S Plan Heating Systems and 2 Port Valves - Plumbing Tips

Поділитися
Вставка
  • Опубліковано 5 вер 2024
  • This video covers s plan heating systems and 2 port valves. This includes their plumbing, their wiring, how they are controlled with time clock programmers and thermostats. For more information visit www.plumberpart...
    🚀 LEARN PLUMBING ONLINE IN MY STRUCTURED COURSE (50% Before March): www.learnplumbi...
    🛠 AMAZON TOOL STORE: www.amazon.co.u...
    🥾 10% Off my workboots + workwear Use Plumberparts10: www.bigboots.c...
    👓 10% Off Safestyle Sunglasses Use PLUMBER10: safestyle.com....
    Learn Plumbing Online is perfect for future apprentices, homeowners who want to understand and tackle more plumbing jobs in the home, handymen who keep turning down the odd plumbing job and more. With practical follow along video lessons and discussion board you can boost your knowledge in my amazing trade. Sign up now: wwwlearnplumbin...
    **VISIT OUR SPONSORS**
    www.traderadiat... | www.stuart-tur...

КОМЕНТАРІ • 98

  • @plumberparts
    @plumberparts  5 років тому +1

    *Links to the tools I use everyday here:* www.amazon.co.uk/shop/plumberparts
    Plus, follow my *Vlog “TimesWithJames”:* ua-cam.com/users/timeswithjames

    • @mpbuilder
      @mpbuilder 5 років тому

      Hi

    • @chargrill8019229
      @chargrill8019229 5 років тому

      Love your videos m8

    • @mohammedhussain3627
      @mohammedhussain3627 5 років тому +1

      Can you make a video that goes in depth with s and y plan as well as the wiring, I struggle to understand switch live and how to wire. If you can assist this will help me with my course. Thank you

  • @azhirb
    @azhirb 11 років тому +1

    Thanks for taking the time too make these videos it really helps as im newly qualified and makes it easier when I can double check with a pro....thanks.

  • @sdavies45
    @sdavies45 12 років тому

    You say who would want to work with a nutcase, but I think you would be quite entertaining to work with, plus anyone who did work with you would learn a lot!!

  • @PhilipBallGarry
    @PhilipBallGarry 8 років тому

    Excellent video again, especially as it helps us to understand the separate the electrical and water circuits and then their interdependence.
    The idea of making drawings and notes of the connections inside the box is good but these days most of us have a camera phone, so I recommend taking plenty of pictures too they make an excellent reference and reduce note-taking significantly. A picture after all, is "worth a thousand words" as my old geography teacher used to say :)

    • @plumberparts
      @plumberparts  8 років тому

      +Philip “Garry” Ball Good shout Phil and exactly what I do these days! PP!

  • @eazthitman
    @eazthitman 5 років тому

    instead of writing down cable arrangements I normally just photograph them on my phone :) Great vid and well explained thank you

  • @MrTrevorroe
    @MrTrevorroe 12 років тому +2

    Hi mate, the grey is constant live, the orang go's to boiler live, you show it the other way round on video.from Plumbing R&D and design TCC.

  • @maccagrabme
    @maccagrabme 12 років тому +1

    @blueskysivas Me too, there seems to be a million and one things to learn and that's after a lengthy college course. I think good plumbers are completely under rated considering the amount of knowledge they have to learn. Most people have no idea about what is required to become good at this, if they did they would realise that a good honest plumber is worth every penny.

  • @chargrill8019229
    @chargrill8019229 5 років тому +1

    I love this guy, finally a plumber that knows how the electrical side works.
    this guy is the dog bollocks!
    i really love all your videos, its nice to know the other trades when you do your job in order to work together in harmony and give the customer a top job!
    keep up the great work m8

  • @johnschlesinger2009
    @johnschlesinger2009 6 років тому +1

    Thanks for another good video. Krikes, there are quite a few dodgy joints and leaks on that system.

  • @samablewhite2273
    @samablewhite2273 7 років тому

    Thanks great video, really help in understanding how the wiring operates the valves, boiler etc.

