Advanced Level Grounding Discussion for All-in-one Solar Power Systems

Поділитися
Вставка
  • Опубліковано 23 сер 2024
  • All in ones that I recommend: www.mobile-sol...
    Does off-grid solar confuse you?
    Check out my DIY friendly website for solar system packages and product recommendations, and so much more! www.mobile-sola...
    Join our DIY solar community!
    #1 largest solar forum on the internet for beginners and professionals alike:
    www.diysolarfo...
    Check out my best-selling, beginner-friendly 12V off-grid solar book (affiliate link):
    amzn.to/2Aj4dX4
    If DIY is not for you, but you love solar and need an offgrid system, check out EnergyPal! They will price out a system and get your house offgrid: energypal.com/...
    My Solar Equipment Recommendations (Constantly updated! Check here first):
    12V/48V Lithium Batteries: www.mobile-sol...
    Solar System Component Directory: www.mobile-sol...
    Complete 48V System Blueprint: www.mobile-sol...
    Plug-N-Play Systems: www.mobile-sol...
    Complete 48V System Kits: www.mobile-sol...
    DIY Friendly Air Conditioner/ Heat Pumps: www.mobile-sol...
    My Favorite Online Stores for DIY Solar Products:
    Signature Solar
    Offgrid One-Stop-Shop. Best Value 48V LiFePO4, Victron and Offgrid Specific Heat Pumps:
    www.signatures...
    Current Connected
    SOK, Victron, Mr.Cool Heatpumps and High Quality Components:
    currentconnect...
    Ecoflow Delta
    My favorite plug-n-play solar generator:
    us.ecoflow.com...
    AmpereTime
    Cheapest 12V batteries around:
    amperetime.com...
    Renogy
    A classic 12V solar store that has been around for ages!
    renogy.sjv.io/...
    Rich Solar
    Renogy's biggest competitor! Similar products, but at a better price:
    richsolar.com/...
    Battery Hookup
    Cheap cell deals
    bit.ly/2mIxSqt
    5% off code: diysolar
    Contact Information:
    I am NOT available for personal solar system consult! If you wish to contact me, this is my direct email: williamprowsediysolar@gmail.com
    Join the forum at diysolarforum.... if you wish to hang out with myself and others and talk about solar
    FTC Disclosure Statement and Disclaimers:
    Every video includes some form of paid promotion or sponsorship. Some links on this youtube channel may be affiliate links. We may get paid if you buy something or take an action after clicking one of these. My videos are for educational purposes only. Information is subject to change/update at any time. Electricity is DANGEROUS and can kill. Be smart and use common sense :)
    DIY Solar Power with Will Prowse is a participant in the Amazon Services LLC Associates Program,
    An affiliate advertising program designed to provide a means for sites to earn advertising fees by advertising and linking to Amazon.com

КОМЕНТАРІ • 405

  • @williamfigueroa6503
    @williamfigueroa6503 Рік тому +42

    Just wanted to congratulate you. Even licensed electricians get this subject wrong. I’m a master electrician with 23 years experience in the field and I see this confusion with the earth ground way too often. Thanks for spreading the right information on your channel. Keep up the good work.
    Great video!

    • @damageben8325
      @damageben8325 Рік тому +5

      HI william, i have a 5kw hybrid inverter. its charges my 48v battery and can put out 5000watt AC.
      when i switch on the AC output, the frames of my solar panels start tot have around 50VAC power on them. i even can get a shock from this.
      when the AC output is switch off. nothing is wrong and the pannels stay safe.
      do you have any idea what i have to do to fix this? i relly hope you can help me. thanks

    • @readoryx373
      @readoryx373 8 місяців тому

      Same setup/scenario as above. I'm feeling very confused about things, going to disconnect my ground rod and also the ground/neutral bond wire at Service Panel (which is main panel, off grid no AC Input with a Chinese Hybrid Grid tie inverter) except for a sole earth ground connection at battery negative. I have more to read about positive grounding before dabbling.

  • @john_in_phoenix
    @john_in_phoenix 2 роки тому +46

    This is a very complicated subject that even has many professional electricians scratching their heads. I would encourage more in depth coverage of the subject (that even I get lost on).

    • @VinceBadovinatz88
      @VinceBadovinatz88 Рік тому

      I totally agree I know nothing about grounds or grounding

    • @ahmadkhan3276
      @ahmadkhan3276 Рік тому +2

      It is not that difficult, this just common mode, engineer tends to use complicated words that makes a mess

    • @RetroElectric
      @RetroElectric 7 місяців тому

      Yes. More coverage needed. What to do with the ground because the wrong thing can be done in an attempt to do it right. What in the heck is the purpose of the ground on these inverters. The fact there isn’t even a slight suggestion in the manual makes it worse.

  • @wgoode505
    @wgoode505 2 роки тому +29

    One, That's how many ground/neutral bonds we need. With grid power input on an inverter or multiple inverters in this case. And that is already done at your main panel or meter panel. One ground location per service structure, now requiring two rods a minimum of 6 feet apart at the first means of disconnect. And in a separate structure (out building) sub panel or even a sub panel in your house never interrupt or divert your neutral or insulated ground from going back to the power company transformer. Meaning never give it an alternative path (ground bond to secondary ground rod) from getting back to the power company transformer. Because your sub panel in a separate structure does now require a ground rod also. And that's death waiting to happen if bonded. For example, your "incoming" ground, 4th wire, in any sub panel is a "ground fault current path" back to the transformer if the neutral gets broken or is shorted to either hot leg and, it must be insulated, not bare. Only your main service entrance wires from the meter to first means of disconnect can use an uninsulated ground. All this is another reason why separate auto transformers should never be used and should be banned if grid power is used on the inverter. In low frequency inverters with their own transformer they are protected if a neutral is lost, the inverter will shut down output AC power. But not separate auto transformers. Ever wonder why there is no breaker or disconnecting means on a neutral, death is why. Neutral IS A CURRENT CARRIER all the way back to the transformer and from there, all the way back to the generator at the power station. And ground rods just dissipate some of that current draw on its way back and keeps the voltage at zero between neutral and ground. It takes a completed loop to use electricity. If you interrupt that neutral path back to the transformer and send it to ground you can be shocked and everything attached to your ground bars in your sub panel will be energized. Be safe. Everyone has this false sense of safety when it comes to grounds, ground this, ground that, ground here, ground there when in fact a ground can be just as much deadly as it is safe. Mike Holts videos are great to watch he shows you exactly how people are being killed by not understanding neutral/ground bonds and ground fault current path. Great video and topic Will.

    • @billjaeger4839
      @billjaeger4839 Рік тому +1

      Dude! Thank you for this information AND especially directing us to Mike Holtz!!!

    • @JohnDoe-pv2iu
      @JohnDoe-pv2iu Рік тому +1

      Mike Holz is a great resource. It's funny though how even Very knowledgeable people's perspective evolves, if you look at his videos over time. In earlier videos he is against multiple ground rods (not tied) and he is right. Later, there is a video where he and a Power company employee installed 2. 50 foot ground rods that were tied with 6 gauge copper and they tested it. They point out how low the ground resistance is and how much SAFER this setup makes the electrical system! Great resource.
      Ya'll Take Care and be safe, John

  • @cybertrk
    @cybertrk 2 роки тому +38

    This is why right to repair is important, actual board schematics need to be public even just for safety of the end user.

  • @samdorchester2524
    @samdorchester2524 2 роки тому +6

    I am no electrician but I was in the dairy industry and when wiring a milking parlor all sub panels ground and neutral wires were to be separated. If they were not it caused a condition called stray voltage which harmed the animals. If I remember right the only place they are connected is at the main panel because all power eventually the power goes back to the power stations. We did have some cases where there was power coming back to the farm by the ground wire, then the power company would have to add more pole grounds. This probably don’t shed any light on the subject but that was my experience in grounds and neutrals.

  • @ashforkdan
    @ashforkdan 2 роки тому +21

    After a lighting strike that went up my ground rod and fried my inverter I talked with a home power engineer and explained how the ground here has coleagy "water proof ash" 12 inches down and the rain sits on top of it and the lighting hit the ground and went up my ground rod and straight to the inverter. He said to disconnect it and only use the battery ground. It's been 28 years now and lots of lighting but no more problems.

    • @coreydean9277
      @coreydean9277 2 роки тому +1

      Are you saying to ground the inverter chassis to the Negative of the battery?

    • @VinceBadovinatz88
      @VinceBadovinatz88 Рік тому

      @@coreydean9277 I wonder sounds kind of like what he's saying

  • @cotandiet6096
    @cotandiet6096 Рік тому +4

    Introduction: Each inverter has its own current flow path, each one needs a reference ground point and a short current path. Two of them are combined to make a split phase system which shared the neutral wire. In this split phase system, current flows from each hot wire of it's own inverter and return back itself through the neutral wire. The ground is for reference point and a short current flow path. If the voltages of two hot legs are different, there will be current flow from one inverter to the other, does not matter you have one or two ground-neutral bond(s).
    1. For transfer mode (Inverters using power from grid to supply power to the main panel by built-in relays), ground-neutral bond should be at the first panel (after the meter). This was already done when you have electric meter installed. The inverters are using ground-neutral bond from grid, this is correct. Do not create any ground-neutral bond to any panel in your house.
    2. For off-grid, the ground-neutral bond should be at the inverters (grid neutral wire should be disconnected). If in case there is a short, the current flow will be terminated at the inverters. Remember, ground-neutral bond is used for reference point and short current flow path. One ground-neutral bond will work, but two are better. Current loop occurs only if your neutral wires are so small and two inverters are mounted far apart (long distance). For conclusion, keep the ground-neutral bonds on all inverters. You cannot count all inverters have bonding as multiple points, it is still single point of bonding because they are together as one power source.

