Isnt there a mistake in video, where you show neutral wire connected to the same side as current clamps? You meant N on the top left side I think. 10:02
Thank you. I was keen to see what the CSV would contain and there it was! I think I can work with that. Now feeling more confident to go ahead and get the 3EM.
This is interesting. The first point is installing the CTs, and the need to be careful which way round they are fitted. The only problem is that my manual shews them the opposite way round to those here, i.e. it shews a flow from the Grid K to the Load L. But in this video the Grid is L and Load is K. When I installed as shewn in my manual it gave nonsense readings, so I swapped them round. It's extraordinary that Shelly is sending out incorrect manuals. I note that in the video installation there is no breaker protection for the wiring to the Shelly. The black wires should be connected to, say, lighting MCBs, not direct to the 100A incomers. And thirdly the Shelly does not have an 'output', despite what the manual and this video says. It has a pair of no-volt relay contacts, so it switches any supply provided to it, but has no output of its own.
I’m using the exact same device in my house, my only problem was I had to move my router closer to the Shelly, WiFi reception wasn’t the best for the first attempt. It’s below my electric meter in a plastic enclosure, and WiFi reception is low to moderate with the router being 5 m away at the other side of a wall to the 3EM Great video and channel
Mine is in a metal box with the router in the same room (about 6m away). I was afraid that the metal box will completely shield the wifi, but it is still working, with OK signal strength.
A sajátomat én telepítettem. Nem kell hozzá villanyszerelő de ne most először szerelj villanyt. Az én Shellym a mérő után van. Amikor a hónap elején leolvasom a mérőt és Shelly és a végén újra mindkettőt, akkor a kettő között néhány kW különbség van. De könnyen lehet hogy kisebb fogyasztás esetén a hibahatár nagyobb.
Kedves Csongor, kérdésem a termékkel kapcsolatban, ha jól értelmezem nem a "valós" fogyasztást/visszatáplálást méri hanem a kettő összegét, ha ez "-" akkor fogyasztás, ha "+" akkor visszatáplálásként kerül rögzitésre. Tehát ha állandó egyenletes 1kW fogyasztásom lenne napi 24h-ban és 1kW megtermelt napenergia (ami éjszaka is termelne...) akkor a kettő eredője 0 lenne és ennyit is "mérne", nem 1kwh óra fogyasztás és 1kwh visszatáplálást jelezne három fázis esetén? Köszönöm elöre is.
Pontosan. Persze attól függ hol van a Shelly. Ha közvetlenül mérő után helyezi, akkor azt fogja látni hogy áramot fogyasztunk a hálózatról van áramot termelünk-e vissza. Azt nem tudjuk hogy a házon belül mennyi teremlődik vagy menni használódik el, csak hogy éppen azon a keresztmetszeten mennyi megy át az egyik irányba.
Az Over Power és az Under Power automatizációnál hány küszöbértéket lehet beállítani? Képes lenne a 3EM amperenként (6A-tól 16A-ig 11 lépcsőben vagy 6A-től 32A-ig 27 lépcsőben) vezérelni egy elektromos autó töltőt, hogy az autó töltése a lehető legpontosabban lekövesse a napelem inverter termelését?
Szia! Köszi a videot! Az lenne a kérdésem, hogy tudnál e olyan fogyasztásméröt ajánlani ami 3 fázist tudja és nem csak a kwh méri de a fogyasztás összegét forintban is mutatja. Nem baj ha nem wifis és nem hitelesített. Az egyik oldalon ahol árulják ezt a Shelly 3EM et ott azt is írták hogy áramdíj kalkuláció. Ezt szerettem volna megnézni, hogy ezt tènyleg tudja e és hogy mutatja. Erröl a videodban nem találtam semmit, ha csak nem voltam figyelmetlen. Elöre is köszi a választ! Lehet angolul is ha neked az a könnyebb.
Hello. Thank you very much for so useful video. Can you tell me please how long the wires are from currenters formers and, what do you think, would they work right if I will extend the wires? Thank you for answer in advance.
The wires are about half a meter. As far as I know the current clamp induces a small voltage in the voltage, hence it should be ok to extend with similar gauge wires. Test it with a load before and after to confirm it does not change the readings.
