WATER PERMEABILITY TEST OF CONCRETE AS PER IS 516 (Part 2/Sec 1) : 2018 & DIN 1048 Part 5
Вставка
- Опубліковано 14 січ 2020
- Water permeability test determines the resistance of concrete against water under hydrostatic pressure. This permeability test should be considered the dominant test to evaluate the case whereby concrete is subjected to hydrostatic pressure.
- Наука та технологія
💯% helpful video for Concrete permeability test. Thanku Sir.
This type of content in the laboratory concrete is important to see because of several water to cement (w/c) ratios were we can made and then, physical and mechanical properties of hardened concrete including porosity, permeability, compressive strenght, tensile strenght and flexural strenght BUT in all w/c ratio, a similar trend was observed in the compressive, tensile and flexural strenghts of concrete containing RHA AND FIBERS FOR GREEN BULIDING. The use of various FIBERS IN CONCRETE AND MAKING FIBROUS CONCRETE called FRC is an ~ EFFECTIVE STEP IN PREVENTING THE EXPANSION OF MICRO-CRAKS AND COMPENSATING TENSILE STRENGHT WEAKNES OF CONCRETE~. It is good to see laboratory work as well as in important characteristics of FIBROUS CONCRETE to reduces many characteristics but in general, THE FIBERS IN THE PERVIOUS CONCRETE SIGNIFICANTLY INCREASE PERMEABILITY WHAT WE CAN IMAGINE IN YOURS VIDEO PRESENTATION.
Excellent explanation Sir... Thank you.
Superb video you have been super liked by civil engineering testing walk
Thanks for appreciation.
Thanks highway team, first time watching this test
Thanks for appreciation.
Thanks highway team, first time watching this tes
Our pleasure!
Very good excellent video sir , i got the practical visula experience
All the best
Dear sir,
At which level we fill water into a water tube either full or some portions empty
Awesome explanation step by step sir..thank u so much🙏🙏
Keep watching
Sir which of Concrete permeability apparatus used in this video
Really very helpful video.....👍
Thanks a lot
Sir cube ko dry kaise karna hai???..... Oven dry after 28 days of curing
Thanks
Well done sir
Thank you so much sir 🙏
Hi. Thanks for the videos, btw could you share the code that requires maximum water penetration max 25 mm? I have downloaded the Din 1048 but can't find the limitation for water penetration. thank you.
As per MORT&H 5th Revision
Please provide link to download this code
Classic sir..
Thanks for appreciation.
thanks for the video
You're welcome
Sir please explain how to all calculation in this test according to DIN 1048 part5
Actually , you are not seeing the whole video with interest , in this test there is no calculation . Only we had to measure the depth of pentration after splitting the cube .
Sir, how much time we have to give for wait after splitting of cube? While DIN 1048 part-5 is saying "When the split faces show signs of drying (after about 5 to 10 minutes).............established". Please suggest sir it's very confusion.
After few minutes may be 2 minutes
@@HIGHWAYGUIDE thank you sir
Sir iska test report format chahiye
why the rod is kept during ctm test
To split the cube in two parts.
Thank you sir
So nice of you
can we do this test in mortar specimen of 7×7×7 in the same apparatus
Not allowed for mortar specimen , this test is meant for hardened concrete.
There is no specification for mortar cube , but we check the seepage for mortar plaster , when cement plaster is mixed with water proofing material
एक बार मे 3 cube का सेट Test करना है या set के no. को भी बढ़ा सकते हैं
@@QualityMust Test for 3 or can increase
Sir Water Permeability Test of Limit (IS 516 Part-2/Sec-1):2018 or DIN 1048 Part-5 Both these codes may not be the limit. where is 25mm limit please provide code clause no.
Please see section 1700 of MORT&H 5th Revision clause 1717.75 point number 6 Page number 562
Kithna pani dalna padta hay
Please see full video with interest
Good
How can connection with u sir??
rajesh@highwayguide.co.in
Hello sir Iam working on porous concrete and how can I do permeability test we dont have this apparatus any other solution for this?
No
@@HIGHWAYGUIDE sir is it ok, if your location is near by can we come to your lab and perform the permeability tests on our samples.
There are so many laboratories doing this test. You can contact nearby.
Specified limit kya hai sir iski ?
Please see full video
Sir make a channel on telegram on what's app for discussion , this is simply request
OK will think.
Excellent explanation Sir... Thank you.
Thanks and welcome