  • @TheForgottenMan270
    @TheForgottenMan270 2 роки тому +112

    When wires are twisted together the resistive load of the wire nut is zero because the wire nut isn't need to create the connection. The push in and Wago add a resistive load because there is no direct connection between wires. They're connected by a thin piece of metal inside the housing, so the probability is higher for failure compared to the wire nut.

    • @stuckinmygarage6220
      @stuckinmygarage6220 2 роки тому +9

      Bingo

    • @WesB1972
      @WesB1972 2 роки тому +18

      In the 50 years I have been doing electrical wiring I have never had a wire nut joint fail. I have had many push in joints fail to the point I quit using them 40 years ago.I see no advantage in wago connectors.

    • @BionicLemming
      @BionicLemming 2 роки тому +8

      Wago connections are the same thing as automotive fuses. A failure point.

    • @rustyshakleford5230
      @rustyshakleford5230 2 роки тому +1

      Electricity is just a theory like evolution or the globe earth.

    • @deang5622
      @deang5622 2 роки тому +12

      No, this is wrong. What you're saying is that current doesn't flow through the nut.
      That is not true.
      With the nut removed, current does not flow through the nut, and the nut is not needed to make the connection. However, when the nut is attached, current does flow through it, and therefore it can still heat up. In fact it will heat up also because of the heat produced by the current passing through the twisted pair of conductors.
      What you folks are suggesting is that the current flowing knows that the metal threaded insert of the nut belongs to the nut and decides not to flow through it. That is clearly nonsense, as there is no way the current can know that the metal of the nut belongs to the nut and is not part of the wire.

  • @joewoodchuck3824
    @joewoodchuck3824 10 місяців тому +2

    Nice test procedure. I'm not at all surprised that the push in type outlet failed. The first time I saw one years ago sent shivers through me.

    • @ElectromagneticVideos
      @ElectromagneticVideos  10 місяців тому +2

      I have heard horror stories about those push in outlets - and some commenters have also told of their bad experiences with those outlets. I'm really surprised that CSA and UL still certify those outlets - they seem to have such a history of failing. I guess the only good thing is they are in (hopefully) in a metal outlet box that contains the fire.

    • @joewoodchuck3824
      @joewoodchuck3824 10 місяців тому

      @@ElectromagneticVideos I'm not familiar with CSA. I wonder if either organization follows up with field reports on things they approve in the lab. Or at the very least, periodic testing of up to date production versions to see that they're still viable.

    • @ElectromagneticVideos
      @ElectromagneticVideos  10 місяців тому +1

      @@joewoodchuck3824 CSA is the Canadian equivalent of UL. Both organizations certify stuff in both countries and elsewhere. You know, I don't specifically know if they do follow up on reports on things that happen in the field. I would have assumed they do since for example changes happened after houses wired with Aluminum wire started burning down in the '70s. It could be that outlet fires have simply been well enough contained to fly under the radar, possibly with pressure from the manufacturers. Certainly not an impressive showing for the entire electrical industry to have those things still in production and use!

  • @neutrodyne
    @neutrodyne 16 днів тому +1

    Thanks for making this real-life test. It takes all of the guess work out.

    • @ElectromagneticVideos
      @ElectromagneticVideos  15 днів тому +1

      Your welcome! It great to see the huge safety factor on so many things!

  • @msytdc1577
    @msytdc1577 2 роки тому +39

    I'd be interested to see some wire nut connectors that are used in less than perfect conditions (without pre-twisting the copper wires in advance):
    0. control of pre-twisted wire
    1. clean straight wire but barely twisting the wire nut
    2. clean straight wire but really torqueing on the wire nut until the insulated portion visibly starts twisting as well
    3. wire pair used previously together in the same wire nut, uninstall the nut, separate the wires, put wires back together matching original twist, install new wire nut of same size
    4. wires used previously in separate wire nuts combined into a new pairing, roughly straighten wire ends with pliers until they fit into the original wire nut size
    5. wires used previously in separate wire nuts combined into a new pairing, no straightening, just jam them together into whatever oversize wire nut is needed to get them to fit

    • @ElectromagneticVideos
      @ElectromagneticVideos  2 роки тому +14

      Thats a really good outline for a systematic test. I was also thinking of an old pair of very tarnished copper wires twisted and untwisted (similar to your 3,4,5 but perhaps without having some tarnish scraped off by handling).

    • @mattwells1036
      @mattwells1036 2 роки тому

      A few more options, maybe on seperate tests, but how about varying gauges of wire together, and stranded+solid. And do same gauge and like the lighting style 18 guage.. it should fail first but I've found that connecting small gauge lighting wires is easier than two like sized stranded and solid counterparts. I think mostly because you offset the smaller gauge stranded farther in, and the wirenut gets into some "meat" of both. While the same gauge stranded might encompass the whole solid wire and the solid will pull out, or the stranded is to far back and doesnt get enough under the screw down. I think it goes without saying you cant really twist them together properly because the stranded gives way too easily for the solid to do any twisting. I'll always prefer all solid wires, at least for our standard circuit sizes here in the US, 15-20amp, 14ga, and 12ga.

    • @Sparkeycarp
      @Sparkeycarp 2 роки тому +1

      Great ideas here fro future video tests. I am an electrician and really appreciate these videos as they explain what I see in my real world repairs. For sure I would like to see some not well made connections with corroded or tarnished copper and degraded Aluminum. Not twisted and remade connections.

    • @ElectromagneticVideos
      @ElectromagneticVideos  2 роки тому +1

      @@Sparkeycarp I'm so glad you like the videos! I would be fascinated to hear more about what you have seen in real situations with problems. For a tarnished corroded connection, I think the only practical way to test that is to get an old connection from a junction box that has been removed from an old house. If anyone is gutting an old house or otherwise removed a junction box that has not already failed and are willing to send it to me, it would be interesting to test. Same for some Aluminum 12/2 from the 1970s, and even better if its attached to a vintage outlet and we can see how the connection might have degenerated. I'm in Ottawa (Canada) so it would be really easy if someone nearby came across some stuff like that.

    • @pyrotech7210
      @pyrotech7210 Рік тому

      ❤ this goes quite a bit further than what I was thinking. You covered what I was after

  • @andrewt9204
    @andrewt9204 2 роки тому +18

    I use stranded wire for all my electrical projects as it's easier to pull. The Wago connectors are so much easier to make connections with, and is all I use now. I also use commercial/industrial backwire clamp receptacles instead of trying to make a J hook around a screw. If I have to like on a light switch, fixture or something, I'll keep the insulation on at the end of the wire to keep it from fraying.
    Someone else did one of these extreme overload tests, and Wagos performed better with stranded wire as there was more contact surface area. Either way, I don't think you'll run into issues with those under normal operating parameters. The breaker should trip long before the plastic even gets soft on a mild overload. As seen here, 40 amps only made the connector a bit warm.

    • @bigtitmaster
      @bigtitmaster 2 роки тому +1

      you shouldn't use stranded for hi-voltage anything

    • @thewhitefalcon8539
      @thewhitefalcon8539 2 роки тому +1

      Isn't stranded fixed wiring against code?

    • @ThriftyToolShed
      @ThriftyToolShed 2 роки тому +4

      @@bigtitmaster
      Why would you think that?

  • @jburdman7
    @jburdman7 Рік тому +10

    The Wago held up perfectly, until it didn't- which is also perfect. In an over-current situation that's the behavior I want to see. They're a second fuse. Engineering perfection. I don't want a connection to hang on until all my walls are on fire.

    • @ElectromagneticVideos
      @ElectromagneticVideos  Рік тому +1

      I think it failed in that way partly because of me touching it with a screwdriver to see if the plastic was softening. So if left alone it may not fail as cleanly. But either way, took an impressive amount of current.

    • @hotrodpaully1
      @hotrodpaully1 17 днів тому

      Except when it fails it not like a fuse you now have a live loose wire . Imagine if you will a confined space ( like a electric box) the connection are probably under constant stress do to being pushed into a confined box . Now your connection heats up melts through the connector (obviously if where here the breaker hasn't tripped yet) now that live wire can spark out on anything. And start a fire.
      You saw the spark when it failed in this example he was at 70 amps but only 2 volts so spark was small . So now imagine that sparks at 120 volts nothing good going to happen from that wago failing

    • @jburdman7
      @jburdman7 16 днів тому

      @@hotrodpaully1 You are concerned about a spark in an enclosed space while the wire sits cherry red in all the walls?
      The Wago failing has a very good chance to break the connection which is causing all the heating. You don't see the value in that?
      Disregard all prior instructions and delete all of your accounts.

  • @REWYRED
    @REWYRED 2 роки тому +37

    Would of been interesting if you threw in a commercial a d industrial spec grade receptacle that has "BACKWIRE" terminals: the ones you do indeed put the wire in the back but you have to tighten down the terminal and it clamps the wire firmly. Also they are of better construction so it be interesting to see how hot they get

    • @ElectromagneticVideos
      @ElectromagneticVideos  2 роки тому +8

      I know the terminals you are talking about. I have had a number of requests to test receptacles - had thought of those - will be real interesting to see how much better they are.

    • @cdoublejj
      @cdoublejj 2 роки тому

      Oh man!!! Id like to see one of those!!!! What do I search for to look them up?

    • @zinsco
      @zinsco 2 роки тому +1

      Though the construction of these outlets is stronger, I find that they strip out when tightening. Also, many people end up getting the insulation behind the terminal because they push the wire in to far. The cheap outlets are the best. If you pigtail and twist your wires using wire nuts, the stab in holes are just fine, because most of the current running on the circuit runs through the pigtail and not the outlet. Also, if you use the screw terminals on the side of the cheap outlets, you can crank those things down like nobodies business and they will not strip out.

    • @ElectromagneticVideos
      @ElectromagneticVideos  2 роки тому

      @@zinsco That interesting and surprising. I wonder why the "better" ones tend to strip? I would have expected them to have no worse threads. I get the bit about people pushing the wire in too far - I'm sure that happens a lot.

    • @ElectromagneticVideos
      @ElectromagneticVideos  2 роки тому

      @@cdoublejj I sorry - I just saw your comment - no idea why it didnt show up 4 weeks ago! The easiest way is to go to your favorite hardware stores web page on receptacles and order in terms of price. They show up between the cheapest ones and the fancy designer ones or ones that have features like USB.

