Budget Friendly 24V Solar System: 2.4kW Inverter, 2kW Solar Array, MPPT and 60A Charger $1500

Поділитися
Вставка
  • Опубліковано 6 лис 2024

КОМЕНТАРІ • 1 тис.

  • @WillProwse
    @WillProwse  4 роки тому +112

    Corrections:
    -Leg should be "line". Or live, or hot. Line is probably best term here in America. I have a huge book I've been reading on inverter circuit design and it always calls the hot leads, "leg".
    -Total cost is $1100 plus $400 for shipping. So $1500 total, oops I totally forgot about the shipping cost of the byd pack. It's $300! But it's flat rate. That increases the price substantially unless you buy multiple packs or do a local pick up. And inverter is $100 to ship. Still dirt cheap.
    -circuit breaker is rated for 120 amps. Run inverter to the max!
    I think that's all I missed. Thanks to everyone pointing this stuff out. I try to mention everything as fast as possible, but can be difficult.
    ~~~~~~~~~~~~~~~~~~~~~~~~~~~
    Does off-grid solar confuse you? Check out my DIY friendly website for solar system packages and product recommendations, and so much more! www.mobile-solarpower.com
    Join our DIY solar community! #1 largest solar forum on the internet for beginners and professionals alike: www.diysolarforum.com
    Check out my best-selling, beginner-friendly 12V off-grid solar book (affiliate link):
    amzn.to/2Aj4dX4
    If DIY is not for you, but you love solar and need an offgrid system, check out Tesla Solar. Low prices and great warranty, and they can take your entire house offgrid with their new Powerwalls: ts.la/william57509
    ~~~~~~~~~~~~~~~~~~~~~~~~~
    My solar equipment recommendations (Constantly updated! Check here first):
    12V/48V Lithium Batteries: www.mobile-solarpower.com/solar-batteries.html
    Solar System Component Directory: www.mobile-solarpower.com/solarcomponents.html
    Plug-N-Play Systems: www.mobile-solarpower.com/full-size-systems.html
    Complete 48V System Kits: www.mobile-solarpower.com/complete-48v-solar-kits.html
    DIY Friendly Air Conditioner/ Heat Pumps: www.mobile-solarpower.com/solar-friendly-air-conditioners.html
    Complete 48V System Blueprint: www.mobile-solarpower.com/48v-complete-system-blueprint.html
    ~~~~~~~~~~~~~~~~~~~~~~~~~~
    My Favorite Online Stores for DIY Solar and Coupon Codes:
    -Current Connected: SOK, Victron and High Quality Components. Best prices and warranty around: currentconnected.com/?ref=wp
    -Signature Solar: Cheap Server Rack Batteries and Large Solar Panels:
    www.signaturesolar.com/?ref=h-cvbzfahsek
    -Ecoflow Delta Official Site: My favorite plug-n-play solar generator:
    us.ecoflow.com/?aff=7
    -AmpereTime: Cheapest 12V batteries around:
    amperetime.com/products/ampere-time-12v-100ah-lithium-lifepo4-battery?ref=h-cvbzfahsek
    -Rich Solar: Mega site and cheaper prices than renogy! Check them out:
    richsolar.com/?ref=h-cvbzfahsek
    -Shop Solar Kits: Huge site with every solar kit you can imagine! Check it out:
    shopsolarkits.com/?ref=will-p
    -Battery Hookup: Cheap cell deals
    bit.ly/2mIxSqt
    10% off code: diysolar
    -Watts 24/7: Best deals on all-in-one solar power systems, with customer support and distribution here in the USA:
    watts247.com/?wpam_id=3
    ~~~~~~~~~~~~~~~~~~~~~~~~~~~
    Contact Information:
    I am NOT available for personal solar system consult! If you wish to contact me, this is my direct email: williamprowsediysolar@gmail.com
    Join the forum at diysolarforum.com/ if you wish to hang out with myself and others and talk about solar
    FTC Disclosure Statement and Disclaimers:
    Every video includes some form of paid promotion or sponsorship. Some links on this youtube channel may be affiliate links. We may get paid if you buy something or take an action after clicking one of these. My videos are for educational purposes only. Information is subject to change/update at any time. Electricity is DANGEROUS and can kill. Be smart and use common sense :)
    DIY Solar Power with Will Prowse is a participant in the Amazon Services LLC Associates Program,
    An affiliate advertising program designed to provide a means for sites to earn advertising fees by advertising and linking to Amazon.com

    • @Larryn7luf
      @Larryn7luf 4 роки тому +1

      Not sure the cost has gone up, but the shipping I am seeing is $350.00 and $99.00 for the PIP2424LV-MSD. Also tax to be added too. Yes it is cheap for what you get and leave me in the I just do not know what I want and need. This started as I need back up power for 2 CPAP's for 3 or 4 days. I believe there maybe a discount that maybe used.

    • @WillProwse
      @WillProwse  4 роки тому +5

      Oh get the free shipping lv2424. There are two ads on eBay.

    • @Larryn7luf
      @Larryn7luf 4 роки тому

      @@WillProwse I am not finding the free shipping, sorry.

    • @WillProwse
      @WillProwse  4 роки тому +4

      Its out of stock, the only one available is the more expensive one. That's why. One in video is cheaper model

    • @WillProwse
      @WillProwse  4 роки тому +3

      @@Larryn7luf green one costs more. White one is cheaper model.

  • @offgridphilosophy7959
    @offgridphilosophy7959 4 роки тому +21

    I worked for a power company in Florida back in the day and someone did a diy grid tie system with a generator. One of the storm duty crew employees was killed by the back current in a downed power line. Thanks for pointing out that you need to do grid ties right Will!

    • @zarbonida
      @zarbonida 4 роки тому +2

      Very bad things!
      R.i.p

    • @offgridphilosophy7959
      @offgridphilosophy7959 4 роки тому +2

      @@marsBeBelinda The voltage went into the transformer backwards and pumped voltage upto 7,620 volts.

