Sa mga gostong pong humingi kong pano mag address ng fire alarm DEVICE na may depth switch paki lagay na lang po ng gmail acount sa may comment section at bibigyan ko.
in 4:39 mark of the video, that's what you called SELECTIVE SIGNALING. This applicable especially for high rise building where the rule fire above and below of the floor notification appliances will only be activated. This to avoid stampede during evacuation. If not for this rule, in case of fire the whole building fire alarm bell and horn strobe activated simultaenously, then tenants of the building will evacuate at once which eventually caused stampede.
To add more info's sir, some other addressable brand like ZETA its loop wiring to all devices should be in reverse polarity, example in the base of detector L1 and L2 is negative and the common is positive.
nice po master napakalinaw nio magpaliwanag..newbie sa fdas and new subscriber nio po..Master tanong lang po. 1.Sa addressable loop po tawag?sa conventional naman po is Zone? 2.Sa addressable po master no need na po ng resistor no?thank u po master sana masagot newbie lng po sa fdas
General alarm sir Ang protocol sa lahat Ng fire alarm system Lalo nat iisang building..kung magkakahiwalay Ang building pero monitored by one panel pede rin izoning Ang alarm sounder especially sa mga hospital
Sir gud pm po sa adresable po may nabangit nyo po na may balik sa positive sa huling smoke detector..saan po ba nakalagay sa panel ung balik na suply..
Don din sa terminal kong san nagmula ang wiring mo simula umpisa ang return ng wiring mo don din babalik yon..sir magkapit lang sir pisitive at negative lang din yan kasi may polarity
Good pm po sir Jub, pede po bang ipagsama sa iisang loop ang Manual Pull Station, Alarm with Strobe Lights, Bell at Smoke Detector? Salamat po sa magiging kasagutan niyo po.
@@jub.tv123 pero sa loop 1 smoke detector lang lahat at sa loop 2 serin with strobe light lahat. At sa loop 3 heat detector at manual call point tama ba sir?
Sir kung tama po ako sa idea ko pwede ko pong i-convert ang wiring ng addressable sa conventional need ko lng lagyan ng Resistor dun sa dulo na bumalik sa panel salamat po sa pagsagot, 2nd question ko po sir pwd ba na hindi ko na palitan yung mga smoke na ginamit sa addressable kung i-convert sa conventional nlng salamat po
Nice. Saan ang lugar mo. Why not mag-set up ka ng a day and I will lecture sa Pinas. Visiting Lecturer. You can invite all electrician and FDAS people. My other channel "Ako Sa Sydney"
Sir halimbawa po sa isang unit po meron na po sya naka abang na isang smoke detector tapos po dadagdagan po sya ng smoke detector, pano po gagawin sir sa panel, addressable po sya sir
Pag gosto mo e disable sir. Ang detector tanggalin mo sa sa termination at e connect mo ulit ang cable na tinanggal mo sa device para tuloy ang flow ng current tapos e delete mo sya sa panel para walang truoble na nakalagay don...
Boss, halimbawa po ihiwalay ko na sa circuit ng mga smoke detector yung manual call point. Pagsasamahin ko nalang sila puro manual call points halimbawa sa zone4, then separate circuit puro smoke detectors sa zone 1 at zone 2, kitchen area heat detectors sa zone 3. Pwede po ba iyon. Yung wala sila manual call point smoke at heat detector circuit
Wag mo pa hiwalayin sir isama mo parin ang smoke detector mo at sa manual call point mo at heat detector mo kasi baka wala kna mailagay sa terminal mo pag may another zone ka na idadagdag....
Ang addressable system ang pinaka madaling imaintenance, alam mo agad saan ang problema di gaya ng conventional maraming gala at tingala ang gagawin mo para makita saan problema.