  • @danfitzpatrick4112
    @danfitzpatrick4112 2 роки тому +5

    I made a video showing this ground /neutral issue last year on my channel. The neutral should only be bonded at the main panel but there is still an issue with these inverters and the only way this could be fixed in my thoughts is upon transfer the ground and neutral bond should change it's state at that point.
    I was in contact with the MPP solar engineers and they even watched my video, but I couldn't get them to understand the issue.
    The reason these are wired like this (I was told) is that these are shipped to many places with varying code requirements.

  • @Vigo327
    @Vigo327 2 роки тому +4

    I'm glad you're working through this. I'm totally comfortable with DC systems but have to work my brain pretty hard to figure out grounding issues during this brainstorming phase of an offgrid system i hope to build in the coming months.

  • @Raphael_Hofmann
    @Raphael_Hofmann 2 роки тому +15

    I know from the Victron Inverters, that there is a ground relay, that automatically bonds ground and neutral in inverter mode.
    The relay opens, once a AC input is connected. But the ground relay can also be disabled in software.

    • @WillProwse
      @WillProwse  2 роки тому +16

      Yes, everyone should copy victron. I am working with one of their inverters right now and the ground relays are fantastic. Fixes all of these issues.

  • @michaelcotherman2402
    @michaelcotherman2402 2 роки тому +2

    Great explanation and demonstration, this is much better than a 'code-parrot' just repeating NEC ad-nauseum... You showing and talking through the thought process is extremely helpful to all viewers. Ground loops that close with that big of wire are not nearly as bad as ones with a long run between them, and would probably never have any issue in your lifetime, but for continuity(pun intended), following a standard is best. Thank you for your work.

  • @TerrydeAlaska
    @TerrydeAlaska 2 роки тому +1

    The neutral and ground are tied together and bonded to the transform on the pole. The neutral and ground are tied together and bonded to metal and connected to a ground rod at the main service disconnect feeding your house. The inverter would normally float the neutral ground connection on pass-through of utility power and bond them on an outage and switch internally to disconnect from utility power to inverter power (produced from the batteries) and also in the same switch tie the neutral to ground. This is why it's important to ground all metal cases on an inverter. It's great to see you diving so deep on this issue.

  • @noelburns4512
    @noelburns4512 Рік тому +4

    Thanks Will as I have been of grid for thirty years and to earth at inverter and distribution panel made no sense and equipment suppliers were vague about this also. All information I read or watched stated to ground but I decided for the reasons you outlined to use the "floating earth" at the equipment end. Using the Inverters internal GN bond. And to quote part of Chris's comment " The reason we don't bond them in subpanels isn't to avoid ground loops, it's to avoid neutral current being carried on the ground conductor". Finally getting some sense on this important issue.

  • @ShaleAudio
    @ShaleAudio 2 роки тому +19

    I agree and this was a concern I had recently when setting up a system, because there are many systems that don't specify this but when you test you find it to be true. This is exactly the reason why the NEC says not to have a neutral ground bond in sub panels

    • @ShaleAudio
      @ShaleAudio 2 роки тому

      @@realnealsmith my limited understanding is the differential between the ground rods causing a voltage difference that is more dangerous than the previously accepted lack of bond

    • @dean5263
      @dean5263 2 роки тому +4

      @@ShaleAudio Think of it under an extreme condition like lightening, there is a tremendous voltage difference in just a few feet from the strike point across the ground, if you have two separate ground rods then those points have a potential voltage difference from just the static electricity in the air.

    • @boloren
      @boloren 2 роки тому +1

      @@dean5263 doesn't nec require two grounding methods (ie: two rods 6'+ apart, one rod + metal water pipe, one rod + ufer, etc)? (practically speaking, since it's not reasonable to prove the ground resistance of

    • @lukefarmer5391
      @lukefarmer5391 2 роки тому

      People, remember true earth ground,” grounding rods” is ONLY for lighting protection. Period. That’s it. Multiple grounding rods is a fire hazard if lighting did strike and travel through that ground circuit or energy from around the ground from a strike traveling through the ground circuit. Plus you could get cross arching that cause’s the fire and death or burns to anyone in between. In addition it would most likely fry any electronics connected to it. This has been a documented fact when they use to earth ground huge cnc machines years ago.

  • @stevejagger8602
    @stevejagger8602 2 роки тому +4

    This is an excellent article on grounding, with particular attention to lightning protection, a much neglected aspect of all types of solar pv installations.

    • @tywheeler7131
      @tywheeler7131 2 роки тому +1

      It amazes me how often lightning isn’t addressed in grounding considerations. Most folks just float the whole thing, but I have metal vintage camper. It’ll light the whole thing up like a Christmas tree if I didn’t create my own grounding system (which I have).

  • @McTroyd
    @McTroyd 2 роки тому +3

    I'm no electrician, but I was always taught that, so long as you only had one ground for a common rail, it didn't matter which ground point it was. Ground loops are only an issue when multiple points are grounded differently, and there's potential between them due to the varying resistance. On a small system like this one, I'd probably stick with an earth ground in the panel so all my disconnection points are in one place. If all the (edit: ground points) are connected together, and only one point is actually grounded, I don't know that it matters. 🤷‍♂️👍️

  • @davidhyman4541
    @davidhyman4541 2 роки тому +7

    Grounding is a multifaceted beast, and has many different implication as whether it is AC or DC and/or even RF. An electrical diagram will show many items tied to ground rather than draw out the wiring for a ground wiring path. In AC circuits it typically refers as a chassis ground to bleed of static and provide a path of least resistance when/if the device has a short.
    When we get to Inverters and especially the All-in-one units, it is recommended we treat them as a sub-panel. This Video shows the wiring and use of the sub-panel giving detail for ground and neutral connections. The ground wire is to provide a chassis ground to the cabinet of the invertor. When the AC loads are connected to the Inverter with a sub-panel the ground is still for Static and Chassis connections and not a current wire, the sub-panel passes the ground back to the main service panel and connects to earth with its bonding. The bonding of the main panel to earth is primarily to prevent lightning entry.
    When you connect your batteries to your invertor they are completely isolated from all AC connections and bonding. On your Battery you can have a Negative Buss Bar to connect all the DC negative connections together. Never connect the batteries to earth ground, should the invertor generate a short you could send AC through the batteries and have an explosion.
    Off-grid systems are wired with a sub-panel also, but as it does not have a main panel with a ground bonded to create the static/chassis connection we need to connect this panel to a ground rod to give that static/chassis connection. We DO NOT bond this panel! Again the Ground and Neutral in this sub-panel are NOT connected. Your Neutral wire is a current carrying wire to complete the circuit, the ground is for Static/Chassis and helps the circuit trip when there is a fault.
    When paralleling units in a 120v configuration, connect only the Line1 together and then only connect the Neutrals together. Your Neutral is your return current wire in powering the circuit.

    • @VinceBadovinatz88
      @VinceBadovinatz88 Рік тому +2

      Thank you that really does sound logical I have to read it 10 times try to get it through my brain

    • @davidhyman4541
      @davidhyman4541 Рік тому +1

      @@VinceBadovinatz88 glad it helped

  • @knuth42
    @knuth42 2 роки тому +12

    Grounding in split phase systems can rapidly become confusing, particularly when there are subpanels in detached structures involved; in such cases NEC Article 250 *requires* a distinct grounding electrode in the detached structure, although a single *load* in a detached structure can be fed from another panel without need for a local grounding electrode. All electrodes must be bonded together (so they're unipotential at low frequencies -- all bets are off in the low megahertz range, as you'd see with a lightning strike). If you have RF systems like me, a perimeter ground and single point ground panel get added to the mix, so I have electrodes (two each) for all of my outbuildings (including the one with all of the PV gear) tied together with buried #6 that surrounds the compound and ties into the SPGP for the antenna systems.
    This relatively straightforward issue gets massively confused when using UL-approved inverter-chargers. UL 458 *requires* that inverter-chargers with integrated transfer switches bond neutral to ground when running off of battery or the PV array, but not bond them (for obvious reasons) when powered from AC-in.
    A lot of this complexity is a consequence of the fact that the US uses ground both to dissipate charge build-up (earthing), and to clear faults. The latter is why we bond neutral and ground at the service entrance; fault current on ground will trip the protection device and clear the fault. The reason we don't bond them in subpanels isn't to avoid ground loops, it's to avoid neutral current being carried on the ground conductor. Note that none of this has anything meaningful to do with lightning protection; minimum conductor side for lightning protection grounding is 1.5 to 2 inch 16 ga. strapping.
    I suspect the LV6548 ships (sometimes) with the bonding screw installed is because not every country does things quite as whacky as the US. It just would have been nice if it had been in a more...convenient...location.