  • @wojciechm7653
    @wojciechm7653 Рік тому

    Thank you for explaining

  • @jamief1979
    @jamief1979 12 років тому

    jamief 1979 cheers for the videos m8 ive nearly finished my lvl2 in plumbing and heating and hopeing to do my lvl 3 and gas afterwards your videos r gd to understand keep up the gd work

  • @dpacmall
    @dpacmall 9 місяців тому

    Can you please post a video explaining how to wire UFH that has different zones with an S plan that has radiator and cylinder zones. Thanks

  • @alanwilliams4835
    @alanwilliams4835 2 роки тому

    Love video it so well explained . Maybe you can help with my question if the boiler has pump over run on a combi driving 2 two port values rads & underfloor heating and valves have just shut the pump in the boiler will not be able to pump the water.

  • @rajnirvan3336
    @rajnirvan3336 4 роки тому

    Those kind of connecter blocks and boxes for this method of wiring are going out. New kind of connectors that are made by Wago which hold the wires with levers and save time using screw connectors

  • @BenKinslowGuitar
    @BenKinslowGuitar 2 роки тому

    Great Video, 2 questions… 1. When balancing an s plan do you do the whole house as one or each zone separately? And 2. Should I adjust the gate valve on the back end of indirect cylinder to reduce the flow and slow the water.

  • @19alpesh09
    @19alpesh09 4 роки тому

    You know what one thing your are STAR

  • @RobertRobbinsvideomarketing
    @RobertRobbinsvideomarketing 6 років тому

    Great video as usual, I have an issue with an S Plan, just changed the HW zone valve having previously changed the pump a year ago. The HW Zone valve removed was a Satchwell which clearly had an historic slight leak, over the years corrosion set in so I cannot see the flow direction arrow on the old valve. So I pointed the flow at the lower cylinder junction 22mm which I think is right, but now the HW only gets warm, it used to get very hot because the old valve was stuck fully open, I need to clearly see a flow direction diagram, your video runs through it but as this is a 2007 Baxi install it appears somewhat different as it tees off between the two zone valves. After all that a full water flow direction video would be a great Idea - no-one has done one yet so it should get a few views :-)

  • @abzimaj
    @abzimaj 9 років тому

    Hey James just a request if possible. Explain the difference between s plan and y plan and how to decide which system would be best to install.

  • @chrishinds1762
    @chrishinds1762 2 роки тому

    Nice one mate

  • @TheDickPuller
    @TheDickPuller 13 років тому

    Another good video mate, keep up the good work.

  • @joela8437
    @joela8437 4 роки тому

    Great clear video, however I was wondering what is your take on putting the Zone valves on the return of that zone as the water temperature is lower?

  • @soonminewman
    @soonminewman 10 років тому

    Great video Tom. Nailed it.

  •  7 років тому

    I think I get it now. The cylinder could be full of cold water but it's cylinder stat wont kick the boiler , pump or motorised valve in to gear until the programmers hot is set to on manually or programmed to come on at a certain time. All in the correct circuitry of which I should understand a bit better now I hope.

  • @ramesh046
    @ramesh046 11 років тому

    Your explanations are so informative!My friend just fitted Honeywell 3 port mid pos valve.as the hot water was not being diverted.
    All is fine now except I get this whirring noise(from the Pump?) now and then. Whats the problem please

  • @petinyiri
    @petinyiri 8 місяців тому

    hi great video, on our system, the orange and grey wire aren't connected to anywhere, only earth, the neutral, i see there 3 blue wires connected together (one is from the valve motor), then the 3 of the earth wire (one is the motor wire) , and then i have two brown connected together, but of the 2 way valve the brown is connected alone in the terminal box, should this valve motor brown wire connected with the other two? any tips?

  • @cmodyssey
    @cmodyssey 11 років тому

    Great video clip. One question, is there a diagram or could you do a quick diagram showing the "Three Tees Rule". Much appreciated :)

  • @mpbuilder
    @mpbuilder 5 років тому +1

    Hi buddy u nailed it awesome G.I have 6 zone's heating system and I wanna add 3port manifold for individuals room thermostat's with 2port zone valves have you got any plans for it please can you help me out ThnkuuM+P Builders contractor

  • @101nagen
    @101nagen 13 років тому

    Hi ya mate just wondering that house your in is it a thatch cottage?? on a huge bit of land? Looks so much like my Aunties old house.