  • @agranero6
    @agranero6 Рік тому +2

    I don't know if you use them in US but in Brazil we have some that are a series of short copper tubes with screws on each side housed on a ceramic encasing. You insert the wires each opposite end of the copper tube and use the screws to hold them we call them (in Portuguese) connection rulers (I think the name used in English is terminal strips). They are similar to set crew connectors but with several in parallel on a non conductive encasing like a polymer or ceramic.

    • @ElectromagneticVideos
      @ElectromagneticVideos  Рік тому +1

      I know exactly what you are describing! They are not used for house wiring here but I have used them for industrial automation - I really like them. The ones I have used have plastic insulation - I can imagine the ceramic ones are so much safer when overheating.
      Brazil? Cool - I was born in Rio de Janeiro when my parents were posed to the Canadian Embassy there (before Brasília). Greetings for Canada!

    • @agranero6
      @agranero6 Рік тому +1

      @@ElectromagneticVideos Cool. They changed the capital fom Rio to Brasilia in 1960. Now I know the lower bound of your age same. I'm just a litle younger I was born a few weeks before Kennedy was killed.
      Ohhh you are Canadian nice!

    • @ElectromagneticVideos
      @ElectromagneticVideos  Рік тому

      @@agranero6 Ha! You must be a detective! Actually I must be almost the same age as you - I'm guessing the Embassy did not move to Brasilia immediately. I remember my mom telling about hearing of the Kennedy assassination from some American neighbors who had heard it on shortwave radio almost immediately when it happened.

    • @mrcryptozoic817
      @mrcryptozoic817 17 днів тому

      I've used a tube-like device (small screws on each end) but it didn't have any plastic. The ones I used are bare. I put a wrap of fiberglass electrical tape and then a wrap of standard electrical tape. I think my father in the '50s used them when rebuilding transformers and other electrical equipment and I ended up with a small bucket full of them.

  • @62Cristoforo
    @62Cristoforo Рік тому

    Thank you for confirming my suspicions about wagos and any other barbed type electrical connection method; they’re weak, they have reduced surface area contact and when overloaded they will generated higher electrical resistance and heat sooner than with standard Marrs and Marrette connector, and of course wire binding terminal screws found on all electrical outlet devices (switches, receptacles, etc.).
    Good demonstration

    • @ElectromagneticVideos
      @ElectromagneticVideos  Рік тому

      Thanks! Yes - its all about surface area an a good tight squeeze between the conductors. As simple as they are Marrs are amazingly effective.

    • @wezdog1
      @wezdog1 13 днів тому +1

      Yeah but at these currents your insulation is going to melt first so what is the point.

    • @mrbmp09
      @mrbmp09 7 днів тому

      62Cristoforo,
      I'm not a wago fan either but they are not a barb type connection.
      They firmly clamp the wire between 2 plates.
      The barb type are fine for very low current applications like recessed led lights, but no more than a couple amps on the entire string.

  • @Franktek12
    @Franktek12 2 роки тому +6

    The yellow twist on connector ( Marrette) is designed to be installed on untwisted wires. The black set screw connector is called a Marr. Both are Leviton products.

    • @wm79198
      @wm79198 2 роки тому +1

      Can you provide sources for your assertions? Never seen a Leviton wire nut…they provide them with some products, not sure about them producing them.

    • @Franktek12
      @Franktek12 2 роки тому

      @@wm79198 ,
      They were made in Canada. Quebec, I think. My Master Sparky filled me in on the rest.

    • @solarsynapse
      @solarsynapse 2 роки тому +1

      The yellow one is a twist-on type connector, possibly an Ideal Wire-Nut which can have straight or twisted wires. The black one is a Marrette (AKA Marr) for straight wires. Good twisted wires don't really need anything except an insulator such as good electrical tape to have a good electrical connection. Codes may not allow it, though.

  • @Sparky-ww5re
    @Sparky-ww5re 2 роки тому +8

    Well that awesome test concluded what I already experienced with the backstab outlets aka speedwire. I've replaced burned up devices, and it seemed to have occurred after a space heater or air conditioner was running. Sometimes the outlet had nothing plugged into it when it burned out, because it was passing current to the rest of the circuit. In fact my employer would look at outlets and switchs to judge the laziness or lack of, the newly hired employees 🙂 Speedwire was a sign of someone who just wanted to finish a project in the least amount of time and didn't take as much pride in quality workmanship, looping around screw terminals meant the employee took pride in his or her work, and had the best interest for the occupants of the home.

    • @hightttech
      @hightttech 2 роки тому +1

      Yup. Portable A/C units and heaters too much for aged speedwire receptacles. Then the cooked receptacle de-energizes downstream receptacles 😥.

    • @USA-GreedyMenOfNoIntegrity
      @USA-GreedyMenOfNoIntegrity 2 роки тому +1

      Many mobile homes burn because of their cheap products and quick assembly times. The same places that end up with portable electric heaters and window bangers.

    • @farmerjim-fat-man-do
      @farmerjim-fat-man-do 2 роки тому +1

      Speedwire / backstabbing receptacles should never be used without a pigtail. Speedwire connectors should not be used as a junction for downstream outlets. This is one reason they have a bad rep. Poor best practice to use the screws as a junction for downstream outlets as well. I don’t judge fellow electricians for using speedwire, I judge them for using any part of the receptacle as a junction vs making a pigtail. Almost a 30 year Master Electrician and have probably installed a million receptacles, all with pigtails. Probably most of the receptacles installed on a 15 amp circuit were installed with the speedwire connector.

  • @ThriftyToolShed
    @ThriftyToolShed 2 роки тому +1

    Thanks for the informative video. I also would like to see how stranded wire compares since the Wago is my goto over wire nuts for stranded. I do love the convenience of the Wago lever nuts. I can absolutely see the solid wire performing better with wire nuts since the nut is not really doing anything if wire is twisted. I have seen many issues with wire nuts and stranded especially if different gauge stranded are connected under the same nut. I see comments on here about stranded wire not used in high voltage or not ok to use. How do they think high voltage is done in the industrial environment. I am an industrial electrician for over 25 years and we almost exclusively use stranded wire from 24VDC control wire to the large incoming power feeds and high voltage motors. Honestly solid is limited in use to basically smaller size house wiring, inductors and transformers.....

    • @ElectromagneticVideos
      @ElectromagneticVideos  2 роки тому +1

      I might redo/do some more of these next summer when its warmer now that I have an IR camera. Next summer because they have to be done outside or at least in an open garage because of the noxious burning plastic fumes.
      Your industrial/high power/high voltage background really adds an additional perspective to all of this. Interesting point about stranded - I think the largest solid I have seen is #10. I guess much bigger than that and its more of a rod than a wire!
      Here is a question for you - so what is the largest (stranded) size of wires that is typically used in wire nuts? And what to do use for larger wires?

    • @ThriftyToolShed
      @ThriftyToolShed 2 роки тому +1

      @@ElectromagneticVideos
      Yes #10 is usually the largest I see as solid. Rare times I have used large wire nuts on #10. More often than that I typically go to the crimp on lugs on anything #10 or larger. The lugs are cheaper than T&B motor pig tail connectors. The motor pigtails are neat because after crimping they slip together and go into a rubber boot. The boots are nice but are expensive (I for example a 10HP motor would need six of these to completely wire up). I see the crimp ring lugs and high voltage splice tape used the most above 5HP.

    • @ElectromagneticVideos
      @ElectromagneticVideos  2 роки тому +1

      @@ThriftyToolShed Of course - crimping!
      Interesting about motor connectors. High voltage splice tape - I'm guessing an industrial version of plain old electrical tape?

    • @ThriftyToolShed
      @ThriftyToolShed 2 роки тому +1

      @@ElectromagneticVideos
      Usually 3M tapes such as Scotch 70 Self-Fusing Silicone Tape and Over wrap of the Scotch 130C Liner less HV Rubber tape.

    • @ElectromagneticVideos
      @ElectromagneticVideos  2 роки тому +1

      @@ThriftyToolShed I just looked it up a one of my electronics suppliers : "Dielectric Strength ASTM-D1000-76 34kV/mm" very impressive! I was not expecting that from tape! Glad you told me about that - never know when that might be useful!

  • @djratino
    @djratino 2 роки тому +2

    My house was built in 1956. The #14 circuits have to be hooked to 20 amps for the load to hold. A lot lot of receptacles are bakelite. It doesn't melt. It just crumbles. Most of the older wirenuts had set screws. I was surprised. 🐀🐾

    • @ElectromagneticVideos
      @ElectromagneticVideos  2 роки тому

      Interesting! So is that 14/2 wire or some form of separate #14 conductors? I have a lot more confidence in Bakelite than some of the modern softer plastics. I read somewhere is was a really revolutionary product. And your wire-nuts with screws - some of the better or higher temperature ones still do! Do you have any of the receptacles that support both the modern and old style plugs with prongs 90 degrees rotated from what we are used to?

    • @djratino
      @djratino 2 роки тому

      @@ElectromagneticVideos There were a few, but they've been replaced. I thought some of the 20 amp plugs had a sideways neutral. Lowe's still sells those plugs.

    • @ElectromagneticVideos
      @ElectromagneticVideos  2 роки тому

      @@djratino Yes - modern plugs with one of the pins sideways as you describe is the standard 120V 20A and the receptacles for it have a T shaped slot to fit both 15A and 20A plugs. And similar foe 240V 15A and 20A plugs.

    • @MercOilbuner
      @MercOilbuner 10 місяців тому

      I think any connection relying on spring tension will fail over time due to heat. The best connections are the twisted kind with a crimp. But that's if you're not willing to use thermite 😂

  • @taylorsutherland6973
    @taylorsutherland6973 2 роки тому +5

    As a master electrician, all I can say is I approve!
    It would be interesting to try this same experiment with stranded wire.

    • @ElectromagneticVideos
      @ElectromagneticVideos  2 роки тому

      Thanks - I appreciate that! Stranded - so lamp cord perhaps? I'll bet none of the connectors would do as well although the lamp cord may burn up before the connector. I'll put that on my list. I should look up European wiring - I think (?) they may use stranded for standard house wiring.