Sir ang smoke d nag alarm yan..ang trabaho ng smoke ay to detect lang konh may usok...para maibato nya sa FACP. tapos tataas ang current saka mag alarm si bell at strobe ..
sir meron kami main panel sa guard house tas mag iindicate dun kung anong planta ang may alarm ..yung isang planta d nag iindicate ng alarm .. ano po possible problem at pano wiring papunta sa panel sa guard house.. san po yun nakacconnect sa panel na nasa planta kung san may alarm . aning terminal ang nagbabato ng signal sa main guard house?? salamat po
@@jub.tv123 meron naman po sir may naginspection po kase pero d ko nakita actual sabi nya d daw po nagbabato ng signal dun sa panel na nasa guard house may possible daw po may putol na wire papunta sa guard house ..san po kaya nanakonnect yung wire nung sinasabi nya ? or aling connection terminals yung irerewire ko?
hindi sir individual dapat ang wiring...every zone.. sa device dapat 20 device lang every zone... para dka mahirap kag locate pag may trouble ang device mo
Boss bakit yong call point tenest ko nag fault sa panel pero hindi nag ring ang bell,tapos tenest ko ang smoke detector na kasama nya sa circuit nag eergized naman Bell ano ang problema doon boss.salamat sa sagot
Sir anong ba ang system ng fire alarm nio?..at ang tenest moba na mCP. isa lng sila ng loop ng Smoke detector na tenest nong nag activate ang bell mo?..
Ang addressable fire alarm system sir aay ang mga devices nya ay nakaprogram sya or naka address at naka ring ckt. Connection sya..ang ring ckt connection ay pag out nya ang last wiring wiring device ay babalik yan sa FACP. may return cya .. ang conventional namn sir aY d naka address. Ang deviceS at d naka ring ckt. Pero ang last na wiring mo ay may END OF LINE RESISTOR SIR ..
flow switch.. po sir mayron. po . sa springler yan na thermal operating element. normally fusible links or glass bulbs.. na kong sakaling may sunog maabot nya ang temperature yan ay mababasag ... at mag spray Ng tubig ang springker mo or foam....
brod nakapagkabit kana ba ng ganyan..kac dtu ginagamitan ko ng CC1 yung sau wala aku nakikitang CC1..kac parang kulang..sorry brod nagtatanung lang..kapag addressable kac my CC1 dahil pinoprogram lahat na device sa FAP..
korek po sir baka defective na po ang device at d nya nabasa pag program.. try mo palitan ... marami po ba ang device nio na ganyan... at baka ang panel mo at device mo ay mag kaiba Ng brand...
Alin ang tinatanong mo sir ang naka program ang conventional ang device ba? Kong ang device hindi... ang naka program lang kong device ay addressable na device.. lang....
Ok sir salamat andito ka ba ngayon sa saudi gusto ko Sana lumipat sa electrical nasa piping kase ako ngayon gusto maka pag experience ng instrument Sana graduate po ako ng electrical technology
kailangan Ng laptop yon sir... e connect mo sa FACP... saka mo e program... ang no. Ng devices mo at location nya at aNg looping Ng alarm... kailangan tama ang pag program Ng device mo halimba notification... kgaya Ng detector device smoke or mcp. tapos yon alarm. BELL or strobe light..
@@jub.tv123 Ang sign na fire alarm sa FACP Ang umiilaw,Di Ang device..pinalitan ko na Ang mga devices sa zone na Yun,nilinis kopa baka may alikabok,,mgtrigger talaga sa panel
Iba talaga paliwanag kapag ka may actual experience ka sa site, I salute to people like you Sir..
Sa mga gostong pong humingi kong pano mag address ng fire alarm DEVICE na may depth switch paki lagay na lang po ng gmail acount sa may comment section at bibigyan ko.
normandavid294@gmail.com
Hello sir, paki suyo nalang po. "bhomar.bancale@gmail.com" . Thank you
New subscriber po pa hingi rin po ako idoll.. slamat po sa video tutorial nyo po..
marlonsarazabinuya@gmail.com
asiadonhadz@gmail.com . Thanks lodi .