@@csongorvarga my unit is also not turning on but I had a problem initially with the neutral being cut by the rcd while the three phases remained connected. Do you think this could have damaged the device? I mistakenly connected the 3 phases from before the rcd and the neutral from after the rcd 😢
@@geraldh.8047 Very good question. I would assume that the unit taps on one of phase input and neutral to power itself, therefore I don't see why a not connected neutral would be an issue...
@@csongorvarga Thank you. Unfortunately I never powered the device on before mounting it in the cabinet and now it's dead after the rcd tripped due to my incorrect wiring. But perhaps it was dead from the start? Maybe I'll just try to RMA it and wait for them to refuse a replacement :-)
Рік тому
Hi Csongor Varga, If my installation have three phases as well as my inverter, will I need two Shelly 3EM, right?
Can I use the 3em to monitor the 2-incoming phases (in US) and the 3rd or N leg to monitor another 120 or 220 circuit? So I'd have "overall" and "something interesting" for 2 monitoring sensors in Home Assistant?
This is designed to operate a contactor that you can turn on/off with the 3EM. It depends on how you install that contactor to be in front of, or behind the Shelly.
Is it possible to read the amount of kwh used between for instance 16:00h on day x and 10:00h on day y? It's to measure the energy consumption fo the guests in our holidayhouse during their stay.
Szia Csongor! 😀 Teszik a videó és a termék is. Ami kérdésem lenne, hogy a lakásomban van 3 elektromos padlófűtés illete egy infrapanelom a hálószobában. Külön megszakítokon. Ezzel az eszközzel tudnám mérni a fogyasztásukat? Illetve ez a zúgó hang az eszközből jön? Köszönöm a válaszod előre is Üdv Árpi
Szia, igen ezzel tudnád mérni. Csak rá kell pattintani az árammérőt a kábelre a megszakító után. A szekrényben volt még egy 24V-os tápegység egy másik gépnek, annak van zúgó hangja. A Shelly teljesen csöndes.
@@csongorvarga köszönöm a választ. 😀 Bár most hogy kicsit jobban körülnéztem, a shelly 4pm jobb válsztásnak tűnik. Olcsobb és 4 dolgot is tudok vele mérni. Mit gondolsz?
@@1987Redfield Ez még nem volt nálam, de biztos tudja ezeket. Ezt ugye csak villamos szekrényben tudod beépíteni és át kell rajta vezetni a kábeleket, szóval talán több időbe telik a beüzemelése, de biztos hogy egy nagyon korrekt megoldás lesz a végén, nem az a kábel rengeteg ami nálam van. Ez ugye csak 16A-ig tud mérni, de az neked elég lesz. És pulsz funckióként kapcsolóként is használhatod!
Hello, thanks for this great video, it convinced me of the fact that this is the energy meter I need. Although I have 1 question, do you know if the returned energy(of the solar panels) is the real energy the solar panels returns or is it the returned energy minus the energy you are consuming at the moment? So for example, returned energy is 2kw but I use 1kw while the sun is shining. Will it show 2kw of returned energy or only 1kw as I used 1kw in the meantime. Thanks a lot.
Easy answer, it should measure 1KW because the 1KW you produce, is used and will not pass the lines out of the house. So you should use another one for the "production" lines so you can calculate the difference or "what you save".
I have a 3 phase supply, but want to use a Shelly EM (not 3EM) with 2 CT clamps to monitor two meters on different phases, and it's powered from a different phase to one of the meters. I have noticed I get some negative power readings. Also I get positive power readings sometimes, so I don't think the CT clamp is facing the wrong way. Any ideas?
There is an arrow on the CT clamp to show the direction of the positive current flow. But if you only get some negative readings and in general it is positive, it is placed correctly. But I cannot explain why you get some negative readings. I can't think of any home appliance that would feed energy back even for a short period. Maybe check the connections to make sure all are OK.
Thank you very much for your video. I have a 3 phase grid supply and my Solar inverter is only 1 phase system ? The main house is connected on Phase2. Can i get the consumption if i use the 3 clamps or should i use the 1 phase + separate solar power diagram?
It depends what you want to see. If you put the 3 clamps on the 3 phase after your meter, you will see if you generate more power than what your houses uses on that phase. It will go negative. On the other 2 phases it will always be positive.
Are you sure your installation is right (safe) ? In the diagram you can see that you should connect the power to the Shelly behind a breaker and as I can see in your installation you connected it directly to the three phases (through the junction though which i assume doesn't provide any protection).