    • @offgridphilosophy7959
      @offgridphilosophy7959 4 роки тому +1

      @@marsBeBelinda A hurricane hit abd this guy hooked up his generator to his house. It backfed into the pole transformer in reverse direction and then was brought up to 7,620 volts and killed a man.

    • @offgridphilosophy7959
      @offgridphilosophy7959 4 роки тому +1

      @@marsBeBelinda Please, no more word salads.

    • @offgridphilosophy7959
      @offgridphilosophy7959 4 роки тому

      @@marsBeBelinda Are you using voice to text?

  • @a.w.thompson4001
    @a.w.thompson4001 4 роки тому +45

    You just gave us a video for the very system I'm building! Bought the green MPP Solar 24v unit after your first all-in-one review (though not backfeeding) and am about to buy the battery module which I was interested in because the "raw" used BYD cells had difficult technical challenges and I'm a newbie. You're the best, Will. THANK YOU for making us wiser and greener!!!

    • @omarsuarez7166
      @omarsuarez7166 4 роки тому +1

      Hi Thompson, How is your system coming along? I would like to build the same thing, MPP Solar 24v unit . Did you have any trouble with programing the settings?

    • @thomaswatson1844
      @thomaswatson1844 4 роки тому +1

      Hi there. I have the 24v version, but the fan is so loud. Do you have the same issue? Cheers

    • @dnhman
      @dnhman 4 роки тому +2

      Do you have two battery banks? I saw a note from Will that two are needed? How would they be wired? P orS?

    • @sNEAKYnIGHTmUPPET
      @sNEAKYnIGHTmUPPET 4 роки тому +1

      dnhman parallel to supply more amps. Keep the wires as close in length as possible :)

  • @morkovija
    @morkovija 4 роки тому +48

    Prices are dropping before our eyes. This is amazing! At least we have something going in the right direction

  • @jameshathaway5117
    @jameshathaway5117 4 роки тому +3

    Just wanted to let everyone know if you use this charge controller you can't set the low voltage cut off like he shows in this video. You have to set the battery type to "user defined" before you can change the cutout voltage. Thanks for the walk through will. It really helped me set up my system.

    • @WillProwse
      @WillProwse  4 роки тому

      Yes you can't set absorption or float either. I figure people will have it set to user anyways

  • @drymoonproperties
    @drymoonproperties 4 роки тому +6

    I am learning so much from you! I am very thankful we don't have the money to pay someone to install a system for us that doesn't change the need for solar backup as well as prepare for the inevitable need of being put on oxygen before I pass away being I have a terminal lung disease that cannot be cured.
    I am going to install a small system independent of the grid to run a couple of TV's, refrigerator and oxygen machine plus a few lights. The big stuff runs on LP gas so very little need for anything gas operated with the exception of lighting burners and running fans on the furnace and one 6600BTU window unit air conditioner.

    • @alarmsquadnj
      @alarmsquadnj 4 роки тому

      Good idea I was thinking the same thing I have copd

  • @kennethvessels3585
    @kennethvessels3585 3 роки тому +5

    Omg this totally saved me tons of money running power inside my ManCave along with my storm shelter/ bunker! Great video pal!

    • @wendygerrish4964
      @wendygerrish4964 3 роки тому

      Oh..this is the answer to storm shelter bunkers.

  • @radiotaccommunications1343
    @radiotaccommunications1343 4 роки тому +29

    This is exactly what I will do for ,my house build only in 48 volts. Thanks Will...👮‍♂️

    • @williamh.2982
      @williamh.2982 3 роки тому

      How do you make this 48v ? I know nothing about solar. Thank you

    • @Dmpddiver
      @Dmpddiver 3 роки тому +3

      You place these batteries in series, 24+24=48 great batteries for solar storage.

    • @williamh.2982
      @williamh.2982 3 роки тому +5

      @@Dmpddiver Thank You Mr. Tindol I'm on oxygen so I need a stand by source. Last time a hurricane hit I was out of power 4 days, I had to drive 78 miles to get gas for my generator... Again Thank You

  • @pivotas4406
    @pivotas4406 4 роки тому +14

    Non UL listed equipment in an off-grid / no grid tie situation may work in some counties but not in others. You should be able check on-line for the requirements or call the permitting office. Another consideration is if you carry home owners insurance how this would effect your policy. A fire caused by non-UL solar systems, particularly DIY power walls, could provide the insurer an excuse to not honor the policy.

    • @WillProwse
      @WillProwse  4 роки тому +4

      Yep absolutely

    • @geraldhenrickson7472
      @geraldhenrickson7472 4 роки тому +4

      If an insurance provider wants an excuse to not cover damages...they will find a way. All electrical related items are to be installed by a licensed and bonded professional so any home-owner installation is a popular reason for claim denial. The UBC (Universal Building Code) is so complex that its fine print can also be used to deny any claim. Might as well press ahead yet do your research for a good install. Besides...some of us actually live on wheels. We be rebels, we disdain insurance...mostly sorta anyways.

    • @mr.hostility8970
      @mr.hostility8970 4 роки тому +5

      No. Just no. Independence is worth the cost of defiance. Permit, tax and regulate till you strip away all freedoms.

    • @rootcanal7188
      @rootcanal7188 4 роки тому

      I notice that the Ecoflow Delta portable power station is UL listed, but the Bluetti isn't. I emailed Bluetti to ask about that, and the fellow that wrote back didn't know what I was talking about LOL

    • @bernardcharlesworth9860
      @bernardcharlesworth9860 2 місяці тому

      They can be line man killers

  • @abiolaadeola1937
    @abiolaadeola1937 3 роки тому

    Thank Will, you are the BEST, among the REST.
    Your HONESTY was what drawn me, to your channel, and now, I'm HOOKED.

  • @BradIXXI
    @BradIXXI 4 роки тому +4

    Dude!! I freeking love your videos. I am learning so much from you I feel guilty.... Keep up the good work, it is very apparent that you love what you do.

  • @DesertDogJournal
    @DesertDogJournal 3 роки тому +2

    I’m really enjoying your videos. Have been looking at the commercial solar generators on the market and thanks to your content it looks like I’m better off building my own system.

