Why RPM of Delta Motor is High| Which Motor Run Faster Star or Delta| Hindi

Поділитися
Вставка
  • Опубліковано 23 сер 2024

КОМЕНТАРІ • 43

  • @kinjarapujairam7891
    @kinjarapujairam7891 3 роки тому

    Ur explanation is very helpful in interviews sir

  • @RajeevSainielectricals
    @RajeevSainielectricals 2 роки тому

    Very good explanation sir...

  • @imdadullahburdi2247
    @imdadullahburdi2247 3 роки тому

    Good video and taught in very easy and conceptually way.

  • @mohammadrizwanqureshy7142
    @mohammadrizwanqureshy7142 3 роки тому

    👍👍👍👍 Conceptual Explanation Sir

  • @mananpathak9447
    @mananpathak9447 3 роки тому +1

    Perfect explanation 👍 Sir

  • @Tridenux
    @Tridenux 23 дні тому

    Nice explanation 👍👍 thank you

  • @shailendrajadon3599
    @shailendrajadon3599 3 роки тому +1

    Good information sir.....

  • @stindia4484
    @stindia4484 3 роки тому

    Outstanding sir

  • @phoolsingh3658
    @phoolsingh3658 2 роки тому

    Impressive video.

  • @MukeshKumar-zx4gh
    @MukeshKumar-zx4gh 3 роки тому

    Thanks

  • @Allinone950pro
    @Allinone950pro 3 роки тому

    Sir ek question ha ki agar hamara gharme electricity nahi ra to submarsable water pump ( CRI) petrol genarator se chala sakta hai kaya?? Koi diffect hoga ???

  • @jeetnath2689
    @jeetnath2689 3 роки тому

    inductance ka concept . factor about depending inductance ke liye plz kuch video banao sir

  • @bgmigaming4124
    @bgmigaming4124 5 місяців тому +1

    Sir
    Equation samaj main Nehi aya.

  • @mohanmahi9217
    @mohanmahi9217 3 роки тому

    Sir pls tell me ,motor me winding resistance kitna hona chahiye

  • @shradhaaradhyacreations9050
    @shradhaaradhyacreations9050 2 роки тому

    Sir voltage cum honese current jyada hotahe to star connection me current Kam kyse hota he please explain

  • @vijendrayadav1771
    @vijendrayadav1771 3 роки тому

    ELR m settings kitne fault current level m rakhna chiye uski calculation

  • @sagargson9042
    @sagargson9042 3 роки тому

    Great 👏👏👏

  • @patelazhar1393
    @patelazhar1393 Рік тому

    3phase motor hai jo star delta me chalti hai usme ek phase jyada leti hai usme kya problem ho sakti hai .

  • @vijendrakaithal4049
    @vijendrakaithal4049 3 роки тому +1

    If I connect 415 volts instead of 230 volt to any load, then can I use formula V*I*1.732*pf for power calculation or I will use V*I*pf.
    Sir please clarify

  • @vinodbareth7541
    @vinodbareth7541 2 роки тому

    Sir vfd connect motar megger nahi le sakthe but why please explain

  • @vijendrayadav1771
    @vijendrayadav1771 3 роки тому +1

    ELR OR EFR CBCT K bare m video banwo sir

  • @PILLUDAS100
    @PILLUDAS100 7 місяців тому

    Sir less than 5 hp motor delta mai chalega kya agar usme 6 terminal hai

  • @kedarnathswain2540
    @kedarnathswain2540 3 роки тому

    Sir phase voltage means P to N
    But delta me nutral to nehi hai phase voltage kese malum kare ,only for Motor side explain plze

  • @noumankhan2197
    @noumankhan2197 3 роки тому

    Sir delta system mai thu phase voltage hota he nhi star mai phase voltage hota he kq delta mai neutral nhi hota

  • @RohitSharma-vb9jk
    @RohitSharma-vb9jk Рік тому

    Star ka rpm aur delta ka rpm kaise calculate karenge?

  • @sarveshkumarrai989
    @sarveshkumarrai989 Рік тому +1

    Sir,
    You mentioned that torque is directly proportional to current means if we change motor connection from delta to star, torque will more because star is consuming more current than delta????

    • @Ultimate_Avengers
      @Ultimate_Avengers 6 місяців тому

      Delta will take more current as compared to star

  • @manojkhilar4540
    @manojkhilar4540 3 роки тому

    If normal test 415 volt both in star after delta not star delta convert which one run speed

  • @saurabhdhokpande8048
    @saurabhdhokpande8048 3 роки тому

    Please showing RPM test of star and delta connected motor with tachometer. Thank you...

  • @suhailjamadar7267
    @suhailjamadar7267 Рік тому

    Hello sir my motor runs at star and automatically stops at delta and there is no Tripping motor tripping issue

  • @Krishna-rg7vw
    @Krishna-rg7vw 3 роки тому

    2KW jesi choti motor kyu star me hi chalate he??

  • @mbkelectricals6649
    @mbkelectricals6649 3 роки тому

    👍👍👍👍

  • @dhruvnai3880
    @dhruvnai3880 3 роки тому

    Sir you're saying Current is directly proportional to Torque so what about for the Slip ring induction motor, In slip ring induction motor, For increase the the torque we reduce the Current by Adding external resistance.

    • @electricalwithabhishekjoshi
      @electricalwithabhishekjoshi  3 роки тому

      Still we get high starting current peak with starting torque.

    • @dhruvnai3880
      @dhruvnai3880 3 роки тому +1

      @@electricalwithabhishekjoshi Dear Sir, Really I can't understand your answer, In case of slip ring induction motor.

  • @chandonkumar8418
    @chandonkumar8418 3 роки тому

    👌👌👌👌

  • @digitalcreator1793
    @digitalcreator1793 Рік тому

    😮😮❤❤❤❤

  • @shubhammhatre179
    @shubhammhatre179 3 роки тому

    👍👍👍👍👍👍✌