@@csongorvarga Thanks for the replay. I'm trying to understand the correct wiring for a 3 phase installation, Please let me know if I'm right that the A,B,C clamps should be each on a different phase and the VA, VB, VC should be connected to a phase breaker that is connected to the same phases that the clamps are on (i.e. if Clamp A in on the brown cable phase then the VA port should be connected to a phase breaker that is connected to the brown phase), is that right ?
@@PatientZiro Yes that is correct. The current clamp senses current and the VA, VB, VC connections are used to measure the voltage on the phases. If you mix them the power calculation will not be accurate, as the voltage on the different phases can be different.
@@csongorvarga VA, VB, VC need to be connected to a breaker with current capacity is the Clamps? My house has 3X40 Amps installation, so I need to supply the VA,VB,VC the same current as well? or I can go with 10A breaker?
This appears like a very nice product. It is unfortunate however that it doesn't include a USB connection for a laptop. That would allow one to use it in situations where WIFI is not available, like out in a power shed for solar.
If you need that, probably the best option is a modbus RTU energy meter. It only needs an inexpensive USB to RS485 cable and you can read the values over serial. And RS485 supports up to 500m cable length.
Hello, can I use Shelly 3 EM for measuring consumption on all 3 phases in home and electricity generation from my 1phase solar plant in same time? thank you
Yes, I had the same setup initially. It shows the 3 phases separately in the app, and you will notice that the phase with the solar panel will go negative (more solar than usage), but the other two phases will just stay in positive all the time.
There is a Shelly EM which has only 2 inputs. That is somewhat cheaper so you can use that as well. Or use the 3 inputs on the 3EM to measure different points in your network. For example if possible you can measure the solar generation and the consumption separately.
Hi Csongor! In older youtube videos (like 1 year old) I saw that Shelly 3EM was measuring reactive power as well on it's webserver. But as I can see in your video, it has been exchanged with the current values. I think this happend after a certain FW update. Could you please confirm that it's still possible to get reactive power/energy or not?! Many thanks.
To be honest, I don't remember if it measured reactive power or not. But the current firmware only states "power", but there is also "power factor". So you could calculate reactive power?
Shelly stopped their older models, so there is a new "Pro" model from almost everything. I would say that probably it is the same. There are a lot small differences for Pro models (like cloud and local connection works at the same time), and most probably how they communicate over MQTT is different.
Hi, can I get consumption per user when I add different users? I am looking for a solution to split the electricity usage bill in a common public area to its users. Can this product do that? If you help me I will be so happy.
If you want that, I suggest that you purchase separate meters for each area. There is a Shelly EM which only measures one phase. You can put them into separate rooms in the Shelly app and it will show consumption per rooms. Shelly 3EM is really designed for 3 phase, and it by default add the consumption up on the 3 phases. But when you export the data to CSV you can separate out the measurements.
@@csongorvargaFirst of all, thank you very much for your feedback. I guess I didn't express my need clearly. Our multi-storey building has a auto parking, and there are common charging sockets and car charging stations in the autopark. Normally, the bill that came as a result of electricity consumption such as lighting in the parking lot was paid jointly by the building. But now electric cars have become commonplace and they need charging. But not every occupant of the building has an electric vehicle, some have more than one electric vehicle. So I'm looking for a way to divide the electricity by the usage amount to the users. Since there are too many flats, occopants it does not seem possible to separate the phases of the building for each flat, to use a measuring device for each and to use a separate electrical outlet for each, both in terms of cost and appearance. Instead, I am looking for a system where the electricity output is active by account and the electricity usage of the each user is measured. For example when an user login system, he can open electric switch then system can add electric usage of him. When he log from system electric will gone.
I have a 3-phase grid supply and my Solar inverter is also for a 3 phase system ? how do you connect shelly EM here, do I buy 2 Shelly 3M's, one for production and one for consumption ?
Just install it behind your main breaker (not after the inverter). In that case it will measure the gross input/output of your house. If it shows generation it means your solar is generating more than what you consume in the house. If it shows consumption your solar is either not running, or you use more electricity than consumed.
@@csongorvarga But this way I wont be able to get how much was my consumption, as it will only measure what the grid is giving us as consumption or what grid is being given back.