Mahusay klaro ang pag babahagi ng kaalaman, salamat madaming salamat
Salamat kuya sa iyong mga turo bagong kaalaman sakin to
Dami ko natutunan salamat idol
Malinaw ang paliwanag mo Sir, the best ka talaga.
in 4:39 mark of the video, that's what you called SELECTIVE SIGNALING. This applicable especially for high rise building where the rule fire above and below of the floor notification appliances will only be activated. This to avoid stampede during evacuation. If not for this rule, in case of fire the whole building fire alarm bell and horn strobe activated simultaenously, then tenants of the building will evacuate at once which eventually caused stampede.
Salamat sir sa pagtutoro
Very good tutorial💖 watching iloilo tech
Sir ga kabit kamo automatic alarm,location mo
Ang galing
Imformative ... Ty sir
Salamat idol
thanks for the tutorial idol....
salamat po sir sa tutorial nyu.
Ayos boss
Salmat kabayn
Salamat sa pagsagot sir,,pero sir diko talaga gets,,kasi close.system diagram With four smoke detector,,salamat sa sasagot,,god blz u always
sir diagram... lang na apat na devices yan pero innactual pwede ka magdagdag... yan ay reference mo lng.... gobless po sir at ingat lagi
What you speak is beyond of my mind please speak in English thanks Pare
To add more info's sir, some other addressable brand like ZETA its loop wiring to all devices should be in reverse polarity, example in the base of detector L1 and L2 is negative and the common is positive.
Magaling kapa sir...salamat sa info mo...
nice po master napakalinaw nio magpaliwanag..newbie sa fdas and new subscriber nio po..Master tanong lang po.
1.Sa addressable loop po tawag?sa conventional naman po is Zone?
2.Sa addressable po master no need na po ng resistor no?thank u po master sana masagot newbie lng po sa fdas
Depende po kong nag kaka error pwde din po lagyan ng resistor kahit addressable...sya...pero sa conventional mostly may resistor po...
General alarm sir Ang protocol sa lahat Ng fire alarm system Lalo nat iisang building..kung magkakahiwalay Ang building pero monitored by one panel pede rin izoning Ang alarm sounder especially sa mga hospital
Sir wala po kayong panel configuration 😊😊😊😊
Nice one Master.. May natutunan na naman po ako... Ask lng Master pag addressable ba di na need nang EOLR....
Hindi na sir
Nice Master
Sana yung actual naman na pag terminate nang addressable fdas....
Master,, may tanung po ako
patingin po ako ng connection ng (addressable)sa loob po ng panel!
Kung paano mo po na connect
Sa mga temenal
Pasensya na sir wala na ako ngayon sa fire alarm sa construction na ngayon ang work ko..
Sa coventional sir sa issng zone. Pwed ba na mglagay ng tatlo hanggang apat na strove pero nka pararel lng
Sir kaya po ako ako nagtanong dahil mag take po ako ng NCII ,Sana maipaliwanag po ninyo sa susunod ninyong blog.salamat po.
Ang addresable sir is loop wire ang nilalagay at sa conventional ang end nya ay EOL resistor tama po ba?
Addressable po Tanung Ku LNG po sir ok LNG po ba na naka bypass / jumper po ba ang loop in at tska loop out?
Sir gud pm po sa adresable po may nabangit nyo po na may balik sa positive sa huling smoke detector..saan po ba nakalagay sa panel ung balik na suply..
Don din sa terminal kong san nagmula ang wiring mo simula umpisa ang return ng wiring mo don din babalik yon..sir magkapit lang sir pisitive at negative lang din yan kasi may polarity
A ok po kala ko sa batery...salamat po sir...
Sir ask ko din po kung pwedi ndi kana mag return, smoke detector to panel board at sa strobe light/alarm? salamat sir..
Good pm po sir Jub, pede po bang ipagsama sa iisang loop ang Manual Pull Station, Alarm with Strobe Lights, Bell at Smoke Detector? Salamat po sa magiging kasagutan niyo po.
