How to wire a Safety Relay / Safety relay working principle / Best video for you to learn..!!😍💪

Поділитися
Вставка
  • Опубліковано 4 жов 2024

КОМЕНТАРІ • 40

  • @ElectroAcademyEA
    @ElectroAcademyEA  Рік тому +2

    Hi, Dear All,
    Just a kind request to the viewers and professionals who can afford to sponsor or fund this channel, mainly for the benefit of the viewers all over the world.🌎🗺✈
    It will also definitely be a motivation for me, to continue this channel with good explanatory educational videos for all of you.
    You can contribute by being a Sponsor of this channel using the following link, patreon.com/ElectroAcademy
    I made this request few months ago, and now we have one patron who has come forward to help this channel.💪💪
    I love it from my bottom of heart. ❤❤❤
    I know, generally entertainment channels get quite a lot patrons for their support, but look forward to see some more supporters who understand the value of an educational channel like this.
    Your kind gesture will be most welcome..!😍👍
    Thanks and Best regards.
    Sudarshan,
    Creator of Electro Academy Channel.

  • @НиколаЂорђевић-х3м
    @НиколаЂорђевић-х3м 15 днів тому +1

    One of the best tutorials I have ever watched. Thank you a lot for this great work.

  • @sindicta5757
    @sindicta5757 Рік тому +2

    I was looking for a vacuum replacement part and Amazon accidentally came up with safety relays and now I'm here.
    I'm not even an electrician, I'm an artist.
    Thanks for satisfying my curiosity

  • @bonnylasu7665
    @bonnylasu7665 Рік тому +1

    Hi Sir good day. Thank you very much for very nice teaching video of electrical installation.

  • @raquelsapalaran2907
    @raquelsapalaran2907 Рік тому +2

    one of the best video tutorial❤

  • @mrtrader4628
    @mrtrader4628 Рік тому +1

    Very good please keep them coming

  • @Sami.3939
    @Sami.3939 Рік тому +1

    Nice information

  • @okonkwoandrew5880
    @okonkwoandrew5880 Рік тому +1

    I can't finish my expression over the result of your videos i give and spend my time following and watching your videos. I wish to have a direct contact and connection with you guys for more. kudos

  • @healthinformationHI
    @healthinformationHI Рік тому +2

    Wow. Nicely explained 👌

  • @andrewgalias8668
    @andrewgalias8668 5 місяців тому +1

    Excellent video

  • @allanrodriguez1308
    @allanrodriguez1308 Рік тому +6

    I often encountered these safety relay often bypass because they say that it is hard to troubleshoot due to to many wirings, sensitivity and interlocks. That is why you need to know the importance and the purpose of thess safety relays and the consequences if you did bypassed it

  • @luchomartinez338
    @luchomartinez338 9 місяців тому +1

    Excelente. Gracias

  • @peterpanini96
    @peterpanini96 10 місяців тому +1

    Majestic. 🤗🤗🤗

  • @SusilTech
    @SusilTech Рік тому +2

    Amazing video 👍

  • @xanime6566
    @xanime6566 11 місяців тому +1

    Thank you

  • @juankiriluk5864
    @juankiriluk5864 2 місяці тому

    Why do we need a Master Relay before the Magnetic contactor?

  • @michaelcostello6991
    @michaelcostello6991 Рік тому +1

    Greatttttt

  • @user-ri8hd4bo8k
    @user-ri8hd4bo8k 11 місяців тому +1

    Emergency stop doesnt stop the circuit ?

    • @ElectroAcademyEA
      @ElectroAcademyEA  11 місяців тому

      If the motor running contactor has a contact welding condition, emergency stop cannot stop that faulty contactor from operating.

  • @michaelcostello6991
    @michaelcostello6991 10 місяців тому +1

    S12 supplies 24 V to S34 to reset. Is s12 just looking at channel 1 ? Please advise.

    • @ElectroAcademyEA
      @ElectroAcademyEA  10 місяців тому

      S11-S12 and S21-S22 are input switches and must be in the closed position for internal contactors K1 and K2 to be closed.
      Contactors K1 and K2 (placed inside the safety relay) must be in the closed position for control power to be available at terminal 14.
      Although 24 volts for reset power have been connected from S12 of channel 1, the system cannot be restarted without channel 2 enabled.
      So, the motor run contactor control power will not be out from terminal 14, without closing both the S11-S12 and S21-S22 switches.

    • @michaelcostello6991
      @michaelcostello6991 10 місяців тому

      @@ElectroAcademyEA Thank you very much for clarifying this. Please do more safety videos as there as so many different types of safety controllers in industry

    • @wyedelta9628
      @wyedelta9628 18 днів тому

      @@ElectroAcademyEA why we need to ground s21

  • @Eduardo-mg7zm
    @Eduardo-mg7zm Рік тому +1

    💕 *Promo SM*