@@cyxgoku In this case you probably need 2 Shelly units. One will be connected directly after the inverter. That will measure your production. The second could be tricky: you need to find the cables after the inverter connection that goes to all your circuits in the house. If you can find that you can measure all your consumption there. But for example my inverter in on the second floor inside my house, so I cannot separate out all my consumables. In that case you measure your entire house, and you have to calculate the difference manually in Excel from the CSV export data of the two Shelly.
Be kellene üzemelnem egyet, ha minden igaz már mér mert ha belépek látok mért értékeket, a videódban látok pillanatnyi fogyasztási értékeket, azt hol lehet elérni
Az aplikációban minuszos értékem van 2 fázison egyen meg pozitív, van napelem, de szerintem akkora termelés nincs hogy kifele menjen a hálózat írányába.
Isnt there a mistake in video, where you show neutral wire connected to the same side as current clamps?
You meant N on the top left side I think.
10:02
Yes you are right. According to this diagram, you connect the neutral to the N terminal on the upper left, just above VA, VB and VC.
Thank you. I was keen to see what the CSV would contain and there it was! I think I can work with that. Now feeling more confident to go ahead and get the 3EM.
Köszi a videót!
This is interesting. The first point is installing the CTs, and the need to be careful which way round they are fitted. The only problem is that my manual shews them the opposite way round to those here, i.e. it shews a flow from the Grid K to the Load L. But in this video the Grid is L and Load is K. When I installed as shewn in my manual it gave nonsense readings, so I swapped them round. It's extraordinary that Shelly is sending out incorrect manuals. I note that in the video installation there is no breaker protection for the wiring to the Shelly. The black wires should be connected to, say, lighting MCBs, not direct to the 100A incomers. And thirdly the Shelly does not have an 'output', despite what the manual and this video says. It has a pair of no-volt relay contacts, so it switches any supply provided to it, but has no output of its own.
In my shelly 3EM instruction "L" is for the house and "K" is for the line. Also, the arrow is in the opposite direction?? WITH?
Thank you for putting so much work into this video. Lots of great info!!
Great video thanks.
Is it possible to rename the labels ?
i.e. "Phase B" to "Cooker" ?
I’m using the exact same device in my house, my only problem was I had to move my router closer to the Shelly, WiFi reception wasn’t the best for the first attempt. It’s below my electric meter in a plastic enclosure, and WiFi reception is low to moderate with the router being 5 m away at the other side of a wall to the 3EM
Great video and channel
Mine is in a metal box with the router in the same room (about 6m away). I was afraid that the metal box will completely shield the wifi, but it is still working, with OK signal strength.
Szia, két kérdés. Ezt én tudom-e installálni, vagy villanyszerelő kell hozzá, illetve mennyire pontos. Köszi.
A sajátomat én telepítettem. Nem kell hozzá villanyszerelő de ne most először szerelj villanyt. Az én Shellym a mérő után van. Amikor a hónap elején leolvasom a mérőt és Shelly és a végén újra mindkettőt, akkor a kettő között néhány kW különbség van. De könnyen lehet hogy kisebb fogyasztás esetén a hibahatár nagyobb.
Kedves Csongor,
kérdésem a termékkel kapcsolatban, ha jól értelmezem nem a "valós" fogyasztást/visszatáplálást méri hanem a kettő összegét, ha ez "-" akkor fogyasztás, ha "+" akkor visszatáplálásként kerül rögzitésre.
Tehát ha állandó egyenletes 1kW fogyasztásom lenne napi 24h-ban és 1kW megtermelt napenergia (ami éjszaka is termelne...) akkor a kettő eredője 0 lenne és ennyit is "mérne", nem 1kwh óra fogyasztás és 1kwh visszatáplálást jelezne három fázis esetén?
Köszönöm elöre is.
Pontosan. Persze attól függ hol van a Shelly. Ha közvetlenül mérő után helyezi, akkor azt fogja látni hogy áramot fogyasztunk a hálózatról van áramot termelünk-e vissza. Azt nem tudjuk hogy a házon belül mennyi teremlődik vagy menni használódik el, csak hogy éppen azon a keresztmetszeten mennyi megy át az egyik irányba.
Az Over Power és az Under Power automatizációnál hány küszöbértéket lehet beállítani? Képes lenne a 3EM amperenként (6A-tól 16A-ig 11 lépcsőben vagy 6A-től 32A-ig 27 lépcsőben) vezérelni egy elektromos autó töltőt, hogy az autó töltése a lehető legpontosabban lekövesse a napelem inverter termelését?