Pahabol po pala. Yung mga components po ba para sa addressable ay hindi pede gamitin sa conventional FACP? Or Vice versa po. Salamat po ulit.
good evening ser,,,Ang addressable alarm bell niya kailangan May return talaga ser,, salamat po..
Opo sir kasi kong sakali maputol sir sa gitna at kong sang parte man may signal parin po.....at supply parin boo parin
@@jub.tv123 salamat Po ser,,bagohan lang po...palagi akong nag sobaybay sa mga video mo
@@jub.tv123 good evening ser...may video kaba sa fire alarm intercom Kong paano mag wireng niyan,,,hintay Po ako sa sagot ser.. salAmat po..
sa addressable fire alarm system po ba yun Bell at strobe light kailangan bang meron sariling power supply para gumana?
Salamat
Sir Pg ngpalit ng smoke detector kailagan pa ng programming ng new detector?
Yes sir
Sir, halimbawa magdagdag ako ng detector sa bandang gitna ng system?? mababaho ba lahat ng configuration sa mga susunod na detector??
Hindi namn mag babago yan sir pero e address mo sya... halimbawa last device mo ay 100 ang idagdag mo na address ay 101 102 103
Sir, Ilang minimum ng Smoke detector ang pwedi sa isang MCP?
anong klaseng wire size po ba ang pwede gamitin sa Addressable Fire alarm? Pwede ba gamitin sa lahat ng detector at bell at facp iisang wire size?
Hindi po sa mcp at SD 16 AWG. belden ang brand at sa BELL AT STROBE LIGHT 14 awg.
@@jub.tv123 yung bell po ba kailangan pa ng sariling power supply kahit nasa loop na?
Deritso napo sa FACP panel kong malayo na pero kong malayo kailangan nio ng transponder..
@@jub.tv123 anong aparato po sa fire alarm loop yung kailangan pa ng sariling power supply? sounder po ba?
Ok lng Po ba kahit Anong brand Ng smoke detector, heat detector,manual push button sa addresssable salamat sa sagot
Recommended ko lang po sir yong mganda na brand ( seimens or simplex) ang brand subok napo namin yan...
Boss tanong kolang po,,ano po yung close and open system.sa smoke detector,,diagram,salamat po?,,
Boss ask ko sa addressable ba pag inalis mo ang smoke head at napalitan ng ibang model smoke head posible ba nag maeeror siya.
Opo sir ,, dapat ang ipalit mo ganun parin na brand
Sir sa addressable fire alarm system lahat na ba ng smoke detector.. Bell. Horn with strobe light.. Naka parallel lahat NG wiring connection??
Yes sir naka parallet at naka ring Ckt.
@@jub.tv123 pero sa loop 1 smoke detector lang lahat at sa loop 2 serin with strobe light lahat. At sa loop 3 heat detector at manual call point tama ba sir?
Sir kung tama po ako sa idea ko pwede ko pong i-convert ang wiring ng addressable sa conventional need ko lng lagyan ng Resistor dun sa dulo na bumalik sa panel salamat po sa pagsagot, 2nd question ko po sir pwd ba na hindi ko na palitan yung mga smoke na ginamit sa addressable kung i-convert sa conventional nlng salamat po
Nagka ka error din sir sa panel pag e convert mo ang addressable wiring sa conventional sir dapT pag addressable ay naka ring circuit sya
Sa conventional at addressable sir may resistor ba ung mga sd Nila sa dulo.
Mosrly ginagamitan ng resistor sir ang Conventioanal fire alarm system lang kasi hindi naka ring ckt. Ang wiring nya, kaya may EOLR
Sir ilang oras magagamit ang back up battery if may power supply shutdown?
Required din ba connect sa UPS ang FACP power supply?
Depende sa MAH. ng battery mo sir meang MILLIAMPS PER HOUR
Thank u sir for your very informative presentation.
Sir ok lng po ba kahit d magkaka sunod sunod yong numbering ng mga devices??
