Hi, your video was helpful. We have the same Bosch washing machine and we have got vguard 0.24 hp booster pump. However, the machine does not accept water when the booster pump is in automatic mode. And it accepts water only when in manual mode. I'm afraid that this will affect our electricity bill. We can't figure out how to get the machine to work when the booster pump is in automatic mode.
@@creatorsDesigns ok you can use NRV in suction line for pressurized and it will work in auto. Because auto will work only when delivery line is pressurized and it will off . Give me your email address I'll send you diagram of setup
You have v-guard pmp: www.amazon.in/VCB14-F030Automatic-Pressure-Suitable-Circulation-Washing/dp/B08QD2X657/ref=asc_df_B08QD2X657/?tag=googleshopdes-21&linkCode=df0&hvadid=396988570317&hvpos=&hvnetw=g&hvrand=8500245520655138535&hvpone=&hvptwo=&hvqmt=&hvdev=c&hvdvcmdl=&hvlocint=&hvlocphy=9062079&hvtargid=pla-1223069012326&psc=1&ext_vrnc=hi
Sir, Can I install this pump near by Washing machine? Because I want to use this machine for boosting water speed to Washing machine only. My water tank of 500 ltr only. Therefore I also need to ask one more question to you :- How much liter water it will be supply to Washing machine for 1wash (45 minutes wash)?
This is infact installed only for washing mashine. But since there is a wall you are not seeing that. This is just 0.1 hp and can be contacted to one instrument
Sir, bought Bosch washing machine series 6 1400 rpm. The person visited house for demo said it requires 1 hp pressure. In your video shown pressure booster pump works on said mentioned Bosch washing machine
I bought Crompton water booster for this Bosch washing machine it shows tap fault on auto mode works only on direct mode motor runs all the time you can't go anywhere while machine is on what to do with my new Bosch washing machine don't know😢
Hi Sir, thank you very much for making this video. Could you please let me know As of now are you facing any issue with Motor Or bosch machine?? Any maintenance is needed??
BOSCH mahine will not have any issue with this. I have running the pump in auto mode for 2 years I never had an issue to date. Both washing and pump running fine.
Standard angle cock fittings size 1/2"(13 mm). You will get two connectors for the pressure pump. After the connector, you will need one connector to connect your washing machine pipe which will be available in most of the hardware shops. See these details in the below section of the video. ua-cam.com/video/XamT1qeKt1A/v-deo.html
i had also bought it for bosch machine , it is working very well without connecting to machine, but when we connect it to machine it is not working , if u know about it pls tell us
I think you put that in manual mode. Please make sure it is in automatic mode. When the machine opens the water inlet solenoid it will automatically switch the pump.
Sir, we have our tank just inside out flat at a mere height of say 2 metres hardly. Water pressure is very very low. Please guide what can help increas the pressure.
Sir i've got a Bosch 8kg front load washing machine, connected with 0.24 hp vguard booster on automatic mode but it shows low pressure warning while running, what should i do now? Please help
@@Ava-pp8fn yes sir now its not there, it was due to the air in hose, 0.24 hp booster vguard pump is working fine ... Check the connection of pipes and redo them
@@Ava-pp8fn get a pump dear, Bosch is the best one out there but all front load machines need high pressure water which can be obtained by a booster pump... Its a small waterproof pump and doesn't make any sond at all
Is it working in auto mode? Can you please send the specifications of pump you purchased, I brought Bosch washing machine front load. And is the v guard pump working fine?
Hi, i just ordered the same from Amazon after watching your video for same use case. I just wanted to know whether it is delivering the mentioned water per min
There is a problem with this setup. The automatic pump will switch on only when water is flowing, but the machine will not let the water flow because it has low pressure. We need to keep the pump on manual mode as long as the machine is working. Not suitable.
@@gurucp2005 Thanks a lot for replying, I need help, this problem is giving me headache. How high is your water tank from the machine inlet? Mine is just 8-9 feet. I'm worried that automatic pump won't start because the washing machine won't let the water flow (I mean, the automatic pump starts only when water starts flowing, like opening a tap). The Bosch technician isn't helping, they say that it's customer's responsibility to get a proper pressure supply, he will just install the machine.
@@sumitchoudhary1499 have you installed pump between your overhead tank and other water circulation network like bathroom, washroom. Or pump is installed between water tap and machine water inlet. Please specify
What's the power rating in HP for this pump?
Hi, your video was helpful. We have the same Bosch washing machine and we have got vguard 0.24 hp booster pump. However, the machine does not accept water when the booster pump is in automatic mode. And it accepts water only when in manual mode. I'm afraid that this will affect our electricity bill. We can't figure out how to get the machine to work when the booster pump is in automatic mode.
1 small pipe add to delivery to suction for continue circulate water then it will work.
@@creatorsDesigns ok you can use NRV in suction line for pressurized and it will work in auto. Because auto will work only when delivery line is pressurized and it will off . Give me your email address I'll send you diagram of setup
You need to switch it off once the washing machine is off. If I am not wrong it will ruin the pump over the period of time.
Does it solved your problem?
No it did not. We keep the pump on, in manual mode as long as the cycle runs
Brother I would like to purchase it, can you specify the exact model details you purchased or share me the Amazon or flipkart link of the product
You have v-guard pmp:
www.amazon.in/VCB14-F030Automatic-Pressure-Suitable-Circulation-Washing/dp/B08QD2X657/ref=asc_df_B08QD2X657/?tag=googleshopdes-21&linkCode=df0&hvadid=396988570317&hvpos=&hvnetw=g&hvrand=8500245520655138535&hvpone=&hvptwo=&hvqmt=&hvdev=c&hvdvcmdl=&hvlocint=&hvlocphy=9062079&hvtargid=pla-1223069012326&psc=1&ext_vrnc=hi
Sir,
Can I install this pump near by Washing machine?
