People don’t realize how technical working on these things can be, there are so many factors within the unit and the surrounding environment that can contribute to why the unit isn’t working.
Hey refrigeration tech, i have a question iam struggling with, it will be great if you answer me, How do you decide if this unit has a 15 degrees or 30 degrees above ambient? Thank you !!
Hey sir , I tried to braze cap tube with nitrogen purging on regulator braze setting , but it was too hard to braze it because nitrogen coming through. Any suggestions?
I normally find leak at submersible coil for the condensate water. You should set up donation page like another guy. I learn many stuff from you then apply it to my customers.
I've been a heating and air contractor for the last 5 years and just got my refrigeration license. Your videos have been so helpful in preparing me for the specifics of refrigeration that aren't necessarily the same in a/c. This is a great example of information that is critical that would likely have been a hard lesson to learn if I went out on a repair not knowing. Just want to say thank you for passing along your knowledge and setting a great example. Keep up the good work! @@REFRIGERATIONKITCHENEQTECH
Why do you do design box temperature instead of actual box temperature? So say that the box was 50° now that you did your repair. Would you not do 50° - your TD to give you what your suction pressure / saturation temperature should be?
@@REFRIGERATIONKITCHENEQTECH okay now I understand that makes sense, thank you. Keep up the great work I really enjoy your videos being straight to the point and very technical 🤙
Man you make this so easy to understand. Your troubleshooting skills are too notch. Well done
People don’t realize how technical working on these things can be, there are so many factors within the unit and the surrounding environment that can contribute to why the unit isn’t working.
⬆️ 👍
Best hvac video in UA-cam ❤
l learns so much from the channel Please keep up with it. Thank you.
This channel is superb on its clear and concise delivery and is one of my go to channels thank you Anthony your valuable time and advice 😎💯👍👍👍
I appreciate that!
One of the best HVAC/R channel out there !
Great work on your videos. Definitely one if not the best channel to learn from. Thanks
Appreciate that
Yo man thank you. I understand so much more just from watching 3 of your videos
Hey Anthony, I'm glad you're back with more videos you really teaching a lot, thanks man blessings 🙏
Thanks!
Another great video Anthony! Was missing my Sunday morning coffee REF content. 👌
Lololol
I alwyas enjoy your videos. Good job as always. Thanks
Great video thank you
For a TXV system what should my evap td be and also what's the best way to find my condenser split ? Thanks for the great videos
Hey refrigeration tech, i have a question iam struggling with, it will be great if you answer me,
How do you decide if this unit has a 15 degrees or 30 degrees above ambient?
Thank you !!
Good tech work
Did you just patch over the leak with brazing alloy?
Great video
Awesome 👍👍👍
👍🙏
Excellent 👌👌👌
👍
I love your chart. Is that something you would like to share?
At some point I might package everything together in a course of some sort.
Hi I just got a question? I have under table freezer, but the start capacitor is bad can I use hard start kit for replace?
Hi Anthony is it the norm to use Imperial measurements in Canada or a combination of Metric and Imperial ? I have usually used both but I prefer Imp.
🇺🇸❄️👍💪 great troubleshooting information
👍👍
Hey sir , I tried to braze cap tube with nitrogen purging on regulator braze setting , but it was too hard to braze it because nitrogen coming through. Any suggestions?
I normally find leak at submersible coil for the condensate water. You should set up donation page like another guy. I learn many stuff from you then apply it to my customers.
In this case there was no coil like that, but that’s a great place where they leak.
How do you know the desired box temp and its TD?
Big picture diagnosis master
🤓👍
Hey Anthony, I'm glad you're back with more videos you really teaching a lot, thanks man blessings 🙏
How do you know how much evap td is?
Greeting
Generally reach ins are 20F, walk ins are 10F
Thank you@@REFRIGERATIONKITCHENEQTECH
I've been a heating and air contractor for the last 5 years and just got my refrigeration license. Your videos have been so helpful in preparing me for the specifics of refrigeration that aren't necessarily the same in a/c. This is a great example of information that is critical that would likely have been a hard lesson to learn if I went out on a repair not knowing. Just want to say thank you for passing along your knowledge and setting a great example. Keep up the good work! @@REFRIGERATIONKITCHENEQTECH
Why do you do design box temperature instead of actual box temperature? So say that the box was 50° now that you did your repair. Would you not do 50° - your TD to give you what your suction pressure / saturation temperature should be?
Cap tube is fixed, so desired temp is what is used. A TXV changes as pressure drops, so for that we use current temp.
@@REFRIGERATIONKITCHENEQTECH okay now I understand that makes sense, thank you. Keep up the great work I really enjoy your videos being straight to the point and very technical 🤙
lol you can see the rub on loop. will be a leaker. If no gas it needed welded build up.
Tech tip: Do not leak search r290 with a lighter 😂😂😂
😬
My leak detector was made by Bic and it’s disposable
So you put in r404a to check for leaks then let it go
Can't do that in the UK
F gas regulations
You use ofn or tracer gas