    • @WillProwse
      @WillProwse  2 роки тому

      You should join our forum. Diysolarforum.com
      Made a new video with ground neutral bonding discussion, now have the bond screw removed

    • @nspireConnection
      @nspireConnection Рік тому

      Us Building Biologists call this net current : "The reason we don't bond them in subpanels isn't to avoid ground loops, it's to avoid neutral current being carried on the ground conductor," parallel paths cause imbalanced return currents to occur because electricity takes all paths back to source (transformer of power company). This is serious code violation because a AWG 14 lighting circuit wiring isn't designed to carry more than 15A, but it can when commingled neutrals from another other branch circuit that is rated at 20A and uses AWG 12.
      Three way stairwell lights often have this issue, and although the switches work, the wrong gauge wires might be smoldering inside the wall, and that's why it must never be done. Yet some 80% of homes have N-N issues or N-G miss wiring issues.
      We trace these complicated to isolate wiring errors in junction boxes, by means of magnetic field meters, as such looping (where they shouldn't) AC currents generate large and deleterious magnetic fields

    • @deadeyecustoms1500
      @deadeyecustoms1500 10 місяців тому

      This is exactly the headache I've been having with my split phase system. My solar shelter is located about 75ft from my shop. I have a panel inside the shelter powering the ac inside the shelter & a Native DC split providing climate control for my battery bank, that's connected directly to my bus bars. I then have 75' of 2awg running to my "main panel" for the shop. My PV array is on its own grounding rod & I had my shelter on its own grounding rod & also one at the shop panel. After watching this video, I think I don't need my shelter on its own grounding rod & instead have a floating ground/neutral bond in the panel inside the shelter. Everything has been working fine. My shop lights are now powered by the shop panel, but when I started flipping on outlet breakers, I got an output fault at my inverter. I had the feeling it had something to do with the grounding possibly making a ground loop, even though I'm completely off grid. My shelter panel isn't ground neutral bonded, yet my shop panel is. I only have power wires running to my shop panel without a ground wire connecting the two panels. I'm not an electrician & basically youtube'd my way through this massive project. I live in the mountains & it's impossible to get a solar professional out here to look over my system for safety. If you have any advice for my set ups grounding, I would be in your debt. I'm running a 28kwh 13000w split phase off grid solar setup, but my particular set up with my solar shelter being 75' from my shops panel is confusing. My shelter is a refurbished Korean era military radio shelter. It's a metal box with aluminum mesh lining for faraday protection I assume.

  • @WillProwse
    @WillProwse  2 роки тому +18

    I contacted MPP and they agreed with my conclusions in this video. Keep grounds and neutrals separate. Treat it like a sub panel.
    When ac output is in series, the bond between neutrals needs to be perfect.
    Furthermore, only tie earth ground to ac input. Not the panel. If you connect the panel instead, you must ensure that the ac input is not used.
    ~~~~~~~~~~~~~~~~~~~~~~~~~~~~
    Does off-grid solar confuse you? Check out my DIY friendly website for solar system packages and product recommendations, and so much more! www.mobile-solarpower.com
    Join our DIY solar community! #1 largest solar forum on the internet for beginners and professionals alike: www.diysolarforum.com
    Check out my best-selling, beginner-friendly 12V off-grid solar book (affiliate link):
    amzn.to/2Aj4dX4
    If DIY is not for you, but you love solar and need an offgrid system, check out Tesla Solar. Low prices and great warranty, and they can take your entire house offgrid with their new Powerwalls: ts.la/william57509
    ~~~~~~~~~~~~~~~~~~~~~~~~~
    My solar equipment recommendations (Constantly updated! Check here first):
    12V/48V Lithium Batteries: www.mobile-solarpower.com/solar-batteries.html
    Solar System Component Directory: www.mobile-solarpower.com/solarcomponents.html
    Plug-N-Play Systems: www.mobile-solarpower.com/full-size-systems.html
    Complete 48V System Kits: www.mobile-solarpower.com/complete-48v-solar-kits.html
    DIY Friendly Air Conditioner/ Heat Pumps: www.mobile-solarpower.com/solar-friendly-air-conditioners.html
    Complete 48V System Blueprint: www.mobile-solarpower.com/48v-complete-system-blueprint.html
    ~~~~~~~~~~~~~~~~~~~~~~~~~~
    My Favorite Online Stores for DIY Solar and Coupon Codes:
    -Current Connected: SOK, Victron and High Quality Components. Best prices and warranty around: currentconnected.com/?ref=wp
    -Signature Solar: Cheap Server Rack Batteries and Large Solar Panels:
    www.signaturesolar.com/?ref=h-cvbzfahsek
    -Ecoflow Delta Official Site: My favorite plug-n-play solar generator:
    us.ecoflow.com/?aff=7
    -AmpereTime: Cheapest 12V batteries around:
    amperetime.com/products/ampere-time-12v-100ah-lithium-lifepo4-battery?ref=h-cvbzfahsek
    -Rich Solar: Mega site and cheaper prices than renogy! Check them out:
    richsolar.com/?ref=h-cvbzfahsek
    -Shop Solar Kits: Huge site with every solar kit you can imagine! Check it out:
    shopsolarkits.com/?ref=will-p
    -Battery Hookup: Cheap cell deals
    bit.ly/2mIxSqt
    10% off code: diysolar
    -Watts 24/7: Best deals on all-in-one solar power systems, with customer support and distribution here in the USA:
    watts247.com/?wpam_id=3
    ~~~~~~~~~~~~~~~~~~~~~~~~~~~
    Contact Information:
    I am NOT available for personal solar system consult! If you wish to contact me, this is my direct email: williamprowsediysolar@gmail.com
    Join the forum at diysolarforum.com/ if you wish to hang out with myself and others and talk about solar
    FTC Disclosure Statement and Disclaimers:
    Every video includes some form of paid promotion or sponsorship. Some links on this youtube channel may be affiliate links. We may get paid if you buy something or take an action after clicking one of these. My videos are for educational purposes only. Information is subject to change/update at any time. Electricity is DANGEROUS and can kill. Be smart and use common sense :)
    DIY Solar Power with Will Prowse is a participant in the Amazon Services LLC Associates Program,
    An affiliate advertising program designed to provide a means for sites to earn advertising fees by advertising and linking to Amazon.com or take an action after clicking one of these.

    • @LithiumSolar
      @LithiumSolar 2 роки тому +1

      The problem with this is if the inverter is being used off-grid only (no AC input of any kind connected), you still cannot connect this to a standard home transfer switch. For example, in my Reliance transfer switch, the neutral is not switched (as it should not be) thus the neutral and ground both pass through the transfer switch to the main home panel - where they are bonded together and cannot be undone. In this case, the ground between inverter and transfer switch is now carrying current (very bad). I still don't think there should be a bond inside the inverter. Am I missing something here?

    • @WillProwse
      @WillProwse  2 роки тому +1

      @@LithiumSolar yeah this is the confusion I have as well. When used with a bonded panel. Dexter mentioned you want the bond as close to the source as possible. And you have two inverter outputs in series. So I don't think there is a right way to do this really. No bond might be better actually. But we are supposed to bond at the source. But the source is two separate circuits in series. I don't think there is an actual recommended configuration for that situation. I would imagine no bond would be better, then ground at the panel.
      What they should have done is had a ground netural relay that you could program. Would fix this issue for all these all in ones.

    • @olemissjim
      @olemissjim 2 роки тому

      Have you tried the Tesla mobile connector and the NEMA 6-50 or 6-30 adapter? That’s what I use because it eliminates the entire ground Vs neutral altogether, and is less expensive to wire up
      6-50 and 6-30 are popular with welding setups

    • @matthewalberhasky7114
      @matthewalberhasky7114 2 роки тому

      Will, the non current carrying metal parts of the system should be bonded together with a bonding jumper per article 250.90 of NEC. This is to ensure none of the system enclosures, raceways, conduits, boxes, or panels can have a potential difference.

    • @WillProwse
      @WillProwse  2 роки тому +1

      @@olemissjim yes, using 6-50

  • @teotwawki_je
    @teotwawki_je 2 роки тому +11

    I had in interesting time getting it 'right' on a UK barge. Although our 240V single-phase is simpler, the occasional use of shoreline utility power needed extra thought. We ended up not bonding N to E within the boat as that often caused the onshore utility outlet, or the on-board RCD before the inverter input to trip. All Earths are connected onboard & with the DC -ve of both 12V & 48V systems. But while diagnosing the tripping we ended up with a 3-way switch to govern how the on-board earth connects with the shore-line earth. In one position it is a direct connection, in the other position it goes via a galvanic isolator. The mid-position provides isolation (just for testing, with the all-in-one configured to not use bypass). It's all stable & reliable now.

  • @Bruce-ub8dv
    @Bruce-ub8dv 2 роки тому +2

    Great video. I've been thinking on this for installation of two units to provide 50AMP power for my RV. The grounding has been my boggle, but I think in an RV if I were to bring the AC Input from the automatic transfer switch that the T-switch should handle the ground-neutral bonding for me as it does between the generator and shore power now. Still working on this (on and off as I have time), the total lack of documentation from the All-In-One manufacturers really makes it a pain to figure out how to execute safely.

  • @centerrightproudamerican5727
    @centerrightproudamerican5727 2 роки тому +15

    As far as I know *ALL* inverters connect the AC-In ground, AC-Out ground and the Inverter case together.
    For grounding, pick one spot for the central ground point and connect all the inverters to that one spot and only to that one spot.
    * If the central grounding spot is the grid-connected breaker box before the inverters, then connect all the AC-In grounds to the box and do NOT connect the AC output grounds to anything. Then run another ground from the grid connected box over to the critical loads box.
    * If there is no AC input, the 'critical load box' is the central grounding point. In this case, connect all of the AC-out Grounds to the critical load box and do not connect the AC-in grounds.

    • @neliosamch3195
      @neliosamch3195 2 роки тому

      This is correct for 110-120v ac systems but for 220-240v the old system didn't need the neutral but the new systems need L1 L2 N and ground or the Tesla will not work.

