Building a Linear Power Supply, Part 1 The Transformer

Поділитися
Вставка
  • Опубліковано 25 тра 2023
  • The first stage of a linear power supply is a transformer to step the mains/grid voltage down to a reasonable level.

КОМЕНТАРІ • 17

  • @TonTonTon140
    @TonTonTon140 Місяць тому

    Thank you for the video. Very helpful. I am new to ham and am looking to build a power supply as my first project

  • @neilphilip2320
    @neilphilip2320 4 місяці тому +3

    These videos are fantastic! Wish I'd found them earlier.

  • @mukhtaralkhatib7740
    @mukhtaralkhatib7740 3 місяці тому

    I always find it useful and informative ❤

  • @zalves2000
    @zalves2000 9 місяців тому

    Thank you for the lessons!

  • @peterlethbridge7859
    @peterlethbridge7859 7 місяців тому

    Great video, thank you.

  • @mikemike7001
    @mikemike7001 Рік тому +1

    I'm sure there are official standards, but line voltage in the U.S. is generally 110-120V ±5-6%. Edison's first power plants produced 110V DC, and this voltage more or less stuck. After WWII, 117V was adopted as the standard. Today, 120V is the target voltage for most power companies. Power companies regulate the voltage based on load, and adjustments can take a few minutes. Minor variations in line voltage usually don't cause problems. Equipment that requires precise voltages uses regulated power supplies. Frequency is more tightly controlled, originally so that clocks with synchronous motors stayed within a few seconds of the correct time.

    • @BoxingDayAC
      @BoxingDayAC 5 місяців тому

      I'm surprised people say it's 110V-120V. I worked for a utility in the U.S. and we were limited to 120V ±5%. My own outlets read 120-123V. Maybe there's some WWII construction that's still 110V but I haven't seen for myself. On all other points this is 100% correct. Frequency is very close to 60.0 Hz, much tighter than 5%. Old computers and clocks also used it for time.

  • @djjackson2200
    @djjackson2200 Рік тому +1

    LOL, wish i had your power company. Closely regulate 60HZ and exactly 117 volts? Not even on Sundays if you lived here.

  • @bnorton916
    @bnorton916 Рік тому +1

    Dumb question: why is the output a sine wave if it has been converted to DC?

    • @bnorton916
      @bnorton916 Рік тому

      I just watched the last 10 secs where he talked about a rectifier that changes AC to DC. So a wall wort is a transformer and a rectifier?

    • @justin.campbell
      @justin.campbell Рік тому

      @@bnorton916 Yep! They have a transformer, rectifier and filtering capacitor to smoothen out the voltage. Newer ones use a switching converter which can be much smaller and more efficient, but it is much more complicated.

    • @BoxingDayAC
      @BoxingDayAC 5 місяців тому

      The AC hasn't passed through the diodes to rectify the AC to DC yet. What you see is the AC voltage after being reduced from the power outlet ~120V to ~10V from the transformer. Yes, most wall worts are but you can buy ones with just a transformer like what you see done here.

  • @petterpfalzer9007
    @petterpfalzer9007 Рік тому +6

    You should not leave live wires just sitting on the table, this is seriously dangerous. Isolate them with WAGO clips for example

    • @BoxingDayAC
      @BoxingDayAC 5 місяців тому

      I'm in awe of the extreme danger on display while using cheap as possible equipment and buying a transformer on Amazon versus an official distributor. Jameco is fine, if it's real.

  • @caleb7799
    @caleb7799 5 місяців тому

    clear your throat.