Dapat sir magkasunod sunod para mabilis hanapin pag mag trouble shoot,
Sir Jub ask ko lang, pwede ba sa isang loop magkakasama ang smoke det.,heat det, mcp at strobe/bell?
Pwede sir
@@jub.tv123 thanks, sir jub!
Nice. Saan ang lugar mo. Why not mag-set up ka ng a day and I will lecture sa Pinas. Visiting Lecturer. You can invite all electrician and FDAS people. My other channel "Ako Sa Sydney"
Dito po ako sa ibang bansa sir...sa HUNGARY
@@jub.tv123 hahahaha...akala ko sa Pinas. Ingat Lagi.
Good pm, sir pag wireless po ang gagamitin need parin poba ng program ng panel para sa smoke? Salamat sir god bless
Opo sir
Hello po tanong ko lang po kapag addressable wala po sya end of line na may resistor ?
Pwdeng wala na kong walablng error sa FACP
Paano ba boss mag configure sa address f ever magpalit ka ng new smoke detector sa addressable type na fire alarm?
Kailangan sir may pang program ka sa devices mo kong may depth swicth e setting mo lang syankong anong device no. Nya
Sir halimbawa po sa isang unit po meron na po sya naka abang na isang smoke detector tapos po dadagdagan po sya ng smoke detector, pano po gagawin sir sa panel, addressable po sya sir
Sir nasagot kona po ang tanong mo sa fb. Page ko..
Master, kada floor ba katumbas non 1 loop? Para kada floor ay halimbawa 2 bell lang gagana
Pwde sir kong maliit lsng ang are mo,
@@jub.tv123 pero sa 1 loop po ba kung 3 bell sounder sa 1 loop, lahat Ung 3 sabay2 na gagana kc Sakop siya ng 1 loop?
Depende sa panel at sa pag program sir at kong anong brand ng FACP. MO
@@jub.tv123 ah ok po, Salamat sa reply master
Idol request nman pano mag disable ng detector?
Pag gosto mo e disable sir. Ang detector tanggalin mo sa sa termination at e connect mo ulit ang cable na tinanggal mo sa device para tuloy ang flow ng current tapos e delete mo sya sa panel para walang truoble na nakalagay don...
Boss, halimbawa po ihiwalay ko na sa circuit ng mga smoke detector yung manual call point. Pagsasamahin ko nalang sila puro manual call points halimbawa sa zone4, then separate circuit puro smoke detectors sa zone 1 at zone 2, kitchen area heat detectors sa zone 3. Pwede po ba iyon. Yung wala sila manual call point smoke at heat detector circuit
Wag mo pa hiwalayin sir isama mo parin ang smoke detector mo at sa manual call point mo at heat detector mo kasi baka wala kna mailagay sa terminal mo pag may another zone ka na idadagdag....
Ang addressable system ang pinaka madaling imaintenance, alam mo agad saan ang problema di gaya ng conventional maraming gala at tingala ang gagawin mo para makita saan problema.
SIR PWEDE BANG ABOUT CONTROL AND MONITOR MODULE NAMAN ANG TOPIC.SALAMAT
Sir ano ang mga factors para piliin mo ang one over the other? Thanks
Boss poidi makangi ng klarong daigram ng addessables fire alarm? Ty and god bless
Message mko sa fb. Page sir JUB.TV don ko e send sayo
Sir pg sa conventional pg ng alarm si smoke detector mg alarm dn si bell, strobe??
Sir ang smoke d nag alarm yan..ang trabaho ng smoke ay to detect lang konh may usok...para maibato nya sa FACP. tapos tataas ang current saka mag alarm si bell at strobe
..
Sir ano po ginagamit n sensor sa kitchen?
Heat detector sir pag sa kitchen hindi pwde ang smoke kasi mausok po ang kitchen..