  • @danielt4730
    @danielt4730 2 роки тому +11

    Here is a fun advanced idea to make a video about: with the days getting long, how can you make a "dump load" that will turn on a device to use excess solar when the batteries are fully charged.

    • @jamiebrock7157
      @jamiebrock7157 2 роки тому +1

      Yeah I was wanting to see a video on that too

    • @catalinalupak
      @catalinalupak 2 роки тому +2

      There are inverters doing this. Try Sol-ark or Deye, the Gen connectors act as a smart load and you can configure the Gen output to be a dump load (water heater)

    • @80sDweeb
      @80sDweeb 2 роки тому +3

      I would think Will Prowse would design a way for excess energy to mine bitcoin, not just heat water.

    • @spicethewolf8694
      @spicethewolf8694 2 роки тому

      I wonder if you could use a voltage-sensitive relay and a contactor for that function, when the voltage of the battery gets high enough itd close the contactor and plug in that device. ON multi inverter arrays i also wonder if one of the dry contacts could be programmed separately from the rest to have the same function? Food for thought ^,.,^

  • @MultiOutdoorman
    @MultiOutdoorman 2 роки тому +1

    Hi Will.
    Yep. Definitely bond / ground earth and neutral only at the source so that your RCD'S (UK) / GFCI's will trip if a fault condition occurs. An earth loop impedance test procedure (ZE) proves this.
    One pole of a suitable N.O contactor relay can be used to achieve this bonding function ...when power becomes "lost" from the grid making the inverters " off grid".
    This way the original grid bond will be established once grid power is resumed and the contactor re-opens breaking the "off grid" neutral to earth connection.
    Its losing the neutral when the supply is disconnected that makes this so important !
    My quest is to fully understand the grounding arrangements and benefits gained from earthing my 48 volt Pylontech battery ?
    I have my solar (DC array, framing and metalic enclosures) grounded via a thick cable going into an earth electrode rod in the back garden ( not linked at all to the grid / AC earthing system.
    Should i bond the battery and metallic enclosures to the output side of the negative fuse terminal ?
    Assuming zero volts exists there and it just provides a low-resistance path for the DC battery current to pop a fuse under a short-circuit fault scenario ?

  • @lunatik9696
    @lunatik9696 2 роки тому +7

    Personally, only the generator (floating ground) will connect to AC input,
    but usually genny only drives a floating charger connected directly to the battery, multiple chargers if the load requires.
    Ground is a local reference and 2 different grounds may not be the same reference aka ground loop.
    The power company may have 100 to 150 KV on the pole and taps on a transformer for a specific circuit.
    A transformer may supply multiple circuits.
    A transformer with 220 secondary and dual (180 phase shift) 110 secondary circuits with a center tap, the new (CT) ground reference is different from the input ground. One would not want to tie the input and output grounds together.
    The power company knows you are going to ground your breaker box and designs their system accordingly.
    When using solar/ grid tie configuration, the equipment should handle any grounding issues.
    If one was completely off grid, from a purely safety perspective it would be prudent to ground the box to a copper rod,
    however, once done, the solar panel may increase the likelihood of becoming a lightning rod if not otherwise present.
    Letting ground float might offer some protection.

  • @markseamans4682
    @markseamans4682 2 роки тому +2

    I plan to use my home's slab as an ufer ground. I'll have multiple access points to bond any/all panels, etc to this single bond. I also plan to install several GEM trenches (ground enhancement material) to further diversify my grounding. So, in short, my grounding would not be a loop, but all bonded to the same grounding source. Ground-Neutral bonding should be as close to the "utility" as possible. So either at the outside main panel. I would think if the inverters feed directly to this panel, their own neutral-ground bonding would not be an issue. Oh, I also get to add in a 75 ft antenna tower into my fun....

  • @4philipp
    @4philipp 2 роки тому +2

    Seems a lot easier to just keep it as a off grid isolated system. Even for 240V loads like charging the Tesla I would use dedicated 240V equipment. And lastly, I would use several independent systems. One for ground floor, one for upstairs, one for basement and another for the garage/workshop. Might be more expensive but if one system fails, the others still work. Instant resilience to power loss.

  • @sebastiant5695
    @sebastiant5695 2 роки тому +3

    Nothing should flow through ground during normal operations. I think the electric code specifies there should be only a single Ground Neutral Bond in a system. As far as I understand you can have multiple grounds in a system but only one Bond between ground and neutral. I mean when you mount a breaker box against a metal building part - it's already grounded. I think what you are concerned about is a "neutral loop" Which can happen when you got two grounded and bonded panels.

  • @KnowledgeCravings
    @KnowledgeCravings Рік тому +1

    Ground wire is a backup track from any device to the source in case a live wire is shorted to the panel of the device. And there should be only one return path to the source and at the source ground wire is bonded to the neutral( either it is a battery based source or a transformer). In case of battery, it is a neutral bond inside it. In case of utility it is at the main panel. In your case when inverter is transferring utility power to house, it should connect ground of utility ( coming from main distribution panel of house) side to its loads. When in battery mode, it should disconnect that ground and instead source a ground from neutral bond. But I don’t know if your inverter has this switching happening inside. My two cents…

  • @nathans3022
    @nathans3022 2 роки тому

    100% spot on. Would you like to see what Sigineer says on how to hook it up like you have your setup done? Guess I could email/message you the link. Only ground once. Only bond the neutral and ground ONCE.

  • @justvisiten
    @justvisiten 2 роки тому +2

    You have such great skills (I am in awe of your verbal skills) and insight in explaining what you are talking about but as an old retired master electrician, I just cannot understand all of this without schematics and symbols. And words seem to often fall short on tecnical problems. When I went into programing industrial automation, honestly words just could not much help. However, fortunately my limitations are not universal, and keep up the great work. And ground faults seem to be such a misunderstood problem and for good reasons. Let us all try to help each other stay safe! Says the old arc flash safety trainer.

  • @diySolarPowerFunWithRay
    @diySolarPowerFunWithRay Рік тому +1

    When my growatt 3000 LVM-48P is running just off the battery, there also is a GN bond created... However the bond is CRAP. I see continuity, but there is a TON of resistance there. so much that my furnace won't run unless i re-create my own GN bond.

  • @martinmiller7623
    @martinmiller7623 2 роки тому +1

    Have your checked the code book. Grounding is for lightning protection also.

  • @robinthurston3382
    @robinthurston3382 Рік тому +1

    I have an all in one inverter using the reliance 6 circuit transfer switch. The transfer switch is using my utility ground so therefore no need for a ground for the inverter. My panels have their own ground to limit a static charge and prevent a lightning strike but it stays separate.

  • @wadebrewer7212
    @wadebrewer7212 2 роки тому +2

    Never clicked so fast. Thank you will for all you hard work!

  • @hijamesob
    @hijamesob Рік тому

    I knew my bro Will was a Bitcoiner. Just knew it.
    Thanks for the awesome information, man. Building a solar array because of you.

  • @damienxcelcier6591
    @damienxcelcier6591 2 роки тому +12

    You must keep the ground and Neutrals separate in this case. The only connection made between the ground and the neutral conductor is made on the service side at the meter base. Everything beyond that is a bonding conductor bonding the system the the grounded system conductor. All electrical systems only have One grounding conductor. That is generally the #6 CU conductor that is terminated to your grounding electrode. The green, or bare conductor connecting your equipment to “ground” is the bonding conductor. I believe this is just confusion on the proper use of wording. The conductor referred to as a “Neutral” in this case is, by definition, the conductor that caries the unbalanced load in a three wire electrical circuit supplying two different voltage loads (ie: your range in your home is supplied by a 3 wire circuit, supplying 120 volts to your digital timers and clocks while 240 volts is supplied to your elements, the unbalanced load than travels the neutral conductor) - The white conductor often referred to as the “neutral” conductor in a two wire circuit is the “Identified” conductor, which is the grounded circuit conductor, and it is bonded to the grounding conductor at the meter base. You can not create a ground loop in this case, as current will always take the shortest path to ground, never going back on itself or traveling multiple paths. Though the additional bonding would be overkill (creating a “super bonding” type situation) I’m unsure of what hazard you would be creating. This is not armoured single conductor cable, so sheath currents would not apply.
    PS: Love your videos, the tear downs, and explanations on batteries and renewable energy networks is outstanding.

    • @WillProwse
      @WillProwse  2 роки тому +4

      Yes I agree

    • @olemissjim
      @olemissjim 2 роки тому +5

      “You got to keep ‘em separated “ blasts in the background.

    • @malcolmkegel3905
      @malcolmkegel3905 7 місяців тому

      So in the case of having inverters as the source in an off grid system the ground rod to the main panel should be the only ground? And the inverters create the neutral to ground bond? All other grounds and neutrals should remain separate?

    • @Gary-ee3kq
      @Gary-ee3kq 5 днів тому

      ​@malcolmkegel3905 ground neutral bond in the service panel is only used in RARE instances when you are in AC bypass mode. If you have enough panels to power your load you don't need to worry about this.

  • @pathdoc
    @pathdoc 2 роки тому +1

    You should be OK with an additional ground rod if you bond it to your utility ground, preventing a ground loop and a voltage potential. Use at least #6 solid wire.

