That was excellent. I did understood the solenoid valves. They have a lot of applications in mechanical ventilators in intensive care . Thank you so much.
Very well explained the basic principals of Proportional Valves with quite a simple example. Thank you very much for the lovely video and wishing you all the best and have a great future. Kind Regards . . .
where can I buy the solenoid valve you used in the video and roughly how much would it cost me? Also, how much of the equipment you used is necessary for the valve to work and could I control it with an arduino uno board?
kcc2018.cafe24.com/en/bbs/search.php?url=http%3A%2F%2Fkcc2018.cafe24.com%2Fen%2Fbbs%2Fsearch.php&stx=kpcs Above link is to KCC Precision's KPCS series. :)
Can it be used to control LPG (gas) flow... particularly the model u have displayed...is it an open type or close type... i need an open type proportional valve..would be thankful if u please provide link for purchase of it...thanks
Hi. Can i ask, does the valve restricts air flow when the solenoid suddenly stop. I have this problem on my machine that when the machine trip off the cylinders inside in suddenly falls down.
The pilot and diaphragm both have one thing in common: the way they operate to control large flow rates with low power consumption. The difference is that the pilot type controls the flow path through the 'pilot hole', and the diaphragm controls the flow path through the 'diaphragm'. There is a video made for the pilot type, so please refer to it. ua-cam.com/video/oCPR6fzgm_g/v-deo.html
Thanks for the video.We have a problem w/ the speed of hyd cyl using proportional valve.The cyl does not not move smoothly during slow speed,theres jerking movement.We already replaced the proportional valve but the problem still exist.Is the controller has problem?Hope to hear from you.Thanks
Thanks for watching. It is difficult to determine exactly what kind of problem there is because I do not know the exact environment. However, if the controller is a problem, jerking movement is unlikely. When air is filled inside the cylinder, it often happens. So try to bleed the air inside the cylinder.
@@MsPneumatic Thanks for your reply,the jerking movement only happens during the very very slow speed of cyl.if we put the speed of cyl from 0 to 10, the problem occurs during the no.2 speed.but at other speed value it does not happen or maybe its not noticeable.Again thanks for your videos.Very informative.
Hello. Thank you for the video Ms Pneumatic. So if I want to control the acceleration/desacceleration speed ramp of a double acting cylinder, I suppose need two proportional 2/2 valves connected as close as possible to the cylinder and a 5/2 pneumatic valve...is that correct?
I have a question, can the microcontroller adjust the plunger ? What I mean not just to open or close it , also control it by setting it for example half opened ?
Ideas where I can find a micro proportional solenoid valve? I'm trying to find one very small and lightweight with max voltage 6V, better if 3V. I'd like to find one "in-line", like a check valve, but which can control the flow in the garanted direction!
kcc2018.cafe24.com/en/bbs/search.php?url=http%3A%2F%2Fkcc2018.cafe24.com%2Fen%2Fbbs%2Fsearch.php&stx=kpcs I'll attach a link to the product in the video(KPCS series). Please check if it is the product you want.
와.. 한국채널인지 모르고 들어왔네요. 도움 많이 되었어요!
Thank you again!!!
Keep up your hard work, with time your channel will get proper recognition.
That was excellent. I did understood the solenoid valves. They have a lot of applications in mechanical ventilators in intensive care . Thank you so much.
Keep it up Ms. Pneumatic... Love from Bangladesh 🇧🇩
Thank you 🙂
great Ms. PNEUMATIC..
Very well explained the basic principals of Proportional Valves with quite a simple example. Thank you very much for the lovely video and wishing you all the best and have a great future. Kind Regards . . .
Thanks for the great explanation
Thank you!
where can I buy the solenoid valve you used in the video and roughly how much would it cost me? Also, how much of the equipment you used is necessary for the valve to work and could I control it with an arduino uno board?
