How to read data from encoder by using PLC S7-300 FM350-1 high speed counter module part1

Поділитися
Вставка
  • Опубліковано 28 січ 2025

КОМЕНТАРІ • 39

  • @tauqiranwar5699
    @tauqiranwar5699 3 роки тому +1

    Thanks for video, Excellent. Make video to read Speed through FM module

  • @Salirbeber1
    @Salirbeber1 Рік тому

    Excelent video!! Thank you so much

  • @motormadman
    @motormadman 2 роки тому +1

    At about 31:00. Load 16 to DB1.DBD 12 will interfere with DB1.DBD14. Making it hard to reset value since DB1.DBD14 is for reseting. Write to DB1.DBB12 instead!

  • @РусланЖаныбеков-ч7з

    Thanks for the Video. It is very helpfull

  • @bachelorkitchentamil4330
    @bachelorkitchentamil4330 3 роки тому

    Super very useful amazing video thanks bro

  • @ebrahimmohammadpour4384
    @ebrahimmohammadpour4384 Рік тому

    Many thanks for the video ❤

  • @saragabtni3744
    @saragabtni3744 Рік тому +1

    merci pour le video mr , mais j'ai un Question s'il vous plait, est ce que on peut utilise the high speed avec plc 315 2pn/dp?

  • @jasonjesmislang8929
    @jasonjesmislang8929 3 роки тому +2

    Hi thanks for the video.
    Can you make video for encoder positioning. How to interface the on and off degree.

  • @ebrahimmohammadpour4384
    @ebrahimmohammadpour4384 Рік тому

    I have already used fc2 in my project, can I change the name for the new encoder ?

  • @achrafaqdim9002
    @achrafaqdim9002 2 роки тому

    hi I have an application using an incremental encoder to measure a length and make the cut to the specific length. i use this module but i have probleme with sumulation can you help me please ?

  • @janetawuah2535
    @janetawuah2535 3 роки тому

    Thanks for this video...but please, where do you connect the power supply to the PLC and where do you connect your laptop to the PLC....
    What are the use of the PN port and DP ports

  • @pradeepmourya9362
    @pradeepmourya9362 3 роки тому

    Nice video
    Can u please make video of FM 352 for absolute encoder

  • @tauqiranwar5699
    @tauqiranwar5699 3 роки тому +1

    If you choose 5V incremental, it gives different options than selecting 24V incremental encoder

    • @generaltechnologyknowledge5165
      @generaltechnologyknowledge5165  3 роки тому

      Yes it should be different

    • @tauqiranwar5699
      @tauqiranwar5699 3 роки тому +1

      @@generaltechnologyknowledge5165 brother, I have to count 5V single pulse...Can I use "A" only in monitoring or is it possible?

    • @generaltechnologyknowledge5165
      @generaltechnologyknowledge5165  3 роки тому

      @@tauqiranwar5699 Yes that correct,
      Please select to A possition

    • @tauqiranwar5699
      @tauqiranwar5699 3 роки тому

      @@generaltechnologyknowledge5165 thanks, when I select Operating mode @ continuous counting it gives SF, but when I use single counting it gets OK..

  • @keysansa
    @keysansa 2 роки тому +1

    The module worked with the old project.
    When loading a new one (the hardware has changed), the module gives an error "module without parameters".
    I did everything as in the video.
    Still the same error.

    • @generaltechnologyknowledge5165
      @generaltechnologyknowledge5165  2 роки тому

      Dear sir,
      Please check power supply 24VDC supply to module connect correctly or not?

    • @keysansa
      @keysansa 2 роки тому

      @@generaltechnologyknowledge5165 auxilary supply ok. If i disconnect, module says : "no supply"

    • @thomasb4422
      @thomasb4422 2 роки тому

      @Key Sansa were you able to fix your problem? I have the same problem

    • @keysansa
      @keysansa 2 роки тому +1

      @@thomasb4422 Yes. Disconnect the encoder and configure the module without it. After that, connect the encoder.

    • @keysansa
      @keysansa 2 роки тому

      @@thomasb4422 All connections with power off procedure

  • @shahaalom6891
    @shahaalom6891 3 роки тому +2

    How to use FM350 - 1 in TIA

  • @vorapobautomation9760
    @vorapobautomation9760 3 роки тому +1

    ใน TIA ทำยังไงครับ S7-1500

  • @vorapobautomation9760
    @vorapobautomation9760 3 роки тому

    How to do with S7-1500 ?

  • @tauqiranwar5699
    @tauqiranwar5699 3 роки тому +1

    Please let me know how to read speed through FM 350-1

    • @generaltechnologyknowledge5165
      @generaltechnologyknowledge5165  3 роки тому

      Dear sir,
      We can use the formula to calculate speed by using encoder.

    • @tauqiranwar5699
      @tauqiranwar5699 3 роки тому +2

      @@generaltechnologyknowledge5165 any clue about formula?

    • @generaltechnologyknowledge5165
      @generaltechnologyknowledge5165  3 роки тому

      @@tauqiranwar5699
      Please test with this
      Electrical speed=[[(Max Frequency response(kHz)*1000(Cycles/minutes)]/PPR]*60(Sec/minutes)
      Example: Max Frequency response=120kHz, PPR=25mm/0.01mm=2500PPR(if the required linear resolution is 10 microns (0.01 mm), and a screw with a 25 mm lead is used) then
      Electrical speed=[(120*1000)/2500]*60=48*60=2880rpm
      I hope it work.
      Thanks

    • @tauqiranwar5699
      @tauqiranwar5699 3 роки тому +1

      @@generaltechnologyknowledge5165 Thanks a lot...
      In FM350-1 (6ES7350-1AH03....the operating mode RPM measurement is available....is it also need for this latest FM 350-1..

    • @generaltechnologyknowledge5165
      @generaltechnologyknowledge5165  3 роки тому

      @@tauqiranwar5699 Yes sir