Powering My Home With A Wen 3800 Inverter Generator

Поділитися
Вставка
  • Опубліковано 26 вер 2022
  • Using the WEN 3800 Inverter Generator to power my home. Needed equipment found at Amazon below.
    Interlock Kit at Amazon
    www.amazon.com...
    Generator Inlet Box at Amazon
    www.amazon.com...
    30amp to 50amp adaptor at Amazon
    www.amazon.com...
  • Навчання та стиль

КОМЕНТАРІ • 38

  • @spacecoastz4026
    @spacecoastz4026 Рік тому +10

    What you are not explaining, which honestly is one of the most important points, is that you are taking a 120v generator output, and splitting that feed, which is feeding both legs of your panel 120v single phase. In turn, all 120v house circuits will then work...but also none of the 240v would work...which is fine in most cases.
    I would suggest a few changes in your start-up process. Turn off all 240v breakers, turn off all refrigerators and electronics breakers, and keep the generator breaker off until the generator is up and running. Then turn on the generator breaker and then the refrigerator breakers. Keep all 240v breakers off until the generator is removed and normal power restored. Don't crank up the generator with live circuits that will be under load.

  • @jemf
    @jemf Рік тому +15

    Hi,I’m not an expert but I think you need to first start the generator, let it warm and stabilize and only after that go to your panel and start loading it one circuit at a time. I have a smaller generator but it can handle all my essentials

    • @pinkiepie1656
      @pinkiepie1656 Рік тому +5

      Correct. It should be started and warmed up a few minutes before flipping the generator breaker.

    • @weirdowolfstudio5409
      @weirdowolfstudio5409 3 місяці тому

      @@pinkiepie1656it’s loud

  • @GH-wt7ww
    @GH-wt7ww Рік тому

    Just received my WEN 3800 inverter generator. I'm looking at fuel conversion kits for natural gas for a endless fuel source. Natural gas has never let me down during outages. You are doing exactly what I've been doing only power necessities. Clean and simple install nice work.

  • @solden49
    @solden49 Рік тому +2

    This is an absolutely awesome video. You have given me a great idea. I have two of the wen 2250s with the parallel kit. This could be a good setup 👌

  • @8894larry
    @8894larry Рік тому +8

    You need to tell your viewers that that generator only puts out 120VAC! You have a 50/2 pole breaker but you can only put one leg from the generator into it. This means only one phase of your panel is energized! All the breakers/ loads you want on need to be on that phase. Start generator, shed loads, turn off main & 50/2 pole on & turn on breakers. Good luck!

    • @LocozillaYT
      @LocozillaYT Рік тому +2

      I mean he made it pretty clear he wasnt/isn't a Electrician and also said to make sure to consult a Electrician if interested in doing it

    • @8894larry
      @8894larry Рік тому

      @@LocozillaYT Oh, well that makes his video very educational!

    • @mikek8229
      @mikek8229 Рік тому +4

      The 30 amp to 50 amp adapter he is using will energize both legs of his panel so he can use any 120 breaker. I know because I do this myself.

    • @xbleriot
      @xbleriot Рік тому

      Not clear how you can power a main panel that requires 240V with a generator that only has a 120V output.....

    • @joshlasceski
      @joshlasceski Рік тому

      @@xbleriot He is only powering 120V devices with this method.

  • @kenmatthews6476
    @kenmatthews6476 Рік тому

    Great video. FYI…the new WEN 3800 now comes with remote start/shut off. I sold my inverter like yours and miss it but will be buying the new version on the next sale.

    • @braburghfarm493
      @braburghfarm493  Рік тому

      Thanks for the info!

    • @Confusedsole86
      @Confusedsole86 Рік тому

      I've been looking for this. I can't find one with remote start and shut off.

  • @MrTmone2169
    @MrTmone2169 Рік тому +1

    For an average house need a 5000w generator to power the whole house. I have two 5000w, one for the house and one for my workshop.

  • @ghostofautumnwood6379
    @ghostofautumnwood6379 Рік тому +1

    Hi. Great video. Can you share a link to the longer power cord you used?

  • @thejournalist384
    @thejournalist384 9 місяців тому

    How much gas is needed typically for a full load ?

  • @reynaldotorres4349
    @reynaldotorres4349 Рік тому

    nice... question, how is that dog bone inside, it has a jumper in both hots?