  • @dalriada842
    @dalriada842 12 років тому

    Is there any advantage to using a fibre washer, over a rubber one? I've never been able to get fibre washers to seal properly. Do you have any videos on using them? I don't see any looking down the list, b

  • @XXXBootstrap
    @XXXBootstrap 13 років тому +1

    Love the vids, mate!

  • @CmwSpeedrunUk
    @CmwSpeedrunUk 5 років тому

    Been told about your channel , it’s perfect 👌🏽

  • @AWPS-LTD
    @AWPS-LTD 5 років тому

    Think you got the Permeant & Switch Live the wrong way round. Maybe a tad of a leak on the Pump Iso's...

  • @SICK0z
    @SICK0z 9 років тому

    very helpful, thanks

  • @BakedTuber
    @BakedTuber 3 роки тому

    I want to install zoned heating in my new home. I'm thinking Honeywell T6's in each room and 2 port valves to control the flow to convector radiators. Is this a good idea or should I be installing an underfloor heating style manifold?

  • @peterryan7827
    @peterryan7827 6 років тому

    More good stuff thanks again,Yes its very interesting and usefull.

  • @muhammadadeel4760
    @muhammadadeel4760 6 років тому

    Hi
    I got ufh and radiators. To seprate them I did put 2 port motorised valve for both. But question I would like to ask is, do we put any thing (valve etc) on return side ?

  • @MJS-3000
    @MJS-3000 5 років тому

    How does this factor in to zone valves on underfloor heating where the zone is still calling for heat but the underfloor circuit is self circulating due to be up to temp. Does that not cause pressure issues?

  • @TheDickPuller
    @TheDickPuller 13 років тому

    @taitlawrence That's good mate, good luck with getting a job. Having your ACS & a driving licence is a must. So stick with it...........Do what I've done in the past, as a young man, when site work dried up; I worked as a Joiners mate, Brickies Labourer & even did 6 months as a Dryliner. All great experience.
    Keep looking & with your apprenticeship you've always got a foot in the door...........;-)

  • @jayvee0404
    @jayvee0404 7 років тому

    Great easy to follow video. I have an S plan system and have reason to think the synchron motor on one of the V4043H 1056 two port valves is not working properly (doesn't seem to switch the micro switch). So before investigating further I thought I'd replace it. Now the thing is I have a spare which I've had for quite some time (from previous house) - it has blue wires so suspect it's a genuine Honeywell, it's made in USA, and on its surface is stamped (in ink) Honeywell F5-9311. So what I'd like to know is if it would be compatible with my zone valve. Would it hurt to try? Perhaps all synchron motors are the same? I'd be grateful if you can advise. Thanks :)

  • @RaptureUK1
    @RaptureUK1 5 років тому

    I have just traced out my heating system in my new home (old 50s house) which is S plan. Runs of a Rayburn, pump, hot water tank but has no 2/3 port valves. It just tees off for rads and storage tank. Does this seem normal? Think it has a stat attached to the outlet Rayburn pipe to kill the pump on setpoint (75C)

  • @abinjain3320
    @abinjain3320 11 років тому

    my central pressurised heating system was automatically working past few years.Now problems is that it is not working according to time programmer.fist both hot water and heating system are to be switched on manually and any one to be switched off ,other is tripped and started to working.could you give an advice on this problem at an earliest.

  • @djzali2311
    @djzali2311 4 роки тому

    Hi...I have a problem with Center 2 Port Motorised Valve 22mm I don't know if is a problem with the head or valve I changed just head ( not valve ) for new one and I found this problem.
    When I turned on the water for heating the Lever stay in position not moving( motor works ) but my central heating works as well even though it is turned off
    When I turned on central heating the Lever changes positions to the top ( I think this is like should be ? I have right or not?)
    The valve wasn't stiff I easy turned by my fingers
    Pls give me any advice's Thank You

  • @bluebay1000
    @bluebay1000 12 років тому

    Thank you geez

  • @lordbyrom100
    @lordbyrom100 2 роки тому

    How does the pump and boiler “run on” till all the boiler heat is dissipated??????