  • @P_RO_
    @P_RO_ 4 роки тому +14

    Will, if this got any simpler the system would install itself. Great vid!

    • @jingtan68
      @jingtan68 4 роки тому

      Where can I buy those inverter ⋯? Please let me know

  • @dabbydoodle4801
    @dabbydoodle4801 4 роки тому +3

    I talked to an Old Order Amish who said ALWAYS install a Lightening Resister. He learned the hard way. Burnt his building down, costing thousands!!! Can you show us how to install one in this system PLEASE!!!

    • @kevingee4294
      @kevingee4294 4 роки тому

      The EMP shield protects against lightning, powers surge, EMP, solar flare ECT... There are several types to choose from.

  • @shaymcquaid
    @shaymcquaid 4 роки тому +3

    Ordered this all in one jammy yesterday. Thanks Will! My bus is gonna' rock!

    • @WillProwse
      @WillProwse  4 роки тому +2

      I used lv2424 in my RV for months. You will love it. Super powerful

    • @strikerhitter
      @strikerhitter 4 роки тому

      Where did you purchase your inverter from? I see multiple people sell them on ebay. I want to avoid getting ripped off by a fake inverter or reseller. Any help will be appreciated.

    • @lindanazario6770
      @lindanazario6770 4 роки тому

      What website

  • @michaelteresko7833
    @michaelteresko7833 4 роки тому +2

    You got this down my friend. Offer good service, solid products and a humble, honest character. Ever think of running for Congress ?
    Your success is well deserved.
    Thanks so much

  • @jamesnobles4050
    @jamesnobles4050 4 роки тому +10

    i follow you with everything and watch all your movies, your my go to man for solar,enough said,,

  • @deborahminter4807
    @deborahminter4807 4 роки тому

    Will, you started your video by saying how powerful this system is ...that it can power a cabin yet you only show how to connect one AC (extention cord) outlet. Could you show us beginners how to connect it to a distribution box? I need to connect to: Connecticut-Electric Cesmpsc41grhr Outdoor Power Outlet,120V,30A ...basically its a box with a shore power outlet and two extra regular outlets and breakers.. I know you are tired of catering to beginners but I'm sure many of us could really appreciate your help. Thank you so much for making it possible for off gridders to have electricity:)

  • @realfreedom5029
    @realfreedom5029 4 роки тому +16

    What about for an RV re: the MPPT controller?

  • @johnwera93
    @johnwera93 4 роки тому +1

    You make lives work for basically free. This is invaluable information.

    • @twigg2324
      @twigg2324 4 роки тому

      The videos are his "storefront". He is doing very well out of them, and deservedly so.

  • @jimmyb7474
    @jimmyb7474 4 роки тому +3

    Wow another amazing super great video info and analysis from absolutely the best channel on utube. you hit this one out of the park again. when your sharing such great info no need to worry about the exact cost of the system. people can do some work on the pricing themselves. thank you and keep up the great work and videos you do there fantastic

  • @jedics1
    @jedics1 4 роки тому +1

    I just got my solar working after a LOT of head scratching/buying parts/putting them together and I still don't have grid charging so to see how easy you just put this together kind of makes my eyes roll. The only thing my system has over this one is being able to double the amount of solar when I want but I guess this set up just needs you to go buy another inverter and plug it in....

  • @4philipp
    @4philipp 4 роки тому +9

    Just ordered the combo.
    $675 inverter
    $880 battery
    --------
    $1555 total with tax and shipping. Just a tad over that $1100 mark.

    • @WillProwse
      @WillProwse  4 роки тому +4

      Yeah that shipping cost is horrible. I changed the thumbnail price so people know. Sorry about not adding the shipping

    • @WillProwse
      @WillProwse  4 роки тому +2

      Wait 880? From big battery?
      Did you get the green one? Or white inverter

    • @4philipp
      @4philipp 4 роки тому +3

      DIY Solar Power with Will Prowse the battery is 699, minus a 10% ($70) for signing up for email list, plus $250 for shipping. Makes $880.

    • @4philipp
      @4philipp 4 роки тому +1

      DIY Solar Power with Will Prowse using the link the white inverter was not available. Cheapest 24v was $501!plus tax plus $120 shipping for a green model

    • @WillProwse
      @WillProwse  4 роки тому +3

      @@4philipp ohhhh ok that makes sense then. Oh man I'm so happy your doing this setup. I wish I had this years ago haha it's amazing

  • @riftvalley1765
    @riftvalley1765 Рік тому

    Bro you have a video on everything on market, I just found this inverter on Marketplace for $500 & start searching here comes your detailed video on it, the only downside is it's 120 volts which cannot serve my purpose since I am trying to connect it to my detached garage electrical panel to run everything minus the AC. Thanks like always.

  • @fudogwhisperer3590
    @fudogwhisperer3590 4 роки тому +9

    Can you do a video on how to connect duel system so you can have 2 hot legs in your AC panel?

    • @WillProwse
      @WillProwse  4 роки тому +10

      Sure

    • @dandres21
      @dandres21 4 роки тому

      Hey, that is exactly what I would like to see. I was seeing the schematics and I see is possible for three phase and I assume is the same for two. I am waiting for this vid. Thanks!

  • @kidt3068
    @kidt3068 4 роки тому

    Cleanup the wiring. I use at least 2 straps per wire to keep the wire from moving on the terminal.
    (I’m a master electrician 20 years in the trade)
    Nice work!

    • @WillProwse
      @WillProwse  4 роки тому +2

      Oh god this is not a permanent install haha! I promise I would secure everything if this was more than a demonstration for beginners

  • @markshelton5321
    @markshelton5321 4 роки тому +5

    Thanks for this! Might be perfect for our off grid cabin in the mountains of Colorado...

