How To Install a Two Head LED Emergency Light - AKT-EM01W

Поділитися
Вставка
  • Опубліковано 8 вер 2024
  • This is an unboxing, and how to install the Meet Your Home AKT EM01W Two Head LED Emergency Light found at amzn.to/2ZiJf5L.
    I was needing to add another emergency light in the office, so I decided to show you how easy it is to do yourself. Luckily, I already had a J-box installed on the wall, to ad one of these in the future. If you don’t have a junction box to attach a light to, do not worry. This light can be easy installed in a multiple of ways, including on the end of an electrical conduit, or even surface mounted.
    * Installation starts at the 2:10 mark. Jump to it here: • How To Install a Two H...
    Product description:
    - Long lasting, efficient ultra-bright white LEDs.
    - Adjustable LED lamp heads provide optimal center-to-center spacing.
    - Charge rate/power "ON" LED indicator light and push to test switch for mandated code compliance testing.
    - Internal solid-state transfer switch automatically connects the internal battery to LED lamp heads for minimum 90-minute emergency illumination.
    - Surface mount via quick-connect back plate
    - Fits most standard size junction boxes and snaps into place to make internal electrical connections.
    Specifications:
    - Input Voltage: 100-277V 50/60HZ
    - Backup Battery Life: 90 Mins
    - Warranty: Lifetime
    - Wattage: 3W
    - Voltage: 120/277
    - UL Listed
    Mounting:
    - Surface mount via quick-connect back plate fits most standard size junction boxes and snaps into place to make internal electrical connections.
    - Conduit mount knockout on top of housing.
    - Suitable for wall or ceiling mount.
    To get more information on this emergency light, or to purchase one, go to amzn.to/2ZiJf5L.
    FOLLOW US ON SOCIAL MEDIA:
    Facebook: / monkeyingaroundreviews
    ----
    * As an Amazon Associate I earn from qualifying purchases.
    * Some products reviewed by MAR may have been provided for free or at a discount.

КОМЕНТАРІ • 38

  • @Seriousdrew
    @Seriousdrew 4 роки тому +3

    You made self explanatory brother ur the best I couldn't figure it out I thought I was suppose to connect all the wires.. ty

  • @dominichunter9799
    @dominichunter9799 3 роки тому +2

    I had not connected the battery so that helped. Thanks.

  • @maskretek4099
    @maskretek4099 3 роки тому +1

    Oh my god - what happened at 7:15 ?
    Visual Art!
    I bought a last one of these that was mounted as a model in the store.
    Meaning: No Manual.
    Thanks to you showing us how to install ; )

  • @mikeymoet1847
    @mikeymoet1847 3 роки тому +2

    you are incredible , thank you so much! you save my life....

  • @marisolbaque6
    @marisolbaque6 Рік тому +1

    Briliant explanation, wel done

  • @KenRupin
    @KenRupin 4 роки тому +1

    Thank you for making this.

  • @FireAlarmDude5967
    @FireAlarmDude5967 4 роки тому +7

    Cool! And that light will actually last for 90 minutes, not seconds.

    • @MonkeyingAroundReviews
      @MonkeyingAroundReviews  4 роки тому +3

      Thanks. I didn't even catch that I said seconds at the end. I did say it correctly at the beginning though.

    • @FireAlarmDude5967
      @FireAlarmDude5967 4 роки тому +1

      Yeah. Nice video!

  • @somersetky.mallmaintenance8681
    @somersetky.mallmaintenance8681 2 роки тому

    Good video you explain things very well.

  • @j.d.bishop190
    @j.d.bishop190 4 роки тому +9

    90 seconds? Don't you mean 90 minutes?

    • @MonkeyingAroundReviews
      @MonkeyingAroundReviews  4 роки тому +4

      Yes. I accidentally said seconds at the end. I did say minutes correctly at the beginning though.

  • @ledsionlighting
    @ledsionlighting 3 роки тому +1

    LOL,I love your video,so passionate

  • @Thunderbolt1003
    @Thunderbolt1003 4 роки тому +3

    You need to adjust the lampheads to get optimal lighting in a power failure

  • @chihanlee512
    @chihanlee512 2 роки тому +1

    No emergency lights with sockets:(

  • @samdag9755
    @samdag9755 4 роки тому

    So very interesting... may I know what was the input voltage or you source voltage..

  • @coreyguerrette8525
    @coreyguerrette8525 2 роки тому

    Question! I just installed some lights. Once I put power to it the button was a steady red. I looked at the owners manual and it says nothing about a steady red. Will it ago away with time?

    • @MonkeyingAroundReviews
      @MonkeyingAroundReviews  2 роки тому +1

      As you can see in the video around 07:05 mine has the red light as well. That is letting you know that the light has live power going to it. It is always on when the light is receiving power to it. Most emergency lights and exit signs I have used and / or seen have light light on it.

  • @BILLYJOE957
    @BILLYJOE957 2 роки тому +1

    90 seconds ?

    • @MonkeyingAroundReviews
      @MonkeyingAroundReviews  2 роки тому

      Yes. I accidentally said seconds at the end. I did say minutes correctly at the beginning though.

  • @photodok
    @photodok 3 роки тому +2

    90 seconds? I think you mean 90 minutes.

    • @MonkeyingAroundReviews
      @MonkeyingAroundReviews  3 роки тому

      Yes. I accidentally said seconds at the end. I did say minutes correctly at the beginning though.

  • @muffin4801
    @muffin4801 Рік тому

    Would it work with 220v line?

  • @breadsticks98
    @breadsticks98 Рік тому

    277 volts?? Lool

    • @CurtWelch
      @CurtWelch Рік тому

      LOOL? 277 is correct. It's a standard voltage for commercial lighting in the US. It's the single-phase voltage of a 480 3-phase system. 480/sqrt(3) = 277.128... Most newer lights sold for commercial environments will work with 277V, 240V, or 120V power.

  • @the4hunters
    @the4hunters Рік тому

    Too bad it’s only 90 seconds, mine goes 90 min 7:34