  • @spicethewolf8694
    @spicethewolf8694 2 роки тому +1

    while I don't have one of these units in front of me (yet) I would assume they are using some form of the contactor to switch between the Grid-tied and islanded states. This contactor would be wired to have the Grid side simply pass straight through the inverter with the charging circuit tapped onto its output. If this is the case, you DONT need any special wiring as the inverter does all the thinking for you I believe. You would simply use the neutral and ground bus in the subpanel like you would normally a standard 240v outlet (it shouldn't need a ground connection to the case as the ground bus is already electrically connected but check for yourself always). This lets the inverters Operate like a simple off-grid DEVICE (NEC CODE TERM), using the panel neutral when it is grid-tied and creating its own bonded neutral when islanded. All inverter chargers I've seen inside of including growatt and victron operate this way as do some RV generator transfer switches its effectively the same as plugging in a cord to an outlet and in fact you can do just that. All the same connections are needed in the same format for each inverter. The inverters in Islanded mode will create a Unified neutral at the point of generation (they act like one big inverter) that effectively BECOMES the main panel with the bond.
    One last thing. ALL of the inverters should be fully grounded to the panel or sub-panel, but there should only ever be one ground rod from the main panel as you've pointed out or a ground loop WILL occur. even when islanded the inverters will "borrow" that ground for operation although it is not necessary for function(think RV or mobile applications) same reason many generators have an extra ground lug on them so you can Borrow the house ground for extra safety but will run just fine without them. In the islanded state however the neutral and hot are electrically disconnected from the inverter and not performing any functions outside of isolated sensors and thus no strange loops or secondary bonds are occurring.
    When in doubt grab your meter and test it out. should operate just as if you pulled a plug from the wall when islanded except a ground connection was maintained but the inverters have created their own bond. If feeding a sub panel with the inverters you would not need that panel to be bonded in islanded OR grid-tie use after the inverters
    Just two cents from a nerdy solar lover and Electrician apprentice ^,.,^

  • @ShaleAudio
    @ShaleAudio 2 роки тому

    It really becomes risk management in worst case scenario, and thank you for specifying this is not for beginners

  • @lowprofileish
    @lowprofileish 2 роки тому +3

    Will i am running the same set up as you how ever, My main panel is just a out door 125 amp Ground is separated in the main panel. From there everything runs to the out buildings from the solar shed. House, well pump, RV and outdoor pedestal. I am 100% off grid I do have a generator for back up and it has a floating ground connected to one of my inverters. I made all my runs to other buildings on my property minus the ground. so I just ran Hot and Neutral to each sub panel and added a earthing rod as each. I have had no problems doing this and everything is working Awesome.

    • @lowprofileish
      @lowprofileish 2 роки тому +2

      I treat my 6548 Inverters as the main panel and all other panels as sub panels with separated grounds and Neutrals.

  • @kimwarfield1587
    @kimwarfield1587 2 роки тому

    Hey Will, can’t wait to see your review of the new Bluetti AC500 and B301 battery pack.

  • @Just_An_Idea_For_Consideration
    @Just_An_Idea_For_Consideration 2 роки тому +4

    I am still confused, but appreciate the thought process and analysis. Please post additional info when you determine the safe solution.

  • @Just_An_Idea_For_Consideration
    @Just_An_Idea_For_Consideration 2 роки тому

    excerpt
    If power for IT equipment is served from a separately derived source independent of the building ground system, noise might be generated on the system. This is a form of common mode noise, in which the power-source ground is referenced to a different point from the equipment ground. These stray currents-in other words, noise-can find their way onto grounded equipment, thus energizing the equipment.

  • @MrThat0nekid
    @MrThat0nekid 2 роки тому +2

    I’ve had issues with all-in-one inverters like this in the past. Mostly sol-ark, and I found that if i don’t bond the neutral to the ground in the AC output load center, I get fault codes, and I even got shocked from the ground out of the inverter. But once I tie the neutral to ground in the panel, problem solved. Very strange as I was under the assumption that they were bonded within the inverters themselves.

  • @MegaScott
    @MegaScott 2 роки тому +1

    I think people forget that these Hybrid solar inverters were originally designed to be added to an existing AC mains consumer panel which has its own Neutral grounding scheme from the loads back to the panel.. its supposed to have utility power line installed directly into the AC input, then the AC output fitted to the existing distribution panel. The Inverter acts like a whole house UPS, switching to to to the mains when the solar power or the battery power becomes insufficient and vice versa.

  • @fjdkfjdk
    @fjdkfjdk 2 роки тому +6

    Thanks for posting this, as it will get a lot of attention. I've been trying to get a definitive answer on this topic for a while.

  • @altuber99_athlete
    @altuber99_athlete Рік тому

    3:10 You can indeed connect a ground rod to the AC output of the inverters. But it must be done to the ground terminal, not to the neutral terminal (to avoid ground loops and objectionable current).
    Similarly, in telecommunication systems, the NEC requires you to add a new ground rod to the grounding/bonding system (but not the neutral) of the telecom system if the distance between the telecom grounding system and the power grounding system is greater than 6 meters.

  • @terajarvie4368
    @terajarvie4368 2 роки тому +3

    Awesome happy you are bringing this up because I was looking into getting one of these.

  • @defjamsgreen
    @defjamsgreen 2 роки тому +4

    I don’t know but it seems that the High freq split phase inverters really don’t have a neutral ground like a low freq split phase inverter transformer .The same for a pole pig transformer connected to your house . Could there be a ground/ neutral difference among the two since the high freq split phase inverter is all electronic and the low freq split phase inverter has just a transformer ? Might can do a test differential video among the two outputs with neutral /ground to find the best way to connect them to alleviate a common ground loop problem . May the solar be with you Will Prowse or any prepper interested in this matter .

  • @isovideo7497
    @isovideo7497 Рік тому

    I have two LV6548 units connected to the grid for bypass mode, so the neutral and ground are bonded at the grid master breaker. It is important to not bond the neutrals and grounds anywhere else, including any subpanels, thereby avoiding current sharing between the neutral path and ground path. Current sharing is bad - high currents may result in voltages appearing on the ground, which leads to the possibility of electric shock from equipment cases. No current should flow through ground during normal operation. The LV6548 units disable ground-neutral bonding when in bypass mode - so far so good. However, in battery mode, each unit will connect its output neutral to ground using a relay. This works if there is only one LV6548 in your system, but for multiple units, the extra connections need to be disabled. If you remove the case of an LV6548, you will see a small inverted circuit board just left and below the center. If you peer vertically down along the top edge of that board, you will see a screw head on the circuit board below. Remove that screw to disable any bonding.

  • @rickhealey3941
    @rickhealey3941 2 роки тому +1

    Any chance of diagramming what you're talking about? It's over my head but I'm very interested in what you're saying.

  • @TisTheDestiny
    @TisTheDestiny 2 роки тому +6

    For my dual victron split phase setup, the grounds are daisy-chained to avoid ground loops. The victrons have a ground-neutral relay that closes when shore is not connected; I made sure that my incoming two neutrals to AC-IN and the outgoing neutrals from AC-OUT are the SAME LENGTH so the resistance was as close as possible. The 14v you saw may be due to mismatched neutral wire lengths. Agreed -- if connected to grid, don't add another earth ground. And agreed -- don't add another ground-neutral bond in your panel. It appears, like the victron setup, you'll always have a ground-neutral bond, regardless of whether you're connected to the grid. You technically had two bonds (albeit short distance so highly unlikely to cause an issue). you may also have small ground loops if you're not daisy-chaining your grounds (Inverter 1 -> Inverter 2 -> panel; also grid -> inverter 1 -> inverter 2). Daisy chains may be problematic from a code perspective; you don't want a breakable ground (so the daisy chain must remain intact if you disconnect the middle device from ground - a la pigtail). I am not an electrician; I went through this same exercise with Filterguy on the forums when designing my RV system.
    BTW I didn't think it was safe or accurate to check for continuity on live wires (voltage potential between the wires)? Maybe today's meters can handle that? Dunno...

    • @TisTheDestiny
      @TisTheDestiny 2 роки тому +1

      I guess what's not clear from your testing is whether the G-N bond actually comes from the grid when powered by the grid. I WOULD expect ground to be connected all the way through no matter what, just as you showed. From your description of the expected behavior, it *sounds* like there's a G-N bonding relay?

    • @spicethewolf8694
      @spicethewolf8694 2 роки тому

      Yes a CAT III meter will happily handle the voltage rms produced by our solar systems so no worries on prodding away at terminals just dont accidently put it into the amp testing modes as most are limited to about 5A I believe? looking at my fluke next to me thats what this model says. Itll act as a dead series short in that mode and we know what happens then

  • @ScottMartinez
    @ScottMartinez 2 роки тому +1

    I had bonded with a jumper my neutral and ground when running a single LV2424 pip since my ground would float after the sun went down and the charge controller relay would kick off. I was grounded to the AC input, but it didn't seem to matter. -The inverter output would float the ground after sunset. I have since added a 2nd LV2424 to make a split phase system and put in a panel where the ground and the neutral are not bonded. This was in theory that the both the AC inputs had neutral/ground bonding in the main panel. The floating issue after dark has since gone away. I have a Reliance transfer switch for critical loads that also ties into the main panel ground/neutral bar. So at this point, my ground for the whole system is bonding to the main panel at the AC input. I have both PIPS connected to main panel on their own leg from the utility. It seems good, but I'll check to see if I am getting leakage on the grounds during the day and at night to see if something is screwed up.

  • @errcoche
    @errcoche 2 роки тому +3

    All a little bit over my head but it occurs to me that what Will is doing here is a pretty standard installation, pairing two of these units in an off-grid configuration and that any manual should offer a "reference design" for the most common deployments. There really shouldn't be too much debate about the standard way to do this and discussions should be limited to when you decide to get a little funky with your design. Manufacturer's need to do a better job with documenting reference designs and maybe pay some people who know what they are doing to develop these designs and document them. I think an extra $50 on the price of a unit would be well worth the reduction in research and headaches while trying to figure this stuff out.

