LELIT Bianca PL162T: Rotary pump pressure adjustment

Поділитися
Вставка
  • Опубліковано 19 січ 2025

КОМЕНТАРІ • 73

  • @evelynsmith163
    @evelynsmith163 2 роки тому +5

    As ever from the team at Lelit, a simple, clear and easy to understand video. Our Bianca is used professionally by us serving hundreds of espressos a day and is a delight to use. Keep up the good work. Kind regards Paul from France

    • @LELIT_Official
      @LELIT_Official  2 роки тому

      Happy to read this! Have a nice day, LELIT Team

  • @possesionwalton6547
    @possesionwalton6547 6 років тому +18

    Only Coffee Technician will know how impressing this design is

  • @mahlonrhoades4509
    @mahlonrhoades4509 10 місяців тому

    Couldn't have been any clearer or simpler. The shop I bought the machine from set it to 8.5 bar. Using the info here I set it back to 10 bar and will adjust using the paddle if I want to decrease it. Many thanks!

  • @pederkimlunding3352
    @pederkimlunding3352 4 роки тому +3

    Hi. Just bought the Bianca. Comming from Giotto and VBM Super PID DB. This is a fantastic machine. Thank you very much. Please keep up with your instructive vids. It's really giving the users knowledge on the machine. Especially on paddle control🙏

    • @LELIT_Official
      @LELIT_Official  4 роки тому +2

      We are glad you like your new Bianca! Thank you very much! LELIT Team

  • @andersberner
    @andersberner 3 роки тому +3

    Easy to understand ... lovely machine btw! Bougth it six month ago - and I still love it.

    • @LELIT_Official
      @LELIT_Official  3 роки тому +2

      We are happy to read this! Enjoy your LELIT coffee machine :) Have a nice day, LELIT Team

  • @lupingen
    @lupingen 5 днів тому +1

    I adjusted the pump pressure as explained in the video to 9 bar, but during the extraction the group head pressure gauge reaches slightly beyond 10 bar! Why? Should I reduce pump pressure further (to 8 bar maybe) to achieve 9 bar pressure at group head ?

    • @LELIT_Official
      @LELIT_Official  5 днів тому

      Hello, thank you for your comment! We inform you that LELIT coffee machines can reach from 9 to 10.5 bars during extractions. If you want to know more about our machines or you have any question, please don't hesitate to contact us at care.foryou@lelit.com!

  • @ct-t69
    @ct-t69 6 років тому +3

    Is the adjustment (to 10 bar) for the coffee extraction? I mean should this be a positive changement? Thx for the upload

  • @Mido-qr6bw
    @Mido-qr6bw 18 днів тому +1

    Hi, my pump pressure is at 9 bar and group pressure is at 10 bar (with blind filter). Should I reduce pump filter further (to 8 bar maybe) to achieve 9 bar pressure at group head ? Does this have any negative effect on the machine ? Please advise, thank you !!!

    • @LELIT_Official
      @LELIT_Official  17 днів тому

      Hello, thank you for your comment! We inform you that LELIT coffee machines may correctly reach from 9 to 10.5 bars. If you need any more support, please don't hesitate contacting us at care.foryou@lelit.com. Regards, LELIT Team :)

  • @k42p3r
    @k42p3r 3 роки тому +2

    Hi. At 0:29 you say that you will need to calibrate the expansion valve and turn the adjustable screw on the rotary pump. Is it correct that it will need some kind of calibration before lowering the pump pressure by turning the screw anti-clockwise? I have a Bianca v2 if that matters. Best regards, Kasper.

    • @LELIT_Official
      @LELIT_Official  3 роки тому +5

      Hi, we usually regulate di opv to adjust the extraction pressure in the machines with vibrating pump. In the machines with rotative pump, such as Bianca, we do not regulate the opv. This is because the regulation happens already in the bypass of the machine, as shown in the video. Thank you, LELIT Team

    • @k42p3r
      @k42p3r 3 роки тому +1

      @@LELIT_Official Thank you for answering my question. One last thing: will it be ok to lower the pump pressure to 9 bar? The flow rate in my Bianca’s group head is in the low end (320g/minute ) and I am able to pull a double shot (18g in/ 36g out) in 24-25 sec. A finer grind will increase the brew pressure which I’m not interested in.
      I think lowering the pump pressure from 10 to 9 bar will be more optimal, but I want to make sure that the pump pressure is not going to be too low for the machine to operate.
      Thanks! :-)

