    @therealmaccoy251 9 місяців тому +2

    Exactly my problem! Straighten out a paper clip and removed the blockage without removing the motor. Furnace fired right up! So glad thankful to have heat again! Thanks Nagen!!!

  • @chadvaughn3559
    @chadvaughn3559 5 років тому +9

    Thank you! Saved a service call. Removed motor, used a paper clip to run in and out of the hole and fixed it!

  • @themexicanstaringfrogofsou5268

    I'm getting a code 2 on my goodman furnace. It says to check venter end switch. Is that the switch located on the inducer motor? Do I need to replace to inducer motor? Mine doesn't seem to have a pressure switch or hose coming out the inducer motor plumbing

  • @Rustytales
    @Rustytales 6 місяців тому

    Thank you very much!
    I checked everything and all the parts were working, but the igniter was not receiving 120 volts. Then I found your video and cleaned this thin tube, everything immediately worked as it should!
    What are the engineers thinking who come up with this junk? It turns out that due to a clogged hole with a diameter of just over a millimeter, a family can freeze in the winter without heating. Junk makers, not engineers. Thank you again for your video!

  • @sabbasdsouza
    @sabbasdsouza 5 років тому +6

    Thank you so much Nagen for sharing this. I had three flashing LED light fault code and did the same thing. Coldest night of the year and the furnace is working again. That was a real helping video.

  • @GregInATX
    @GregInATX 4 роки тому +1

    Thank you So much for this video. My induction motor valve was clogged as well. I cleaned it out with a drywall nail. Thanks again for posting this video. Its was 29 outside today. I was placing a service call tomorrow just thought to give it a try and found this video. I watched about 8 or 9 but none covered this issue.

  • @cjchand
    @cjchand 4 роки тому +1

    Just another note of thanks. I was able to use your info to fix my furnace... without even removing the blower. Thanks again!

  • @captaindelaigle7531
    @captaindelaigle7531 Рік тому

    Thank you! Spent two hours hinder my house and all it ended up being some trash in that nipple! Didn’t have to take it all off just the hose. Very helpful and saved a good bit of money! Thank you!

  • @shawndavis9276
    @shawndavis9276 2 роки тому +2

    Thanks dude! I ended up having to take the hose off from the motor to the switch and cleaning that out I just blew on it really hard and a bunch of dust came out you’re the man

  • @gregorycasey2271
    @gregorycasey2271 3 роки тому +2

    Thanks Nagen , that small tube was full of water and dirt on mine , gave it a quick clean and it fired right up .

  • @dursty3226
    @dursty3226 2 роки тому +2

    Bless you!
    all i had to do was clean out that little tube on the motor.
    thank you for sharing your knowledge and expertise!

  • @nickgoesvestmode
    @nickgoesvestmode 5 років тому +6

    This helped me too! Thank you!! I had an HVAC guy scheduled Monday and now I can cancel! Thanks!!!

  • @bigricyomamie1182
    @bigricyomamie1182 3 роки тому +2

    Your vids saved me as lot of money thank u may god be with u

  • @AdamEisan
    @AdamEisan Рік тому +1

    You rock! Just saved me a ton on a service call. Much appreciated my friend!

  • @kylefromkansas
    @kylefromkansas 3 місяці тому

    Thanks for this video it fixed my problem. I was able to poke it while it was still on the furnace fortunately just took off the hose.

  • @aaronrodden8121
    @aaronrodden8121 Рік тому +3

    Fyi use a small gun cleaning brush attached to a drill....Thoroughly cleans it as the gunk will build back up soon if not done properly. Use a quick drying lube (dry lubricant) to help seal the corrosion as well as prevent more gunk build up due to corrosion.

  • @MrTaherikbal
    @MrTaherikbal 2 роки тому +2

    Thanks, it helped and solved my issue too. You don't need to take off motor to clean clogged nozzle just run hair pin or copper wire thru it. However opening the motor let you see clog and satisfies you.

  • @JavierIncRealty
    @JavierIncRealty 2 роки тому +1

    TOTALLY LEGIT!!!!!! Do it and save yourself the money! Not lighting??? This is probably why! Thanks DUDE!

  • @spirenoir
    @spirenoir Рік тому

    Had replaced the control board, no luck...Blew compressed air into the nipple where the hose connects. Fired up instantly. Thanks for the video.

  • @IIINEMESESII
    @IIINEMESESII 4 роки тому +3

    Thanks man all I had to do was take off the little grey hose and re seat it. It's working now just saved me so much money. My gma keeps paying out the ass to fix this damn furnace. Happens every year. Now I know what they are doing an why it only takes them a few minutes to get it working. Looks like I need a fresh hose mine is split on one end. Doesn't fit right as should I assume. Wayyy cheaper to get myself new hose an replace myself instead of calling the same damn company to rip us off. Thank you

  • @roopananjappa8693
    @roopananjappa8693 5 років тому +14

    Wow! This helped me save SO much money! Glad to see people like this helping out our community!