Szia! Köszi a videot! Az lenne a kérdésem, hogy tudnál e olyan fogyasztásméröt ajánlani ami 3 fázist tudja és nem csak a kwh méri de a fogyasztás összegét forintban is mutatja. Nem baj ha nem wifis és nem hitelesített. Az egyik oldalon ahol árulják ezt a Shelly 3EM et ott azt is írták hogy áramdíj kalkuláció. Ezt szerettem volna megnézni, hogy ezt tènyleg tudja e és hogy mutatja. Erröl a videodban nem találtam semmit, ha csak nem voltam figyelmetlen. Elöre is köszi a választ! Lehet angolul is ha neked az a könnyebb.
Hello. Thank you very much for so useful video.
Can you tell me please how long the wires are from currenters formers and, what do you think, would they work right if I will extend the wires?
Thank you for answer in advance.
The wires are about half a meter. As far as I know the current clamp induces a small voltage in the voltage, hence it should be ok to extend with similar gauge wires. Test it with a load before and after to confirm it does not change the readings.
@@csongorvarga thank you 👍
Hi, when you connect the 3 phase and neutral will the LED go on? I just installed, connected all but LED is off and no AP is created
Uh, I dont remember any more, but the led is on when it is working. I think your unit is not getting power or it is broken.
@@csongorvarga my unit is also not turning on but I had a problem initially with the neutral being cut by the rcd while the three phases remained connected. Do you think this could have damaged the device? I mistakenly connected the 3 phases from before the rcd and the neutral from after the rcd 😢
@@geraldh.8047 Very good question. I would assume that the unit taps on one of phase input and neutral to power itself, therefore I don't see why a not connected neutral would be an issue...
@@csongorvarga Thank you. Unfortunately I never powered the device on before mounting it in the cabinet and now it's dead after the rcd tripped due to my incorrect wiring. But perhaps it was dead from the start? Maybe I'll just try to RMA it and wait for them to refuse a replacement :-)
Hi Csongor Varga,
If my installation have three phases as well as my inverter, will I need two Shelly 3EM, right?
Yes, you should monitor all 3 phases.
Can I use the 3em to monitor the 2-incoming phases (in US) and the 3rd or N leg to monitor another 120 or 220 circuit? So I'd have "overall" and "something interesting" for 2 monitoring sensors in Home Assistant?
If you also use it as a smart switch for some specific point, does it also measure the specific consumption that it switches on and off?
This is designed to operate a contactor that you can turn on/off with the 3EM. It depends on how you install that contactor to be in front of, or behind the Shelly.
Is it possible to read the amount of kwh used between for instance 16:00h on day x and 10:00h on day y? It's to measure the energy consumption fo the guests in our holidayhouse during their stay.
Szia Csongor! 😀
Teszik a videó és a termék is. Ami kérdésem lenne, hogy a lakásomban van 3 elektromos padlófűtés illete egy infrapanelom a hálószobában. Külön megszakítokon. Ezzel az eszközzel tudnám mérni a fogyasztásukat?
Illetve ez a zúgó hang az eszközből jön?
Köszönöm a válaszod előre is
Üdv Árpi
Szia, igen ezzel tudnád mérni. Csak rá kell pattintani az árammérőt a kábelre a megszakító után. A szekrényben volt még egy 24V-os tápegység egy másik gépnek, annak van zúgó hangja. A Shelly teljesen csöndes.
@@csongorvarga köszönöm a választ. 😀
Bár most hogy kicsit jobban körülnéztem, a shelly 4pm jobb válsztásnak tűnik.
Olcsobb és 4 dolgot is tudok vele mérni.
Mit gondolsz?
@@1987Redfield Ez még nem volt nálam, de biztos tudja ezeket. Ezt ugye csak villamos szekrényben tudod beépíteni és át kell rajta vezetni a kábeleket, szóval talán több időbe telik a beüzemelése, de biztos hogy egy nagyon korrekt megoldás lesz a végén, nem az a kábel rengeteg ami nálam van. Ez ugye csak 16A-ig tud mérni, de az neked elég lesz. És pulsz funckióként kapcsolóként is használhatod!
It can measure DC from a panels strings? Each string has near 210v DC and I have three equal strings. 6 x 410w panels) x 3 strings. Thanks
No, these current clamps can only measure AC.