  • @clintstinytrailerconversio5560

    A very big CON for me is nearly constant fan running with accompanied noise. A light load and light charging current makes it run. I flipped the fans around, which if it helped, I could not tell. I can't do much about inverter triggered fan, but for solar charging I can and did.... adding a Rich Solar 20A MPPT. FYI: my single panel is 395w (41.4V VMP - 9.55A IMP)

  • @rromero2924
    @rromero2924 4 роки тому +18

    Can you do a video on setting up multiple inverters for larger systems?

  • @sausagefingers714
    @sausagefingers714 3 роки тому

    i'm currently converting my touring caravan to solar as the site owners charge £5 per day for mains electric ( £140 per month ) these all in one units seem brilliant for my 495w solar panel and 24v 200ah lithium battery

  • @peterdus3007
    @peterdus3007 4 роки тому +4

    At this price it's hard to believe it has a 60 amp AC charger. Could you do one of your test to verify the ac charger output of 60 amps in a 24v. battery?

  • @odinsbeard1117
    @odinsbeard1117 4 роки тому

    Did not know solar power was this easy!! I am going to convert my storage shed to this so I can ditch the extension cords from the house!!! Awesome video!! Just subscribed to the channel!!

  • @warrenwantoobe1267
    @warrenwantoobe1267 4 роки тому +3

    Thank you I've been waiting for this !

  • @jcfra420
    @jcfra420 3 роки тому

    Been watching your videos for a bit, and you are a freaking solar guru man. Just bought one of these for my rv trailer. Setting up a 500w Santan array with 2 250w used solar panels I saw on your site. The fan noise issue shouldn't be a problem, I am mounting it all in storage space under my bed, so it should be pretty quiet in the living area. Eventually I want to sell my 24ft for a 30ft since I am going to be living in it full time for a bit, so I also thought it would be a great resale value when I sell the camper, since most people want a simple, uncomplicated system and PnP sells.

  • @dbyrd7827
    @dbyrd7827 4 роки тому +3

    Thanks Will, Great video! You are singular. You are changing the world for the better. Thank you!

  • @d201120112011
    @d201120112011 4 роки тому

    One of the things I noticed researching - being bored on night shifts - UA-cam and Amazon etc help me keep awake 6pm-6am - I noticed these products (at least inverter) is NOT UL Listed. Apparently in some states that means You can't legally hook up to grid tie. The seller on amazon mentioned this in the product page for a similar inverter and mentioned a 20% restock fee

    • @WillProwse
      @WillProwse  4 роки тому +2

      Do not hook these up to any grid. Ever.

    • @m.ronaldo7405
      @m.ronaldo7405 4 роки тому +2

      This one is for off grid use only

  • @thesurvivalist.
    @thesurvivalist. 4 роки тому +18

    Looks like I am buying a combo charger/inverter!
    There another 24v 3.5kw LiFePo4 battery on that site for $499, are you going to be checking that one out too?

    • @geraldhenrickson7472
      @geraldhenrickson7472 4 роки тому

      @@happyhealerforpresident2029 >>>>>>What are you talking about ?

  • @nabilali3230
    @nabilali3230 4 роки тому

    I own that inverter for 5 months. running on 2x250 poly panels and two used valence battery. got a good response from seller on ebay

  • @MrLivewire1970
    @MrLivewire1970 4 роки тому +6

    This is a great system, thank you, Will!! This is the way I would go if I was starting a new system.

  • @dienekes4364
    @dienekes4364 3 роки тому

    This is exactly what i need for the shop that I plan to build.

  • @joekub7
    @joekub7 4 роки тому +8

    hey Will, would you recommend a system such as this for a mobile tinyhome / RV? (one that drives around, not stationary). thanks!

  • @nicwesthuizen1986
    @nicwesthuizen1986 3 роки тому

    Please do a video on batteryless grid assist inverters where solar is first priority and the shortfall is drawn from the grid.
    We are NOT allowed grid tie systems. 90 percent of my power usage is during the day.

  • @manfrummt
    @manfrummt 4 роки тому +5

    Question: what's the minimum amount of solar voltage to keep a 24v inverter going?

  • @fpc0041
    @fpc0041 4 роки тому

    You are so exciting. I so much want to buy this Solar Array Inverter and 2 Battleborn 12v 100Ah batteries. and 6 100w 12v panels total 24v for 300w it's still over $3000 to power an upright freezer that will cost me $200 a year to run 24/7. 15 years to break even. Still not cost effective...

  • @patrickslattery3598
    @patrickslattery3598 4 роки тому +3

    So would you recommend this battery in a rv, or a Tesla

  • @whome8192
    @whome8192 4 роки тому +1

    I love your videos. Keep making them. Just a minor correction. In the US, L is for "Line", not "Leg". There are legs of a transformer...but line is what the black should be called. The solar input wire really should be larger if concerned about efficiency. A lot of those 800 watts will be lost in those small wires. The wire gauge is fine for safety...it can handle the current. But a lot of power will be lost to heating those small wires. At low voltages it is much more of an issue than at higher voltages. For 12 and 24 volt systems, try to size the wire one or two gauges bigger than what is needed for ampacity..depending on the length of the run.

    • @WillProwse
      @WillProwse  4 роки тому

      99% of the solar wire run is 10 gauge temco. The last three feet is 12 gauge because it wouldn't reach from the entry gland. Every conductor in my system is the appropriate size, I promise.

    • @WillProwse
      @WillProwse  4 роки тому

      I have a book that calls it leg that I'm currently reading, especially when a panel is supplied with two legs. So I've been calling it that. Everyone is telling me line/live/leg and idk which one to use lol.

    • @whome8192
      @whome8192 4 роки тому

      @@WillProwse I think from NEMA, NFPA, and UL the terminology is Line. As for the solar wiring, Leg maybe appropriate (idk), but for the 120v AC input it really should be Line (BLK), Neutral (WHT), Ground (GRN ). Either way, I do learn a lot from the videos. I have had not experience with these batteries as they have been cost prohibitive to me.

