Victron Cerbo GX & EG4 Battery Compatibility & Communications. Victron Quattro 15kW & EG4 Load Test

Поділитися
Вставка

КОМЕНТАРІ • 59

  • @mudslinger995
    @mudslinger995 Рік тому +17

    What is the "modified" cable were do we find a design or a complete cable?

  • @grumpyshorts1056
    @grumpyshorts1056 Рік тому +4

    Looking to connect my EG4 LL's to my Victron Cerbo... you said modified cable! Is that cable for sale on your website???

  • @keep-lookingup
    @keep-lookingup Рік тому +4

    it would be nice if there was a drawing and a video for the Lifepower instead of the LL model of batteries....

  • @grumpyshorts1056
    @grumpyshorts1056 Рік тому +3

    I just bought the newest EG4 12v... Is there a manual to connect to the Victron Multiplus II 2-120 with a Cerbo gx with the 50 monitor screen?

  • @kurtmcclelland1086
    @kurtmcclelland1086 10 місяців тому +1

    Adam, thanks for the video. Is there any way the multi plus 2 can be bypassed in the event of a failure? it’s a pass though inverter so if you have battery issues or MP 2 issues your dead in the water. I was thinking maybe a physical switch before and after the inverter, what do you think?

    • @SignatureSolar
      @SignatureSolar  10 місяців тому

      Yes by using a manual, or automatic transfer switch.

  • @simeonnandalall3969
    @simeonnandalall3969 Місяць тому

    I have a 10k 120v victron inverter i would like to use the split phase option that the autotransformer provides when paired. Whats the max wattage of each leg of the output?

  • @Scat.original
    @Scat.original Рік тому +1

    Why 2 positive wires from EG4 racked batteries to 2 bus bars then to 2 200Amp breakes then two wires to the 2 DC input on the Inverter Charger?

  • @MattSmith-py6ul
    @MattSmith-py6ul 2 роки тому +6

    Can the EG4 LifePower4 also communicate through the Cerbo GX? If so how?

    • @George_us
      @George_us Рік тому +1

      I just upgraded my EG4-LL V1 firmware with Victron, and it is talking to cerbo gx. I believe there is also an update for lifepower.

    • @jeffsyslo8519
      @jeffsyslo8519 Рік тому

      Was this ever figured out? I'd like to get rid of the smartshunt to monitor my lifepower with the Cerbo

    • @George_us
      @George_us Рік тому

      @jeffsyslo8519 Look for a UA-cam video from EG4 Electronics that shows how to update different versions. My EG4-LL (version one) is showing as a Battery Monitor under Cerbo gx, which means I could use it in place of the Victron Smartshunt. However, I am getting over voltage warnings when SOC gets close to 100% and they get cleared by themselves. I am trying to figure out what is going on. Therefore, I don't recommend updating the firmware. You also need a cable between the master battery and cerbo gx.

  • @arleneallen8809
    @arleneallen8809 2 роки тому +2

    Will this work with the updated batteries and a Sol-Ark 15k for the inverter? I've been using a Cerbo GX with Victron Smartshunts to monitor the EG4 batteries.

  • @fawkmee
    @fawkmee 2 роки тому +5

    Wait.. are you guys going to start selling Victron equipment??

  • @Jhovan33
    @Jhovan33 Рік тому +1

    Can you get a cable to connect the cerbo gx to the basic lifepower 4 original battery to work with a multiplus II? Right now I'm using a victron smart shunt.

  • @loucinci3922
    @loucinci3922 Рік тому

    I noticed another YT'er had this rack but it did not have the cable management "fingers" around the bus -bars. He had to remove the chrome handles off the batteries to make installation safe. Does SigSol offer a re-call type fix to provide cable management to prevent bus-bar issues?

  • @SouthFloridaFishingClub
    @SouthFloridaFishingClub 6 місяців тому

    How are you connecting battery to Cerbo? I have the special cable but since I have other things and the last units need to be terminated I’m not able to hook up the battery and for it to show

    • @SignatureSolar
      @SignatureSolar  5 місяців тому

      It’s just a communication cable and it’ll be Cat 5/6 from the batteries to the VE CAN and you should have received terminators to put in the other VE port

  • @SteveSmithIII
    @SteveSmithIII 2 місяці тому +1

    Never could get ahold of anyone there. Finally just did a chargeback on the visa and let them deal with SS.

    • @SignatureSolar
      @SignatureSolar  2 місяці тому

      Hi! We're so sorry you had trouble! Which company was it that you couldn't reach? If you need any assistance, you're welcome to reach out to us directly at engagement@signaturesolar.com!

  • @bikerkiter
    @bikerkiter 2 роки тому +2

    Noticed the Victron showed at large DC load (~700 watts). What is that from?

    • @pifle9471
      @pifle9471 Рік тому

      lighting for the video (?)

  • @CampPrevost
    @CampPrevost 2 роки тому +2

    Will this work with the previous EG4-LL or just the new version? Does the new version’s pre start resister work with the inverter or did you have to charge it first?

    • @George_us
      @George_us Рік тому

      It appears to be working with EG4-LL V1 after victron firmware update. EG4-LL v1 has built-in current limiting resistor, 1st close circuit breaker, then turn on BMS.

  • @pewpewpew8390
    @pewpewpew8390 2 роки тому +2

    was the test done using a single of the 6 batteries? I'm planning to use either quattro or multiplus, so thanks for video, but would be great to show the linking of the remaining bats and such :) allready got 4 of the new v2 bats!

    • @SignatureSolar
      @SignatureSolar  2 роки тому +6

      All 6 were in use communicating. You only need to link the master battery to the Victron system. The master battery will then communicate downstream to the remaining batteries

  • @BillFye
    @BillFye 10 місяців тому +1

    The Quattro is a beast!