Saan po ba normali ini install ung fire alarm bill?
sir doon po sa loob ng facp,khit saan po b...pde ilagay ung sd,s,mc...o my nkagay po sa loob ng facp kung saan lng pde ilagay...ty po
sir may ibang module ang sd.. sa id. net card pobyan naka connect and SD.
ang BELL namn or strobe light ay sa MODULE ng NAC. notification appliance circuit..
sir meron kami main panel sa guard house tas mag iindicate dun kung anong planta ang may alarm ..yung isang planta d nag iindicate ng alarm .. ano po possible problem at pano wiring papunta sa panel sa guard house.. san po yun nakacconnect sa panel na nasa planta kung san may alarm . aning terminal ang nagbabato ng signal sa main guard house?? salamat po
Sir tanong ko muna ang device nio po ba na na d nag alarm may power po ba?at anong system po ng fire alarm nio?..
@@jub.tv123 meron naman po sir may naginspection po kase pero d ko nakita actual sabi nya d daw po nagbabato ng signal dun sa panel na nasa guard house may possible daw po may putol na wire papunta sa guard house ..san po kaya nanakonnect yung wire nung sinasabi nya ? or aling connection terminals yung irerewire ko?
Bakit walA po bang tagging?..
Kabayan pag convetional dba dpat may resistor sa end line ?
korek po
Sir ..anung module gamit nyo sa supervisory ?
mkhang 24V yan sir.dalawa e😁
Sir nka seres ho ba yung line1 at line 2 ng zone 1 papunta zone 2. At ilang devices ang maximum sa zone 1
hindi sir individual dapat ang wiring...every zone.. sa device dapat 20 device lang every zone... para dka mahirap kag locate pag may trouble ang device mo
Sir ask ko lang kung pwede s una ilagy ang mcp kasunod nya yung smoke
wala ang problema sir kong San sa kanila ang mauna
mga bos paano sa zone -1 tatlong kwarto tigdalawa ang smoke detictor ilan po ba ang push botton?
Boss bakit yong call point tenest ko nag fault sa panel pero hindi nag ring ang bell,tapos tenest ko ang smoke detector na kasama nya sa circuit nag eergized naman Bell ano ang problema doon boss.salamat sa sagot
Sir anong ba ang system ng fire alarm nio?..at ang tenest moba na mCP. isa lng sila ng loop ng Smoke detector na tenest nong nag activate ang bell mo?..
Sir yung addressional yun ba yung close system diagram,salamat po,,
Ang addressable fire alarm system sir aay ang mga devices nya ay nakaprogram sya or naka address at naka ring ckt. Connection sya..ang ring ckt connection ay pag out nya ang last wiring wiring device ay babalik yan sa FACP. may return cya ..
ang conventional namn sir aY d naka address. Ang deviceS at d naka ring ckt. Pero ang last na wiring mo ay may END OF LINE RESISTOR SIR ..
San po sir sa kanila ang close system diagram sir?
Ang addressable sir
@@jub.tv123 thank you sir,,gud blz you sir,,
Anong device ang e install sir para mag function ang splinkler ng tubig?
flow switch.. po sir mayron. po . sa springler yan na thermal operating element. normally fusible links or glass bulbs.. na kong sakaling may sunog maabot nya ang temperature yan ay mababasag ... at mag spray Ng tubig ang springker mo or foam....
Ahh ok boss...salamat
May video ka nyan boss?
Gamit nmin module sa supervisory ay DCM4 o duel Contact pra flow switch at tamper switch
Hi po sir tanong ko lang po may polarity po ba yung fire alarm at bell?
mayron po sir kasi DC po yan ang red po ay + or positive ang - po ay negative...
Sir , paano po malalaman sa plano Kung ,Ang fda's ay conventional o addressable?
Malalaman po yan sir sa wiring ...pag naka ring ckt. Meaning addressable yan..tapos kong hindi naka ring ckt. Meaniing conventioanal yan.