    • @whome8192
      @whome8192 4 роки тому

      @@WillProwse Efficiency is not a real big concern for a backup system like this with power from the grid. For about a 36 foot run at 10 AWG, you would loose about 10% of the power (80 watts in this case) if you could achieve full power from the solar panels. I suspect your runs are shorter than that. In sizing systems for pure off grid systems I am always after every bit of efficiency possible.

  • @zwarst
    @zwarst 4 роки тому +3

    That’s awesome, the fire board you mentioned sounds like Magnesium Mgo FC sheet.

    • @kenputer56
      @kenputer56 4 роки тому +1

      Cement board is cheap and easy

    • @fishhuntadventure
      @fishhuntadventure 3 роки тому

      Inverter, air space standoffs, galv 20ga, air space, two sheets of 5/8 drywall, 12” clear on sides 24” overhead. Pretty sure that exceeds the codes; insurance company might have a specific require and I’d install to that imho

  • @vafarmer7444
    @vafarmer7444 2 роки тому +1

    Can you wire an RV plug to the ac output to run an RV?

  • @thedindon
    @thedindon 4 роки тому +6

    Can you power a regular house with that (lights, refrigerator, plugs, everything)?

    • @mitchelllance5290
      @mitchelllance5290 4 роки тому

      Homes are 100 -200 Amps 5kW-10kW 110-220 volts so no. Tiny house yes. 10-20amps TV, Laptop, lights and fan 110 volts. No upright vacuum, dryer or AC. Would need to connect in Parallel to other systems to make as big as you need. EACH device you use at the same time add them up and build it.

    • @appleone7045
      @appleone7045 4 роки тому

      Also don’t forget, you will need 16-20 pv panels for 4-5kW, the point to powering a whole house this way (of course with more inverters), is to power your loads during the day and charge the battery, so you can run on the battery at night or when the panels aren’t producing enough.

  • @NackDSP
    @NackDSP 4 роки тому

    I bought one of these. 1. Fans run at medium speed non-stop, and it is loud. Pretty much a show stopper right there. How long will that fan last running continuously? What happens when I'm not there and the fan fails? Fans runs really fast and loud when under load (charge or inverter). 2. The inverter neutral output measured 40V ac relative to the case ground screw, so connecting the outlet ground to the case ground trips ground fault interrupt on any plugged in appliance immediately. To work around I connected neutral out of inverter to both neutral and ground on the inverter outlet. Pretty sketchy. Not sure I can connect the case ground to the neutral without blowing this thing up. 3. The PC software works OK. I can't figure out how to log or graph any data. It is a nice idea, maybe for backup. I would pay an extra $100 to get it with more efficient MOSFETs and larger heat sinks, so the fan would not have to run all the time.

  • @afsh221PaChenTaijiquan
    @afsh221PaChenTaijiquan 4 роки тому +3

    Awesome Will. Perfect and I will be using for my off grid cabin. Thanks for all of your videos. What do you recommend for panels? I was going to use Renogy but how many watts do you recommend?

    • @afsh221PaChenTaijiquan
      @afsh221PaChenTaijiquan 4 роки тому

      I see you had 3 panels, but can you tell how many watts each panel was please?

    • @4philipp
      @4philipp 4 роки тому

      PaCTA I recall from a previous that they are 270 watt each. The actual wiring depends on the panels used, wattage, voltage and amp rating.
      Voltage: assuming the panels are 24 volt, I estimate their open circuit voltage to be double. 3 panels in series are 72V or 144Voc - just under the allowed 150V of the inverter
      Amp: I also estimate these panels to be rated between 8.5 and 9.5amps. So 3 panels in series have a current of only 9.5amp but at the inverter it’s broken down to 9.5x3=28.5amps.
      Panels in parallel: so we put two strings of 3 panels in parallel. That will keep the voltage at just below 150v and the current around 57amp. That will satisfy the inverters 60amp rating. If we used 300watt panels, that’s 300x6=1800watts plus minus a little for max output. So we are just under the rated 2000watt rating.
      I’m also looking at the renogy 300watt, 24v panels. I can’t think of a better configuration though.

    • @afsh221PaChenTaijiquan
      @afsh221PaChenTaijiquan 4 роки тому +1

      @@4philipp Thank you very much for the info Phillip. I appreciate the explanation. Even though I have Will's book, still trying to get a handle on this.

  • @KaDaJxClonE
    @KaDaJxClonE 4 роки тому

    Wow. Shoulda got these over the Rich solar kit. Only problem I see is the $1500 doesn't include wiring costs of solar to charge controller. Those MC4 connectors and 10 or 8 AWG wire is expensive af.

  • @crosseyedcricketfarms
    @crosseyedcricketfarms 4 роки тому +15

    This is cool. Thanks Will have a good day.

    • @jakecooling2448
      @jakecooling2448 4 роки тому

      Can you make a video or explain how to set one up to run a full house ex. A house with washer,dryer,fridge,stove and so on

  • @justintyme1449
    @justintyme1449 2 роки тому

    Awesome! 2,000 watts, so I’m new to this, so for a 6,000 watt system, I’m guessing I’ll need 3 controllers, and 3 batteries? I’m planning on using 10 250 watt solar panels. Will not need a house a/c for an RV, but some type of A/C will be used.

  • @josephmoorejr3814
    @josephmoorejr3814 4 роки тому +4

    Hi Will, thanks for this video. This seems like a great setup for my RV, however I'm not sure how I should patch the AC output into the RV panel so as to make all the AC outlets hot, ETC....

    • @WillProwse
      @WillProwse  4 роки тому

      Just run a wire. line neutral ground.

    • @TerrydeAlaska
      @TerrydeAlaska 4 роки тому +1

      Use your shore power input on the RV instead of connecting it to a power pannel in an RV park, connect it to this units output..easy pizzy

    • @josephmoorejr3814
      @josephmoorejr3814 4 роки тому

      @@TerrydeAlaska Thanks, if this is done will the auto transfer to shore power still work if this units wattage rate is exceeded?