Hello, thanks for this great video, it convinced me of the fact that this is the energy meter I need. Although I have 1 question, do you know if the returned energy(of the solar panels) is the real energy the solar panels returns or is it the returned energy minus the energy you are consuming at the moment? So for example, returned energy is 2kw but I use 1kw while the sun is shining. Will it show 2kw of returned energy or only 1kw as I used 1kw in the meantime. Thanks a lot.
Easy answer, it should measure 1KW because the 1KW you produce, is used and will not pass the lines out of the house. So you should use another one for the "production" lines so you can calculate the difference or "what you save".
I have a 3 phase supply, but want to use a Shelly EM (not 3EM) with 2 CT clamps to monitor two meters on different phases, and it's powered from a different phase to one of the meters. I have noticed I get some negative power readings. Also I get positive power readings sometimes, so I don't think the CT clamp is facing the wrong way. Any ideas?
There is an arrow on the CT clamp to show the direction of the positive current flow. But if you only get some negative readings and in general it is positive, it is placed correctly. But I cannot explain why you get some negative readings. I can't think of any home appliance that would feed energy back even for a short period. Maybe check the connections to make sure all are OK.
Thank you very much for your video. I have a 3 phase grid supply and my Solar inverter is only 1 phase system ? The main house is connected on Phase2. Can i get the consumption if i use the 3 clamps or should i use the 1 phase + separate solar power diagram?
It depends what you want to see. If you put the 3 clamps on the 3 phase after your meter, you will see if you generate more power than what your houses uses on that phase. It will go negative. On the other 2 phases it will always be positive.
Hi, is it possible to monitor 400V triphase circuit (1 clamp on each phase). and power supplying the 3EM by phase and neutral? thanks
Sorry, but no. I checked the Shelly 3 EM and also the Shelly Pro 3 EM and both of them only go up-to 230V AC.
Are you sure your installation is right (safe) ?
In the diagram you can see that you should connect the power to the Shelly behind a breaker and as I can see in your installation you connected it directly to the three phases (through the junction though which i assume doesn't provide any protection).
Yes, you are correct. I have my meter with the main breaker for the entire house outside in a separate cabinet. This is why I did it like this here.
@@csongorvarga Thanks for the replay.
I'm trying to understand the correct wiring for a 3 phase installation, Please let me know if I'm right that the A,B,C clamps should be each on a different phase and the VA, VB, VC should be connected to a phase breaker that is connected to the same phases that the clamps are on (i.e. if Clamp A in on the brown cable phase then the VA port should be connected to a phase breaker that is connected to the brown phase), is that right ?
@@PatientZiro Yes that is correct. The current clamp senses current and the VA, VB, VC connections are used to measure the voltage on the phases. If you mix them the power calculation will not be accurate, as the voltage on the different phases can be different.
@@csongorvarga VA, VB, VC need to be connected to a breaker with current capacity is the Clamps?
My house has 3X40 Amps installation, so I need to supply the VA,VB,VC the same current as well? or I can go with 10A breaker?
@@csongorvarga But the breaker for the entire house won't be the correct capacity to protect the Shelly wiring. 6A max I'd say.
I've got suspicion that shelly lied about neutral wire transformer functionality. I cannot see amps on the neutral wire in app or web interface.
This appears like a very nice product. It is unfortunate however that it doesn't include a USB connection for a laptop. That would allow one to use it in situations where WIFI is not available, like out in a power shed for solar.
If you need that, probably the best option is a modbus RTU energy meter. It only needs an inexpensive USB to RS485 cable and you can read the values over serial. And RS485 supports up to 500m cable length.
Hello, can I use Shelly 3 EM for measuring consumption on all 3 phases in home and electricity generation from my 1phase solar plant in same time? thank you
Yes, I had the same setup initially. It shows the 3 phases separately in the app, and you will notice that the phase with the solar panel will go negative (more solar than usage), but the other two phases will just stay in positive all the time.
i just bought this same one. as a FYI... There is no Phase N transformer available, even if you want to pay for it separately.
I bought N transformer but I cannot see any stats about N phase? Am I blind?
I have two solar system and two houses both houses single phase.
Do I need to Shelly 3 e.m. ?
There is a Shelly EM which has only 2 inputs. That is somewhat cheaper so you can use that as well. Or use the 3 inputs on the 3EM to measure different points in your network. For example if possible you can measure the solar generation and the consumption separately.