Very nice. The informations was importante for my design.
very very good explanation madam, thank you very much for sharing your valuable knowledge with us🙂🙂
Pls can u share the connection diagram for the pinwheel example that u explained/showed in the video
Thanks for the very helpful video! Do you have a link to the brand of proportional solenoid you used?
kcc2018.cafe24.com/en/bbs/search.php?url=http%3A%2F%2Fkcc2018.cafe24.com%2Fen%2Fbbs%2Fsearch.php&stx=kpcs
Above link is to KCC Precision's KPCS series. :)
can you please tell where can i find these products
These are KCC products.
You can check the KCC website through the link below.
KCC website: www.kccpr.com/en/
Thank you.
how can i order that kcc pv ? i have been in the website but there was no information about how to order it
Hello, you can send an inquiry to the email below.
- Email address: global@kccpr.com
Thank you.
Thanks
amazing....
Great video.
I m also work in a hydraulic field.
Where are you from?
Can it be used to control LPG (gas) flow... particularly the model u have displayed...is it an open type or close type... i need an open type proportional valve..would be thankful if u please provide link for purchase of it...thanks
Could you let me know the model or maker of PCV controller circuit please?
The product name of the controller in the video is KPCC-1.
For more information, please contact sohyun7958@kccpr.com.
Hi. Can i ask, does the valve restricts air flow when the solenoid suddenly stop. I have this problem on my machine that when the machine trip off the cylinders inside in suddenly falls down.
Where can I get or what's the model of the proportional eletrovalve featured in this video?
Can you please do a video of Pr 2224 proportional valve controlller
best
what's different about diapraghm and piston pilot valve?
The pilot and diaphragm both have one thing in common: the way they operate to control large flow rates with low power consumption.
The difference is that the pilot type controls the flow path through the 'pilot hole', and the diaphragm controls the flow path through the 'diaphragm'.
There is a video made for the pilot type, so please refer to it.
ua-cam.com/video/oCPR6fzgm_g/v-deo.html
you use Proportional Control Solenoid Valve generation ?
What does 'generation' mean? I am not sure which machine you are referring to by 'Proportional Control Solenoid Valve generation'.
Thanks for the video.We have a problem w/ the speed of hyd cyl using proportional valve.The cyl does not not move smoothly during slow speed,theres jerking movement.We already replaced the proportional valve but the problem still exist.Is the controller has problem?Hope to hear from you.Thanks
Thanks for watching.
It is difficult to determine exactly what kind of problem there is because I do not know the exact environment. However, if the controller is a problem, jerking movement is unlikely. When air is filled inside the cylinder, it often happens. So try to bleed the air inside the cylinder.
@@MsPneumatic Thanks for your reply,the jerking movement only happens during the very very slow speed of cyl.if we put the speed of cyl from 0 to 10, the problem occurs during the no.2 speed.but at other speed value it does not happen or maybe its not noticeable.Again thanks for your videos.Very informative.
@@johnevan7737 are you restricting the air input to the cylinder or the air exhaust at the other side? restricting exhaust leads to smoother operation
Hello. Thank you for the video Ms Pneumatic. So if I want to control the acceleration/desacceleration speed ramp of a double acting cylinder, I suppose need two proportional 2/2 valves connected as close as possible to the cylinder and a 5/2 pneumatic valve...is that correct?
I have a question, can the microcontroller adjust the plunger ? What I mean not just to open or close it , also control it by setting it for example half opened ?
Yes. The 'proportional control valve controller' can control electricity to control the degree of closing of the plunger.
Ideas where I can find a micro proportional solenoid valve? I'm trying to find one very small and lightweight with max voltage 6V, better if 3V. I'd like to find one "in-line", like a check valve, but which can control the flow in the garanted direction!
kcc2018.cafe24.com/en/bbs/search.php?url=http%3A%2F%2Fkcc2018.cafe24.com%2Fen%2Fbbs%2Fsearch.php&stx=kpcs
I'll attach a link to the product in the video(KPCS series). Please check if it is the product you want.
Thanks and i want to see your face
14ma for 50% cause i'm that idiot.
math never my strong point.
Very informative..
#mechexpvivek