  • @wmoore0211
    @wmoore0211 2 роки тому +1

    Thank you! This was exactly the problem! Running smooth again!

  • @Tony-tt5mn
    @Tony-tt5mn Рік тому +4

    You're the man! After trying to clear it with compressed air(no luck) I cleared it with a guitar string without taking the motor off. Hope this saves someone some time!

  • @blackpeterose
    @blackpeterose 2 роки тому +1

    Nice job Sir! You are spot on with this repair. 👏 I

  • @mr.k2744
    @mr.k2744 3 роки тому +1

    Awesome man! I had the same exact problem and just fixed it today! Thank You! Tomr is 30* in NYC 🥶

  • @lazbuza
    @lazbuza 4 роки тому +1

    Nagen, thank you so much for your informative video. You helped me fix my problem.

  • @larrykornstadt1241
    @larrykornstadt1241 3 роки тому +1

    Thank you so much, wish I could buy you a beer, appreciate your sharing this. Merry Christmas my friend

  • @dphillie123
    @dphillie123 4 роки тому +1

    Life saver! Worked like a charm!

  • @DrMidknight
    @DrMidknight 4 роки тому +1

    Nice video. My pressure switch was bad. I will note this for future repairs.

  • @rocky1266
    @rocky1266 4 роки тому +4

    Worked for me as well, thank you!!!!

  • @CJDowling777
    @CJDowling777 4 роки тому +1

    This was exactly my issue, thanks muchly!

  • @SoulSeeker770
    @SoulSeeker770 4 роки тому +2

    Oh my goodness!! You are lifesavers!! Thank you SOOO much!!
    It stopped working with 3 red light flashing.
    Cause:
    • Pressure switch hose blocked, pinched or connected improperly.
    I checked.. nothing wrong.
    • Blocked flue and/or inlet air pipe, blocked drain system, or weak induced draft blower.
    I have no idea what or where these are or the next two points. If any of you have an Amana Furnace and know, please help.
    • Incorrect pressure switch setpoint or malfunctioning switch contacts.
    • Loose or improperly connected wiring.
    Corrective steps:
    Inspect pressure switch hose. Repair, if necessary,
    • Inspect flue for blockage, proper length, elbows, and termination. Correct as necessary.
    • Correct pressure switch setpoint or contact motion.
    • Tighten or correct wiring connection.

  • @seanjfk1
    @seanjfk1 4 роки тому +3

    Thank you soooo much for this video!

  • @Quejuans
    @Quejuans Рік тому

    Saved me some money. Somehow a baby bat got lodged in the motor and was blocking everything up. Clean it out and furnaces fired right back up

  • @dezzyd1
    @dezzyd1 4 роки тому +1

    Thank you! Thank you! This was a quick and easy fix!!

  • @frankborja1403
    @frankborja1403 2 роки тому +1

    Thank you very much thanks to your video today I was able to fix my furnace just as you stated in this video

  • @Death_Row_Anglers
    @Death_Row_Anglers 3 роки тому +1

    PROBLEM SOLVED! Thank you! I had the same problem that you did. I just subscribed to your channel. Thanks again 👌🏾

  • @ejflesher
    @ejflesher 9 місяців тому

    This fixed my issue. Thank you so much

  • @Honestandtruth
    @Honestandtruth 4 роки тому +3

    Thanks you for sharing. Good people will always Help others..👍💟👍

  • @alienatedyouth7errr
    @alienatedyouth7errr 4 роки тому +1

    Thank you so much this helped a lot!!

  • @Katz69cristian
    @Katz69cristian 4 роки тому +1

    Thank you for your video. It helped me fix my unit.

  • @thomast6096
    @thomast6096 4 роки тому +1

    That worked for me!! Thank you SO Much!!!

  • @MrPiratachido
    @MrPiratachido 4 роки тому +2

    I like your video it help me a lot and save me money thank you my friend

  • @d.ppineda4487
    @d.ppineda4487 2 роки тому +1

    Thank you for your help

  • @danoblelaw33
    @danoblelaw33 4 роки тому +2

    F'n AWESOME>>>>>>>> THANK YOU THANK YOU

  • @aaronrodden8121
    @aaronrodden8121 Рік тому +1

    This worked for me but after a year, the inducer motor started not coming on until I tapped the control board a few times with power off then turning power back on. I'm working on that issue as we speak.

  • @mikestein1024
    @mikestein1024 3 роки тому +2

    God bless you sir !!!!

  • @youngmultac
    @youngmultac 5 років тому +4

    thanks a ton

  • @513goldybaby
    @513goldybaby 3 роки тому +1

    Thanks 👍 it's 23 degrees out side and feel like -10 inside watch this video and now it feels like 76 on the beach ⛱️. Thank you A++

  • @carterbersano3475
    @carterbersano3475 Рік тому

    THANK YOU! This was exactly the problem!