  • @rangewarwick
    @rangewarwick 5 років тому

    Great video and channel. Could you explain what the pump overrun is please. The reason I ask is because I have had a new Worcester Bosch system boiler fitted and there are now strange hissing noises coming from the hot water cylinder when programmer switches off the boiler, or when the central heating thermostat switches off the boiler. It is as if the pump in the boiler is still on, but there is nowhere for the water to circulate (due to the valves on the S plan system being closed). The noises stop when the pump switches off after a couple of minutes.

  • @ansarjaved4561
    @ansarjaved4561 7 років тому

    After some advise as I haven't a clue , would like your feedback as to which is the best way to create this heating&shot water system, thanks in advance, 4 zones, x2 heat up and down X1 underfloor heating and hot water zone. AJ

  • @balpun6785
    @balpun6785 11 років тому

    hi.how do u rectify the problem like when switch on my heater or water near the tank but the boiler downstairs keep on turn on and off for 3 min off then on and off.so the water and heater is not working as it suppose to be..

  • @websurfer1585
    @websurfer1585 3 роки тому

    To my mind, s plan is so much better than y plan, so this begs the question, why have a y plan system, when it's more complicated to diagnose faults, and more prone to problems?

  • @keithowen755
    @keithowen755 4 роки тому

    I understand the zone valves are 24v so where is the transformer located.

  • @steveb1086
    @steveb1086 6 років тому

    I have a similar set up in airing cupboard. Can you advise plz .. programmer off for hot water but pump is on 24/7 and I get hot water . I think the 2 port valve is sticking, boiler clicks off and on all day. Should I get the valve changed ? Ta

  • @MH-qu1cv
    @MH-qu1cv 7 років тому +2

    Hi there, I'm a sparky. Have you ever come across systems with no port valve just a room thermostat, boiler, pump and cylinder stat?
    great vids by the way.

    • @plumberparts
      @plumberparts  7 років тому +1

      Yes....and they are poo. Often just use a live to a pump to divert to where it's needed. SUBSCRIBE! ➡️👉 ua-cam.com/users/plumberparts 👈⬅️ IF YOU HAVEN'T ALREADY! 😎

  • @markullyett
    @markullyett 6 років тому

    When I just have my hot water on my radiators are getting red hot. Does it mean one of my valves is faulty?

  • @FiratHira
    @FiratHira 7 років тому

    Do S-plan unvented systems NEED an automatic/manual bypass valve for pump overrun (cool the boiler)? Whats the consequence of not having one? Thanks

    • @plumberparts
      @plumberparts  7 років тому

      They do. Good shout!
      Sub here please➡️👉 ua-cam.com/users/plumberparts ➡️👉FOLLOW US ON TWITTER! TRYING TO GET MORE FOLLOWERS! 🐤👉 twitter.com/plumberparts 👈🐤

  • @lascar48
    @lascar48 5 років тому

    Hey James, when the valve micro switch fails to switch off (as it does frequently) when the valve closes, the burner is on constantly with both valves closed. Must a radiator be piped independently of valves to prevent an explosion?

    • @SpNick3
      @SpNick3 5 років тому

      lascar48 use a bypass valve

  • @kirdag17
    @kirdag17 7 років тому

    lovely

  • @adambibby58
    @adambibby58 8 років тому

    my central heating at the moment is split into 2 zones and to turn each zone off I manually go to boiler and turn a valve, works a treat but annoying. I happen to have an electric valve handy, do you think it would be possible to wire it up to the mains? I have a WiFi switch on the mains so the theory is I can turn power on and off to the valve?

    • @plumberparts
      @plumberparts  7 років тому +1

      Just use a normal s plan heating system set up! SUBSCRIBE! ➡️👉 ua-cam.com/users/plumberparts 👈⬅️if you haven't already!

  • @richardsawyer1532
    @richardsawyer1532 8 років тому

    Permanent supply is on the grey cable and switched supply is the orange cable

    • @plumberparts
      @plumberparts  8 років тому

      +Richard Sawyer True, although it doesn't actually matter, they can be on either way round! Cheers, PP!

    • @richardsawyer1532
      @richardsawyer1532 8 років тому

      Yes I agree it is just that we usually use the orange as the switch wire.

  • @matthewitt1973
    @matthewitt1973 10 років тому

    Great videos. I have a 2 port and when it is activated for heating the switch WILL NOT stay in the manual position. Is this a microswitch thing? Can you replace just the switch as the unit is an old Honeywell so I can't just replace the head? Thanks.