  • @loucinci3922
    @loucinci3922 Рік тому

    Is the top battery in the rack the #1 battery (1/6)?

  • @maddeusdoggeus1
    @maddeusdoggeus1 3 місяці тому

    Thanks Adam👍

  • @SamSung-jn5fi
    @SamSung-jn5fi 7 місяців тому +1

    Compatibility with PowerPro batteries?

    • @SignatureSolar
      @SignatureSolar  6 місяців тому +2

      Yes!

    • @SamSung-jn5fi
      @SamSung-jn5fi 6 місяців тому

      @@SignatureSolar we need a quattro 10kva x2 solar kit/bundle

  • @George_us
    @George_us Рік тому

    Does this video also apply to EG4-LL (version 1 with display)?

  • @Scat.original
    @Scat.original Рік тому +1

    It would be great if when describing the changing of the menus that the camera would show the screen of the battery so we could see and read the screen of the battery, also is this documented with screen shots some where on your server?, like under addtional area in the EG4 battery specs, Thanks

  • @pifle9471
    @pifle9471 Рік тому

    So, that means if I simply use a Victron smaller system for an RV (battery charger from AC and 1200 Inverter, separated units) with the Cerbo GX, I could use an EG4 rack battery without problem ? Nice

  • @carlossantini
    @carlossantini Рік тому

    why no SOC indication?

  • @earlzeis35
    @earlzeis35 Рік тому

    Will this communications with Victron work on the 12v 400ah packs as well?

  • @9-5Adventures
    @9-5Adventures Рік тому

    do you need the smart shunt with this?? does the cerbo GX show the batteries charging or do you need the smart shunt for that?

    • @George_us
      @George_us Рік тому +2

      I am learning myself, but it appears that the smart shunt is no longer required since cerbo gx is now talking to the batteries.

  • @daviddennis8642
    @daviddennis8642 2 роки тому

    Can the Cerbo GX also communicate with the Growatt inverters?

    • @SkyNoris
      @SkyNoris 2 роки тому

      Currently Growatt inverters and Cerbo GX are incompatible as far as comunication goes.

  • @dennisbradystudios
    @dennisbradystudios 2 роки тому

    Hi Adam, thanks for the compatibility test using the Victron and your EG 4 LL batteries. I'm using a Magnum 4024 inverter and Midnite solar's Classic charge controllers. I want to upgrade my flooded lead acid L 16 batteries to yours and even got a quote from your sales department a few months back indicating that they would work with my system. Last week I went to place my order and I was told that EG 4's will in fact NOT work with my Magnum inverter. 7 years ago when I installed it, Magnum was a leader in the off grid world with tens of thousands sold. I'm really confused and ready to buy but I'm getting mixed answers from your tech staff. Any chance of testing the compatibility of Magnum inverters with your batteries?

    • @SignatureSolar
      @SignatureSolar  2 роки тому

      Magnum Inverters should work fine without communication. Just set the charge settings on your inverter correctly. You can find this information on the EG4 Specification sheets and manual

  • @patriciamariemitchel
    @patriciamariemitchel 2 роки тому

    I like it.

  • @sbramel93
    @sbramel93 5 місяців тому

    Nothing happens when I hold the back button for 5 seconds

    • @SignatureSolar
      @SignatureSolar  5 місяців тому

      If you'd like to reach out to our tech support department at 903-441-2090, we can get you taken care of!

    • @travislangley880
      @travislangley880 2 місяці тому +1

      You have to have the dip switches on the master battery set to all zero's or that function wont work. Then after you make the changes you can put the dip switches back.

  • @t.d.harris1311
    @t.d.harris1311 2 роки тому +5

    15000 dollars to run a cloths dryer and fan. I put my wife up a 50 ft. cloths line for 100 dollars. Love the solar concept, you guys seem to be the best. But for the average family living in rural America, this is way out of our reach.

    • @SignatureSolar
      @SignatureSolar  2 роки тому +4

      This system could easily power an off-grid homestead on its own with adequate solar generation. With 15000w with either a victron or 2x EG4 6500s, you can run a well pump, 3+ mini splits, water heater, kitchen and laundry appliances, lighting, and entertainment centers + more. In a lot of situations, it would cost you more than 15000 dollars to get an electricity line ran to your property. Going off-grid with solar makes a ton of sense for many people. If you are interested in learning more feel free to contact our design or sales department if you would like to see how one of our systems could work for you. Even if you don't decide to purchase, it's our responsibility to make solar simple for everybody.

    • @kobusswart
      @kobusswart 2 роки тому +9

      Compared to running utilities for a mile to a rural property, this is small change...

    • @VarkaTheDragon
      @VarkaTheDragon Рік тому +1

      The main thing that a system like this provides, is everything *else* other than powering a drier. Like heat (mini splits), water well pump, internet and so on.

  • @TheKallipugos
    @TheKallipugos 2 роки тому +2

    Has anyone ever been successful getting someone at Signature Solar on the phone? I have literally spent hours upon hours on hold on their phone system. Just when you think they are getting close to answering, they dump the calls.
    Today alone, I’ve wasted over 2 hours trying to call them.
    They don’t call back when you leave your number either for a scheduled callback.
    I’ve even reached out via email with no response.
    Hopefully, this will get some attention.

    • @kobusswart
      @kobusswart 2 роки тому +1

      No issues for me. The wait time varies depending on when you call. Longest I ever had to wait was 30 mins and the phone system tells me where I am in the queue. Been able to talk to tech support, sales and shipping a number of times. They even called me back on one occasion when I hung up after I managed to answer my own question.

    • @jungleking7197
      @jungleking7197 Рік тому

      I didn’t have any issues I called and got connected in about a minute