Thank you very much sir...ap ka har video mai dekhta hu...ap ka explain karne ka tarika bahut acha hai. aap aur bhi video dalye power plant ko lekar....aur interview basis question ko lekar bhi dalte rehye...
@@instrumentexpert7780 sir, commenly use same probes and proximity sensor for Axial, radial and keyphasor measurements but how we can understand that is used which vibration??
As process can change tag of Transmitter, control valve and other instrument when process is different, Tag changed , For example one control valve , On pressure control tag is PCV On temperature control tag TCV On flow control FCV It means same control valve same function but tag( name ) changed due to process ( function) Just like same probs (some difference on specifications, tips ,length, proximitor) but when install displacement tag ( radial) When thrust movement (axial) but prob is same
MashaAllah bauhat zabardut great faisal sb, thanks
Thanks for response
SIMPLIFIED, BEST EXPLANATION
V nice post
Thanks for response
Thank you very much sir...ap ka har video mai dekhta hu...ap ka explain karne ka tarika bahut acha hai. aap aur bhi video dalye power plant ko lekar....aur interview basis question ko lekar bhi dalte rehye...
Thanks for response ,
Thanks for new ideas like that
Iam trying to my best,
Thanks again dear sir
Yes dear Brother inshaAllah
Jobs related bhi video upload kijye sir aur ye bhi bataye ki client company me kaise apply karu direct online...jisse mujhe kuch maloom ho sake.
Beamex mc6 abhi advantage me ye instrument calibrator hai...iske bare bhi ek video bnayega sir...latest
Thank you so much for giving you this video there is a lot to learn against you and these videos are very useful
Thanks dear , iam trying to explain with practically videos
Sir agar 8mm ka tip hi to kitna mm tak sens kar sakta hi
Good chachu
Good work 👍😀👍
If distance between prove and shaft is zero what voltage value we will get ?
Analyser k bare bhi explain kijye. analyser technician...aur offshore aur onshore me kya advantage hai disadvantage hai wo bhi bataye...
Yes dear Adil Raza , it's depend on time so video need time editing and composition that's why plz,
Excellent sir I am impressed , well explained sir
Thanks dear
Thank you Bayya. Clear information, bakwas ne hai abi subscribe kar diya
Thanks allot
Sir mujhe axial radial or key phesor ka unit mane bataye
Why is supply negative ????
Gd work
Thanks dear
Thanks so much for your explanation
Thanks for response
Well explained. Sir
How can we identify types of vibration probes!??
Identify due to its installed position, which angle we want to measure, thrust or displacement Etc
@@instrumentexpert7780 sir, commenly use same probes and proximity sensor for Axial, radial and keyphasor measurements but how we can understand that is used which vibration??
As process can change tag of Transmitter, control valve and other instrument when process is different, Tag changed ,
For example one control valve ,
On pressure control tag is PCV
On temperature control tag TCV
On flow control FCV
It means same control valve same function but tag( name ) changed due to process ( function)
Just like same probs (some difference on specifications, tips ,length, proximitor) but when install displacement tag ( radial)
When thrust movement (axial) but prob is same
Sir, it would be great if you could make a video about HatCommentator
Please tell mi what you want ?
Only HART or Calibration with Hart
Why it's say 5 meter or 8 meter system? Is it wire length or electrically some measurements?
Electrically length, and it's 5 and 9 mtrs
Good job sir like your video
Thanks for response
Vibration probe ko field main kiya check kareyenge sahi hai ya galat sensor
Connect hy loop ki sath to proximeter se output check krengy, common and output terminal pi
Redial he ki Axel kese pata kare
Equipment discretion se sir
As well explain why -10 vdc like it's mills measurement and why it's 50 mills?
-10 vdc, acording to a sensitivity 200 mv/mils, it's almost 50 mils
need TK3 to check gap voltage liniearity
Bhai vibration probe ka input Dc volt -24 ya 24vdc hota pls tell me
-24 vdc bhai
Sit negative voltage kyon dete hain vibration transmitter ko
Excellent sir thank you
Thanks for response sir
Very very thanks sir
Thanks allot Dear
Wow
Thanku so much
Thanks MD Akbar Bhai
Can you make English subtitles for your videos better understand
Yes dear will try
Why -24 volt supply?? Why cant use +24v
Cause is the original desing, and work better like others manufacturers
As salam alaikum
Sound not clear
Yes
Your what's up no
PREDICTECH TO PROVIBTECH TTHEN PVTVM!