[YANMAR] Alarms and Trips Testing of Auxiliary Engine | Marine Engineering | Technical Vlog : 096

Поділитися
Вставка
  • Опубліковано 24 лис 2024

КОМЕНТАРІ • 40

  • @MrZorro132
    @MrZorro132 2 місяці тому +1

    bro, your videos help me alot for an inspector like me!! Keep uploading and waiting for more videos.

  • @ashishmishra2144
    @ashishmishra2144 9 місяців тому +2

    As always, thanks for all efforts 🙌👌

    • @CHiEF_MOEMYiNTSHEiN
      @CHiEF_MOEMYiNTSHEiN  9 місяців тому +2

      My pleasure !
      Please share to your marine engineers friends.
      Thanks.

    • @ashishmishra2144
      @ashishmishra2144 9 місяців тому +2

      @@CHiEF_MOEMYiNTSHEiN Sure sir, will do the same. This is really a nice channel for a practical insight which is not given in book. Will definitely share. One suggestion from my side- If you keep interacting with people by coming yourself in camera, it will create much more impact and will increase more subscribers. much love from india

  • @SarLay-q3w
    @SarLay-q3w 9 місяців тому +1

    Thank you Sir
    for sharing knownledge

  • @zbihgtv9864
    @zbihgtv9864 5 місяців тому +1

    Next boiler sir. Thank you for your video.

  • @AnatPlk
    @AnatPlk 6 місяців тому

    Thanks a lot ! Great job!

  • @Schadlamow
    @Schadlamow 2 місяці тому +1

    One more may be reverse power trip, just by adjusting governor to that.

    • @CHiEF_MOEMYiNTSHEiN
      @CHiEF_MOEMYiNTSHEiN  2 місяці тому

      Sure.
      Reduces under 0kW by governor adjusting.
      Trip is short time trip and normally occurs 10 seconds.

  • @thihakyawswar2274
    @thihakyawswar2274 8 місяців тому +1

    thanks brother

  • @AshiqHussain-lo1ph
    @AshiqHussain-lo1ph 9 місяців тому +1

    Did all alaram tested while running the generator ?

    • @CHiEF_MOEMYiNTSHEiN
      @CHiEF_MOEMYiNTSHEiN  9 місяців тому +1

      Except F.O Leakage and Manual Emergency Stop.
      (Prefer Man. Emergency Stop to be tested while engine is running.)

  • @rupanjansaha4788
    @rupanjansaha4788 9 місяців тому

    VERY NICE ..

  • @ashishmishra2144
    @ashishmishra2144 9 місяців тому

    Hey sir, What is the suction and discharge pressure that we usually maintain in sewage vacuum pump for 30 people STP ?

    • @CHiEF_MOEMYiNTSHEiN
      @CHiEF_MOEMYiNTSHEiN  9 місяців тому +1

      Did you mean vacuum setting for Vacuummarator in Vacuum Toilet System?
      Clarify.

    • @ashishmishra2144
      @ashishmishra2144 9 місяців тому

      @@CHiEF_MOEMYiNTSHEiN Sir, suction pressure, I got , cut-in we do: - 0.4 bar vacuum and Cut out we do: -0.55 bar vacuum for pressure switch.
      But what is the discharge pressure of sewage vacuum p/p to STP that we usually maintain?

    • @CHiEF_MOEMYiNTSHEiN
      @CHiEF_MOEMYiNTSHEiN  9 місяців тому +1

      @ashishmishra2144
      One side of the pump is vacuum (negative pressure) and other side of pump is positive pressure. 😊

    • @ashishmishra2144
      @ashishmishra2144 9 місяців тому

      @@CHiEF_MOEMYiNTSHEiN yes sir, I understood, but what positive valve we usually maintain !!

    • @CHiEF_MOEMYiNTSHEiN
      @CHiEF_MOEMYiNTSHEiN  9 місяців тому +1

      @ashishmishra2144
      Discharge Pressure of Vacuumarator Pump to STP (or) other points is maximum 0.3 Bar.
      Depends upon capacity (m3/hr) of Pump, discharge pressure (back pressure) can differ, slightly.

  • @ashishmishra2144
    @ashishmishra2144 9 місяців тому +1

    Hey Sir, what is suction pressure and discharge pressure of aeration blower that we maintain in STP ?

    • @CHiEF_MOEMYiNTSHEiN
      @CHiEF_MOEMYiNTSHEiN  9 місяців тому +1

      I didn’t see any suction pressure gauges for aeration blower.
      Depends upon Model of Plant, discharge pressure varies.
      In general, between 0.015MPa and 0.02MPa.
      For 15 to 25 persons, it is around 0.015MPa. For 40 to 65 persons, around 0.02MPa.

    • @ashishmishra2144
      @ashishmishra2144 9 місяців тому +1

      @@CHiEF_MOEMYiNTSHEiN Sir since it is sucking engine room air. so its suction pressure should be 1 bar, is ths correct ? and thus discharge pressure should be more than 1 bar , but as you said discharge pressure is 0.015-0.02 Mpa which is less than 1 bar.. This thing i do not understood

    • @CHiEF_MOEMYiNTSHEiN
      @CHiEF_MOEMYiNTSHEiN  9 місяців тому +1

      @ashishmishra2144
      That’s right ! It take suction from Engine room.
      Not much pressure is required for aeration of bacteria. If air pressure is higher, overflow can occurs and also fault high water level alarm can activate. If air pressure is high, force acting on each side of plant is high. (Ref. Pressure = Force / Area.)
      Safety valve is fitted and set at 0.025MPa for Discharge 0.02MPa blower.
      Pressure drops because of passing suction filter with silencer and design of impellers that are used in blower.

    • @ashishmishra2144
      @ashishmishra2144 9 місяців тому +1

      @@CHiEF_MOEMYiNTSHEiN Okk sir, i got. Sir as suction pressure gauge is not fitted but whenever aeration blower is taking suction of engine room air, then at the time of suction- is this thing sure that suction pressure will be in negative value ?

    • @CHiEF_MOEMYiNTSHEiN
      @CHiEF_MOEMYiNTSHEiN  9 місяців тому +1

      @ashishmishra2144
      Correct !!!
      Suction is negative pressure.
      That’s why you palm gets sucking from silencer when you touch.