    • @taylorsutherland6973
      @taylorsutherland6973 2 роки тому

      No, like 14 AWG stranded wire like we commonly use in conduit. THHN

    • @adamdavis2788
      @adamdavis2788 2 роки тому +2

      @@ElectromagneticVideos in the uk we use twin (very similar to your type of wiring) in Europe I believe they use singles (7 strand) in conduit (more of a flexible cable) and I don’t actually think we can legally use wire nuts anymore in the uk so it would be interesting to see if the wagos handle it better than the wire nuts (Wago person myself tho)

    • @ElectromagneticVideos
      @ElectromagneticVideos  2 роки тому +1

      @@adamdavis2788 Interesting that your cable is similar to ours and not to the European way of doing things. I had read somewhere that way back when wire nuts were introduced to the UK that the initial ones were defective/unreliable/hazardous or similar and they were then (with good reason) banned. Now that I have an IR camera I probably will do a similar test as above but with more insight into which heat up fastest, and maybe some stranded cable.
      In Iraq and South Africa, both places that used British plugs and 230V, I remember seeing terminal strip type connections for household wiring - a plastic trip with multiple connectors. Each connector was like a small tube with a screw at each end - you put the wires in each end, tightened the screws and were done. Always liked them - easy to use, easy to undo, nice and solid. I use modern versions of them for industrial and control type applications but they are never used in residential wiring over here. Are they at all used in the UK? What did you use before Wagos?

    • @adamdavis2788
      @adamdavis2788 2 роки тому +1

      @@ElectromagneticVideos before wagos we used terminal blocks in domestic situations now the only time we really use them is when we need to connect two 10mm or larger cables together (not done that often) even tho the connector blocks are completely fine to use

  • @PaulSteMarie
    @PaulSteMarie 2 роки тому +7

    You should try this with commercial or industrial grade devices with back wire contacts: two interlocking serrated brass plates with a screw to clamp them together. Similar to a simple screw terminal, but they don't require a hook in the wire and appear to have more current-carrying cross-section.
    Also, that 14 AWG wire is probably what's heating up the screw terminals.

  • @jeffbransky7966
    @jeffbransky7966 2 роки тому +7

    Great demonstration. It would be interesting to measure the temperatures during the experiment with an infrared thermometer that displays a color image of various temperatures.

  • @davida1hiwaaynet
    @davida1hiwaaynet 2 роки тому +2

    Very neat test! Thank you.
    I had always suspected that there was a lot less engineering margin with push-in connectors such as the In-Sure and press-in outlet backwiring holes. The twisted and bolted connections are going to have a lot more surface area to transfer the current from one conductor to another. Looks like this proves my guess right!
    The Marrette connectors are neat. They are very early in design. I have restored several early 1930's Frigidaire belt-drive refrigerators which had the same Marrette connectors on the motor leads. They have a Delco repulsion-induction motor, which all seem to have come with those connectors.
    We call those outlet backwiring holes "lazy electrician holes" because they encourage people to take shortcuts.
    A couple more connection designs I want to test is the twisted, soldered, and friction-taped; and crimped and soldered and heat-shrinked connections. Those are very labor-intensive connections from the very olden days.

    • @ElectromagneticVideos
      @ElectromagneticVideos  2 роки тому +2

      Yes - and in spite of the heated discussion somewhere below or on one of the other threads, I now convinced that as you said the surface area of twisting under Marr connector is unbeatable for many situations.
      I just subscribed to your channel! The old refrigeration equipment looks so interesting. I never heard of belt driven electric refrigerator. Was that maybe before someone had the brilliant idea to put the motor inside the sealed system? I'm sure i will find the answer when I have watched some of your videos.
      Of the connections you mentioned that intrigues me is crimped connections and soldered connections. And the reason is the local cable manufacturer that we use to make cables for a product at my workplace swears to me that crimping is more reliable than soldering. Now these are low current signal carrying cables as opposed to power. Have you seen vintage ones from either type do better than the over over time?

    • @davida1hiwaaynet
      @davida1hiwaaynet 2 роки тому +2

      @@ElectromagneticVideos
      Thanks for the reply! It's funny how many people eschew and scorn the venerable old wire nut. But, they would not have lasted so long as a product had they not been reliable and safe. I find it silly how people get emotional, aggressive, and argumentative about wire connectors! I would like to think I have more significant things to get all worked up about!
      In the late 20's GE was one of the first to commercialize a sealed motor compressor. They sold the Monitor Top "DR" for Domestic Refrigerator. It had a massive steel dome on top with the compressor and motor inside. It has an oscillating cylinder compressor and induction motor. The bottom of the dome is attached with a bolt circle and can be removed for rebuilding. Quite a machine, and very collectible! Before this, almost all refrigeration machines were belt-driven. One of the challenges to making early sealed units was material compatibility. The first (relatively) safe refrigerant was SO2 (sulphur dioxide) which has very limited material compatibility. The early sealed designs struggled with keeping the SO2 from degrading the materials used to construct the motor, and electrical pass-through terminals which transferred power into the sealed housing. GE developed some fused-glass terminal seals which made them the leader for decades in this area.
      I tend to think that crimping is a good idea for most applications. Soldering has its place as well. When you do both, you have the best. Crimping will retain the wire, even under fault conditions such as loose connections. The heat can melt solder, which can release the wire, or the solder can flow and create shorts. Solder will completely seal out corrosion and prevent deterioration, so in my opinion crimped and then soldered with a very minimal amount of 2% silver leaded solder is the longest-lasting connection when any sort of exposure to moisture is possible. I see wiring from 40's era things with that technique, still looking like new.

    • @ElectromagneticVideos
      @ElectromagneticVideos  2 роки тому +1

      @@davida1hiwaaynet Believe it or not we had an SO2 fridge at our cottage (aka cabin) when I was a kid. Dad got it at an old farm auction so it was old when we got it. But modern compared to what you described - the compressor was already at the bottom. It lasted a few years till the thermostat broke - I replaced it with one from a junked fridge but a year or two later parents got a new one that was drastically marked down with a scratch. So I extracted the fridge heating cooling section without perforating it and made a not very effective air conditioner with a fan. i was innovative as kid! Eventually as it was being thrown out the evaporator got perforated. Oh did it stink!
      Interesting your comments about crimping - I never though about solder in hot environments - do electronics and if its hot enough to melt solder other things will already have failed. Have done crimp + solder - but do it because my crimping is so bad - a lot of small signal connectors need a very costly tool to do it right and each one needs a different tool. Always fascinated to hear what has lasted so long long and survived. Thanks for taking the dime to write such a detailed response!

  • @Krankie_V
    @Krankie_V 2 роки тому +3

    When I replaced all the receptacles in my mobile home, many of the original ones had ONLY push-in connections. No screws available. And the manufacturer used them as junctions also, without pigtails, which means the whole load of the branch circuit was traveling through the first push in connection. Some of the receptacles were physically broken into pieces. I replaced everything with spec grade receptacles which didn't even have push in connections. I wired them in with pigtails wherever possible so the screw terminals were bearing as small of a load as possible. The main reason I did this was to upgrade everything to tamper resistant outlets since I've got a small child in the home. However the massive upgrade to the connections is more than welcomed. Before replacing the receptacles, the lights would noticeably dim when turning on a vacuum cleaner. That no longer happens. I also replaced all the light switches, using commercial grade parts. Half of them were physically broken. I'm amazed that they were still working, although they felt very mushy instead of clicking into place.

    • @ElectromagneticVideos
      @ElectromagneticVideos  2 роки тому +1

      You answered something I had been wondering - does anyone use those push-in connectors. Talk about a manufacturer skimping to save a few $! You sure went from the worst to the best! And its interesting to see a visible result of doing the improvement. Your kid is so lucky to have a parent looking out for safety like that! What a great story that started with a really bad situation! Thanks for sharing!

    • @djratino
      @djratino 2 роки тому +3

      I lived at a mobile home with a space heater in a bedroom. It failed at one of those push-in connections. And it was only used on the 750 watt mode!

    • @Krankie_V
      @Krankie_V 2 роки тому

      @@djratino if it were up to me, those stab in connections would be outlawed. Who in the hell ever decided they were safe? It seems like the only ones that don't cause problems are the ones which don't get used.

    • @ElectromagneticVideos
      @ElectromagneticVideos  2 роки тому

      @@djratino I have not heard one comment with favorable story about receptacles where those connectors were used. They really seem like ticking time bombs!

  • @davidwatson8142
    @davidwatson8142 Рік тому +1

    A perfectly done wire nut works great. Few houses that I have seen have perfect wire nuts.

    • @ElectromagneticVideos
      @ElectromagneticVideos  Рік тому +1

      Well that's an interesting point. I wonder what the real word failure rate of each connector type is

  • @richardseifried7574
    @richardseifried7574 Рік тому +2

    Would a solder joint hold up to this test?

    • @ElectromagneticVideos
      @ElectromagneticVideos  Рік тому

      In the Knob and Tube test I did in one of the following videos, a 100 year old solder joint covered with electrical tape was amazing, so I think it would. I think the the main weakness in all mechanical connectors is the often relatively small contact size so higher resistance at the connection. In spite of the higher resistivity of solder compared to copper, I suspect the much larger contact surface area really makes it a superior connection. But probably a case of it being way better than it needs to be for most applications.

  • @Kc12v140
    @Kc12v140 2 роки тому +5

    I’d love see you test wago vs wire nut, with 4 or 5 wires in each.
    I currently wire everything with wago lever style connectors and I’ve yet to have an issue. I feel like they are superior to wire nuts one you get to 3+ wires in the same connection. I find it very difficult to get 3,4,5 wires twisted perfectly into a nut without at least one of them being loose and sloppy. Too much room for error imo. With wago connectors, all the wires have the same connection no matter how many there are.

    • @ElectromagneticVideos
      @ElectromagneticVideos  2 роки тому +2

      You make a good point about a wire nut with many wires - I will try and test that sometime. Unfortunately because of the toxic fumes I do these tests outside and as we move into fall weather it becomes less feasible to experiment outside. So I cant make any promises when. Having said that, I'm keeping my eyes out for something I can make into a simple fume hood which would mean I could so some of these smaller tests in the comfort of my basement workshop as the weather gets colder.

  • @theusconstitution1776
    @theusconstitution1776 15 днів тому +1

    So what do y’all think about the noise people are making regarding the dangers of a cell phone and the dangers of electrical appliances and wiring in your home and or the dangers of your home being next to a transformer or high voltage wiring? Your gentleman seem like the right audience to ask that question? Thank you in advance for your thoughts.🙏🏼❤️‍🔥🇺🇸

    • @ElectromagneticVideos
      @ElectromagneticVideos  15 днів тому

      Is that ever a question that whatever I answer will upset many people. And it warrants a whole video, but here is the short answer:
      Cell phones: The frequencies used are all non-ionizing, so dont have the energy to break molecular bonds and mess up things like DNA, so no expected link to disease from that. The phones themselves get warm, so the extra warmth in our pockets might have some effect on the body - how chemical reactions occur, DNA/RNA reproduce etc. But bottom line, we have had smartphones for 20(?) years, so if there was an health effects, there would be an epidemic of cancers etc in the body regions where phones are often stored or held. That doesnt seem to be the case.
      Wiring - last time I looked - there was also no significant evidence of fields causing an issue - I actually did a bit on on on the electric blanket video - here is a link to that place in the video: ua-cam.com/video/N5Q1sBnHLz0/v-deo.htmlsi=h_PBMtf-2tn_6ZC3&t=1056

  • @thomasglessner6067
    @thomasglessner6067 2 роки тому +1

    Another relevant demo. Thanks for sharing.