Ang addressable may supply at return. ang conventional may endline with resistor
brod nakapagkabit kana ba ng ganyan..kac dtu ginagamitan ko ng CC1 yung sau wala aku nakikitang CC1..kac parang kulang..sorry brod nagtatanung lang..kapag addressable kac my CC1 dahil pinoprogram lahat na device sa FAP..
Sa skimatic wiring diagram sir malalaman mo kong conventional or adressable
JUB. TV , sir meron kabang FB? meron sana akung tanung sir salamat
Mayron sir send mo email mo don ko ibigay sayo..
Pwede bang i splice yong wiring ng addressesable
Pwde po
Sir ask ko langpo kung naka experience na po kayo ng unprogrammed device data lumalabas sa HMI. Ano po kaya problema pagganito?
anong klase ba ang fire alarm system nio sir at anong brand Ng device nio?
@@jub.tv123 sir EST3 na brand po addressable nmn po
sir try mo tanggalin at e re program mo ang device kong ganun parin try mo palitan and device...
@@jub.tv123 noted po. Reprogram meaning ulitin ko po magassign ngmga address?
korek po sir baka defective na po ang device at d nya nabasa pag program.. try mo palitan ... marami po ba ang device nio na ganyan... at baka ang panel mo at device mo ay mag kaiba Ng brand...
24v yon DC supply ng system.
Ang sa convensional class b wiring
Sir pag may module po saan po lalagay yung module?
Sa loob po ng FACP PANEL sir..
@@jub.tv123 sir pwde ba yun addressable yung mga module tas yung mga sd conventional?
May tanong ako boss
Nakaprogram din ba ang convincional
Alin ang tinatanong mo sir ang naka program ang conventional ang device ba? Kong ang device hindi... ang naka program lang kong device ay addressable na device.. lang....
Idol ano po trabho nyo bakit pati electrical hawak mo
E & P ako sir electrical at instrument po sir...
Ok sir salamat andito ka ba ngayon sa saudi gusto ko Sana lumipat sa electrical nasa piping kase ako ngayon gusto maka pag experience ng instrument Sana graduate po ako ng electrical technology
ano boss meaning ng mcp? hehehe thanks boss
Manual Call point po..ang mcp...pag sa ilaw sya ang switch mo
sir bakit po nag biblink ang indicator Ng zone 3
San po nag bliblink..sa facp ba sa monitor? Ano ba ang conventiional ba or addressable?..
Sa monitor po.addressable po
Pwde po bang mas malinaw tong diagram pls...
drop po kau ng gmail...para mabigyan kita ng malinaw na diagram..
K sge po... At saka may tutorial video ba ng actual nito?
gagawa palang po sir....
Ko po abangan ko po sir...
cge po
In addressable Fire Alarm system, what is the purpose of isolator base?
Yan ang class A wiring
Sir, paano po mag Program? Tnx
ano e program mo sir device Ng fire alarm or ang fire alarm panel
Yung FACP po sana sir. Hehe
kailangan Ng laptop yon sir... e connect mo sa FACP... saka mo e program... ang no. Ng devices mo at location nya at aNg looping Ng alarm... kailangan tama ang pag program Ng device mo halimba notification... kgaya Ng detector device smoke or mcp. tapos yon alarm. BELL or strobe light..
May ma rerefer kabang manual sir or Tutorial din po?
pag nag program na kmi sir... sa ngayon wala kami gawa sa fire alarm ang pag address lng Ng may depth switch ang mayron ako.....
Sir location mo
Nasa HUNGARY po ako sir sa ibang bansa,❤️❤️
Sir,ano po dahilan,palaging umiilaw Ang Fire Alarm Ng isang zone Ng panel, palaging mg ring Ang bell pag e switch on ko
Sir try mo palitan yan defective na yan sir ang device mo...
@@jub.tv123 Ang sign na fire alarm sa FACP Ang umiilaw,Di Ang device..pinalitan ko na Ang mga devices sa zone na Yun,nilinis kopa baka may alikabok,,mgtrigger talaga sa panel