  • @sandlertossone1813
    @sandlertossone1813 4 роки тому +2

    You are the man. Thanks soooo much I was freezing my butt off lol

  • @jefferycoles4813
    @jefferycoles4813 2 роки тому

    Thank you so much. Greatly appreciated

  • @lel70schildofthemosthigh71
    @lel70schildofthemosthigh71 Рік тому

    Thanks soooo much it helped me out as well !!! Saved me the service call !!!!

  • @carlossantos252525
    @carlossantos252525 4 роки тому +1

    Man you save me $ tnks for the video I did just that and it works fine now kids are happy and wife is no bothering any more 😃

  • @elprimojales5704
    @elprimojales5704 3 роки тому +1

    TY!!!

  • @minee4009
    @minee4009 4 роки тому +1

    Thank you so much!!! It works for me . God bless 😇😇

  • @thetruckandi
    @thetruckandi 2 роки тому

    7
    Extremely helpful!

  • @rocbrar
    @rocbrar 3 роки тому +1

    Thank you!

  • @ivancarrillo9048
    @ivancarrillo9048 4 роки тому +1

    Thank you so much you saved me alot money I did the same and it worksssss

  • @Triceptor78
    @Triceptor78 3 роки тому +1

    Thank you!!!

  • @bradleycole5079
    @bradleycole5079 Рік тому +1

    You literally just saved me and my family hundreds!!! And on Christmas Night!! Thank you very much!!!

  • @woodlandxwarrior
    @woodlandxwarrior 2 роки тому

    Thanks brother. I did not confirm if this is the issue just yet, but I've already kinds looked at the system, and are having the same issues. Error code 3: PS switch stuck open. I'll check it now.

  • @BillyO8828
    @BillyO8828 4 роки тому +5

    Thank you, thank you, thank you! May God Almighty bless you for this video!!!

  • @Woke1440
    @Woke1440 4 роки тому +1

    Better clean those burners 👍🏼👍🏼👍🏼

  • @7oriole7
    @7oriole7 7 місяців тому

    Thankyou much

  • @armageddon890
    @armageddon890 5 років тому +4

    What gunk are u referring to?

  • @HungNguyen-sb1yu
    @HungNguyen-sb1yu 5 місяців тому

    I have a comfort maker furnace. Where can I find the tiny hole? Thank you.

  • @isisyrafaelito3453
    @isisyrafaelito3453 5 років тому +3

    thanks indian man!!!

  • @jjhatnm
    @jjhatnm Рік тому

    My lights flash red three times just like that, but their is NO noise from the motors/fans like you hear. Mine is silent. What does that mean?

  • @sharonmanetta7685
    @sharonmanetta7685 Рік тому +1

    Where did you find that switch

  • @kevinswaney5875
    @kevinswaney5875 2 роки тому

    Hi, I was hoping you could give me some advice. My parents had a new Amana furnace 6 roller (model AMES801205DX installed. Unfortunately they continued to have problems with it. The seller admitted they installed too big of a furnace for their house and replaced it with a Goodman 3 roller (model AMES800604BXAA). They did not receive any refund for the price difference. My dad has dementia and my mom has Parkinson. I think the company took advantage of them, but I can't find the prices for the furnaces. Any feedback you could provide would be greatly appreciated.
    Thanks,
    Kevin

  • @eddymumford4086
    @eddymumford4086 Рік тому +1

    Does anyone's Goodman furnace ever flash a number 2 when running only when it's running 🤔 mine dose but I never see anyone else's I watched a lot of videos... maybe mine is the only one 😁

  • @brandenjordan659
    @brandenjordan659 5 років тому +2

    I have the same one, but what kond of fan should I get

    • @nagenem5530
      @nagenem5530  5 років тому

      Branden Jordan is fan not working?

  • @moecapitolnetwork2916
    @moecapitolnetwork2916 2 роки тому

    In my case it was a clogged filter

  • @blueg3027
    @blueg3027 4 роки тому +1

    Not sure why you had to pull the inducer lol just check your pressures with your manometer. Waste of time and money for your customer

    • @Nagenmaha
      @Nagenmaha 4 роки тому +2

      Jordan G I didn’t have manometer, just to let you know that was my first time opening HVAC unit

  • @sonGOKU._.
    @sonGOKU._. Рік тому

    This error code is the worst 😢

  • @kennethdandurand3472
    @kennethdandurand3472 2 роки тому +1

    Turn your voice up..... you are whispering.

  • @HenryBloggit
    @HenryBloggit 2 роки тому

    Can’t hear a word you say

  • @df56gh4d5h
    @df56gh4d5h 5 років тому +2

    Speak up man I can't hear you!

    • @nagenem5530
      @nagenem5530  5 років тому +2

      Jim W sorry Jim it was not well planned , perhaps next time

    • @sabbasdsouza
      @sabbasdsouza 5 років тому +1

      I just turned up the speakers. It was clear enough on my TV, difficult to hear on the phone. It really helped me.

    • @Honestandtruth
      @Honestandtruth 4 роки тому

      That's what the volume button is for and Everyone got One. This is to Jim W.

  • @minee4009
    @minee4009 4 роки тому +1

    Thank you so much!!! It works for me . God bless😇😇