    • @TerrydeAlaska
      @TerrydeAlaska 4 роки тому +3

      @@josephmoorejr3814 The auto transfer switch is a switch that decides between shore power and the generator as you know, and it will allow only one or the other to feed the RV. So your RV will think the 2.4 kw inverter is replacing the shower power source and if that source fails, then you will loose power and have to start the generator and once the generator is up and running, the transfer switch will transfer to allow the generator to feed your RV. Hope that helps....

    • @jeannelent314
      @jeannelent314 4 роки тому +1

      @@TerrydeAlaska That answers a big question for me. I don't want to mess with my fifth wheel existing electrical system. Such a simple solution, I don't know why i didn't think of it. Thanks!

  • @pfwag
    @pfwag 4 роки тому

    Great video but 150VDC can kill you if the amps delivered is over 30ma, which those panels can easily deliver and I doubt a 30ma load would drop the open circuit voltage that much. The generally accepted "safe" DC voltages in the US to push the current through a human body is 60VDC for dry conditions and 40VDC for wet conditions.

  • @briansims4365
    @briansims4365 4 роки тому +3

    Hey Will, can I connect a 48v pv array to this unit. The specs say 30v-80vdc

  • @PatrickKusebauch
    @PatrickKusebauch 4 роки тому +2

    This is exactly what I have in mind for my vanlife build. The only thing I am struggling with is the wiring with other components. So few questions if anybody is willing to help:
    1. Where would I connect another 24V means of charging (12V alternator with step-up to 24V)? I am struggling with the idea that if I'd connect it to the battery how the charging would work with the power from both the alternator and the 4-in-1 at the same time. Is there some other component needed?
    2. Where would you connect the 24V/12V load? Again straight to the battery? No problem there? I think so, just asking to be sure.
    3. Just out of curiosity - why would you need a BMS if the battery is connected only to this 4-in-1? I am under the impression that it has all the functionality of BMS except balancing the cells. But you have made a point in some other video that in case of LiFePO4 batteries you practically might need to balance them like once a year or so anyway.

    • @WillProwse
      @WillProwse  4 роки тому +2

      Good questions:
      1. 12v to 24v boost converter. Set the output voltage to lifepo4 absorption, 29V. Ensure that boost converter has current limiting.
      2. Connect a fused line to battery direct for 24v. If you want 12v appliances, run a 24v to 12v step down converter. Super cheap on amazon.
      3. You need bms for multiple other reasons. Temp protection and cell monitoring for LVD and HVD.
      Super simple setup. The converters may seem strange and first, but they are dead simple. Read the manual and add fuses where necessary. Ill probably make a blueprint for this in due time. I have a blue print you can follow for 24v to 12v converter here: www.mobile-solarpower.com/2000-watt-24v-solar-system.html
      Post any specific questions on the forum and we can help: www.diysolarforum.com

    • @ironwizard013
      @ironwizard013 4 роки тому

      @@WillProwse I do have a question.... should I stick with 12 volt panels or can I use 24 volt panels and still keep my internal system 12 volt?

  • @TheMFrelly
    @TheMFrelly 4 роки тому +3

    They do fail after 3 years or so ..

  • @Jack2of3
    @Jack2of3 4 роки тому +1

    I installed the lv5048 in my cabin. Works great. Installing a parallel system in my workshop

    • @WillProwse
      @WillProwse  4 роки тому +2

      Such a easy to use inverter. Only issue I have had is the low voltage disconnect. Make sure its programmed at a voltage higher than your bms disconnect. if not, it can go into safety mode. Probably the easiest split phase inverter to use. Great setup you have :D

    • @Jack2of3
      @Jack2of3 4 роки тому

      @@WillProwse I'll go double check 🙂

    • @Jack2of3
      @Jack2of3 4 роки тому

      Set at 42 for Battle Born. Do you think that is to low?

    • @WillProwse
      @WillProwse  4 роки тому +4

      I would do 45.2v. that's 11.5v at 12v. Should work great. If one battle born goes into safety mode, it's a big pain in the butt with 48v system. Make sure they are all charged up to 100% when you connect them in series

    • @ericjackson6082
      @ericjackson6082 4 роки тому +1

      @@WillProwse Can you do a video on programing one of these I got one and I thought you could hook it to the grid and charge your batteries but can't figure out how to do that??? Thanks for your time Will!! You are doing a great job!!!

  • @mikemollatt5091
    @mikemollatt5091 2 роки тому +1

    Good to have your tutorial, Will. How many of these inverters have you installed now, and what would you say about customer satisfaction and general reliability?

  • @AtlasReburdened
    @AtlasReburdened 4 роки тому +1

    If you're worried about it being attached to something flammable you could easily solve that by doing wood/foil/fiberglass fire cloth/inverter. For those who don't have a concrete or cinder block wall to mount it to.

    • @WillProwse
      @WillProwse  4 роки тому

      Smart idea!!

    • @teekay1785
      @teekay1785 4 роки тому

      and metal

    • @AtlasReburdened
      @AtlasReburdened 4 роки тому

      @@teekay1785 Yeah, just a piece of sheet metal would do, but fiberglass cloth is cheap, relatively insulating at high temps, and simple foil should do well enough to dissipate the hotspots that leak through. By all means though, if you have some 3mm copper sheet lying around, just use that.

    • @AtlasReburdened
      @AtlasReburdened 4 роки тому

      @@WillProwse Thanks mate.

  • @jeffnelson2924
    @jeffnelson2924 3 роки тому

    Just heads up you have to change the battery type before you get to the function will is talking about option number five switch it to user then you can program

  • @aero70charlie
    @aero70charlie 4 роки тому

    This is great...only problem is I need a budget friendly spit phase for a 50 amp camper, for back up only

  • @JbowlizzleKC
    @JbowlizzleKC 3 роки тому

    Maybe design a system for emergency circuit for people’s home to charge from main when necessary but have their own circuit with gas generator option when needed

  • @BH-qi9cq
    @BH-qi9cq 3 роки тому

    Great video! I'm looking to set up a trailer system or a portable system with 4 440w mono for emergencies and/or reduce energy costs.

