  • @dubbleA100
    @dubbleA100 8 місяців тому

    How many stages do you recommend for a 2 rotor and how many for a 3 rotor?
    Thanks for the info.

    • @mrenforcerengineering642
      @mrenforcerengineering642  7 місяців тому +1

      min 3 stages
      2 scavenge and 1 pressure
      20b 4 stage 3 scavenge and 1 pressure

  • @erikwahlstrom7826
    @erikwahlstrom7826 8 місяців тому

    Where do you recommend the oil cooler placement in all this plumbing.
    What about the magnet pickup which is normaly in the bottom of the OEM oil pan.

    • @mrenforcer
      @mrenforcer 8 місяців тому

      no magnetic plug. run inline filters or screens on the line to collect any material from oil pan