Vector group Dyn11 explanation in 25KVA distribution transformer | ocm creations

Поділитися
Вставка
  • Опубліковано 1 січ 2025

КОМЕНТАРІ • 31

  • @localmytube
    @localmytube 3 роки тому +3

    చాలా బాగుంది బ్రదర్

  • @u2vinay
    @u2vinay 4 роки тому +4

    Very clearly explained sir, thank you

  • @ramanavelaga5248
    @ramanavelaga5248 2 роки тому +1

    Superb sir👍👌👌🙏

  • @TajbabuShaik
    @TajbabuShaik 3 роки тому +1

    Super explanation bro

  • @durgabhavanipb
    @durgabhavanipb 3 роки тому +1

    Super sir,Where we can find more videos of ur channel like instragram

  • @satyaiahbyndla2404
    @satyaiahbyndla2404 3 роки тому +1

    HV LV ante yemiti explain please

  • @talariguruganesh9407
    @talariguruganesh9407 4 роки тому +1

    Super explained sirrr

  • @sridurgaspices3085
    @sridurgaspices3085 2 роки тому

    15kva transformer 20hp motre connect ??

  • @prashanthsadam9048
    @prashanthsadam9048 4 роки тому

    Anna మా area ki 3 15kva single phase transformers vunnaie 3phase motor connection cheyasaru ela? ఇంకొకటి అన్న 3 single phase transformers nundi 3 Street ki supply vellindi a transformers nundi 3 phase 1 neutral tisukunnaru ala tisukovachha a transformer neutral a transformer phase ke use cheyala

    • @PracticallyElectrical
      @PracticallyElectrical  4 роки тому +1

      1phase transformers Star connection chesthe neutral common ga vasthundi.we get 3phase supply from 1phase transformers by connecting delta at primary and star at secondary

  • @nagendravasi5468
    @nagendravasi5468 2 роки тому

    Sir VAGM 22relay calculatio please explain

  • @mouneshachari870
    @mouneshachari870 3 роки тому

    Gud..👍

  • @Sandhani-c
    @Sandhani-c 3 роки тому +2

    అన్న ఒక 25kva ట్రాన్స్ఫార్మర్ మీద ఎంత HP load వెయ్యవచ్చు

  • @prashanthsadam9048
    @prashanthsadam9048 4 роки тому +2

    Anna 1 phase 15kva transformer full load current 65A, 3phase 25kva transformer full load current 33.33Ams, కాబట్టి మనము 1 phase transformer 3 తీసుకొని ఎక్కువ 3 phase motors run cheychuga anna

    • @PracticallyElectrical
      @PracticallyElectrical  4 роки тому +2

      Yes but if u want to run 3phase motor you need to get 4phase supply from single phase transformers by making delta connection at primary side and star connection at secondary side. From 3phase transformer you can get ra ted line current from each phase..

  • @prashanthsadam9048
    @prashanthsadam9048 4 роки тому

    Anna oka 25 kva transformer nundi anni houses ki supply tisukovachhu

  • @ramakrishnapaaka1230
    @ramakrishnapaaka1230 3 роки тому

    Anna video Bhavana

  • @Know.unknown.things
    @Know.unknown.things 4 роки тому +1

    Please explain significance of vector group

  • @varalakshmi5517
    @varalakshmi5517 3 роки тому

    సార్ నాకు 100 kva trasnforrm 72 hp కనెక్షన్ ఉంది. Ctpt 11 kv mettering. No load టైం లో కూడా 15 యూనిట్స్ daily మీటర్ తిరుగుతది. ఇది ఇంకా ఇంతేనా లేక ప్రాబ్లెమ్ ఎక్కడ.

    • @venkateswaraajaad6543
      @venkateswaraajaad6543 3 роки тому

      నా పేరు వెంకటేశ్వర ఆచారి మీరు పవర్ ఫ్యాక్టర్ కెపాసిటర్ ఎప్పుడూ ఆన్లైన్ లో ఉండి ఉండవచ్చు వాటిని

    • @venkateswaraajaad6543
      @venkateswaraajaad6543 3 роки тому

      కెపాసిటర్ మోటార్స్ ఆన్లో ఉన్నప్పుడు మాత్రమే పవర్ ఫ్యాక్టర్ కె పాస్టర్స్ ఆన్ లో ఉండాలి లేదా ఏ పీ ఎఫ్ సి panel use చేయాలి

  • @rajujesus9961
    @rajujesus9961 3 роки тому

    Me number