Hi Csongor! In older youtube videos (like 1 year old) I saw that Shelly 3EM was measuring reactive power as well on it's webserver. But as I can see in your video, it has been exchanged with the current values. I think this happend after a certain FW update. Could you please confirm that it's still possible to get reactive power/energy or not?! Many thanks.
To be honest, I don't remember if it measured reactive power or not. But the current firmware only states "power", but there is also "power factor". So you could calculate reactive power?
que diferencia tiene con este modelo Shelly Pro 3EM - 120A Contador trifásico
Shelly stopped their older models, so there is a new "Pro" model from almost everything. I would say that probably it is the same. There are a lot small differences for Pro models (like cloud and local connection works at the same time), and most probably how they communicate over MQTT is different.
Hi, can I get consumption per user when I add different users? I am looking for a solution to split the electricity usage bill in a common public area to its users. Can this product do that? If you help me I will be so happy.
If you want that, I suggest that you purchase separate meters for each area. There is a Shelly EM which only measures one phase. You can put them into separate rooms in the Shelly app and it will show consumption per rooms. Shelly 3EM is really designed for 3 phase, and it by default add the consumption up on the 3 phases. But when you export the data to CSV you can separate out the measurements.
@@csongorvargaFirst of all, thank you very much for your feedback. I guess I didn't express my need clearly. Our multi-storey building has a auto parking, and there are common charging sockets and car charging stations in the autopark. Normally, the bill that came as a result of electricity consumption such as lighting in the parking lot was paid jointly by the building. But now electric cars have become commonplace and they need charging. But not every occupant of the building has an electric vehicle, some have more than one electric vehicle. So I'm looking for a way to divide the electricity by the usage amount to the users. Since there are too many flats, occopants it does not seem possible to separate the phases of the building for each flat, to use a measuring device for each and to use a separate electrical outlet for each, both in terms of cost and appearance. Instead, I am looking for a system where the electricity output is active by account and the electricity usage of the each user is measured. For example when an user login system, he can open electric switch then system can add electric usage of him. When he log from system electric will gone.
I have a 3-phase grid supply and my Solar inverter is also for a 3 phase system ? how do you connect shelly EM here, do I buy 2 Shelly 3M's, one for production and one for consumption ?
Just install it behind your main breaker (not after the inverter). In that case it will measure the gross input/output of your house. If it shows generation it means your solar is generating more than what you consume in the house. If it shows consumption your solar is either not running, or you use more electricity than consumed.
@@csongorvarga But this way I wont be able to get how much was my consumption, as it will only measure what the grid is giving us as consumption or what grid is being given back.
@@cyxgoku OK, so the question is, what do you want to measure?
@@csongorvarga My Consumption and my production.
@@cyxgoku In this case you probably need 2 Shelly units. One will be connected directly after the inverter. That will measure your production. The second could be tricky: you need to find the cables after the inverter connection that goes to all your circuits in the house. If you can find that you can measure all your consumption there. But for example my inverter in on the second floor inside my house, so I cannot separate out all my consumables. In that case you measure your entire house, and you have to calculate the difference manually in Excel from the CSV export data of the two Shelly.
Szia!!! Magyar nyelvű videód nincs véletlenül ebben a témában???
Szia, nincsen. Mármint a Shelly 3EM-mel kapcsolatban?
Be kellene üzemelnem egyet, ha minden igaz már mér mert ha belépek látok mért értékeket, a videódban látok pillanatnyi fogyasztási értékeket, azt hol lehet elérni
Ami nálam különböző az az áramváltón a jelzés, a papírja azt írja K a hálózati oldal, a nyíl az L felé mutat ami a ház. Ez a videódban fordítva van
Az aplikációban minuszos értékem van 2 fázison egyen meg pozitív, van napelem, de szerintem akkora termelés nincs hogy kifele menjen a hálózat írányába.
Valamint az eszköz magától offline állapotba kerül....
Did you ever figure out how to export the CSV file? (Load profile)
Yes, you need to visit the built in website of the 3EM and you find the download button there.
@@csongorvarga Thanks for the info!
i strangly get - readings, - 2.5KW. instead of plus
Turn the current clamp around.
@@csongorvarga thanks wil do
Hello! Nem lehetne magyarul ?
Mindent lehet, csak nincs annyi időm.
@@csongorvarga Köszi!