ulka pump repair clean test USE GFCI safety outlet ONLY FOR TEST!!

Поділитися
Вставка
  • Опубліковано 5 вер 2024
  • ulka pump repair clean test, réparation nettoyage teste pompe ulka
    USE GFCI safety outlet ONLY FOR TEST!!!USE GFCI safety outlet ONLY FOR TEST!!!USE GFCI safety outlet ONLY FOR TEST!!!USE GFCI safety outlet ONLY FOR TEST!!!USE GFCI safety outlet ONLY FOR TEST!!!USE GFCI safety outlet ONLY FOR TEST!!!USE GFCI safety outlet ONLY FOR TEST!!!USE GFCI safety outlet ONLY FOR TEST!!!

КОМЕНТАРІ • 53

  • @Frederick-sg2dc
    @Frederick-sg2dc 5 років тому +2

    Found this machine a 2003 in Goodwill $9.99. Your video saved this machine. Thank you. 08/23/19

  • @WestleyThayer
    @WestleyThayer 5 років тому +14

    You might want to add a disclaimer that it's not your fault if people are crazy enough to test the pump as you did with a bare wire with 120vac and water...

  • @yorkynmak
    @yorkynmak 2 роки тому +2

    good demonstration for repair step but the way how you tested it is dangerous. Easy to be electrically shocked.

  • @jumaljuma
    @jumaljuma 2 роки тому

    Good job 👏

  • @cfcreative1
    @cfcreative1 5 років тому +1

    I have the Starbucks machine and it has the 52w pump and the plastic tube instead of copper. I find that the main problem I have is the metal plate where the water flows into the portafilter that gets gunked up. I took the pump apart and it looked like new. I have been using it maybe 5 years now.

  • @AliHassan-tk8pt
    @AliHassan-tk8pt 6 років тому

    Thank you so much for saving my money. Its work

  • @roconzhen
    @roconzhen 8 років тому +2

    loosen the screw plastic part holding the tension of the ball valve.(check valve) dismantle the vibration pump motor.blow the fitting.if you blow it easily that mean the pressure is more that 14.7 psi.this very good.you can use petroleum jelly if you don't have vacuum grease (food grease) the 4 O-rings,specially the 2 O-rings outside.should be leak free (thin and big).tighten the screw.the exist jelly shield the leaked Do actual test.block your finger the water output. pressure should strong.when do assembling use additional washer.to increase the gap (the screw plastic part) keep in record the coil resistance. new vs old for a reference.

  • @rogiervdheide
    @rogiervdheide Рік тому

    Whether or not your outlet has a fuse (GFCI safety outlet) it is nuts to "test" this way. All that water around, you with your sleeves rolled up, a metal sink, and than a free hanging and swinging cable with a copper end live 110V or 220V...

  • @efrainespino8227
    @efrainespino8227 Рік тому

    No recibe corriente la bomba directa si trabaja

  • @kfalqueto
    @kfalqueto 6 років тому +1

    Thanks a lot!

  • @floresmiromoreno9850
    @floresmiromoreno9850 2 роки тому

    Donde puedo adquirir los repuestos para esta bomba
    Les escribo desde Miraflores Boyacá Colombia. Floresmiro Moreno. Espero su respuesta. Saludos

  • @phillipzx3754
    @phillipzx3754 3 роки тому +1

    I'd have thought the pump would work a bit harder than that. I have a Delonghi EC680 with that pump (I think) that seems pretty low on pressure. They say it has 15 bar of pressure (or about 200 PSI). That pump doesn't look like it's doing much work.
    If all it needs is to be taken apart for a good cleaning, that would be nice. A new pump is about $25 U.S.

  • @johnmitchell3719
    @johnmitchell3719 3 роки тому

    Nice music

  • @vincenzocaccia9777
    @vincenzocaccia9777 2 роки тому

    Hello . how does he pump water ?? what is its functioning? can you explain?

    • @rogiervdheide
      @rogiervdheide Рік тому

      It's a magnetic coil that moves a piston back and forth. Valves make sure that the water flows in one direction.

  • @capistranjona
    @capistranjona 5 років тому

    Hi, thanks for the video. Is there a correct way to connect the line and the neutral in the pump? or it doesn't matter?