Because I want to use this machine for boosting water speed to Washing machine only. My water tank of 500 ltr only.
Therefore I also need to ask one more question to you :-
How much liter water it will be supply to Washing machine for 1wash (45 minutes wash)?
This is infact installed only for washing mashine. But since there is a wall you are not seeing that.
This is just 0.1 hp and can be contacted to one instrument
Usually washing machine will have lot of wash options. Water consumption will depend on that fact
At what height your tank is?
Mine tank is 8-10feet high above machine. Will it need pressure pump
Mostly you might need one.
Sir, bought Bosch washing machine series 6 1400 rpm. The person visited house for demo said it requires 1 hp pressure. In your video shown pressure booster pump works on said mentioned Bosch washing machine
It works for me I think it is more than 3 months it is working as expected.
I bought Crompton water booster for this Bosch washing machine it shows tap fault on auto mode works only on direct mode motor runs all the time you can't go anywhere while machine is on what to do with my new Bosch washing machine don't know😢
Same problem, Bought Crompton CIL120, it only works on Manual mode.😪😪
@@ahads90if works manual mode any problem plz tell me
Hi Sir, thank you very much for making this video. Could you please let me know As of now are you facing any issue with Motor Or bosch machine?? Any maintenance is needed??
BOSCH mahine will not have any issue with this. I have running the pump in auto mode for 2 years I never had an issue to date. Both washing and pump running fine.
Bro, can you tell me what size connectors you used to connect to washing machine pump and water inlet
Standard angle cock fittings size 1/2"(13 mm). You will get two connectors for the pressure pump. After the connector, you will need one connector to connect your washing machine pipe which will be available in most of the hardware shops. See these details in the below section of the video.
ua-cam.com/video/XamT1qeKt1A/v-deo.html
Which one should i consider for my washing machine btali or vguard?
I am using btali from past 2 years and it is working fine till this date.
@@gurucp2005 thank you. actually i bought it after seeing you video and it's work fine
Explained well 👍🙏
thanks sir
Does it still work fine now after 2 years?
It works great till date
i had also bought it for bosch machine , it is working very well without connecting to machine, but when we connect it to machine it is not working , if u know about it pls tell us
I think you put that in manual mode. Please make sure it is in automatic mode.
When the machine opens the water inlet solenoid it will automatically switch the pump.
does it have a filter option? water is not always clear, it has dust, grime, stone particles (rare)
It is not having filter. You will have to have one for your house water tank so that that will not get into the water pipe
You can have filter that will reduce the water pressure :)
Can water flow in reverse if Motor is off to fill the tank from other source
no
Sir, we have our tank just inside out flat at a mere height of say 2 metres hardly. Water pressure is very very low. Please guide what can help increas the pressure.
Above solution should work fine in your case too.
Sir i've got a Bosch 8kg front load washing machine, connected with 0.24 hp vguard booster on automatic mode but it shows low pressure warning while running, what should i do now? Please help
@@Ava-pp8fn yes sir now its not there, it was due to the air in hose, 0.24 hp booster vguard pump is working fine ... Check the connection of pipes and redo them
@@Ava-pp8fn get a pump dear, Bosch is the best one out there but all front load machines need high pressure water which can be obtained by a booster pump... Its a small waterproof pump and doesn't make any sond at all
@@Ava-pp8fn you don't have to change the machine
Is it working in auto mode?
Can you please send the specifications of pump you purchased, I brought Bosch washing machine front load.
And is the v guard pump working fine?
What is price bro... and where we get this
Brother same booster pump used my Samsung washing machine but automatic mode not working the booster pump. Please tell solutions
There could be some issue with the pump sensor. Get it replaced and check
I have same bosch machine and i am facing water pressure problem
How you solved it?
Hi, i just ordered the same from Amazon after watching your video for same use case. I just wanted to know whether it is delivering the mentioned water per min
Sir,
I do not have an instrument to measure this. But it is working with Bosch, that means it is at least delivering 10lpm.
@@gurucp2005 got it. thanks for replying bro.
Can u pls provide the item details or the link which u have ordered on amazon,
There is a problem with this setup.
The automatic pump will switch on only when water is flowing, but the machine will not let the water flow because it has low pressure. We need to keep the pump on manual mode as long as the machine is working. Not suitable.
It is running fine for almost from last 2 years. I do not have any issue keeping that in Auto mode.
@@gurucp2005 Thanks a lot for replying, I need help, this problem is giving me headache.
How high is your water tank from the machine inlet?
Mine is just 8-9 feet. I'm worried that automatic pump won't start because the washing machine won't let the water flow (I mean, the automatic pump starts only when water starts flowing, like opening a tap). The Bosch technician isn't helping, they say that it's customer's responsibility to get a proper pressure supply, he will just install the machine.
@@sumitchoudhary1499 have you installed pump between your overhead tank and other water circulation network like bathroom, washroom. Or pump is installed between water tap and machine water inlet. Please specify
Useful information 👍
Thank you 👍
Please share the product link, it would be more helpful
Same issue with samsung . Can you please what error you machine use to gave you ? I got 8CA2 and also machine use to get stuck after wash or rinse
It is mostly caused due to water inlet pressure. Please check your manual once. They will rate the inlet water pressure
Product link and how much cost
Does it work with Automatic Water pump mode?
mostly it will be automatic. But you will have manual switches too.
LG have this issue too. IE error.
This video is not showing the main problem even after installation of booster pump
What is that problem? Please tell
How much
What is the price?
Should be around 4 to 5k
3800
U installed the teflon tape wrongly first
Thanks for the suggestion. I am not a professional plumber hence the mistake. Will check that out