Filter Drier || Refrigeration || HVAC Tamil ||

Поділитися
Вставка
  • Опубліковано 2 лют 2025

КОМЕНТАРІ • 49

  • @venkateshrathinam7657
    @venkateshrathinam7657 2 роки тому +1

    Very useful video
    Explain about return signal wiring in contecter

  • @ashwathraj4594
    @ashwathraj4594 3 роки тому +2

    Bro appidiyae star delta connection explain pannunga

  • @sugumars8168
    @sugumars8168 3 роки тому +1

    Super

  • @Shamu-ij8xu
    @Shamu-ij8xu 2 роки тому

    Very useful information bro thankyou very much 🙏🙏

  • @tharishankar1999
    @tharishankar1999 3 роки тому +2

    Sir... I am watching your videos regularly... It is more useful... And you teaching very well...you have a good heart...THANKS SIR... 🙏

    • @jollyscaria1922
      @jollyscaria1922 Рік тому

      Drie filter the function of the dirier filer is to removing moisture and dust particles from the refgerntv .dust particcles cause blcking at therefrigernt control moisture also cause blocking by freezing by freezing insidetheevaporatrs derfrnt modes thrd typ 2side welding fixing deire core type fee derfrindmoders fee maing filtsziing maung reson ba thankyougues ..

  • @pavunkumar9852
    @pavunkumar9852 11 місяців тому

    Nice experience

  • @kathiravan.k3248
    @kathiravan.k3248 Рік тому

    🔥🔥🔥🔥🎉🎉🎉🎉super anna

  • @vijaydaniel5567
    @vijaydaniel5567 2 роки тому

    Thankyou sir very useful video

  • @mohamedjameen6039
    @mohamedjameen6039 3 роки тому +1

    It's long days after coming so we r very proud and happy bro.

  • @Nethaji55824
    @Nethaji55824 3 роки тому +1

    Nice sir thanks sir...

  • @rajendrannages932
    @rajendrannages932 3 роки тому

    Good information.

  • @kkamal92
    @kkamal92 3 роки тому +1

    Sir please explain about Pressure Independent Control Valve used in chilled water pipe lines...

  • @mohamedafzal713
    @mohamedafzal713 3 роки тому +3

    I had a interview for FM Engineer! They asked me about only super heat in depth. How do you calculate super heat, what is idle range of super heat with example, superheat issues and finally enthalpy of vapour absorption cycle. Please can you explain about these in your upcoming videos it will be very helpful. I am regularly following you up.🤝🤝🤝

  • @mohammedyousuf2091
    @mohammedyousuf2091 3 роки тому

    Usefull video sir

  • @ashwathraj4594
    @ashwathraj4594 3 роки тому +1

    Romba thanks bro

  • @nithyamohan1241
    @nithyamohan1241 3 роки тому

    Arumai brother

  • @hafeelrahman3768
    @hafeelrahman3768 3 роки тому

    So if we need to replace the filter dryer, we need to isolate the ac system right ? Need to refill refrigerant ? Please explain

  • @kathiresanthaavethu3128
    @kathiresanthaavethu3128 3 роки тому

    நன்றி

  • @RajKumar-nw7mm
    @RajKumar-nw7mm 3 роки тому

    Atfd Video podunga Sir.

  • @ashwinkumark1839
    @ashwinkumark1839 2 роки тому

    Hello sir, can we use anti- moist (anti choke) in all refrigerants. R22 R32 R407c R410a R600a R290a . We are using in R134a Can you explain us.

  • @rrdeen8744
    @rrdeen8744 3 роки тому

    Hi bro
    What is
    target Superheat.
    EVAPORATOR superheat.
    Total superheat.
    Fixed metering & txv system changing method

  • @powereletro3162
    @powereletro3162 2 роки тому

    👍

  • @nawaznawaz6459
    @nawaznawaz6459 3 роки тому

    AC unit problem and rectified video upload pannanuga sir please

  • @mohamedharish1977
    @mohamedharish1977 3 роки тому

    Make a video for How to calculate the filter size ...

  • @jaishankarjayakumar9188
    @jaishankarjayakumar9188 3 роки тому

    Then why we use oil separators

  • @alagarraja7647
    @alagarraja7647 Рік тому

    Alumina epoxy and molecular. Bro inthu DCL core...DML la Epoxy and molecular

  • @madhavanmadhavan3199
    @madhavanmadhavan3199 3 роки тому +1

    Hi bro new subscriber

  • @shivaHVAC
    @shivaHVAC 3 роки тому

    Hi bro.. what is the use of drift eliminator in cooling towers..pls tell me bro. Waiting for your reply..

  • @devinchan7531
    @devinchan7531 Рік тому

    Sight glass pathi padinga ... For filter drier check up

  • @nazimnazim315
    @nazimnazim315 2 роки тому +1

    Bro entha.... video kosam naaa onga chennal la subscribe panni erukaa...bto....
    Enthaa mathi reee niga neraya video poduviga nu naa ga yathir paakurom.

  • @arjuna9366
    @arjuna9366 3 роки тому

    Bro nenga professor ah poidunga bro 💯

  • @munimech7751
    @munimech7751 3 роки тому

    Hi sir , thanks for the information.and plz explain air cooled Chiller oil circuit🙏.

  • @saranbala9529
    @saranbala9529 11 місяців тому

    Sir tamilla shillings sir

  • @jollyscaria1922
    @jollyscaria1922 Рік тому

    Drier filer inside metrs .. drier filter dissicant .filter .fare conneection .other strainer ... at drier filters is used to removing mosisture and dust particles from the liquied refrigernt dust partical in the refrigerant cause blocking at the refrigerantcontrol.. at mosheric air al wayscotaing water vapouer the refigernt charged in a systom many contain samll quantity of air and water vaourif evacuation is not done porperly the remaining air in the systom also contiain water vapourwhen the temperature of this water vapour decres below 32 °fin evaporater it freezers and cause blocking at the capillary or inside the eva porator when moisture circulaates compres or the motor wind ing may burn or valve may damaged hp ad cubic ich compressr hp and compring using drier usingsiz okexpls 2 inch dries size comprsser 1/8using other exples 3ich ..cmprssar ..1/6to 1/4 using om lot size bai one mores explas 6inch cmprs... 1/4to 1/2...using ..12ich cmrss..3/4to 1inch usinv ok bsis
    .tjankyou

  • @syediburam6373
    @syediburam6373 3 роки тому

    இதே போல் தான் tx value இல்லாத Unit களில் கேப்லரிட்யூப் Chilinga இருக்கும்.