    • @LELIT_Official
      @LELIT_Official  3 роки тому +1

      @@k42p3r Hi Kasper F, the machine works well also at 9 bars. Speaking about the flow you can increase it, if you need it. Please check the video ua-cam.com/video/rdq9j3AZ6W0/v-deo.html
      Thank you! LELIT team

  • @michaelweku2731
    @michaelweku2731 3 роки тому +3

    If i would like to brew at 9bar, what pressure should i set the rotary pump to?

    • @LELIT_Official
      @LELIT_Official  3 роки тому +5

      It depends on the kind of coffee and on the grind size. We suggest you to adjust the rotary pump over the extraction pressure value. In this case proceed with 9.5 bar. Use the machine with this set for a few days and eventually improve the set up if needed. Thank you, LELIT Team

  • @Aalmal1_
    @Aalmal1_ Місяць тому

    Whats the difference between the pump gauge on the bottom and the one state bar on the grouphead ?

    • @LELIT_Official
      @LELIT_Official  Місяць тому

      Hello, thank you for your comment and for your interest in LELIT coffee machines! To learn more about our products, please contact us at care.foryou@lelit.com!

  • @PanzerIV88
    @PanzerIV88 2 роки тому +1

    The V3 we just received today seems to be factory calibrated at 10 or 10.5Bar which is surprising considering the universal standard for espresso appears to be 9.0Bar everywhere I read. I'll try to adjust it down so it has less pressure, and then re-calibrate my grinder's setting. So far extremely impressed mostly for the price, it is definitely BETTER than my (Rocket R58 2019) hands down and less expensive too. I'm now jealous of my mom's machine that I bought her lol.

    • @LELIT_Official
      @LELIT_Official  2 роки тому

      Hello, we appreciate your feedback! If you need support, we invite you to send an email to care@lelit.com, our Customer Care will be more thank happy to give you all details. We remain at your disposal. Thank you, LELIT Team

    • @Hacka_tv
      @Hacka_tv 2 роки тому +1

      yea same for me, i will have to adjust it too

    • @martinkulik9466
      @martinkulik9466 2 роки тому +3

      With coffee puck there is pressure loss, so if you get 10 or 12 or whatever don't matter, what matters is what pressure you get during extraction....if you drop to 9 you might have weaker extraction.... Again 9 bar is during espresso, not during blanked grouphead

    • @LELIT_Official
      @LELIT_Official  2 роки тому

      @@martinkulik9466 Hello, please contact directly our Customer Care at care@lelit.com and we will follow up from there. Thank you, LELIT Team

    • @Hacka_tv
      @Hacka_tv 2 роки тому

      @@martinkulik9466 the pump ressure shown on the bottom right of the machine shows 10 bar, not the puck pressure barometer

  • @misenko856
    @misenko856 5 років тому +4

    On my bianca the pump pressure is set exactly to ten bar but with blind filter the head pressure shows 11.5 bar when fully open. Is this normal or is there any problem? Thank you.

    • @LELIT_Official
      @LELIT_Official  5 років тому +2

      Hello,
      a difference of 1/1,5 Bar between the pump pressure gauge and the coffee group pressure gauge is normal in the Bianca machines.
      The pressure gauge placed on the panel, it shows the value of the delivery pressure of the rotary pump before the gicleur. Whereas the pressure gauge on the group, it shows the pressure on the coffee puck, which is also influenced by the expansion that occurs in the coffee boiler. So, during the coffee extraction, I suggest you to consider the pressure of the group pressure gauge.

    • @misenko856
      @misenko856 5 років тому

      @@LELIT_Official Thanks a lot for the response. All is good then. It's a great machine btw ;)

    • @LELIT_Official
      @LELIT_Official  5 років тому

      Thank you!

    • @AlexKozhevnikov-f1w
      @AlexKozhevnikov-f1w 5 років тому

      @@LELIT_Official Hi, but could you please tell something about ANITA PL042EM? The pressure on manometre (blind filter) is 8.5 bar, and during brewing it drops to 7.8-7.9. Should I adjust the OPV to get 9.5-10.0 bar with blind filter, so that, 9.0 during brewing, I hope)?

