Siemens LOGO! 8 SF4_1 Analog AM2 AQ output card, wiring and setup using LogoSoft v8.2. English

Поділитися
Вставка
  • Опубліковано 19 жов 2024

КОМЕНТАРІ • 13

  • @RolandoSumikiab
    @RolandoSumikiab 3 місяці тому

    Thank you for your clear explanation...

  • @sabitferati1564
    @sabitferati1564 4 місяці тому

    Very good

  • @Patrick_Hornaua_Sj
    @Patrick_Hornaua_Sj Рік тому

    Can i use one TDE to control 3 Logo8 (without display) to input target temperature to my program? They are connected through LAN-Switch

  • @sathyaseelanperumal8896
    @sathyaseelanperumal8896 Рік тому

    Hi IGS,
    How much does AM2 AQ2 expansion card cost, I enquired the price of this, it is more costlier than LOGO 8! PLC.
    Does it cost's 97$? Please suggest me a website buy it in reasonable price.

  • @joeltshiela4605
    @joeltshiela4605 Рік тому

    hello, please, I would like to drive a lambda tdk power supply from the logo PLC but only programming the AM2 AQ output (I have nothing as an analog input). how to control the AM2 AQ output without an analog input?

  • @joeltshiela4605
    @joeltshiela4605 Рік тому

    Hello, please, I am new to siemens Logo. Can you help me make a program that automatically drives the AM2 AQ Analog Output (without using an analog input). THANKS

  • @gal766
    @gal766 2 роки тому +1

    Hi, Sorry for the stupid question, but wouldn't it be smarter to simply use two logos? instead of separate modules that just deliver two connections?

    • @IGSElectronics
      @IGSElectronics  2 роки тому +1

      My friend there is no such thing as stupid questions. What do you mean by using 2 logos? Can explain the process you are trying to achieve?

    • @gal766
      @gal766 2 роки тому

      @@IGSElectronics Thank you for your response, I see that each extension module has only so much connections, were the logo itself has more connection and is more powerful + cheap, so if I ran out of configurable pins I can simply buy another logo and connect them together correct? (I don't know the amount of legs I will need since I need to "play" with the system first to see how powerful it really is.. having a S7-1500 will be simpler, but the cost for a starter kit is just too high and after a year you don't have a software anymore..)

  • @krassebewegtbilder
    @krassebewegtbilder 2 роки тому

    Do I have to provide 24V from a power supply? Doesn't it get that via the pin connectors on the side?

    • @IGSElectronics
      @IGSElectronics  2 роки тому +1

      All add on units will require 24V dc supply.

    • @krassebewegtbilder
      @krassebewegtbilder 2 роки тому

      @@IGSElectronics Ok, thanks, is there an good alternative to the expensive siemens one?

    • @kb441ate
      @kb441ate 2 роки тому

      @@krassebewegtbilder PULS