  • how to hook up a harbor fright v twin compressor head to a compressor that gone bad. how to deal with the crazy wackado fitting no one can find. the good news the actual heads are standard 3/4 inch pluming parts and you can

КОМЕНТАРІ • 43

  • @maddawg1072
    @maddawg1072  7 місяців тому +1

    Half a decade later still humdinging along just fine to all the smooth monkees complaining about cooling fins and copper blah blah blah.
    Live a little learn alot 5 years later still got.
    Lol🎉😂😊

  • @beckyschwantes5287
    @beckyschwantes5287 3 роки тому +8

    That pipe you removed was an inter cooler circuit. Why remove?

  • @anitaschvitz9749
    @anitaschvitz9749 2 роки тому +3

    Why didn't you buy American? Then you wouldn't have to be put out about how people in another country do things different.

  • @heathhill7802
    @heathhill7802 Рік тому +2

    Hard piping will cut the life cycles . The heads need to freely move ,coppers used for heat -pipe expansion and contraction.
    It's works that way . Don't overthink it

  • @jeffreyleake3523
    @jeffreyleake3523 3 роки тому +7

    Yeah I had no problem at all finding a 3/4 copper fitting to fit without modifying anything and though I like your tip about removing the fittings from the cylinder head and putting the standard pipe fittings in I personally would not do away with the finned cross pipe that comes with the pump because though it may work just fine the way you have it the finned cross pipe that comes on it is to reduce heat and to reduce the moisture that builds up and goes into your tank now how much of a difference it may make I don’t know and can’t say if it is enough of a difference to even be worth the hassle of making it work with it but in my own personal opinion if keeping moisture out of your air supply is something that you want then regardless of how much of difference it makes I would keep that but again that is personal opinion though regardless of the brand or where it was manufactured at every duel head compressor pump I have ever seen has the same finned line for reducing heat and that alone would be enough to tell me that it must make some kind of measurable difference

    • @davidrule1335
      @davidrule1335 Рік тому

      Good point. Dude is an idiot. Hard piping that would e difficult. you might have 2 threads in length to play with. Even with that said. Once you fit it up if the union isn't seated, Tightening it op will seat it and pull the heads together, plus carry the vibrations with it. Numb Nut probably use it as a lifting nut.

    • @maddawg1072
      @maddawg1072  7 місяців тому +1

      5 years on..still going strong insignificant worrys
      Use heavy to paint cars sand body work run high volume are tools no significant moisture in take I have a dryer on my outlet line for keeping moisture out of paint guns
      No problems a half a decade in its pride for itself 100 times over it could total screw the pooch tommorow and I would go get another one and set it up on my tank exactly the same way

  • @ProfessorDIY
    @ProfessorDIY 5 місяців тому

    why in the world would you change a design that works?

  • @kvechannel
    @kvechannel 9 місяців тому +1

    That solid tube between cylinders will expand due to heat and will break the cylinder neck

    • @maddawg1072
      @maddawg1072  9 місяців тому

      Well I'll let ya know when that happens seeing it's been like this for YEARS I'm not to worried to be honest.

  • @JCC1256
    @JCC1256 5 років тому +7

    I just cut the flare off and a regular 3/4 npt fit right on.

    • @phiksit
      @phiksit 3 роки тому +1

      Yeah, if you get the pump with the flare connection the treads are pretty close to 3/4" npt. His had compression fitting thread and those are no where near pipe thread size.

  • @ikstrucking3289
    @ikstrucking3289 3 роки тому +5

    You did totally the same circuit, but worse, no cooling! What was the point? The fins were scratching your eyes? If so then there was a reson to redo it your way, but that is the only reason. FYI, the HF way is a better way.
    I can't believe you did what you did, there was no physics justification of any kind to do what you did!!!

  • @harryconover289
    @harryconover289 3 роки тому +3

    You have removed the cooler believe they put no unexpected parts you cannot do with out

  • @philliphall5198
    @philliphall5198 Рік тому +1

    There very good and I change oil every year with out much use
    Fixing to go to every 6 months because I’m using it every day for mower repairs

  • @ameenalshwaiyat7006
    @ameenalshwaiyat7006 2 роки тому +2

    Hill billy engineering

  • @britdecker6006
    @britdecker6006 29 днів тому

    Helpful video, thanks.