  • @600tnbobp9
    @600tnbobp9 Рік тому +1

    I have purchased a slightly larger wen generator the 4500 W generator. These smaller generators aren’t like normal generators. They only put out 120 V. The much larger and noisier gasoline powered generators usually put out 240 V and 120 V. So my question is I see that you can power both sides of your electrical panel. I was wondering how the electrician wired your generator in to do that? I have my house set up With a larger 240 V 9400 W generator. It’ll power the whole house no problem, everything all at the same time but boy is it noisy. I also would like to hook up my house the same way you did yours and just cut off the items I don’t need , and have it a lot quieter. So if you could reply back and give me some idea how you could split off 120 V generator to power both sides of your electrical panel I would greatly appreciate it. Thanks Bob Phelan.

    • @spacecoastz4026
      @spacecoastz4026 Рік тому

      It's very simple. You wire the inlet power box as normal for 240V. You purchase a short converter cord (as shown in this video) that takes the generator 120v output and splits it into two separate 120v feeds. If you won't be needing any 240v circuits this is actually more efficient that running 240v and only using 120v circuits. The reason its more efficient is that you are only having to manage total load, rather than two individual loads (per leg). Hope that makes sense.

  • @alvincarterm4
    @alvincarterm4 10 місяців тому +2

    Any reason you didn’t just buy a 30 AMP intel box instead of the 50 AMP box? Wouldn’t that eliminate the adapter?
    Getting ready to do this and just wanted to know the reason. Could it be that you wanted the option to upgrade to a generator that requires 50 AMP?
    Also, is the circuit breaker you are using 30AMP or 50AMP?

    • @dieseldawg7132
      @dieseldawg7132 2 місяці тому +2

      Smart thing to do is obviously go bigger on the inlet you do this incase you need to run a 10000 plus generator to run the hvac system …. A 30 amp wouldn’t be able to start the a/c it’s common sense

  • @issameQ
    @issameQ 6 місяців тому

    The panel is 240 v and the generator is 120v. How did that workout?

    • @thomabb
      @thomabb 4 місяці тому

      I'm sure it didn't work out well. The two legs powered by the generator are in phase, so there will be no voltage across them. None of the electrical that requires 220v would work. A 30 amp RV outlet is only 110v single phase. To do this properly, he needs a generator with a 30 amp 220v outlet and cords that are not for RVs.

  • @jerry73j
    @jerry73j Рік тому

    Wen does have one with remote start 4500

    • @braburghfarm493
      @braburghfarm493  Рік тому

      That's what I've heard. Updated model has a few more features that I would love to have.

  • @wolfmanjack123
    @wolfmanjack123 Рік тому

    So what were you able to actually run with this generator? Most of your major circuits were turned off.

    • @braburghfarm493
      @braburghfarm493  Рік тому +2

      During our last outage I was able to run the circuits for both kitchen and garage fridges, septic pumps, all lights interior and exterior circuits, multiple TV's, and use of gas furnace. The one thing I didn't try, that I would like to experiment more with, is the electric hot water heater we've got. But, this is only a 30 amp Gen circuit, so wouldn't attempt with the rest of that load. Handled the rest without problems, and ran it in eco for a few days.

    • @wolfmanjack123
      @wolfmanjack123 Рік тому +1

      @@braburghfarm493 Thanks! Sounds like the perfect little generator that will handle your basic needs for an average power outage. Great video!

    • @alvincarterm4
      @alvincarterm4 10 місяців тому

      @@braburghfarm493​​⁠can you please answer my question. Ty

    • @thomabb
      @thomabb 4 місяці тому

      @@braburghfarm493Don't run anything on a double pole breaker with that setup.

  • @chriseast030691
    @chriseast030691 9 місяців тому +1

    You should never "Hot" start a generator. By that i mean start it with anything plugged in. Fail.

  • @dellwam7890
    @dellwam7890 8 місяців тому

    It’s way lowder than the Champion and predator inverter generators…

  • @vontrap6942
    @vontrap6942 10 місяців тому

    The big problem is this person talks soooo slowly it could be condensed to 3 seconds!!! Ffs

    • @issameQ
      @issameQ 6 місяців тому +1

      Wana control how he talks? 😂