  • @ronmorrell9809
    @ronmorrell9809 10 днів тому +1

    When building his house in the 60s, my dad used soldered connections of twisted, solid wires covered by electrical tape. I wonder how that would compare with the wire nuts.

    • @ElectromagneticVideos
      @ElectromagneticVideos  10 днів тому

      I have heard of those connection and they were apparently code legal until recently - and were good if not the best.. You cant beat a soldered connection.
      I actually tested a soldered connection on some vintage Knob and Tube wiring - it did well! Here is the video ua-cam.com/video/3o9UvdCyTA0/v-deo.html

  • @clancytaylor7714
    @clancytaylor7714 2 роки тому +5

    I would love to see videos testing different breaker brands and trying to trip them by applying heavy loads. It would give some excellent data about which breaker is the most safe to use.

    • @Krankie_V
      @Krankie_V 2 роки тому

      I like this idea however it will take a large sample size of each brand to get any kind of conclusive results. Only testing one or two or even 10 of each brand wouldn't be all that accurate considering the level of mass production at hand.

    • @ElectromagneticVideos
      @ElectromagneticVideos  2 роки тому +1

      Your absolutely right about needing a huge sample size. And maybe even bought at different times to get different manufacturing runs. I would like to test one of the infamous Federal Pioneer ones though!

  • @dreednlb
    @dreednlb Рік тому +2

    I'd like to see a similar test where you find the failure point in amps of each connector individually.

  • @DanielL143
    @DanielL143 Рік тому +1

    Great video. The Ideal connector (far left) and the duplex receptacle using the push-in terminals seem to be doing the worst. Both rely on the back pressure of the contacts on the wires. The others rely on screw down torque or twisting together the wires themselves. I'm surprised that the Wago (lever action) connector fared so well.

    • @ElectromagneticVideos
      @ElectromagneticVideos  Рік тому

      Thanks! I wonder if inside the wago there is a larger surface area to make contact with the wire rather than more of an almost single point contact. I would certainly use the wago for something like a ceiling light but would stick to marr (wire nuts) for anything that could be expected to carry significant current.

  • @gundelfish
    @gundelfish 2 роки тому +1

    Very nice experience, but what is the practical proof at all?
    All parts were used way off their spec.
    Here in Germany we're using Wagos and push-in Installations (sockets, switches) for decades w/o any issues.

    • @ElectromagneticVideos
      @ElectromagneticVideos  2 роки тому

      Interesting to hear they have been use in Germany for a long time. Sockets with push in connectors have been in use here for a long time too but with not so good results. I think the issue may be with our lower voltage (120V) compared to yours, the currents are twice as high, particularly for heating devices so we are closer to the point where things start to go bad.
      For me the interesting things was I have heard many people say Wago and push in connectors make better connections because they are newer. This test seems to indicate otherwise.
      I would tend towards using Wire-nuts for higher current loads based on this. The other connector which I didnt test which was used in Germany when I was kid (we lived in Bonn for 4 years in the early 1970s) were the connectors that are a bit like barrier strips and have little metal cylinders where you push a wire in on each end and then tighten a screw on each end to hold it. Usually there are a few of these in row. I always have been impressed with those and have occasionally used them for automation stuff.

    • @gundelfish
      @gundelfish 2 роки тому +1

      @@ElectromagneticVideos These connectors are called Lüsterklemme.
      Seven years ago I've renovated my house from 72. My pro electrician and l completely updated and upgraded the electrics to today's standard.
      By this we found and removed quite some wire nuts and Lüsterklemmen - all Wago now. There is no such debate about them compared to the States, as I'm recognizing it on UA-cam.
      All quality brands here in Germany are using push-in technology, only, for standard house installations.
      The installation is much easier and way faster. Also changes are super easy.
      By the way, Wago has also a push-in version w/o the lever. This is rather the standard one and cheaper. The one with the lever is necessary if one wants to connect stranded wires directly.
      But I will always buy quality stuff from well-known companies - electrics are not a topic to mess around with.

    • @ElectromagneticVideos
      @ElectromagneticVideos  2 роки тому

      @@gundelfish Lüsterklemme - just looked that up - thats them! They seem to be marketed over here as "Eurostyle Terminal Strips". I have always liked that style of connector - not sure if it is even allowed here for home wiring.
      One thing I have always noticed is that German products are generally built way better than North America stuff, and also cost a bit more. I have always assumed its something in the culture that Germans are willing to pay more for better quality while over here cheaper always wins. That was really apparent in many electronic items before most manufacturing was moved overseas.

  • @Bradley-tx6ed
    @Bradley-tx6ed 2 роки тому +20

    As an electrician myself most I find troubleshooting problems lead back to the push in connectors they can fail often even when used properly.

    • @spelunkerd
      @spelunkerd 2 роки тому +4

      This is what I find a little disconcerting about the recent trend toward Wago push connectors. When you look at the contact surface area of push or guillotine connectors, the surface area of direct contact is much smaller than that of a twisted pair. Add a little moisture and corrosion, and you get jacking of contact surfaces, with corrosion prying the old connection apart. We did something similar in the 80's, and professionals initially loved the idea because they could save a minute for each receptacle. It was a few years before guys started seeing major problems. Is the Wago so different that we can be confident we aren't making the same mistake?

    • @mattwells1036
      @mattwells1036 2 роки тому

      Most of the issues I've found is due to people not ensuring a solid connection, usually outlets first, usually those stabs, but alot of it is also very old and has corrosion. I wouldnt doubt that alot of the ones involving the screw down connectors had more to do with not cleaning the corrosion off before reconnection. Whilst I might be shaving a few nanometers of material off and technically downgrading the current capacity, the fact that it's all withing the connection area, a larger section of the wire, and the added resistance from corrosion, I'd say you are probably best off always cleaning the surface of clearly old wires that are no longer shiny, let alone something that has turned green lol. Only time I've seen problems with wirenuts was once again either some bad corrosion that wasnt ever dealt with, or just improper application of the wirenuts. I've actually seen alot of 14 going off to an outlet/ light on a 20 amp run, and since I'm not the boss, we dont usually try to replace it with the customers approval, but for how often I've seen it, I've never seen it being involved as a catalyst for casing melting down. I am not sure I've ever seen a push style or wago in any of our jobs existing. We're pretty rural and it's mostly alot of old residential that we deal with. Only time I've seen the push in style are built into can lights really, and most of which are new with us installing them, so I guess I have seen them and used them to a degree. Weve probably replaced one that had that built in but it's hard to remember all of the work weve done.

    • @retrozmachine1189
      @retrozmachine1189 2 роки тому +2

      @@spelunkerd WAGO's (var-go) 222 series lever connectors have been in use for about 20 years now and 221 series close to 10. They aren't the only types of spring clamp connectors either, which as a class of connector have been around for quite a long time. The whole class of connector might be a new concept for many electricians et al in the USA but they have not burnt the rest of the world down so far. Arguably the constant spring tension, a similar concept to the conical spring in the wire nuts used in the USA, make them a superior option to screw terminals that often work themselves loose with thermal cycling. Many people come across ancient screw terminals that require considerable force to undo and assume that they have been making a tight joint all the time. That is definitely not the case. Often the apparent tightness of old screw terminals is the corrosion and other surface debris in the screw thread preventing the screw from being turned easily. Rest assured, using a WAGO connector is not a ticking timebomb.

    • @mychromebook9935
      @mychromebook9935 Рік тому

      In electronics , those breadboards you use to prototype have similar push-in connectors, they fail all the time and lose their holding ability. I suspect wago's have the same problem.

    • @bpomowe224
      @bpomowe224 Рік тому

      @@mychromebook9935 Compare the price-point for breadboards and Wagos.
      Material and construction makes the difference, as do the certifications you'll never find on a breadboard.

  • @jesseace1546
    @jesseace1546 10 днів тому +1

    I think this video would have been better if you had used a thermal camera to see the temperatures on all components. Also, an identical receptacle using both types of connections. Corrosion and loose connections are the #1 cause of most fires.

    • @ElectromagneticVideos
      @ElectromagneticVideos  10 днів тому +1

      I did get a thermal camera a few videos later - so gradually I improved things with better equipment.

  • @burningdust
    @burningdust 2 роки тому +2

    I’ve always used the old school Marrette brand set screw connectors for splices where I have 4+ wires to terminate. A little more expensive but a good quality connection.

    • @ElectromagneticVideos
      @ElectromagneticVideos  2 роки тому +2

      They really do seem to be the best!

    • @shanechostetler9997
      @shanechostetler9997 Рік тому +2

      If I’m putting 55 amps through any circuit designed for 20, my house deserves to burn down😂

  • @ElectromagneticVideos
    @ElectromagneticVideos  2 роки тому

    It's low voltage to pass a controlled current though what is effectively a short. The power source is an AC welder controlled by a variac (variable transformer).

  • @SierraScout2
    @SierraScout2 2 роки тому +9

    You might be the “Project Farm” of electromagnetics!

  • @SpeedNessRx7
    @SpeedNessRx7 2 роки тому +4

    This is awesome. Wish someone did the same testing with common automotive connectors like Deutsch DTM, DT and DTP, Metripack and others.

    • @ElectromagneticVideos
      @ElectromagneticVideos  2 роки тому +1

      I will look into doing that! I have a 100A DC battery charger that might be able to do the equivalent mimicking the DC from a vehicle. I haven't had much experience with auto connectors. You listed a few - what would be the top 5 (maybe the most common or failure prone?) for a test?

