12-01 - Design of a Square RC Column using Design Aid

Поділитися
Вставка
  • Опубліковано 3 лис 2024

КОМЕНТАРІ • 18

  • @p.3914
    @p.3914 4 роки тому

    Wow! Great explanation. Easy to follow. Thank you.

  • @maryams3002
    @maryams3002 4 роки тому

    thank you .....so good video

  • @khaliltarabein8928
    @khaliltarabein8928 3 роки тому

    Thanks sir,one question :normally we calculate axial load manually so major moment multipied by eccentricity value=L/500+D/30 or min 20 mm,right?

  • @ibrahimriyadh7590
    @ibrahimriyadh7590 6 років тому

    Great job! you saved me

  • @Goodminton001
    @Goodminton001 6 років тому

    this helped me alot . thank you

  • @patrickabiang1915
    @patrickabiang1915 3 роки тому

    Hi! I hope this gets a reply. What's the reference for this video? I'd appreciate the response. Thank you.

    • @davidgarber1664
      @davidgarber1664  3 роки тому

      Hi Patrick, The diagrams that I show in this video are from Wight's textbook "Reinforced Concrete: Mechanics and Design" Appendix A.

  • @64Talon
    @64Talon 5 років тому

    Can you use this for rectangular columns as well or are there equations unique to square column behavior?

    • @davidgarber1664
      @davidgarber1664  5 років тому

      You can use the same procedure for rectangular columns. Make sure you have the column orientation correct for your direction of bending.

  • @wadrian9826
    @wadrian9826 5 років тому

    Hello, I want to ask that what if fy is not equal to 60 ksi (e.g 40, 50ksi), it seems that ACI has not provided these design charts

    • @davidgarber1664
      @davidgarber1664  4 роки тому

      You could use these design aids as a starting point and modify the required steel by a ratio of actual yield to yield for the design aid. You need to go back at the end and analyze your actual section with actual steel yield at the end.

  • @Himanshu.Barvaliya
    @Himanshu.Barvaliya 4 роки тому

    spacing between all of the bars : ( 22" - 2(1.5") - 2(0.5") - * 4(0.5") * ) / 4 = 4" - - - Where did you get the 4(0.5)? Video time : 11:42 / 16.09

    • @nazirghnim9340
      @nazirghnim9340 3 роки тому

      b bent = 4 d stirrups

    • @Himanshu.Barvaliya
      @Himanshu.Barvaliya 3 роки тому

      @@nazirghnim9340 In the picture, I only see : 22" overall length ( MINUS ) 2 x 1.5” - which is concrete cover that is encountered twice as you work towards the center of the column vertically ( MINUS ) 2 x 0.5” - which is the singular #4 stirrups that is encountered twice as you work towards the center of the column vertically ( MINUS ) ** 5 x 1.27” - 5 actual #10 rebars with 1.27" diameter in the column **
      So, above description should add up to : 11.65”.
      Dividing the left over space by equal 4 spaces : 11.65” / 4 spaces = 2.91”
      So, again, in the original calculation, where did the : 4 x 0.5” come from?
      So, I am not getting the 4" like What (Dr. David Garber) @David Garber got.

  • @jorgealbertobelmontguadarr3563
    @jorgealbertobelmontguadarr3563 6 років тому

    Where can I download this graphs?

  • @hugovalle1111
    @hugovalle1111 4 роки тому

    Dude, its a cool video but, the phi factor is 0.65 or 0.75 depending of transversal reinforcement. The 1.2 wd + 1.6 wl is to get the Pn and Mn.

    • @davidgarber1664
      @davidgarber1664  4 роки тому

      This example uses design aids with the varying phi factor built in. You should go back and analyze your actual design at the end. You can develop an interaction diagram (similar to what you would find in the videos in this playlist ua-cam.com/play/PLLhnAwUfiIPvGb4tM69GD-ammbq0BPS7R.html). The 1.2D + 1.6L is the load combination that will typical control when finding the required strength U (Mu and Pu in this example). You can look to ACI 318-19 section 5.3 for more information.

  • @abebetadie4529
    @abebetadie4529 4 роки тому

    thank u m.r