    Don't to this hack go get a recovery machine and a recovery tank

КОМЕНТАРІ • 24

  • @devenu5719
    @devenu5719 Рік тому +2

    Very informative thank u kind sir

  • @Honestandtruth007
    @Honestandtruth007 3 місяці тому +1

    I wish you Show more steps during your Next installation and Good job 👍

  • @captainstark5601
    @captainstark5601 Рік тому +2

    What a hardworking man, his future wife is gonna be very lucky to have him as a husband ✊👏

    • @Phone-sh7jg
      @Phone-sh7jg 6 місяців тому

      I hope she has a big johnson!

  • @GoOp790
    @GoOp790 9 місяців тому +2

    Are RunTrus quality units? Thinking of having one installed

    • @vivaj1421
      @vivaj1421  9 місяців тому +1

      There are good say it like a train ac system but it’s a cheap alternative way have the same parts and everything as a train unit

  • @pkprince14
    @pkprince14 3 місяці тому

    Do you know if the RunTru evaporator coils come with the TXV valve already installed inside? I am getting ready to purchase and install one of these, but I can't find any clear documentation online stating whether or not I need to order a TXV seperately.

    • @travistalkington9297
      @travistalkington9297 3 місяці тому +1

      They come with a piston metering device so you will have to have a txv ordered and put in if you want one.

    • @pkprince14
      @pkprince14 3 місяці тому

      @@travistalkington9297 Ok. I hear txv's are better, so I may remove the piston and install the TXV if it's possible.

    • @travistalkington9297
      @travistalkington9297 3 місяці тому +1

      @@pkprince14well it depends on better. They are more efficient but more that can go wrong. With a txv the can become clogged like a piston but the txv can also loose its charge in the bulb and then can no longer regulate the superheat properly.

    • @pkprince14
      @pkprince14 3 місяці тому

      @@travistalkington9297 I see. Good to know! Maybe I'll keep it as is then. Thanks!

    • @travistalkington9297
      @travistalkington9297 3 місяці тому +1

      @@pkprince14 also if your putting the system in yourself and have excess return flex duct do not just pull it back into the attic that is just going to restrict the flow and cause the unit to be less efficient.

  • @chainslaughter231
    @chainslaughter231 3 місяці тому +4

    I would!ct recommend venting refrigerant either. I also wouldn't recommend uploading a fuckin video of you doing online while openly stating you're doing it. Jeebus man

    • @Hvacnc
      @Hvacnc 2 місяці тому

      Exactly. Wtf is this dude thinking posting it. Sheeesh

  • @vectorm3832
    @vectorm3832 Рік тому +2

    Come fix my pipes 😫

  • @dm0320
    @dm0320 Рік тому +2

    BISCUIT

  • @lilalex4194
    @lilalex4194 Рік тому +3

    Brother be careful EPA could watch this video

  • @Khn83
    @Khn83 10 місяців тому +2

    Be careful dumping Freon like that bro… The KGB.. I mean EPA will bust you for it.

  • @Gabriel-vz7ml
    @Gabriel-vz7ml 8 місяців тому +1

    Sounds like it was overcharged😅

  • @Gabriel-vz7ml
    @Gabriel-vz7ml 8 місяців тому

    Why are you whispering?