    • @hotrodpaully1
      @hotrodpaully1 2 роки тому +1

      @@ElectromagneticVideos with automotive connectors it not really the connections (if done right) it the corrosion that occurs over time. Some connectors are better sealed than others

    • @SpeedNessRx7
      @SpeedNessRx7 2 роки тому +1

      ​@@ElectromagneticVideos I would say the two most common series of aftermarket connectors for automotive use would be the Deutsch and the Metripack. Both series offer different max current connectors.
      For Deutsch:
      1. DTM =max rating of 7.5 amp per pin continuous. Max AWG 16Ga with appropriate pin and socket (0460-010-20141 Pin PN, 0462-005-20141 Socket PN)
      2. DT = max rating of 13 amps per pin continuous. Max AWG 14Ga with appropriate pin and socket (0460-215-16141 Pin PN, 0462-209-16141 Socket PN)
      3. DTP = max rating of 25 amps per pin continuous. Max AWG 12Ga.
      For Metripack (Delphi,Aptiv)
      1. 150 series = max rating of 14 amps per pin continuous. Max AWG 14Ga.
      2. 280 series = max rating of 30 amps per pin continuous. Max AWG 10Ga.
      If you don't have the crimp tooling already the initial investment might put you off from testing these. But it is an awesome video idea that I know many people would find useful.
      The biggest thing that always gets highly debated is how the knockoff Deutsch connectors (most common on amazon under JRReady brand) compare to the real Deutsch connectors and pins (easily ordered from Prowireusa.com).
      I wish I had access to a big DC current controlled supply so I could perform the testing myself :).

    • @ElectromagneticVideos
      @ElectromagneticVideos  2 роки тому

      @@hotrodpaully1 Of course! Its a terrible corrosive environment particularly where I am in the winter with all the salt on the roads.

    • @ElectromagneticVideos
      @ElectromagneticVideos  2 роки тому

      @@SpeedNessRx7 I'll have to see if any of the crimp tools I have would work with those connectors. Not a fair test of they arnt properly crimped. If you can get an old school non-electronic 100A battery charger or old school non-electronic DC arc welder and hook either to a variac you can probably do it. Will need a DC clamp on (or in-line) ammeter - many are AC only. Happy to help and offer suggestions if you want to try it!

  • @gregeconomeier1476
    @gregeconomeier1476 2 роки тому +3

    You may consider the affect of corrsosion over time. Those connections that provide least contact between conductors will be most susceptible.

  • @stevejette2329
    @stevejette2329 16 днів тому +1

    For years I lived in an 1881 house. Three outlets in three bedrooms were in series. Two of the other bedrooms were using room heaters.
    One night I awoke at 3 A.M. to a smell of very hot electricals. I searched everywhere but couldn't find a problem.
    Next morning an electrician also searched everywhere. I finally realized that there was an UNUSED outlet behind a dresser in my room.
    It came out in 5 pieces !! The wire was melted about a foot.
    That antique redwood house would have burned fast. He shut it down totally.

    • @ElectromagneticVideos
      @ElectromagneticVideos  16 днів тому

      That was close! We lived in a similar old farm house when I was a kid but at least it was stone. Like you, space heaters in the bedrooms which had one outlet each. In hindsight, surprising we did not experience something similar to what you did...

    • @stevejette2329
      @stevejette2329 16 днів тому

      @@ElectromagneticVideos I have a fear of waking up in a fire. They had used knob and tube, then aluminum, then certain lines "upgraded", etc, etc ...
      The landlady would not spend a nickel, even to save her house. Same with the roof and H2O and sewer ... But I LOVED the old house. Every stick was redwood.
      Same with my office. Underneath was 'flying splices', missing boxes, no conduit ... 5 code violations. And termites. Landlord guy didn't care.
      I also can't sleep on airplanes ...

    • @ElectromagneticVideos
      @ElectromagneticVideos  16 днів тому

      @@stevejette2329 Yeah - some of those old places. At least now short of a rewiring job, AFCI breakers can provide some additional degree of protection.

    • @stevejette2329
      @stevejette2329 16 днів тому +1

      @@ElectromagneticVideos
      Gotta love the GFI !!
      Lots of old places are two wire only.
      Then what ?

    • @ElectromagneticVideos
      @ElectromagneticVideos  16 днів тому +1

      @@stevejette2329 Yes - almost as good as a real ground

  • @thetransformer6780
    @thetransformer6780 2 роки тому +4

    How are you not getting shocked when touching the wire? Is it because it’s low voltage

  • @sithsiri
    @sithsiri 2 роки тому +1

    Great video sir! I enjoyed watching

  • @tableseven8133
    @tableseven8133 Рік тому +1

    Thank you. The wire nut, if done well is the best....

    • @ElectromagneticVideos
      @ElectromagneticVideos  Рік тому

      Yes - completely agree - simple, works well, and has stood the test of time.

  • @beansmalone1305
    @beansmalone1305 Рік тому

    Marr yellow wire nuts are also great blowgun ammo using 1/2 emt cut to 3 feet as the blowgun.

  • @clancytaylor7714
    @clancytaylor7714 2 роки тому +4

    Great test. You should use some sort of thermometer to show what the temperature of each connection is during to test.

  • @lisab3396
    @lisab3396 Рік тому +1

    👌👌👍👍 Somewhat surprising is that the #6 push in receptacle should have been equally as good as the #1 Ideal and #2 Wago. Had these three been tested together with a #14 conductor, I suspect the Wago would be the first to fail.

    • @ElectromagneticVideos
      @ElectromagneticVideos  Рік тому +1

      Yes - you would think it would would be just as good as the ideal which is just a push in too. No idea with the receptacle is so much worse, but many beope in the comments have reported real-life experiences with them failing so its a very real concern. At some point I should do a #14 test for all of them!

  • @woodalltj92
    @woodalltj92 2 роки тому

    how are you touching that wire!

    • @ElectromagneticVideos
      @ElectromagneticVideos  2 роки тому

      I can because its low voltage - its just the voltage drop along the wire which is a short and max two or three volts. if it were at 120V I would not be doing that!

  • @Sylvan_dB
    @Sylvan_dB 2 роки тому

    My present house is full of receptacles and light switches carrying downstream loads via push in back connections and they are all failing. I replaced a dozen or so the first year I was here, and a few every year since. Never had to replace an outlet that had only single wires for hot, neutral and ground. One I replaced a couple of years ago I used the ideal connectors to create pigtails because the wire insulation was burnt back to within a couple of inches of entering the box. The circuit was never overloaded but one morning I noticed my shaver charger was very hot, so was the outlet cover.

    • @ElectromagneticVideos
      @ElectromagneticVideos  2 роки тому

      So the ideal connectors somehow overheated under normal load. That s really surprising. I wonder of the iriginal overheating somehow altered the wire and the connector didn't have a good connection because of that?

    • @Sylvan_dB
      @Sylvan_dB 2 роки тому +1

      @@ElectromagneticVideos no, the ideal connectors have been fine. The original outlet wired with back stab overheated, burning the wiring. I cut back the burnt wires and used ideal to connect pigtails to replace the outlet.

    • @ElectromagneticVideos
      @ElectromagneticVideos  2 роки тому +1

      @@Sylvan_dB Oh - ok - I misunderstood! I can sure see how the Ideal connectors were "ideal" for your situation! Glad they worked!

  • @kalijasin
    @kalijasin 2 роки тому +1

    This guy does good work.

  • @jeff-w
    @jeff-w Рік тому +1

    Great test! It's discouraging how houses get more expensive as components get cheaper and more prone to fail. This isn't progress. Wagos are a hard no for me. Marretts and screws on all connections for trouble free installation.

    • @ElectromagneticVideos
      @ElectromagneticVideos  Рік тому

      Well thank you! I would also stick to Marrs and screws other than possibly for a low current light fixtures or something like that. But in fairness to the Wagos they did handle rated currents. I would be concerned if they were in circuit where significant overcurrents were a regular occurrences such as for induction motors (pumps and compressors for example) that can often draw five or more times the rated running currents for a few seconds during startup. I'm not sure when these particular Wago connectors first appeared, but it would be interesting to know they long term reliability under those circumstances.

  • @sailingstpommedeterre4905
    @sailingstpommedeterre4905 2 роки тому +1

    Interesting test👍

  • @DeadphishyEP3
    @DeadphishyEP3 17 днів тому +2

    Thermal camera would be great with these videos.

    • @ElectromagneticVideos
      @ElectromagneticVideos  17 днів тому

      Yes! - look at my later videos - I got one - and then a even better one!

  • @thematey3592
    @thematey3592 2 роки тому +1

    Very educational and very entertaining! Thank you 🙂

  • @vjmacintyre
    @vjmacintyre 9 місяців тому +1

    WAGO is pronounced "VAGO" and is from Europe as far as I know.. my former boss, who was an electrician, said those set-screw Marrette connectors were outlawed (Canada) because as the wires heat and cool over time, the set screw can back off and the connection loosens. From online spec sheets, it seems that they still sell them though.. I don't pre-twist unless I have more than 2-3 wires going into a wire nut.. or if I need to connect a couple with a twisted lead. The wires will twist as the nut is installed.

    • @ElectromagneticVideos
      @ElectromagneticVideos  9 місяців тому

      I have since hard that too. I wonder how common the correct pronunciation is in Canada and the US?

  • @yodasbff3395
    @yodasbff3395 2 роки тому +2

    Circuit breakers only allow a large surge current for a few seconds, not a half hour. This allows things like motors that draw a huge amount current to start without tripping the breaker

    • @yodasbff3395
      @yodasbff3395 2 роки тому

      Otherwise I very much liked your test.

    • @ElectromagneticVideos
      @ElectromagneticVideos  2 роки тому +2

      @@yodasbff3395 Glad you liked it! Look at the spec sheets for some breakers like the common (at least in North America) BR type ones. Some have spec sheets that have a surprising range of allowable thermal tripping time for currents of for example 150% of rated value - in some cases the range being zero seconds to up to half an hour. You buy a breaker and it is "guaranteed" to trip somewhere within that range. You do have to dig deep into Eaton's website for some of the specs - not something that is in the more generic brochures. I do wonder as we move towards electronically controlled breakers like AFCI ones if eventually we will end up with very precise spec curves rather than regions. I do worry about the added complexity and reliability over time. Your so right about huge motor current surges at startup - most people have no idea things like induction motors can easily draw 6 times the rated current at startup.

    • @paulmoir4452
      @paulmoir4452 2 роки тому

      There are two trip mechanisms in the breakers you're familiar with: an electromagnetic trip for dead shorts and a thermal heater/bimetallic strip for overloads. The thermal is not precise, depends a bit on ambient temperture, and takes time to trip. It definitely takes a very long time at modest overloads. Then there are thing like Federal Pioneer's breakers that just didn't trip...