  • @b25mitchel
    @b25mitchel 2 роки тому

    Hi Will, at about 2:30 you stretch both arms to make contacts. Please consider a spring loaded "alligator clamp" for the test wire so your arms don't provide a possible circuit.

    • @WillProwse
      @WillProwse  2 роки тому +1

      I actually have a lot of those but they were on the other side of the shop

  • @dougyoes
    @dougyoes 2 місяці тому

    Great video, Will. I agree with your assessment. In my case, I've created a hand-truck solar generator with EG6000XP (Luxpower) and EG LL-S battery. But my biggest concern has been this neutral-ground topic. Most of the time I will back-feed my home electrical panel through a 50A interlocked breaker. In that scenario I am wanting to use the neutral-gnd bond in the 200A panel and DISABLE the n-PE (setting 26) in my inverter. That will ensure I am relying on the house panel's n-PE connection. BUT...when I want to use the hand-truck solar generator in stand-alone mode (not connected to my house panel), I then need to ENABLE the n-PE (setting 26) in my inverter. But there are scenarios where this can be muddled. What if I forget to change the setting? What if I still have setting 26 ENABLED and I plug the solar generator into my 50A grid (to charge the battery without PV, or to just use it to provide bypass)? If setting 26 is still ENABLED, then I've created a ground loop. Another scenario is where I still have the output of the solar generator connected to my "Generator Input" wall receptacle and I haven't flipped the interlock over. In other words, I'm not backfeeding my 200A panel. I'm using it in stand-alone mode - but kept the output cord plugged in. This is a problem because only the two hots are disconnected at the 50A breaker. BUT, the neutral and ground wires ARE connected to the 200A panel because I left it plugged in. If I turn on my solar generator and still have setting 26 ENABLED, then I have a ground loop. Some may say... "Well, how can that be? You can't use your solar generator anyway, because the output isn't being used. It's still plugged into the Generator receptacle." EXCEPT, that I have a 20A power strip on the solar generator. If I use any of those plugs, the n-PE connections are both in my inverter AND in the 200A panel. It is paramount that I remember to change the n-PE setting, depending on the scenario. One more thing. Just this afternoon I had a journeyman electrician tell me I would need to drive two 8 ft copper ground rods, spaced 6 ft apart, each time I use my solar generator in stand-alone mode. I thought, "Man, you have got to be kidding. Have another beer." In stand-alone mode I'll want to establish a n-PE connection in my inverter by ENABLING setting 26. But I do not want a ground rod. I have discussed this with Signature Solar and they agree with my approach. What say you?

  • @VincentsfamilyCali
    @VincentsfamilyCali 2 роки тому

    The technicality is way over my head, but i think I got the main point from this vid...For my off grid 120V set up with just one AIO inverter, DONOT bond N-G in the breaker panel because the AIO inverter bond N-G internally when using power from battery, and if i need to use gas generator to power the AIO to run bypass mode and charge battery, the generator need to be bonded N-G. Basically all the bonding need to be done at the AC input of the AIO inverter, not the OUTPUT. Thanks Will and Filterguy

  • @SylwerDragon
    @SylwerDragon 2 роки тому +1

    As you said .. Ground should have only on one place never in two places because of ground loop issue. That is why usually on AC input is ground. You can connect chasis of each inverter into ground of your input system. ..For those who use that..ofc on some system where there is no ground it is the best thing to make ground..but ofc only one point..i had inverters that were from plastics so they didn't have 3rd wire so yeah that is also option as they had floating voltage..to be honest i'm using that kind of inverter for outside stuff ..just in case there is contact with water..it is abit safer

  • @anothercasualobserver8764
    @anothercasualobserver8764 2 роки тому +5

    @Will, I think I've been saying the same thing maybe in an awkward fashion. In the example you provide here the panel should have a floating neutral and the ground should be bonded to the case. It is effectively a "subpanel". Equipment bonding to ground and neutral ground are 2 different animals. Supplemental equipment grounding is okay and even encouraged but you only ground the neutral (current carrying conductor) at the point of origination. Subpanels ALWAYS float the neutral. That describes U.S. grid systems. I would expect the same set of requirements essentially to apply to an off-grid or separately derived system. Is that correct? Are we saying the same thing?

    • @readoryx373
      @readoryx373 8 місяців тому

      Thank you. I will remove the bond wire in my sub panel and float the neutral and allow my off grid ecoworthy 5k to manage the bond internally. I was alarmed and reacted when I saw a 33vAC potential between N and G at the panel.

  • @neliosamch3195
    @neliosamch3195 2 роки тому

    The Schneider Conext MPPT 100/600 has two ground, one for positive and one for the negative but only one can be active. my system is negative grounded so the fuse can go only in the negative fuse holder.
    The instructions are clear for mobile application ground and neutral have to be bonded and gound strap is required for vehicles but on grid applications grounds from house distribution box and for auxiliary inverters have to be bonded.

  • @n3qdz
    @n3qdz 2 роки тому +3

    My only questions is with the ground either looped or in one panel how would this effect GFCI circuits? The other issue is on a totally off grid system, if these is a generator backup is that considered grid power? Or how would you connect the generator? Do you first ground the generator or just run ground to the first inverter system? You bring up great issues that get you thinking.

    • @davidhyman4541
      @davidhyman4541 2 роки тому +2

      A GFCI (ground fault circuit interrupt) looks for the difference of current on the circuit conductors. For GFCI to work properly you cannot bond ground and neutral. On a Generator they have ground lug so you can connect to a ground point and provide the unit chassis/earth ground, and without it would be a floating ground, all chassis would have the same potential, but no earth connection.
      If you have your Inverter grounded with an earth ground via a sub-panel, the ground wire in your generator cable would provide a chassis ground to the generator.

  • @Gaijin101
    @Gaijin101 2 роки тому +1

    diagrams, even hand drawn, would help tremendously in explaining. :)

  • @paulmccoy2908
    @paulmccoy2908 2 роки тому +2

    You should use ONLY the utility ground-neutral bond (in the meter or main panel) in any instance where the neutral conductor of your utilization system is connected to the neutral of the utility system.
    Only if you disconnect the utility neutral input from the output of your inverter (either automatically, manually, or by design) should you bond elsewhere, such as inside of or after your inverter.
    You can have as many grounding points (ground rods, metal equipment sitting on concrete, conduit attached to steel framing) as you want, so long as there is ONLY ONE point where your ground system is connected to your neutral conductor.

    • @paulmccoy2908
      @paulmccoy2908 2 роки тому +1

      You could even have a separate ground rod for each inverter, panel, run of conduit, outlet, etc. as long as you attach it to ONLY the earth ground and not the neutral conductor.
      The take away is ONLY ONE GROUND-NEUTRAL BOND PER PROPERTY at a time. Everything else is details.

    • @JohnDoe-pv2iu
      @JohnDoe-pv2iu Рік тому

      @@paulmccoy2908 And tie All of the Earth Grounds with #6 copper!
      Ya'll Take Care, John

  • @_loki
    @_loki 2 роки тому

    I think the best solution for bonding multiple inverters is actually simple -- a dedicated non-current carrying wire from the neutral bar within the inverted panel back to each inverter's bonding relay. Without current there are no voltage differences between each unit, and thus no ground loops. It's a controlled parallel path situation, where there is only ever current when you want it to be there -- namely a ground fault. I don't like only having one unit bonding as the inverter may fail, but the rest of the system still operating without issue and without noticing (think parallel 120v -- not split phase).
    The neat part here is that it's basically what's already being produced and it would ship from factory with a N > Nb jumper installed. Then if you are connecting many in parallel, you can remove with 5th wire. Additionally, if you are connecting to an existing bonded panel say for backup generator purposes, you can remove entirely (similar to software disable).

  • @AdrianPanciu
    @AdrianPanciu 2 роки тому

    I want to use a separate grounding at more than 10m distance, under 4ohms, with a permanent link between N and PE on AC out. For home circuits I will use the home grounding, completely separated from it.

  • @victorshane4134
    @victorshane4134 2 роки тому

    I dont really know what is your elecrical system looks like, but our in Europe looks like this : 230V (50Hz) supply consists of 3 wires. 1-hot, 1-neutral, and 1-safety ground. 230V (50Hz) is obtained between the hot and neutral lead. Double-pole main circuit breaker protects both the hot and the neutral leads. Branch circuit breakers are single-pole, switching the hot lead. Has hot bus connected to the line side of the branch breakers. Has separate buses for neutral and safety ground. Standard European practice and ABYC requirements include ground-fault protection for the entire AC system as well as critical branch circuit GFCI protection. I think, no matter what we do, and how we do our configurations : There must be a LINE IN from the GRID connected to the Charge controllers (and never use the grid power but the Neutral and Grounding) or a dedicated grounding wire connected to the inverter(s) and other devices that requires grounding wire. And never ground twice! ONE SINGLE COPPER ROD IS MORE THAN ENOUGH!

  • @ForbiddTV
    @ForbiddTV 2 роки тому

    Part of the advertising for the LV6548 says "custom parameters can be set according to any battery between 40 and 62V". Does that mean I could use a higher voltage battery bank, say adding a couple cells as long as I keep the high voltage cutoff at 62V or less? I am replacing a 120VDC 1640AH telephone battery bank and am bummed that the highest voltage solar battery banks have got to is 48VDC.