  • @jamilakram2874
    @jamilakram2874 5 років тому +3

    Hello dear. I want to inquire about the per anum liters we can get from checkered giants. Are they same like as other rabbits or have some different routine? I am from pakistan. Will they survive there and how many clutches we can get yearly from checkered giant rabbits.

  • @ceesteven
    @ceesteven 4 місяці тому

    Good tips. Thanks. May God Bless.

  • @drumminjeff71
    @drumminjeff71 4 роки тому +3

    Can you run the pressure up over a hundred pounds? I really need at least 125psi

  • @dhollm
    @dhollm 3 роки тому +1

    I don't think the loss of the finned tube is as significant as it might seem. Both heads are the same, as far as I can see, so this is not an intercooler (between stages) instead it just cools the air from *one* of the two heads. (Having a second finned tube between the tee & the tank itself would be an improvement). While reducing temperature should mean that a somewhat larger mass of air will be stored it will not reduce the moisture content (moisture has nowhere else to go but into the tank), so that is a non-issue.

  • @MegaRiffraff
    @MegaRiffraff 3 роки тому +1

    That crazy nut is called Japanese industrial metric , I had a Hydrolic hose company put a line on it for mine they charged $25.00 , but it was on the correct side for my horizontal 80 gal tank , so didn't have to be very long .

  • @gynat5968
    @gynat5968 3 роки тому +4

    "Thaiwapaneese" ... Baaahahahaha

  • @Clifford270
    @Clifford270 3 роки тому +1

    How long did it take to go from 0 to 100 psi?

  • @murhafsukkar9555
    @murhafsukkar9555 4 роки тому +4

    I have the same compressor and to best of my knowledge the fins cool down 160% comparing to cooper . Now if you’re running steel pipe l, you should pray for your safety .
    Always check the temperature of the pipes and fittings before deciding to make it this way

    • @maddawg1072
      @maddawg1072  4 роки тому +2

      Been running to this day like this just fine been a few years I think if she was going to give up the ghost... the spirits would have left a long time ago. Thanks for your opinion... but words with out proof of concept are just that... opinion based on presumption. Have a great day 😀

    • @charlesshoemaker9290
      @charlesshoemaker9290 3 роки тому +6

      @@maddawg1072 use a 3/4 copper hot water tank flex line it screws right on I have used it for 9 years on another compresser

    • @davidortega7957
      @davidortega7957 3 роки тому +2

      Muraf sukkar- I HAVE THE SAME SET UP (STEEL WATER PIPE) FOR OVER A YEAR,HAVE NO ISSUES, IM A TRAILER MECHANIC, SO I USE MY 60 GALLON COMPRESSOR 5 DAYS A WEEK
      ALL DAY,WITH 5 HP HARBORFREIGHT HEAD PUMP, BY THE WAY, MY COMPTESSOR IS SET UP TO 190 PSI AND AS I SAID WORKS LIKE A CHAMP !!!

  • @kacperbryniarski8009
    @kacperbryniarski8009 3 роки тому

    Hey what you think about polish this pipes inside? I have the same compressor😃

  • @Mbice
    @Mbice 3 роки тому

    So it doesn't matter which side you use for the discharge outlet.

    • @Benbear2022
      @Benbear2022 Рік тому +1

      Not on this since it is a two cylinder single stage pump. If this was a two stage compressor pump then it would matter, but it is not.

  • @faisalfaixal2376
    @faisalfaixal2376 3 роки тому

    what connection of pipes im confused

  • @hey96779
    @hey96779 2 роки тому

    🥓🐷🥩

  • @vegitoblue7908
    @vegitoblue7908 4 роки тому

    Motor pulley size please.?

    • @williamallen7836
      @williamallen7836 3 роки тому +1

      Pully size will depend on the RPM of your motor. The manual has the very simple formula to figured the pully size you need to not exceed it's designed operating RPM.

  • @mahendarkurikuri7970
    @mahendarkurikuri7970 4 роки тому

    Kay pric h

  • @bashinnehall7090
    @bashinnehall7090 3 роки тому

    Well, I done the same thing he did. I have an aftercooler on my setup. I also noticed the inside diameter of the cooling tube Finn is way smaller then 3/4".
    Go copper if you don't have a aftercooler.

  • @AnthonyCelata
    @AnthonyCelata Рік тому

    Damn you got a 5HP now they only have 3....