    • @plumberparts
      @plumberparts  9 років тому

      Matt Hewitt Does the heating stay on? Regards, PP!

  • @A.RR24115
    @A.RR24115 6 років тому

    Hi mate
    I have hot water cylinder with 2 port valve it's gravity system. The hot water only come if I turn (heat/ hot water ) option in the programmer and when I put on (hot water only ) the boiler not firing.
    Plumber came and changed my programmer but the problem still same
    Any advice pls?

  • @boilers24-7
    @boilers24-7 7 років тому

    Can u do a video on room thermostat and the connection n where it goes etc specifically EBERLE RTR E 6121 thanks

    • @plumberparts
      @plumberparts  7 років тому +1

      Mate if I did a video for every boiler I'd neveer make any other videos! What problem do you have? Send me a message via my Facebook or Twitter page....links in the description!

  • @knightsofclonmore
    @knightsofclonmore 8 років тому

    Do you bleed the system when you are replacing the 2 port valve ,as my is upstairs.Would there be water in it as its a sealed system?

    • @plumberparts
      @plumberparts  7 років тому

      Yes mate! Sorry for the delay in replying!
      Sub here please>> ua-cam.com/users/plumberparts

  • @112sharmans
    @112sharmans 8 років тому

    I have a 2port salus faulty valve, plumber advised me to run without it for now and allow hot water to flow through so we can have the underfloor heating on, is this ok to do? will it cause any damage until I get a replacement? thanks

    • @plumberparts
      @plumberparts  8 років тому

      +112sharmans Shouldn't do, just turn boiler temp down. PP!

  • @chrispugh2450
    @chrispugh2450 7 років тому

    if you got no hot water , how do you tell whether its the port valve that aint working or the boiler stat!!!.

  • @firpoalan
    @firpoalan 10 років тому

    Wheel tappers and shunters

  • @zebakhtar4022
    @zebakhtar4022 8 років тому

    whats the wiring layout when adding additional 2 port valve please?

    • @plumberparts
      @plumberparts  7 років тому

      Check it out online mate as we have not done one yet! Sorry for the delay in replying!
      Sub here please>> ua-cam.com/users/plumberparts

  • @angle4385
    @angle4385 6 років тому

    Need help im an trainee electrician trying to help fix my dads simply but confusing hot wate cylinder thermostat that wired direct to a 2 port motorised valve the plan is when hot water tank reach heat that will power valve to provide more hot water to radiators please help can supply pictures

  • @leehenry8608
    @leehenry8608 2 роки тому

    👍

  • @VOICEofTRNC
    @VOICEofTRNC 12 років тому

    You da man

  • @yusufrehman2157
    @yusufrehman2157 5 років тому

    Good please brief in more easy way Sand Y plain

  • @ifracing
    @ifracing 6 років тому

    Surely there should be pinholes in that copper by now lol

  •  7 років тому

    Excuse my ignorance but why would the programmer be telling the cylinder it needs hot water. shouldn't only the cylinder know when it needs hot water. For example the way you explained it you said the programmer is telling the cylinder it needs hot water. Well what if the cylinder tells the programmer that it does'nt need hot water.

    • @taitlawrence
      @taitlawrence 5 років тому

      the programmer calls for heat and sends a signal to the stat, if the stat isn't satisfied it will send a signal to the zone valve to open

  • @TheDickPuller
    @TheDickPuller 13 років тому

    @taitlawrence Are you time-served son?? We always got jobs for good time-served Plumbers, never employ course cowboys(CC) or career change chancers(CCC).

  • @dalriada842
    @dalriada842 12 років тому

    My last comment is posted on the wrong video! Curses on the ipad UA-cam app!

  • @scott1506
    @scott1506 4 роки тому

    i dont see any S

  • @tinker-time
    @tinker-time 5 років тому

    how do you wire under floor to a combi, doing my fucking head!! now

  • @davidtassell2222
    @davidtassell2222 4 роки тому

    Music

  • @taitlawrence
    @taitlawrence 13 років тому

    Any jobs going :l

  • @lostinthoughtscalminsilenc8167
    @lostinthoughtscalminsilenc8167 10 місяців тому

    Some have white?