  • @sattiodibo2598
    @sattiodibo2598 5 місяців тому

    Nice information. But what about if the grid fails. Maybe something happened and there is no power from the grid. How will the system be bonded to ground. Because now we just loose our grid. Where our ac input. Ground and neutral is bonded.

  • @Jimmy___
    @Jimmy___ Рік тому +2

    Thanks for doing these videos Will. Please can you do a video on using super capacitors or capacitor banks to increase the surge capability of an inverter system? For example, running loads with high inrush/startup current. I believe there are people doing this currently and it "works". Or if you think it's a terrible idea, let us know. Also, my 2.3kW Goodwe EM inverter says not to run an air conditioner on it, is that because of the surges, or it being an inductive load? If it's just the surge issue then I'd be tempted to use capacitors on the circuit. If it's going to kill my inverter and/or AC even with capacitors, then obviously I would avoid that.

  • @1noryb
    @1noryb 2 роки тому +1

    Hmmm. I am not an electrician. Having said that it has also been 20+ years since messing with electrical circuits. I begin thinking 1:1 isolation transformers would be the ticket to interrupt any DC bias. However if the inverters are outputting pulsed DC and not AC, I have no clue.where to go. just 2 cents that is probably inapplicable.

  • @raullasvegas
    @raullasvegas 2 роки тому

    You have to bond the panel. If one of the LV6548 isn't connected, there is more neutral current than what the system can handle. You would have to wire each invertor with the maximum current that the system can handle. Each invertor isn't designed to handle all of that possible neutral current. It has to be done at the load distribution panel.

  • @timgerk3262
    @timgerk3262 2 роки тому +1

    Looked for someone to mention this...couldn't find.
    The reason for bonding neutral to ground is for a low impedance path for fault current to return to "source" This completes a circuit to enable over-current protection devices to work promptly when a "ground fault" (a path from hot to case, for example, occurs in some load-side device.) In inverting mode, I'm convinced the inverter is a separately derived system & requires the AC neutral output to be bonded to equipment ground for the purpose I described. The inverter is the "source" where ground-fault current must return. In bypass mode, I assume the AC inputs and outputs are continuous & the AC output should not be bondedin addition to the prescribed bonding at the electrical service main shutoff, as Will explains. Only if the AC input and output neutral are always internally continuous, could we elect to bond once, but on either side. I use a random manufacturer 240VAC split phase inverter/charger with no connection to AC input neutral. I have to believe that bypass mode is *not* simply pass-through mode, & so I must bond neutral output and ground to get a ground-fault-return-to-source path for either 120V leg.
    The statement about AC charging was unclear: load devices are always connected to AC mains in parallel, and connecting in parallel to a DC bus is not a challenge, up to the charging current limit of battery.

  • @andrewt9204
    @andrewt9204 2 роки тому +1

    Yep, this is causing issues for me. I'm using a single LV2424 to power some critical circuits as a backup/free solar.
    The AC output of the LV2424 is going to a sub panel which I have combo AFCI/GFI breakers in, however these are occasionally tripping, along with the 30A GFI breaker in my Main panel that serves the LV2424.
    Like you, I have measured 1 volt or less between various points of neutral and ground in my system. I am thinking the bonded neutral in the LV2424 is causing a very small voltage leak to ground that is tripping both input and output GFI breakers.
    But for safety concerns I want the LV2424 input to be GFI protected in case something catastrophically fails in the inverter to where the casing could be energized.
    Not sure where to go from here. For now I replaced the GFI breakers with standard thermo-magnetic ones. Which is not ideal and I want to find a solution ASAP but it keeps my circuits active for now...
    I should note that I have the LV2424 output circuits going into transfer relays so if the inverter fails, the transfer relays fail closed and the critical circuits still have power from the Mains panel since the LV2424 AC relay is a fail-open type.

  • @lifewithlonsi
    @lifewithlonsi 2 роки тому

    I found this to be true with my Growatt. I contacted them and found that removing a couple of grounding screws on the main PCB it would break the bond - all good now.

  • @johncampbell2311
    @johncampbell2311 2 роки тому

    You need a bonding wire and all metal objects that you can touch with your hand needs to go through this bonding wire to a ground. So I would string a bonding wire from each unit to your panel to ground it all assuming your panels go through your AC supplier. As for rounding loops you're supposed to have two grounds on the house that's a loop as well they tell you I believe by code 8 to 18 ft apart depending on what locations you at work parts of the country. That's why a lot of them use your copper pipes coming into your house as the second Bond.

  • @danpeaslee6786
    @danpeaslee6786 2 роки тому

    Will, I hope you find out definitively and post an exhaustive video for both off-grid and grid tied.

    • @WillProwse
      @WillProwse  2 роки тому +1

      I contacted MPP and they agree with my solution. Grounds and neutrals separate.

  • @loristyles7786
    @loristyles7786 2 роки тому +1

    Ok so I know that this was advanced users but as someone who wants to set up a dual All-in-one system for off grid only, how do I set up the neutral and ground at the load panel. I got confused by the different scenarios discussed.

  • @alvarojosesanmartinvalenci6243
    @alvarojosesanmartinvalenci6243 2 роки тому

    Grounding the solar panels and supporting alluminum structures (DC side) to the same ground rod for panel and inverters AC side)
    Or 2 separate ground rods for each side. (NEC unifilar ongrid description.)

  • @robertharker
    @robertharker 2 роки тому +8

    In any power distribution system the safety or earth ground and the neutral reference are supposed to be completely separate except at the main panel because they serve two different purposes. The safety ground is to protect against accidental shorts and electrocution. It can also be used as a ground reference with active electronics. On the other hand the neutral is used to balance current differences between the two legs of a single phase high voltage (over 42 volts) power distribution system. The ground and neutral are bonded at the main panel to protect the upstream source on the power pole from shorts in the local downstream power distribution system.
    I don't think the neutral and ground should be connected in the inverter or any downstream breaker box because they serve two different functions. If a vendor is connecting the two then they are connecting them due to a design defect. Ever notice how ground and neutral are never connected inside electrical equipment even though they should technically be the same?
    For an off grid system, ground and neutral should definitely be bonded in the main breaker panel and the panel should be connected to a proper grounding rod. Otherwise in case of a short in a wire or device you are holding, your body is the ground rod.
    As for a neutral between two inverters acting as a single phase system, that is much more complex. How do you balance the load between the two systems. What happens if you have a 240v stove with a neutral wire and then have all the electrical outlets only on one inverter? How do you balance the current on the neutral? Does it even matter?
    If there are high voltage electrical engineers with a better understanding of the subject, please correct any errors I have made. My layman's AC electrical engineering experience is from AC power distros used with large sound and lighting systems. Underwriters Laboratory (UL) probably a good source of information about this.

    • @kiddiescripterkiller
      @kiddiescripterkiller 2 роки тому

      I agree with what you said. As far as balancing, the grid doesn't worry about it, because there is unlimited power.
      When you build a house, good rule of thumb is to put outlets and lights in one room on separate circuits so if you blow an outlet breaker, you still have light in the room.
      If you are using inverters it is your job to balance the load when you are running 240v to save wear and tear on the inverters.
      And the new code is where the earth ground is the earth ground and the neutrals are the neutrals. So earth ground everything to one single point. The old code was grounds and neutrals on same bus bar.
      Will, as far as your 14v there must be an issue with the inverter or you have a ground and neutral touching somewhere on that circuit.

    • @Fei8lo
      @Fei8lo 2 роки тому

      The stove example is not an issue if the neutral conductor is rated for the difference in current. You will want to have a neutral ground bond somewhere in the system to keep the stove from floating relative to the ground. In the case of 2 inverters, both neutrals on the 120 volt legs will be tied but the hots will out of phase. Grounding each inverter in the system with the grid input is generally done for redundancy in case the bond between inverters fails. This is generally not an issue in regards to ground loops given their close proximity and limited charge passing over the ground.
      This will be similar to US split phase systems where the neutral is bonded at the main panel. There may be a common mode difference between properties (each house has a ground neutral bond); this may be a problem if pulling power from multiple main panels from different properties but that is not a real use case. The step down transformers on the grid will service a small area so it provides AC coupling between areas and avoids large DC ground loops even with high common modes differences across a large neighborhood.

  • @AaronBrand
    @AaronBrand 3 місяці тому

    Does “earth ground at the input” mean that the power from the solar panels connect also to a ground rod?

  • @fpmd99
    @fpmd99 10 місяців тому

    Great discussion, Will. Just to clarify when you are using the AC input (and grounding through the AC input), are you still grounding the inverter chassis? Or are you saying we don’t need to ground the inverter chassis? If we should ground inverter chassis, would tying the ground to the ground from AC input suffice? Thanks for all you do!

  • @formulaben
    @formulaben 7 місяців тому

    This would a great subject for a longer in depth video, @WillProwse.

  • @Seven-ff8vr
    @Seven-ff8vr 2 роки тому

    One reason to make a neutral ground bond is for a GFCI interrupting device if you do not have that bond your interrupting device will not work properly.

  • @westcocoagorilla380
    @westcocoagorilla380 2 роки тому +1

    Great topic. Thank you Will Prowse for these very interesting and informative videos.

  • @tomnoyb8301
    @tomnoyb8301 2 роки тому +8

    Earth-ground is to be made at the panel closest to the source (e.g. power-plant), as most local neutral-ground imbalances should be resolved there. Problem is that Solar is also "the" power-source. In grid-tied, the single-point local ground should remain near the main panel with neutral-bond at the main panel. If MPP did it otherwise, they are in error. If Tesla requires otherwise, they are also in error. For off-grid, the single-point local ground could be located near the inverters and neutral-bond in the MPP-box. Source of problem is phase-imbalance, which creates current on neutrals. (more...)
    Neutrals bonded to grounds then improperly carry current, which in-turn creates voltages on the ground(s). This in-turn creates the so-called "ground-loop(s)" so eloquently described by the inimitable Mr. Prowse.