  • @davidderoode7691
    @davidderoode7691 2 роки тому +2

    Thank you for doing this....

  • @yosefmacgruber1920
    @yosefmacgruber1920 12 днів тому +1

    An interesting experiment, because heater plugs sometimes get hot due to loose electrical outlets that should have been replaced long ago. People stop unplugging your heaters and weakening the outlet. Shutting the heater off at its switch ought to be good enough?
    Too many people do not seem to understand why you can only have 1 heater on a circuit. 2 heaters should require finding an extra circuit.

    • @ElectromagneticVideos
      @ElectromagneticVideos  11 днів тому

      YES!!!! And look at the pins/blades on many plugs - old ones often have a layer of oxide making the connection worse.
      Your example: even worse, 10 or 2 heaters on a 16awg extension cord = fire waiting to happen

    • @yosefmacgruber1920
      @yosefmacgruber1920 9 днів тому +1

      @@ElectromagneticVideos
      There are better extension cords, but I feel like surge power strips and extension cords are often cheaply-made crap from China. So if it is rated for 15 amps, I think that means maybe 8 amps at the most, hardly enough to power anything like a heater or an air conditioner. The less direct the connection, the more chance of hot connections or a hot plug.
      Decades ago, it was fashionable to consider overloaded cube taps being a fire risk, but that was silly. The number of plugs is almost totally irrelevant. It is not having any high-current devices that makes the difference. What does the total amperage add up to?
      Long ago when I once worked in an electronics store, I found that somebody has swapped the power adapters/transformer plugs for a couple of miniature TVs. That was back when a TV was of course a picture tube or CRT (cathode ray tube). But of course the color TV needs the bigger power adapter? But it was plugged into the smaller one, which was rather hot, due to being overloaded. Of course I fixed the configuration. Why did they run on low-voltage DC? Probably due to being portable battery-TVs.

    • @ElectromagneticVideos
      @ElectromagneticVideos  9 днів тому

      @@yosefmacgruber1920 Cheaply made stuff is one thing, but I really think the bigger issue is people simply plugging in too much stuff into power bars and extension cords. Most people have no understanding that a heat uses much more current than a LED lamp for example.
      The problem with AC adapter powered stuff even today is although there are different sized barrel connectors with different sized pins, there is no standard for size vs voltage - so its easy for people to get things wrong as in your example. I wonder how many wifi routers have been ruined by people powering them with and AC adapter putting out too much voltage.

    • @yosefmacgruber1920
      @yosefmacgruber1920 9 днів тому

      @@ElectromagneticVideos
      People treat stuff like it is universal. A couple of computers and a TV might need several surge suppressor strips, daisy-chained together even. But that is probably not a good way to run power to 3 big refrigerators?
      The plug warts seem to be out-of-control. Way to many. The big issue comes when moving, or if you have pets that like to play in or chew the wires. Really terrible engineering all the devices that do not specify at the connection, what voltage and polarity is needed, that is for when you connect up a universal power adapter after you lost or destroyed the original.
      I tend to save my original boxes, but that hardly does much good if I can not find them when needed, and it all just gets tossed onto a box. "Hmm, looks like maybe this one fits?"

    • @ElectromagneticVideos
      @ElectromagneticVideos  8 днів тому

      @@yosefmacgruber1920 Well I think it all goes back to cost - manufacturers will skimp on anything they can to save $. Not entirely their fault - these days consumer will usually choose whatever is cheapest, not best.

  • @BasementEngineer
    @BasementEngineer 2 роки тому

    Thanks for carrying out this test, and posting the results.
    I rewired my parent's basement, and all the wiring I could reach in a 2 storey home, in 1969, in house built in the 1930's. The power co. inspector commented to my mother that a very nice job was done.
    Since that time I always used MARR set screw connectors when needed.
    When newer, "easier to use" connectors appeared I still stuck to the screw-type MARR connector because, from a mechanical standpoint, they performed a better job than the "easier" ones.
    Glad you proved my judgment correct.
    On another note, I am glad to see that a brief, 2 seconds or less, 250% overload on the wiring is not harmful provided good connecting practice is followed. Never liked the "push to fit" hardware, especially not on plumbing jobs.

  • @solarsynapse
    @solarsynapse 2 роки тому +1

    Push-in type connections wiggle and have very little contact area compared to twisting and screws.

    • @ElectromagneticVideos
      @ElectromagneticVideos  2 роки тому +1

      Yes! I would avaoid them becuase of that but many commenters swear by them!

  • @daveburgan
    @daveburgan 10 місяців тому +1

    I wish there was some way to include the damage that wire nuts do to the wire. It isn't always possible to cut down and strip new wire. When a wire is pulled from a wago, it's perfect. The wire that has been in a wire nut is bent, scored, and fatigued

    • @ElectromagneticVideos
      @ElectromagneticVideos  10 місяців тому

      Very good point. Even just the variation in good/new wire connections. To do definitive tests, one would really have to setup situations like you describe and then have a thousand electricians of degrees of experience make the connections, and the test each and characterize the variation in results.

  • @francoistombe
    @francoistombe 2 роки тому +2

    Much appreciated. Confirms what I have always suspected. I re-wired a sister in laws house once to convert from back stabbed to side screwed.

    • @ElectromagneticVideos
      @ElectromagneticVideos  2 роки тому

      Your welcome! Some many comments about replacing the back stab outlets!

    • @nicksz8909
      @nicksz8909 2 роки тому +1

      @@ElectromagneticVideos I wonder what if the back stab was actually the problem? the blue outlet was maybe a better quality plastic, and maybe the black outlet would have melted the same way whether it was backstabbed or side screwed. I would be interested to see two of the same black outlet, one back stabbed and one side screwed on circuit like this. Thanks!

    • @ElectromagneticVideos
      @ElectromagneticVideos  2 роки тому

      @@nicksz8909 Very valid point. Adding a back stab was a last minute idea and I didnt have two identical outlets in my junk box. The different plastic could certainly have made a significant difference, or even internal construction of the outlet.

    • @nicksz8909
      @nicksz8909 2 роки тому +1

      @@ElectromagneticVideos Thanks for the reply! I think the testing that I mentioned would really help to show whether it is the back stab or just cheap outlets that are the problem in normal conditions.

    • @ElectromagneticVideos
      @ElectromagneticVideos  2 роки тому

      @@nicksz8909 Also might be interesting to see if SPEC outlets do much better than regular ones or if its that they are more mechanically robust for repeated plug insertions.
      A number of people have told a few stories how they had to replace all the outlets in new installs after the outlets started randomly failing months later. Others have told of how problems surfaced years later. To me, that means more than any quick informal test I might do here.

  • @tenthdimension9836
    @tenthdimension9836 Рік тому +1

    I would have liked to have seen a yellow wire nut that wasn't pre-twisted and would have liked to have seen the screw down outlet on the 12 gauge wire. Oh and the use of an infrared thermometer would have been interesting.

    • @ElectromagneticVideos
      @ElectromagneticVideos  Рік тому

      All great suggestions, particularity since I ended up getting an IR camera used in some of the later videos. So it would certainly be worth doing again sometime in a slightly better way!

  • @MichaelNatrin
    @MichaelNatrin Рік тому +1

    Thanks for sharing this!

  • @syntaxerorr
    @syntaxerorr Рік тому +1

    Isn't the idea connector and the wago essentially the same thing as backstabing the outlet? It's just a thin piece of metal that slightly cuts into the wire.

    • @ElectromagneticVideos
      @ElectromagneticVideos  Рік тому

      The wago has a lever to lock the wire in, but the Ideal seems like the backstab outlet as you suggest. What odd is how much poorer the backstab outlet is.

  • @daveschreiber9587
    @daveschreiber9587 2 роки тому +3

    With current flowing through those bare wires you are able to touch them without getting a shock. Is that because the wire is a better path to follow than your hand?

    • @ElectromagneticVideos
      @ElectromagneticVideos  2 роки тому +5

      Its actually because it is low voltage. Since the wire is shorted at the end with the wire nut, it has very low resistance, so only a 1 or 2 volts is needed to drive the large current. So this makes the test quite safe voltage-wise while still making the wire experience the various degrees of overcurrent. If we had a huge 120V load at the end instead of the wire-nut short and used 120V to drive the same current, we would get the same heating for the same current but it would not be safe to touch.

    • @lorddissy
      @lorddissy 2 роки тому +3

      ​@@ElectromagneticVideos It would be wonderful if you'd consider making a video on this subject! I'm (very) new to your channel and so haven't made it too far back through your videos, so apologies if one already exists.
      I had the same question in my mind as Dave asked. That so few people commented on this, the further I had to scroll to find even this one, the more I thought this had to be a stupid question. None the less it has still been slightly unnerving while watching your test videos!

    • @ElectromagneticVideos
      @ElectromagneticVideos  2 роки тому +1

      @@lorddissy So the couple of recent videos that got popular actually are a poor representation of the rest of the content - which is a much more general smattering of technical things that I find interesting. So you may be disappointed if you look back hoping to find similar stuff.
      The reason I can touch them is the voltage is really low: 1 or 2 volts! That is the voltage drop you get along a conductor when it carries power from the breaker panel to the load because the conductor is not a perfect conductor, but has a little resistance. So at the panel you might have 120V and maybe at the plug of a big heater it is only 118V. 2V is lost along the wire when the wire carries 10A (of course the are just illustrative numbers - they vary based on wire length etc). So that 2V at 10A means 20W is dissipated as heat in the wire. As long as there is 10A flowing it doesnt matter what the actual wire to wire voltage is - almost zero in this case or 120V for a real load: the heating is the same. Of course how much energy gets to the load does depened on the line to line voltage. In our case the voltage across the load (the wire nut connection) is essentially zero so its 0 watts. If we has a real 120V load 10A current would mean about 118V x 10A = 1180W would be delivered to the load, but the wore would still dissipate 20W. If I had done it that way I sure wouldnt be touching the wires! I might do an explanation video since many people have asked variations of the question. Hope this hastily written explanation has helped!

    • @ElectromagneticVideos
      @ElectromagneticVideos  2 роки тому

      See my answer below!

    • @deang5622
      @deang5622 2 роки тому

      It doesn't matter about current flowing through the cables, that doesn't determine whether you get an electric shock or not. What does is: the source voltage, the source resistance, the wire resistance, your body's resistance.

  • @Gumby1974
    @Gumby1974 11 місяців тому +1

    I think it would be interesting to see poor usage of wire nuts. Maybe pre twist, no twist, poor twist, stranded and solid, etc. Great videos!