  • @loliyera8221
    @loliyera8221 7 років тому +3

    como puedo poner laluz verde

  • @shlomovenezia101
    @shlomovenezia101 6 років тому +1

    less music more pump sound next time for more professional - gracias

  • @danbirzac7224
    @danbirzac7224 5 років тому

    why my coffee machine delonghi magenta ESAM 3200
    grind coffee but it does not flow
    what a defect it may be
    I made 2-3 cleanings and it worked
    but the coffee does not come in the cup after it is ground
    it has the water pump identical to the one in the video

    • @peterv6036
      @peterv6036 4 роки тому

      Replace the pump and it'll be fine 9 out of 10 times

  • @Aimopotis
    @Aimopotis 5 років тому

    Hello do you have any suggestions on how to make Gaggia classic pump less noise

    • @phillipzx3754
      @phillipzx3754 3 роки тому

      www.chriscoffee.com/products/pulsor-for-qm67

  • @yrulooknatme
    @yrulooknatme 8 років тому +1

    and make sure u plug into a working gfci outlet!!

  • @Ardunil
    @Ardunil 6 років тому

    can this pump work continues?

    • @caronalexis
      @caronalexis  6 років тому

      Will probably burn electric coil or fast wear , use in espresso machines for small time.

    • @peterv6036
      @peterv6036 4 роки тому +1

      Ulka Ex5 and Ep5 specifications: maximum 2 minute on/ 1 minute off cycle

  • @ours02
    @ours02 7 років тому

    pas besoin de graisser ou de changer certains joints? juste un nettoyage?

    • @caronalexis
      @caronalexis  7 років тому

      nilbtoulouse pas vraiment nécessaire selon moi!! mais c'est possible donc attention a en prendre une qui n'est pas toxique

    • @ours02
      @ours02 7 років тому

      bon j'ai bien tout démonté (j'ai une EP5), nettoyé les parties plastiques et remonté. la pompe fait un bruit correct, mais n'aspire rien du tout...merci du tuto en tout cas.

    • @caronalexis
      @caronalexis  7 років тому

      testé vous de la même façon que moi? le circuit doit être ouvert pour pouvoir charger la pompe en eau!! Sinon assurez-vous de pas avoir inversé un des petits valve(ressort)

    • @caronalexis
      @caronalexis  7 років тому

      sur cette page web une image(tranché) pourra peut être vous être utile www.home-barista.com/repairs/repairing-ulka-vibratory-pump-t1079.html

  • @DrTarekReda
    @DrTarekReda 7 років тому

    can you do the same with gaggia classic? as my machine stopped dripping

    • @caronalexis
      @caronalexis  7 років тому

      Dr. Tarek Reda same pump!!! test pump freely before!!! gaggia aluminium boiler clog easy!!!!! good luck :)

    • @DrTarekReda
      @DrTarekReda 7 років тому

      thank you :)

  • @benjaminmaraz4981
    @benjaminmaraz4981 6 років тому +5

    Safety first :D (last)

  • @salvagedsteelstudio
    @salvagedsteelstudio 4 роки тому +2

    Make sure your life insurance is up to date before deciding to try this fix.

    • @whazzat8015
      @whazzat8015 2 роки тому

      No fake.
      dumb as they come,
      leaning on the sink holding bare wire

    • @rogiervdheide
      @rogiervdheide Рік тому

      I don't think it would pay out when do like in the video

    • @caronalexis
      @caronalexis  10 місяців тому

      hahaha GFCI plug guy.....

  • @rowopie
    @rowopie 9 років тому

    What is the music please ?

    • @caronalexis
      @caronalexis  9 років тому

      +rowopie
      Don't Look
      Silent Partner

    • @caronalexis
      @caronalexis  9 років тому

      +alexis c don't look silent partner

  • @rclr0
    @rclr0 8 років тому

    I think that pump isn't work properly. Its stream is poor

    • @caronalexis
      @caronalexis  8 років тому +1

      +RAFAEL CARLOS LEDESMA RUS Ulka pump flow is very low, average flow is 400ccMin!!! use all day this pump on my starbuck barista. :)
      www.google.ca/search?q=ulka+pump+flow+rate&espv=2&biw=1280&bih=655&site=webhp&source=lnms&tbm=isch&sa=X&ved=0ahUKEwiizYPQ2b3KAhVkuYMKHd7jAMwQ_AUIBigB#imgrc=Lli6ei-17PRWYM%3A

    • @rclr0
      @rclr0 8 років тому

      ok, thank for your explanations from Spain. Excellent video.

    • @caronalexis
      @caronalexis  8 років тому

      with pleasure!