    • @cdoublejj
      @cdoublejj 2 роки тому

      this is most concerning but, i lack enough knowledge to full understand this statment or mr prowse's but, what i can dicern is that official documents and well used companies may not have good documentation or practice and lack functional know how to under stand or identify a ground loop or imbalance

    • @richardoder3459
      @richardoder3459 2 роки тому +1

      I always thought that the first panel that uses a main breaker was where the bond took place if you have sub panels they should not be bonded. I run a off grid system (20Kw with 30Kw of lithium storage) and I keep a grid system for extended periods of inclement weather but they are completely separate. I did have both a bonded (solar breaker panel ) and a non bonded grid sub panel attached to the same metal building which created a constant 13 volts across all the grounds so I moved the bonded panel and solved my problem.

    • @tomnoyb8301
      @tomnoyb8301 2 роки тому

      ​@@richardoder3459 - Yes, sub-panels should not be bonded. Not enough info provided to understand your particular issue, but it's easy to think an issue is solved, only to have it come back to bite (e.g. Mr. Prowse's recent experience)? It's too easy to start bonding neutral's, thinking that a problem's solved because voltmeter says so? ...while ground currents go unmeasured, only to crop-up as a different problem later-on?

  • @mackfisher4487
    @mackfisher4487 2 роки тому +2

    Dam it Will, I was having a nice enjoying unseasonably warm temperatures and you had to bring up equipment bonding conductors. It is pretty straightforward for commercial power, and thankfully the industry has tried to stay on top of the grid tie systems and requirement for professional installations. Off great however needs to have manufacturers supply schematic diagrams and block diagrams to answer these types of questions.

  • @edwardbyrd7667
    @edwardbyrd7667 2 роки тому +2

    I agree with you 100%, and the ground bar in your panel should be connected to the case already. The neutral bar in your panel should be isolated from the case. Generally the neutral bar is closer to the hot bus and is sitting on the same insulator. If you look at Dan’s, and unfortunately I can’t think of his last name, install from on the forums you will see he did the same thing. The ground is continuous from the main panel all the way through the system. The subpanel isolates the two simply because you only want one bonded connection. This holds true whether or not you Pull hots and a neutral out of your main. panel. Dan actually ran into a grounding problem too, but he was running the grounds not only to his inverters but also directly to his subpanel. This allowed current to flow down his ground back to his main
    You’re also right about driving a second ground rod. That is always always a bad idea unless the two systems are 100% separate and separated by a fair amount of ground. And I mean earth not wire.
    I won’t speak to wiring multiple units, I only use one. I will admit to having stared at the multiple unit wiring, and wondering the same thing. I read it as all of the neutrals being connected and a single neutral going into the panel, but that’s essentially the same thing you’re doing by pulling each of the neutrals to the same bar. And OK so I just made a liar out of myself because I did comment on it.
    Great video Will

  • @bdugle1
    @bdugle1 2 роки тому +5

    I’ve worked with industrial power and also my own house. The bottom line is grounds are at earth potential and do not carry current. Neutrals are at ground potential and DO carry current. It seems that the neutral coming into the system from the grid should be tied to ground at the main panel. To keep the output neutral at ground potential, it would seem the grid-derived neutral would need to be tied to the inverter output neutral(s). The ground should be separate but connected to the panel ground as well as the equipment grounds. What am I missing?

    • @diysolaradventures7894
      @diysolaradventures7894 2 роки тому

      Will won't answer me back on none of my questions I have a 48v inverter coming soon but it only has two ac output terminals line & neutral no ground I wanna run it to a sub panel or breaker box I want to use a midpoint transformer to get the 120v I don't know if I should get a ground on neutral sub panel a regular sub panel square d and I don't know what to do about this grounding of the whole system just looking for a little help.

    • @bdugle1
      @bdugle1 2 роки тому +1

      @@diysolaradventures7894 I’m not a master electrician, nor an electrical engineer. You need to consult an expert! However, it sounds like you have a European inverter with single phase 230v (or so) output. This is not suitable for making split-phase, ie 120/240v, power, because you have one neutral and one hot. If it was me, I’d be getting an isolation transformer to convert to split phase, not a “midpoint transformer”.

    • @diysolaradventures7894
      @diysolaradventures7894 2 роки тому

      @@bdugle1 all I know is the midpoint transformer by solar edge has line one and line two and a neutral and the neutral allows to have two 120 volt hot legs on both sides of the panel not 240 but 2 120v ac

    • @bdugle1
      @bdugle1 2 роки тому +1

      @@diysolaradventures7894 The transformer needs to be sized for the full output of the inverter. Then it’s a separate power source and the neutral can be bonded to ground in the main panel fed from the transformer output. The transformer isolates the inverter output which is one hot at 230v and one neutral. That is NOT compatible with split phase 120/240v service where both the hots are at 120v from ground potential. Please consult a licensed electrician to get your installation done correctly and safely!

    • @diysolaradventures7894
      @diysolaradventures7894 2 роки тому

      @@bdugle1 maybe u are misunderstanding my question yes I have a single phase 230 volt inverter I'm not trying to create a 120/240 output the SolarEdge midpoint transformer has a L1 L2 & Neutral that runs into the sub panel the neutral goes to the neutral bar the L1 & L2 goes to the breaker my 230v single phase inverter L1 goes to a breaker and the Neutral basically considered L2 goes to a breaker the SolarEdge ground runs to the sub panel ground then ground the inverter case to the sub panel ground do that sound right I'm not hiring electrician that's the whole point of DIY this configuration should give me two 120 volt legs

  • @ashforkdan
    @ashforkdan 2 роки тому

    How about a white board explanation on what you mean on ground loop.

  • @RichardwWestmark
    @RichardwWestmark Місяць тому

    So the grid transformer, is it ground bounded? And house meter/main bounded? Is that a loop?

  • @NullStaticVoid
    @NullStaticVoid 2 роки тому +4

    Great, so I've seen this explained two completely different ways in the past 30 minutes.
    One saying ground and neutral need to be separate, this saying you need ground and neutral bonded.
    I'm just a DIY guy with a solid understanding of audio electronics and computers. You know, complicated stuff.
    How is there any controversy or wiggle room on something as basic as 3 wire AC? It's been around for decades.

    • @WillProwse
      @WillProwse  2 роки тому +9

      High frequency transformerless off-grid inverters in parallel on each phase has not been around for long. And whether to bond or not depends on your situation. That's entirely up to you. Don't listen to any UA-cam person or manual. Figure out how it works and come up with a conclusion on your own.

  • @georgeknowles5384
    @georgeknowles5384 2 роки тому +1

    Hi Will, Here in the UK, we just have an earth ground (Green), live (RED or Brown) and a neutral (Black or Blue) wires keeping it simple. Why does one need to connect a third to the neutral wire?!! That's putting like a live-sh part (Neutral side of a Supply power) to what you are calling a ground wire, which is supposed to be Just that an earth grounded wire into the earth. Thus any metal surrounding power supplies casings or electrical goods are then save to touch, as they are all connected to ground earth. Which by the sound of things is being turned into the negative side of all power supplies!! Am confused with this!! Makes no sense to me this, a ground wire is either a common negative separate to earth ground is it not? Regards George.

  • @timdowns4629
    @timdowns4629 2 роки тому +2

    What about off grid with generator?

    • @brockashsfrund
      @brockashsfrund 3 місяці тому

      Maybe AC output? I have the same problem

  • @offgridmgtowhomestead2520
    @offgridmgtowhomestead2520 2 роки тому +7

    The bond should always be made as close to the sources as possible. However, I am not a fan of the inverters being bonded themselves. Technically the bonding should be done at one point when paralleling outputs of machines. When they bond them at the inverters themselves, it causes issues of circulating fault current.

  • @ChadDonley-rs3nn
    @ChadDonley-rs3nn Рік тому

    Hi ! I’m as lost as last years Easter egg … I have a RV . Shore power gets turned off automatically when generator is started (factory) ….. I added big batteries, some solar , ac inverter, (my charger) and a mechanical switch to turn off shore-generator and turn on inverter and batteries ….. the ground from inverter plug ties 120 house-120 shore-120 inverter
    On top of all that I want to occasionally use a Honda generator for shore power ?
    I’m thinking that’s a big question (with a few choices) ?
    Any direction would be appreciated

  • @BobHannent
    @BobHannent 2 роки тому

    If there are two inverters next to each other then having the same ground for both isn't an issue because there wouldn't be any resistance between the two inverters bonding to create that Earth loop.

  • @mactech8167
    @mactech8167 2 роки тому

    Just a quick question I have a small inverter 12v little bit off topic but on topic of small inverters 1200watt for camper van (Giandel)it has a ground wire on the back can I just run that to the 135ah LiFePo4 battery negative? or actual ground do I even need to use it on small inverters?
    Actually can you make a ground loop with a small battery’s and small inverters and give us a demo on what not to do that may help some people understand loops better
    Great videos by the way

  • @stevenfrazier8939
    @stevenfrazier8939 Рік тому

    In an off grid only, do we remove the bonding screw in both LV6548 inverters and not ground the panel?

  • @kilaravu8000
    @kilaravu8000 2 роки тому

    Is it possible to connect the negative cable from the solar panels to the eath eathing system?