  • @bradquinn4161
    @bradquinn4161 4 роки тому

    You might want to look into getting a couple of ferule crimpers. One for the larger stuff (battery) and one for the smaller stuff (panels and small ac). They have pretty much become code for everything Europe.

  • @PeterGregg
    @PeterGregg 4 роки тому +1

    Hi my friend, long time no, but that isn't your fault :) I wanted to say hi and was prompted by the rolling color flicker to say hi now :) To kill that, lower your shutter speed. You can do that 2 ways. Note the settings the camera is using and then set the camera to M in the video settings (different than in the still settings). Replicate the settings manually but set the shutter at 1/60 shutter or lower (should be a multiple of the P mode) and then fine tune it to the best exposure using the OTHER settings. The other, and easier way, is to set the video part of the camera to "shutter priority" which is the S setting in the menu. Then set the shutter speed to 1/60 and let the camera handle the rest. The setting for the mode is done in the menu and not on the dial on top of the camera. If you need help call me and I will be glad to help. Love you dude, be well. Great video as always and thumbs up 👍

    • @WillProwse
      @WillProwse  4 роки тому +1

      Oh wow thank you Peter!!! Good to know :D do you have a lav mic you can recommend? And shotgun mic? I try so many and I'm lost

  • @andreblanchard8569
    @andreblanchard8569 4 роки тому +1

    The high no load power draw kills it for me, at least in the house. The 208 volt 3ph unit may be of interest in the workshop where it is only turned on when needed and a smaller more efficient inverter used for lighting and small loads.
    My favorite inverter is an old Trace 2512SB with a search mode power draw of about 0.3 watts.

    • @WillProwse
      @WillProwse  4 роки тому +1

      Did you try power saving mode

  • @shanepowell5115
    @shanepowell5115 4 роки тому

    I'm new to this so how many of these types of batteries (the large ones) AND # of solar panels, also ? wattage per panel is best. On the 12volt, 24volt and the 48volt type?? These systems are AWSOME. I WOULD CERTAINLY APPRECIATE YOUR ADVICE!!! I JUST DON'T TRUST ANYONE ELSE'S OPINION!!! I TRULY THINK YOU ARE DOING A WONDERFUL THING BY GIVING PEOPLE SO MUCH KNOWLEDGE. AGAIN THANK YOU. signed, Shane P.

  • @59KYHighlander
    @59KYHighlander 8 місяців тому

    Just got the shock of my life today. I had the RECC come out and tell me what it would cost to run power back to my barn. I have a 56x80 pole barn where I keep my boats and tractor and such. The RECC wanted $12,000 to run the lines. I told the guy I'd just buy a solar system and run it like that.
    My question is would this inverter work without an AC input? I don't want to run AC back there due to the cost, so I'll set up a pure solar system. Need to run about 20 LED tube lights and about 6 outlets. Is this the system I need, or should I go to something more expensive/powerful?

  • @olgairizarry7750
    @olgairizarry7750 4 роки тому

    Thank Will! for the time you put into it , I just order the 12v one , I'm planning on making a portable one. Since Here in Puerto Rico we are in huracane season, and light goes on and off, and all ready 2 storm, and is just the beginning the season until November 😎. hey how about make something portable!

  • @stephanebellemare4729
    @stephanebellemare4729 3 роки тому +1

    I purchased one of these inverters and it didn't work out of the box! It was showing codes that recommended sending back to the company. MPP solar refused to send me a new unit. They wanted me to change the mother board. I did that and it still didn't work. They still refused to send me a new unit! Very disappointing!

  • @richardbrennan6369
    @richardbrennan6369 3 роки тому

    Hi Will. Great work your doing. Very impressive. I’ve been a contractor all my life and . Found myself homeless living in my truck . I would like to by a school buss up here in Ontario Canada. Convert it into a schoolie . I don’t no how to live off grid . But I’ve been learning. Your very helpful . My fear is living in the winter months . Minus 20 I believe it’s possible to have the solar work the fridge , shower hot water, and well I was thinking some radiant heat . Maybe some hot water travelling there some water lines to some wall mounted heaters. Could you give me some ideas.

  • @cheddar2848
    @cheddar2848 4 роки тому +2

    I bet you had fun building this, this is awesome, thank you for your knowledge.

  • @mdc1802
    @mdc1802 4 роки тому

    I just had a killer idea. Home appliances like fridges with inbuilt deep cycle batteries. Great for blackouts or save money on AC power overnight. Feel free to rip me off. I'm used to it.

  • @metternichk7499
    @metternichk7499 4 роки тому

    Good luck!
    I bought also this junk. After one Jear and some troubles with the van and seller, I only use Viktron easy solar.

  • @nomadman1196
    @nomadman1196 4 роки тому

    Great System! I got mine set up and working with two Valence 12 volt batteries for the 24 volt setup. I have four 250 watt panels at 49 OCV. I ended up connecting two panels in parallel and series wired the pairs together so not to overcharge the MPPT Controller. Will's settings worked great with no problems. Thanks again for info! 👍👍👍

  • @hhaupt1
    @hhaupt1 Рік тому

    Will thanks free of books and videos. They are great!

  • @MrBruce0777
    @MrBruce0777 2 роки тому

    I as many other love your great informative video's. Have you ever done or reviewed POWMR inverters? The super low prices are super tempting But then again if you don't say it's good on your video's I don't want to chance it. I went to your web site and I see you are out of the complete package deal all in one price complete. I've shared some of your video's too.
    .

  • @njm121
    @njm121 4 роки тому

    Great video thanks. Can you add a wind mill to this system? If not what alternative hardware can I add so that I can add a windmill and solar panels together.

  • @sNEAKYnIGHTmUPPET
    @sNEAKYnIGHTmUPPET 4 роки тому

    You may have already heard this but when describing the alternating current terminals it’s ground line snd neutral G L N.

