840D siemens pcu 20 NCK and PLC reset procedure and backup reload

Поділитися
Вставка
  • Опубліковано 12 вер 2024
  • This video contains procedure of NCK and PLC reset with backup upload for 840D siemens cnc system (PCU 20). No laptop is required to complete it

КОМЕНТАРІ • 21

  • @massabnajm
    @massabnajm 6 місяців тому

    How can i get backup to remove falsh light and alarms please help me

  • @dillongreen1045
    @dillongreen1045 Рік тому

    Do you know where the battery for the memory is? We are about to move ours and do not want to loose the parameters

  • @seimela
    @seimela Рік тому

    What kind of protocol does this motors use

  • @ankitprajapati726
    @ankitprajapati726 Рік тому

    Sir Vmc 1050 seimans 810d mai agar backup save hai machine Mai to wo kay say dale wapas say

  • @prakasams4945
    @prakasams4945 Рік тому

    Hi sir, same machine we have. We upload the backup through NC CARD. After loading the backup we done reference settings. How to copy part program from PC card. PC card shows only in Services pages not in program manager .

    • @letslearn4funn
      @letslearn4funn  Рік тому

      I will try to upload a video for that on Monday.

    • @letslearn4funn
      @letslearn4funn  Рік тому

      In Data OUT option it will show you option of pc card

  • @sheelkumarm
    @sheelkumarm 7 місяців тому

    Adapter setting kaise set kare bataiye. Mera HMI tool waiting for connection dikha Raha hai

  • @thiruppathia1480
    @thiruppathia1480 Рік тому

    Thanks for your video, kindly make more videos, can i get procedure for pdf file.

  • @AshokPanchal-vd4dn
    @AshokPanchal-vd4dn Рік тому

    aap full pixel ke sath video upload kijiye abhi full screen krne pr video ktti hui dikh rahi he

  • @tranguyenvan8580
    @tranguyenvan8580 Рік тому

    Hello, Can you help me fix error 2120 "NCK fan alarm type %1", thanks you!

    • @letslearn4funn
      @letslearn4funn  Рік тому

      Check fans below NCU unit. There are also fan with NCU battery. If battery is to be removed take NC/PLC backup first

  • @bagora4
    @bagora4 Рік тому

    An you help me please with 14510 error missing proc

    • @letslearn4funn
      @letslearn4funn  Рік тому

      Mention your system model e.g. 840D Or something else? Does error occur during Program cycle run?

    • @bagora4
      @bagora4 Рік тому

      @letslearn4funn yes it occurs when you hit start cycle

    • @bagora4
      @bagora4 Рік тому

      @@letslearn4funn model 840d powerline

  • @Harshkumar-xt5ks
    @Harshkumar-xt5ks Рік тому

    NC PLC connectionwating problem

  • @krishnapachauri3930
    @krishnapachauri3930 5 місяців тому

    Hello Sir, Can I get your contact number. We are facing the same issue and not able to resolve.

  • @yuvrajgvlog1986
    @yuvrajgvlog1986 Рік тому

    Sir make new video

  • @ankitprajapati726
    @ankitprajapati726 Рік тому

    Sir Vmc 1050 seimans 810d mai agar backup save hai machine Mai to wo kay say dale wapas say