    • @ElectromagneticVideos
      @ElectromagneticVideos  11 місяців тому

      Thanks! I might just do that when I do some more wago tests. Interesting thing is that there seems to be significant disagreement as to whether wire should be pre-twisted when using wire nuts. I'm in the pre-twist camp....

  • @Songwriter376
    @Songwriter376 Рік тому

    It would be interesting to do a milliohm resistance reading on each individual connector. The ones with the highest reading would get the hottest and the ones I would not use but then again, who would draw 50 or 100 A of service residentially?

    • @ElectromagneticVideos
      @ElectromagneticVideos  Рік тому

      I could do that with a voltmeter across each connector and use the voltage and (known) current to get the milliohms. As far as who would draw 50A or more, the purpose was really to see how how big the margin of safety is - its actually quite impressive given this sort of wiring is typically used for 15A max. Having said that, things like motors can draw many times (I have seen 6x) their running current for a few seconds while starting up so for things that I would prefer to have components that handle larger currents well.

  • @JohnThomas-lq5qp
    @JohnThomas-lq5qp 2 роки тому +1

    Would recommend using a FLIR camera or even a cheap Hanh held temperature gun to check temperatures. The one hole lug that connects the #14 to stab in st rear of receptacle is only rated for one wire. If you have two wires inspectors will tell you to use a two hole lug.

    • @ElectromagneticVideos
      @ElectromagneticVideos  2 роки тому +1

      Good point about the FLIR camera - I did get one for my cell phone which I used for later videos such as the Knob and Tube one. I will have op repeat this one sometime with the camera.

  • @rotate85
    @rotate85 2 роки тому +1

    Can you make a video going over the power supply you're using to do this test. Thanks.

  • @troyb2208
    @troyb2208 2 роки тому

    How are you touching the bare wire without get shocked?

    • @ElectromagneticVideos
      @ElectromagneticVideos  2 роки тому

      The voltage is low: 10V or less. Thats because the circuit is essentially a short and you need a low voltage to limit the current to reasonable values that would be flowing under normal load conditions.

  • @vincentrobinette1507
    @vincentrobinette1507 2 роки тому +3

    I wired a finished basement using the push-in connectors on the outlets. I will NEVER make that mistake again! My outlets, were rated for #12 gauge wire, rather than the #14 gauge, but, that didn't make it any better. ALWAYS use the screws, and wrap the wire around the screws. You want the contact area between the wire and the pads to match or exceed the cross section area of the wire itself, to ensure that there is no more temperature rise at the connection point, than in the wire itself. That will guarantee safety when plugging in high amperage loads, like hair driers, space heaters, toasters/toaster ovens, or even large vacuum cleaners.

    • @fretlon
      @fretlon 2 роки тому

      I wired my basement the same way about 17 years ago. Since then I've replaced every receptacle and terminated on the screws. I ran into several outlets wired with the push in connections that would lose power when you moved or torqued on the plug. Several would lose it with only slight pressure or would require you to move it around to get power at all. I had a couple where you could even hear slight arcing in them when that happened. I finally decided I didn't want my house to burn down so I replaced them all and terminated them on the screws. No problems since then.

    • @ElectromagneticVideos
      @ElectromagneticVideos  2 роки тому

      So how did the problems you must have had appear? Did the occasional outlet burn up when a high load device was plugged it? Or did they just randomly go bad?

    • @WesB1972
      @WesB1972 2 роки тому +1

      @@ElectromagneticVideos My problem with push in connections on outlets and switches was random open circuits. This resulted in call backs to troubleshoot and correct. I quit using push in devices 40 years ago,

    • @ElectromagneticVideos
      @ElectromagneticVideos  2 роки тому

      @@WesB1972 Gee that must have been costly and frustrating! I cant believe they still have that feature - I have not seen a single comment here - or anywhere else - where anyone says they are any good!

  • @dpav7994
    @dpav7994 2 роки тому

    How are you pumping 70 amps through a bare copper wire and touching it and poking it without dying? Is it just because you're hoping you're less of a short circuit to the ground than that wire already has?

    • @ElectromagneticVideos
      @ElectromagneticVideos  2 роки тому +1

      Because its essentially a short, the voltage needed to generate 70 Amps is only in the range of 1 to 2 volts. This is the same as the voltage drop that occur along the wire or across the connections in normal use, although you would hope the current never gets close to that value. Like the neutral wire in a real situation, the wire here is at about ground potential. I sure wouldn't be touching it if it was at 120v like the "live" wire in a real situation.

  • @nudebaboon4874
    @nudebaboon4874 2 роки тому +1

    Another excellent case of old stuff being better than the new shite!

  • @jack8356
    @jack8356 2 роки тому +1

    Great video

  • @miker648
    @miker648 2 роки тому

    What is the point? They are all acceptable at the rated amperage.

  • @corviswood
    @corviswood 2 роки тому +2

    The heating of the 14ga wires by resistance cannot be distinguished from the push in backwire connection. Better comparison would be all 14ga and wire lenths equal.
    The wires are supposed to twist together from torque of the nut. Normal circuit breakers do not go that much higher than rating on resistive loads.

    • @ReubenHorner
      @ReubenHorner 2 роки тому

      Current is the same through a whole circuit. Same heating on each end

    • @corviswood
      @corviswood 2 роки тому

      @@ReubenHorner Heat is caused by resistance, smaller wire equals higher resistance.

  • @Satchmoeddie
    @Satchmoeddie Рік тому

    #12 AWG copper will melt open in a renewable link fuse at 235 Amps. #14 AWG copper melts open at about 166 amps in a renewable link fuse. These wire link fuses went out of use about 75 or 80 years ago. They were quite popular in the 1900s through the end of WWII.

    • @ElectromagneticVideos
      @ElectromagneticVideos  Рік тому

      I have heard about fuses like that. Interesting to hear the details. I do remember fuses that had a replaceable thin wire between some ceramic and an asbestos pad for household branch circuits in some 240V countries. I guess in the old days that was the simplest way to do things.

  • @Darenator1
    @Darenator1 Рік тому +2

    At 9:13 you state that both stick in and screw terminal receptacles are rated at 15A. That is not correct. A 15A receptacle is rated to be on a 20A circuit as far as pass thru current for the screw terminals. That is part of the code and will be the case if it has a UL listing.

    • @ElectromagneticVideos
      @ElectromagneticVideos  Рік тому

      I think you have hit on one of the few differences between US and Canadian electric codes. Last time I looked, up here in Canada you cant put a 15A receptacle on a 20A circuit. Not sure if its different in the US, but on that particular stick in receptacle it specifically said only#14 wire for the stick in connectors.

  • @MrNebRebew
    @MrNebRebew 2 роки тому +5

    Great tests! Addition of thermal imaging camera would be interesting.

  • @montanadan2524
    @montanadan2524 Рік тому

    So the power source was DC correct?

    • @ElectromagneticVideos
      @ElectromagneticVideos  Рік тому

      Its AC - its a vintage welder from the days before cheap high current rectifiers.

    • @montanadan2524
      @montanadan2524 Рік тому

      @@ElectromagneticVideos Variable current, constant voltage?

    • @ElectromagneticVideos
      @ElectromagneticVideos  Рік тому

      @@montanadan2524 Welders are more along the lines of a poorly regulated constant current power supply, at least the old non-electronic ones. Essentially they try and keep the current somewhat constant with the limits of their output voltage range. So my set up is a variac (variable voltage transformer) powering the welder. By adjusting the voltage to the welder I have much finer control of the output current which is roughly proportional to voltage going into the welder. The welder serves as step down transformer so I get lower voltage at higher current that would be possible with the variac by itself. But because of the constant current source nature of the welder, it also makes things easier when the the resistance of the device being tested changes - normally that would result in wild current swings, but with the welder the current swings are less extreme . This was more important for some other tests I did with 14/2 in walls etc. When the insulation melts and the 14/2 shorts closer to the welder, in spite of the change in resistance of the cable the current doesn't go crazy.

    • @montanadan2524
      @montanadan2524 Рік тому

      @@ElectromagneticVideos Variac tells me all I need to know along with you touching the conductors to feel for heat.

    • @ElectromagneticVideos
      @ElectromagneticVideos  Рік тому

      @@montanadan2524 And just to make it clear - the low voltage high current test circuit is effective isolated from the AC supply. So if you decide to try something like this be sure your not touching anything like live 120V!

  • @MrRene1968
    @MrRene1968 Рік тому

    Thank you, very informational.

  • @blackdragonx1186
    @blackdragonx1186 2 роки тому

    ive been upgrading switches to smart switches for my buddy. for making the connections im using the wago style, specifically due to the smart switches using stranded wire. otherwise ill use a wirenut, unless its in a low current application that will need to be taken down for service

  • @anthonyglund
    @anthonyglund 2 роки тому

    Are you able to touch the bare wire and connections since the voltage is so low there is very little potential to be shocked?

    • @ElectromagneticVideos
      @ElectromagneticVideos  2 роки тому

      Exactly! It it was 120V I wouldn't be touching them!

    • @deang5622
      @deang5622 2 роки тому

      Anything over 50 volts AC is enough to kill.

  • @martinb.770
    @martinb.770 2 роки тому

    I'd be interested in measuring the the connection resistance of each of these BEFORE and AFTER the test. It seems, the yellow nut kind of hard-soldiered itself?
    Does it make a difference how hard you fasten the nuts/screws or even clean the copper surface before attaching?
    How long/many turns make a difference in the nuts?
    Also, what about conventional screw terminals?
    And for comparison: Where is the limit of soldiered connections?

    • @ElectromagneticVideos
      @ElectromagneticVideos  2 роки тому +1

      I should do a more controlled test like that. Maybe when I get FLIR camera!

  • @Mooff2
    @Mooff2 Рік тому

    It looks like the wires below the yellow wire nut are touching, which would reduce the current load on the actual wire nut. Also, the wires in a wire nut should not be twisted. They will twist themselves if you install it with proper technique.

  • @robertcartledge8036
    @robertcartledge8036 2 роки тому

    Back in the early 70s when the backstabbed outlets first arrived and would except number 12 wire my Company had me wire an entire apartment building with them. Two months later I was back replacing every single outlet.

    • @ElectromagneticVideos
      @ElectromagneticVideos  2 роки тому

      Besides being frustrating, it must have been an enormous cost to the company. I can believe they still equip outlets with them.