    • @WillProwse
      @WillProwse  4 роки тому

      Book next to me calls inverter output hot lines, "legs". You can call them leg, line or live. Or hot lead. Whatever works for you

    • @sNEAKYnIGHTmUPPET
      @sNEAKYnIGHTmUPPET 4 роки тому

      DIY Solar Power with Will Prowse yeah, of course, it is a HOT leg, theneutral leg, and the ground leg. They are all legs, but the L doesn’t stand for LEG, it refers to LINE, as in Line voltage Leg
      Another thing will, please don’t take this as negative, I only help correct because i think that what youre doing is great and I want you to do the best job possible. I am an electrician by trade, just trying to help you as you are helping the masses.

    • @WillProwse
      @WillProwse  4 роки тому

      @@sNEAKYnIGHTmUPPET good point, oops

    • @sNEAKYnIGHTmUPPET
      @sNEAKYnIGHTmUPPET 4 роки тому

      DIY Solar Power with Will Prowse another point I wanted to bring up was when you first tested the mpp solar unit, you complained heavily about only having two mounting holes at the top and needing VHB TAPE or a strap to hold the bottom... did you look in the wiring section at the bottom and not see the screw hole to hold in the bottom? Maybe on your next mpp video you could mention this as it may have turned off some potential adopters. I know mine has ‘this hole,and in. Later vid I saw that you used the hole to mount it, but you never verbally addressed it. Just my $0.02

  • @wilhelmloewen8455
    @wilhelmloewen8455 4 роки тому

    So I think that this is a better way to go for a home install instead of the titan solar generator

  • @normancomeau371
    @normancomeau371 3 роки тому

    Great stuff.
    Could you do a vid on a system that has super cspacitors in circuit for handling large startip load like heat pump or big saw

  • @cowboymcq6711
    @cowboymcq6711 2 роки тому

    I’ve been following you for a while amazing videos so in depth but not boring which is fantastic ❕❕❕ any deals on MPP all in ones units out there ⁉️

  • @digicabtech
    @digicabtech 4 роки тому

    Instead of using the ac output to the FAN for example. Can I plug the AC Output to the HOME POWER socket? Would it be SAFE? If yes, Does it mean the electric generated from the panels are sending back to the grid ? Please reply

  • @Totogita
    @Totogita 4 роки тому

    My sister gave me the 800 watts version of this, it works but draws 1 amp. It also stays on A.C when the sun comes up. The charge controller compared to a Renogy does not behave like an MPPT. Because I worked for a subsidiary of GE I was able to program this. The manual for this box is terrible. I am going to disconnect the charge controller and put back the Chinese one I had since it draws less power.

  • @williamfisk4841
    @williamfisk4841 4 роки тому

    New to this technology. Bartered some 290w panels and a Solaredge SE7600H-US inverter. Can I run an off grid system with this inverter? Can I power my shop direct from inverter during the day without battery backup system? Thanks. Watching and learning

  • @Space_Reptile
    @Space_Reptile 4 роки тому

    they made that 2424 for a while now, the one i have is called "pip 2424ms" its about 5 years old now and functionally identical, a superb unit and very cheap on the used (payd 130 for mine)

  • @donclark8834
    @donclark8834 3 роки тому

    I`m alway trying to upgrade my system all the time . So i just bought some new panels and they are 285 watt`s , 24 volts DC 20 low and 48 high In total i will have now 1425 watts at right now 78.10 @ 81.05 amps as metered
    I in puted them directly into my 12 volt system with no problems Yes there is a minor problem ? my batteries are to small , to mixed in size and watt hours 2 are lead acid and 1 is 95 watt hours liph4 , the 4th is 50 amp hours Liph4
    Now i`m watching watching your youtube program on 24 volt MPP solar installation I went to your suggested sight and they do not carry a 12 volt on grid 5 Kw system .
    Where else can i look for a 5 kw on grid system inverter

  • @derricklyle1539
    @derricklyle1539 4 роки тому

    Then I Will! Learning so much! Question. Does Big better deliver to eastern Canada? I emailed the question to Big battery last week but still no answer from them! Thanks all!

  • @wes_wunder
    @wes_wunder 3 роки тому

    Question: this looks perfect for my needs. I can fit 6-8 panels on my RV roof, what should I get?

  • @myklm8456
    @myklm8456 4 роки тому

    Will, I am a full time RVer. I am thinking of moving up to a Prius Hybrid or a Toyota Highlander Hybrid, with a small low aluminum trailer with a giant unfolding solar array. The solar array would charge the Hybrid batteries and store its output. I am ok with an extra battery bank in the trailer, with energy transfer to the vehicle when possible. Is this idea do-able and where can I find information for me to study and design this idea? I love your attitude and projects!

  • @nafoibot
    @nafoibot 3 роки тому

    Have you ever thought of using this Inverter as a Uninterruptable Power Supply for Electronics? What do you think the pros and cons are to using these over a UPS like APC or Eaton?

  • @sammyhighdesert1231
    @sammyhighdesert1231 2 роки тому

    Great show. I am wondering if the 2400 watt inverter in this unit would be enough to run two freezers and one refrigerator. The frig has about an 800-1000w surge and both freezer could be on.

  • @brake1adam
    @brake1adam 4 роки тому

    Great video for us new people... vary simple and well exsplained. Thank You.

  • @budherod5569
    @budherod5569 3 роки тому

    I was always taught (here in America) that "L" stood for Load, "N" is for Neutral, and "G" is for Earth Ground.

  • @eduardogomez2483
    @eduardogomez2483 4 роки тому

    Thanks for the video, it will work without a solar pannels, i mean only chargin the batterys from the wall? Thanks

  • @nerdyhomesteader5014
    @nerdyhomesteader5014 4 роки тому

    Thanks for the videos. I have learned a lot from you. Am about to build one the other systems you recommend for my shed. Thinking about building this one for my house but am wondering how would you go about connecting DC appliances to this setup? Have a 24v freezer and water pump that will need to eat.

  • @Starfox-zg4tk
    @Starfox-zg4tk 4 роки тому

    Nice work. Quick question. If I was to set this up in my tool shed to power up my landscaping lights. Can I install a sprinkler system in the tool shed? I’m just afraid it might start a fire.