    • @LELIT_Official
      @LELIT_Official  5 років тому

      Hi! Please address this specific question directly at support@lelit.com. Kindly send also a picture of the data label applied on the back of your ANITA. Thanks!

  • @TheToman1
    @TheToman1 2 роки тому +1

    I adjusted the pressure as explained in the video to 9 bar, but during the extraction the grouphead pressure gauge reaches slightly beyond 10 bar! and doesn’t stop at 9 bar. why?

    • @LELIT_Official
      @LELIT_Official  2 роки тому

      Hello, we know you are already in contact with our Customer Care per email. You will be supported from there. We remain at your disposal. Thank you, LELIT Team

  • @HaveAGoodHeart
    @HaveAGoodHeart 2 роки тому +1

    May I know the reason for setting it at 10.5 bar at factory?

    • @LELIT_Official
      @LELIT_Official  2 роки тому +1

      Hello, we inform you that this value is within the range considered ideal for machines concoived for domestic use. We remain at your disposal. Thank you, LELIT Team

  • @specker63
    @specker63 Рік тому

    Is it a fail , if the pump pressure is 12bar? Should I reduce it? Why?
    Regards and Thanks!

    • @LELIT_Official
      @LELIT_Official  Рік тому

      Hello, thank you for your comment. To better support, we invite you to send an email to care.foryou@lelit.com attaching a copy of your purchase invoice, a photo of your product data label and a short video showing the mentioned situation. Our Customer Care will do their best to provide assistance. We remain at your disposal. Thank you, LELIT Team

  • @simplelife5435
    @simplelife5435 5 місяців тому

    Just received my Bianca from service. They changed the pressure to 9 bars. Should it be 10?

    • @LELIT_Official
      @LELIT_Official  5 місяців тому +1

      Hello, please note that the OPV is set in the range 9-10.5 bar with the tollerance of -/+ 0.5 bar. Thank you, LELIT Team

  • @md.farid500
    @md.farid500 Рік тому

    Is there a specific reason why the factory default pump pressure is set to 12 bars?
    What would be the pump pressure that I should adjust to if I want my espresso extracted at 9 bars?

    • @LELIT_Official
      @LELIT_Official  Рік тому

      Hello Muhammad, thank you for your comment. To better support, we kindly ask you to forward your request to care.foryou@lelit.com attaching a photo of your product data label. Our Customer Care dept will be more than happy to support you. Thanks and best regards, LELIT Team

  • @barjee
    @barjee Рік тому

    I adjusted mine slightly a few months ago but was able to move the screw without loosening the lock nut, should that not happen?

    • @LELIT_Official
      @LELIT_Official  Рік тому

      Hello, thank you for your comment. To better support, we kindly ask you to send an email to care.foryou@lelit.com attaching photos or videos of the issue and your product data label. Our Customer Care dept will be more than happy to help you. Thanks and best regards, LELIT Team

    • @barjee
      @barjee Рік тому

      ​@@LELIT_Official a picture of what? It doesn't look any different than normal

    • @LELIT_Official
      @LELIT_Official  Рік тому

      @@barjee Hello, we invite you to report the issue to our Customer Care dept, they will surely be able to provide assistance for this case. Their email address is care.foryou@lelit.com. We remain at your disposal. Thank you LELIT Team

    • @bogdanadzic9305
      @bogdanadzic9305 Рік тому

      ​@@barjeedid u sort it out

    • @bogdanadzic9305
      @bogdanadzic9305 Рік тому

      ​@@barjeeu have simulae problem i cant rotate the black part without changing punp presure

  • @ianfebriyanto
    @ianfebriyanto 2 роки тому

    total power is 1550watt (I noticed that when you adjusted the pressure)? I thought it was 1400w brew boiler + 1400w steam boiler, so 2800w in total.

    • @LELIT_Official
      @LELIT_Official  2 роки тому +1

      Hello Ian, please note that we have just replied you to your mail concerning this issue. Thank you, LELIT TEam

  • @MisterKnif3
    @MisterKnif3 3 роки тому +1

    After a year of use my rotary pump now goes to 14 bar and only let itself lower to 12. I tried these steps but I can’t get it lower. Any tips?