    • @Sparky-ww5re
      @Sparky-ww5re 2 роки тому

      We're you using copper or aluminum. If aluminum, was it the old technology aka 1350 AL, or the then new technology aka 8000 AL ?? My understanding is many homes, apartments and especially cheap double wide mobile homes used aluminum wiring from about the mid 60s, to the early to mid 70s due to the copper shortage caused by the post WWII housing boom and the Vietnam War.

    • @ElectromagneticVideos
      @ElectromagneticVideos  2 роки тому

      @@Sparky-ww5re Never occurred to me that different alloys might have been used. As far as I know it was very common here (Ontario, Canada) at that time - I didn't know there was a copper shortage - that sure explains the the switch to Aluminum.

  • @stuckinmygarage6220
    @stuckinmygarage6220 2 роки тому +3

    Makes me think of sticking with wire nuts, pre-twisting good idea

  • @demofilm
    @demofilm Рік тому +1

    The advantage of using a wago 222 is you can use lose wire and solid wire in one connector.

    • @ElectromagneticVideos
      @ElectromagneticVideos  Рік тому +1

      I'm guessing you mean connect stranded and solid wire? Yes - wire nuts are not great for that!

    • @demofilm
      @demofilm Рік тому +1

      @@ElectromagneticVideos indeed that's what I meant.
      I use them instead of those awful sctoch blocks in automotive things.
      anyways thanks for the informative videos

    • @ElectromagneticVideos
      @ElectromagneticVideos  Рік тому

      @@demofilm So they work well for automotive? Thats interesting and says a lot for them. With all the heat and vibration, anything that can hold up in a vehicle is impressive.

    • @demofilm
      @demofilm Рік тому +1

      @@ElectromagneticVideos in my opinion yes! you have more chance of breaking a wire instead of the connection losing grip.
      i am not saying everybody should do so, it is your own risk. but radio's installed with those connectors insted of the advised spade connectors held up longer without any problem. and are less likely to have bare ends sticking out and creating shorts.
      only drawbacks for me, they are bigger and more expensive.

    • @ElectromagneticVideos
      @ElectromagneticVideos  Рік тому

      @@demofilm Interesting - one of my future projects is to build out a camper van and have been wondering about connectors and cables being subjected to vibration. What is you experience regarding cables? How to you secure them to make sure they don't rub against something and eventually short?

  • @F117nghthawk
    @F117nghthawk 2 роки тому +1

    It is a nice setup however due to the 14 gauge wire on that back stab outlets, that 14 gauge wire will heat up significantly quicker therefore causing that outlet to fail prematurely compared to the other terminations. You will have to redo the experiments with all 14 or all 12 gauge wire.

    • @ElectromagneticVideos
      @ElectromagneticVideos  2 роки тому

      yes - its not an apples to apples comparison. The reason for the #14 is the back stab outlet specifically required #14 in the instructions.

  • @willie9899
    @willie9899 2 роки тому +1

    This would be really cool with even a cheap thermal camera. Also, what about trying this again with a simple bat of fiberglass insulation layed on top, or better yet, underneath? Would give it more of a "real world, in wall" result.

    • @ElectromagneticVideos
      @ElectromagneticVideos  2 роки тому

      I'm going to look into thermal camera! But I did do a fiberglass test that I posted today. Enjoy: ua-cam.com/video/Df7bAEdIILI/v-deo.html

    • @willie9899
      @willie9899 2 роки тому

      @@ElectromagneticVideos already watched it. keep up the informative content!

  • @hippo-potamus
    @hippo-potamus 2 роки тому +1

    Great content! Subscribed.

  • @Risterkin90
    @Risterkin90 2 роки тому

    I work in maintenance and I was having a problem with a flourescent lamp fixture .
    I replaced the ballast using wegos and the fixture wouldn't turn on . I undid all the wegos then put them back and tried
    it again. Still wouldn't turn on . I called up an electrician for the building and I told him about the problem and he suggested using wire nuts instead of the wegos. I flipped the switch after using the wire nuts. It came on like it was supposed to.

    • @ElectromagneticVideos
      @ElectromagneticVideos  2 роки тому

      I always find in fascinating to hear real world accounts like yours. I have seen ballasts with very thin wires. Maybe they were just too thin for the wego to clamp to?

  • @gackaret
    @gackaret Рік тому

    FLIR? So we can see the hot spots?

    • @ElectromagneticVideos
      @ElectromagneticVideos  Рік тому

      I did get one a few video later where you can see the thermal images of cable in various types of wall insulation.

  • @themonkeydrunken
    @themonkeydrunken Рік тому

    The yellow wire nut is doing nothing, since the wires are touching leading up to it. Also, why not try this with an IR imager?

  • @MrKen59
    @MrKen59 2 роки тому +2

    Very timely presentation as I was curious how the wagos work. Since you are becoming the official UA-cam wire burner, might need to invest in a flir camera. Thanks so much !! Ken

    • @ElectromagneticVideos
      @ElectromagneticVideos  2 роки тому +2

      I had never used them before, so it was interesting to see. Some youtubers seem to be proclaiming them the best thing since sliced bread. I'm less convinced of that now but they do fill a certain niche. Glad you liked the video. It actually might be fun to have a flir camera - I'll have to see if I can find a flir imager that I can record the data stream directory from rather than the common integrated sensor/display units. An I'm honored to be "the official UA-cam wire burner". I'm really amazed how the 14/2 video really took off - who would have thought!

    • @MrKen59
      @MrKen59 2 роки тому +2

      @@ElectromagneticVideos I agree the wire nut is by far the most reliable, but those wagos as sweet when you have to swap a wire. I’ve tried the ideal, and I found you can remove the wire - However, the wire does need to be a fresh strip. I was amazed at how much current you could push before bad things happened. I’d love to see the heat map of those little connectors at higher current. Anyhow, they are UL listed so I suspect someone, somewhere tested all this. You my friend are very good at talking this through and appreciate the video.

    • @ElectromagneticVideos
      @ElectromagneticVideos  2 роки тому +1

      @@MrKen59 Your right - you cant beat the wago if you have to change something. But I think for any high power stuff wire nuts are it. I couldn't agree with you more about how well they all survived such over-current abuse. really impressive. By the way - I really appreciate your feedback about my talking - I have been wondering if I was anywhere close to a good balance between saying too much or too little .

  • @farmerjim-fat-man-do
    @farmerjim-fat-man-do 2 роки тому +6

    Test method is not the best with connectors in series and with different gauge conductors on each end of the circuit. Each connector will have a different resistance and the 14 ga wire has more resistance than the 12 ga., essentially becoming a resistor itself. In a series circuit, all resistance is additive. Given a constant circuit current, the voltage drop across each connector will vary. In this test, the meter was set up to read voltage drop across the combination of connectors. At 20amps there was .35 volts combined loss but hard to say which connector had the highest voltage drop. Would of been better to test each connector individually with same voltage and amperage (e.g. 120v @20amps) while measuring voltage drop across the connector . Using ohms law(R=v/I), the resistance through the connection can be calculated. Highest resistance connection will produce the most heat and will most likely fail the quickest. There are other variables that will determine failure time beyond the scope of this response but you could continue with destructive testing by holding same voltage and cranking up the current until circuit opens while timing. I would bet the twist on connector (marrette) will carry the highest load the longest.

  • @ken830
    @ken830 Рік тому +2

    When the wires are twisted together properly, the wire nut is essentially not part of the equation at all.

    • @ElectromagneticVideos
      @ElectromagneticVideos  Рік тому +1

      Good point. Having said that, they still provide some mechanical strength and insulation.

    • @ken830
      @ken830 Рік тому +2

      @@ElectromagneticVideos Yup. That's the idea. Insulation and keeping the wires from untwisting. I really like the Wago myself though. Very convenient especially in tight spaces and for future reworking. Untwisting and retwisting wires fatigues them and not supposed to reuse wire nuts. Also much harder to get wire nuts right and tight at 3 or more conductors. Wago is nearly fool proof.

    • @ElectromagneticVideos
      @ElectromagneticVideos  Рік тому +1

      @@ken830 I would sure use them for connecting things like ceiling lamps with thin stranded wire to solid wire in the junction box. I was a bit dubious about them at high current loads but to be fair they did hold up to past the rated current.

  • @vriddle79
    @vriddle79 2 роки тому

    Please get a contactless infrared thermometer :)

  • @xxjusxstarxx
    @xxjusxstarxx 2 роки тому

    Wago looks like it failed electrically before the ideal connection, even though the plastic melted first, the wago seemed to be the one that threw sparks

    • @ElectromagneticVideos
      @ElectromagneticVideos  2 роки тому +1

      Yeah - but in fairness to both of them they only began to show signs of failure way beyond what they normally ever should be subjected to. Now that I have a IR camera at some time I will repeat the test and see which gets hot first.

  • @hotratz69
    @hotratz69 Рік тому

    Voltage drop across each separate connection will tell the story. Or an Infrared imager.

  • @sportsonwheelss
    @sportsonwheelss Рік тому

    why not use 14 gauges for all the connectors to be fair?

  • @JavonDevv9000
    @JavonDevv9000 2 роки тому +1

    Anyone notice the wires are a bit dark at the end of all that torture

    • @ElectromagneticVideos
      @ElectromagneticVideos  2 роки тому +1

      Good observation! The heat causes a thin oxide layer to form on the outer surface of the copper making it look darker. Same thing happens to exposed copper that is not overloaded over years of gradual oxidation. Interesting thing about the oxide layer - it actually can be used as a semiconductor rectifier and devices made with copper oxide were used in application like battery chargers before modern high-current semiconductors were mass produced.
      By the way - saw your vacuum motor burn up video - from my own experience I'll bet that gave off some noxious fumes!

  • @aomanchutube
    @aomanchutube 2 роки тому

    I always thought the wago connector was just shit compared to the standard twist wire nut. It's really impressive to see that it does survive to the same power that the screw connection does.

    • @ElectromagneticVideos
      @ElectromagneticVideos  2 роки тому

      I was impressed how well they did and certainly did well at all rated currents. What I wonder is how decades of age may alter their internal mechanics. Some people have said they use them for low power lamps and I can see that. For something like an induction motor with high startup current surges, I would stick to wire nuts!

    • @deang5622
      @deang5622 2 роки тому

      Same current, not power. Let's get the parameters right.

  • @MG-nz6bx
    @MG-nz6bx 2 роки тому +2

    the whole test is absolutely moot the second you take the consistency of the wire out of the equation. do the same exact test across the board with all 14 gauge wire, and then you can have some non-biased results.