart22
    @MegaStuart22 3 роки тому +1

    Just had mine setup, watched your vid but where the date shows at the bottom it flashes " unboil " any ideas why ? Tks

  • @futurecarslondon1109
    @futurecarslondon1109 5 років тому +1

    Very grateful for the demo.

  • @Sara-qe3fw
    @Sara-qe3fw Рік тому

    Roger. Can you tell me please. When the heating comes on, should there be a flame symbol on the thermostat? I don’t ever remember seeing one. Thanks.

  • @sarahguppy6580
    @sarahguppy6580 5 років тому +1

    thank you, great instructions, made setting our boiler so much easier

    • @theheatingpro
      @theheatingpro  4 роки тому

      Thanks for the comments Sarah
      Regards
      Roger
      Please Like & Subscribe

  • @leonperry123
    @leonperry123 2 роки тому +1

    hello. cant find the other video with the DS/OS setting? thx for this film as i know know P2 is off ect.

    • @theheatingpro
      @theheatingpro  2 роки тому

      Thanks Leon, I will uplaod the video regards the DS/OS, glad you know the P2 now lol

  • @MegaBrandonion6
    @MegaBrandonion6 3 роки тому +1

    Hi I hv this thermostat could you tell me what un bol 1 means it keeps flashing up where the date and time shows at the bottom ...never noticed it do it before.i hv it on manual ..thnk u

  • @alangreensmith7887
    @alangreensmith7887 Рік тому +1

    Know about the frost protector setting but I have another control box next to the boiler, not sure what I do with it, it has 2 buttons, 1 manual 1, M,A , esi model.

    • @theheatingpro
      @theheatingpro  Рік тому +1

      Hi Alan,
      You must have an RF set up. This means your stat does not have wires back to the boiler, but the stat communicates with the receiver ( control box at the boiler) via radio frequency (RF). The stat and receiver need to be connected and there are ways to set this up. You can always override the stat which is the manual on the control box.
      Look through the details below and hopefully you will be able to pair the two and be able to use the stat as you would like.
      Manual Operation
      It is possible to operate the receiver manually. This may be
      necessary where, for example, the batteries in the Thermostat
      (Transmitter) are depleted and therefore the heating cannot
      turn ON or OFF.
      1. To engage the manual override, press the MANUAL
      button on the receiver, which will then light up with a
      18 19
      green background. This shows that the manual override
      is active.
      2. Use the M/A button to manually override the status of
      the receiver. If ON, the heating will turn OFF (M/A red
      light goes off). If OFF, the heating will turn ON (M/A red
      light comes on).
      N.B. It is important to remember that the automatic control
      of the receiver is now off and the receiver will only
      respond to manual operations.
      3. To return to Auto mode, press the MANUAL button on
      the receiver and the green light will turn off. The receiver
      should now be back in Auto mode, recieving commands
      from the thermostat.
      N.B. If the receiver cannot receive a signal for 30 minutes,
      both the red and green light will flash and the unit will
      need to be reconfigured.
      Hope this helps
      Regards
      Roger
      @theheatingpro.com
      Please Like & Subscribe

    • @alangreensmith7887
      @alangreensmith7887 Рік тому

      Wasn't sure if frost protector was kicking in when temperature drops but heard boiler start up., thought maybe it should light up on receiver.

  • @sabine7864
    @sabine7864 2 роки тому +1

    Hi there
    I have this thermostat, I have a filter symbol coming up and the heating isn't coming in.
    Can you please advise as to whether this is linked and how to get it back to normal?
    Thank you
    Regards

    • @sabine7864
      @sabine7864 2 роки тому

      I have found the solution from another video.
      Might be useful for everyone else.
      ua-cam.com/video/4H9VkBUfsHs/v-deo.html
      I switched my boiler off as my local water pipe burst and we had no water in the house so was advised to switch off boiler. When I switched it on, heating wasn't coming on via thermostat and a "filter" sign was showing which I didn't know what it meant. I had to switch heating on manually from the boiler which was a pain. The above link was useful and helped me reset it.
      Hope it helps

    • @theheatingpro
      @theheatingpro  2 роки тому

      Hi Sabine, Glad you found the answer on ESi's own videos. This video is for the standard stat whereas the issue you have is on an RF version. I have never fitted the RF version as all the ones we work with on New Build are hard wired. The basis for setting up is the same but just the pairing and manual override on the RF unit.
      Regards
      Roger
      @theheatingpro

  • @TheEntourageOnline
    @TheEntourageOnline 3 роки тому +2

    Mate that's bang on.
    Thank you 🙏🏾

  • @chrislangwade4245
    @chrislangwade4245 5 років тому +1

    Hello,
    first things first,this is a cracking video, very informative..(maybe ESI should link to this guide, it's a million times more informative than the instructions that come in the box..)..
    my question is this, after setting my stat to the times and temps i want do i leave the slide button in 'prog' or switch it across to 'Auto' to let it run as i've programmed..?
    many thanks in advance.

    • @theheatingpro
      @theheatingpro  5 років тому +1

      Chris Langwade Hi Chris, switching to auto runs those times and temps you have set up. Prog is just that where you set those programs. Thanks for the kind feedback Regards Roger

  • @Umar-sheraz
    @Umar-sheraz 3 роки тому +1

    Thank you saved me time

    • @theheatingpro
      @theheatingpro  3 роки тому

      Happy to help
      Regards
      Roger
      @theheatingpro.com
      Please Like & Subscribe