    • @LELIT_Official
      @LELIT_Official  3 роки тому

      Hello, thank you for using our product. please send your message to care@lelit.com and we will follow up from there. Thank you, LELIT Team

  • @TYRONNOAGE
    @TYRONNOAGE 7 місяців тому

    Ciao io ho una LELIT MARA X, e per tutti i 25 - 30 secondi di erogazione sta sui 2 3 bar..fa fatica. a raggiungere i 9 BAR, solo all fine, infatti viene acquoso, e zero crema, cosa consigli ? provato a diminuire quantità ma stessa che usavo prima, è da 2 mesi che no la usavo, unica cosa che mi viene in mente

    • @LELIT_Official
      @LELIT_Official  7 місяців тому

      Buongiorno, La invitiamo a inoltrare la Sua richiesta al nostro Customer Care, inviando un'e-mail a care.foryou@lelit.com, allegando un video della situazione descritta, una foto dell'etichetta dati prodotto e una copia della fattura di acquisto. Rimaniamo a disposizione. Grazie, LELIT Team

  • @mun-shammary
    @mun-shammary 4 роки тому

    Help me after i did like this video ! When i control the bar from the manual paddle ! The gage not moving !!!

    • @LELIT_Official
      @LELIT_Official  4 роки тому +1

      Hi, pls send a video to care@lelit.com, they will follow up from there. thanks!

  • @amrelwi9413
    @amrelwi9413 5 років тому

    Please help, my bianca’s brew gauge isn’t working or make any reading is that maybe because of the grinding size or it is a machine failure??

    • @LELIT_Official
      @LELIT_Official  5 років тому

      Hello Amr! Help us to better understand the situation: pls send a picture of the data label applied on the bottom of the unit and a video of your Bianca during coffee brewing directly at care@lelit.com Thanks!

    • @mun-shammary
      @mun-shammary 4 роки тому

      LELIT i adjust the bar like in this video ! Now the gage in group head not moving ! Help pls ..

  • @matteocannas2152
    @matteocannas2152 2 роки тому

    Ciao, vorrei sapere se esiste un video che spiega come regolare la pressione di una Kate PL82T, è da un po di tempo che è passata dai normali 10 bar a quasi 8. grazie

    • @LELIT_Official
      @LELIT_Official  2 роки тому

      Buongiorno, La informiamo che il nostro Customer Care ha risposto via ticket / mail alla situazione segnalata. Grazie, LELIT Team

  • @eddieyung2927
    @eddieyung2927 2 роки тому

    Where do you get the Lelit t shirts?

    • @LELIT_Official
      @LELIT_Official  2 роки тому +1

      Hello Eddie, thank you for your question. Please note that unfortunately the LELIT T-shirts are not for sale. Thank you, LELIT Team

  • @imranmclaoda17
    @imranmclaoda17 2 роки тому

    Apakah bisa menyedot air langsung dari galon? Karena sy melakukan hal tersebut, tetapi manometer pump tidak stabil.

    • @LELIT_Official
      @LELIT_Official  2 роки тому

      Hello, we kindly ask you to send an email to care@lelit.com attaching a photo of your product data label and a video showing the described situation. We remain at your disposal for any issue. Thank you, LELIT Team

  • @rottiejakeluke
    @rottiejakeluke 4 роки тому +1

    Where/when is less pressure desired? Additionally, where/when is more pressure desired? I live at one mile above see level. Do you recommend any special pressure to be used? Why? Thanks

    • @LELIT_Official
      @LELIT_Official  4 роки тому +1

      Hello,
      For a correct functioning on the machine, the pump needs to work between 9 and 11.5 bar. There are particular cases where clients prefer different settings, for more details this regards please contact your direct Lelit reseller. Thank you!

  • @musomaster9027
    @musomaster9027 3 роки тому

    Can you do something similar in Lelit Kate?

    • @LELIT_Official
      @LELIT_Official  3 роки тому

      Hi, thank you for your comment. We will take note of your suggestion for future videos. LELIT Team

    • @jakubzbroda
      @jakubzbroda Рік тому +1

      Yes, you need to adjust the OPV valve. It requires some disassembly.