Oooh u r using oly normal wires for all the site ah... So u quote your rate low boz u install just wires instead of armored cable for all the site... 1. Use oly 2 core 1.5 sq mm Cooper armored cable. 2. MCP means Manual call point 3. Y using oly 4 hooters for NAC 1... arhuku mala use panina yanna agum sound varatha 4. Imp point - y resistance r using in opp end... Panel side la resistance use panina panel vadichiruma..... 5. No nc la yatho wire irundha mathiri thariuthu atha yaan expalin panala.... Yaan athu yathukuna thariyalaya.... 6. Starting sonna mathiri convention addressable and ithu mathiri naraya irukunu sonniga... Innu yanna yanna model irunku konjam expain pannuga pakalam I think u r election oly you taking electrical contract also with fire... U r not a fire alarm integrator...
I m not fire alarm technician. I m electrician. Here we are laying the wires in separate shaft through pipes. So cable is not required. Then cable needs more space.
Good demo thankyou bro
Bro ithu conventional la thane
Apram one zone la ethna devices fix pannuvinga
Clear explanation... Thanks...
Super machii👍👍
Thank you so much for you 🙏
Sir veelaiku varlama
Certificate course ethana irukaa Elv technician akarathuku?? Pls reply
Bro manual call points termination mistake pannuna device problem akuma
How to adda external supply of the hotters are not activating continuously
Sorry bro. Puriyala
Bro course padicha worthble ah bro
அண்ணா .Co panel ஏப்படி c சோல்லவும் please
Fire fighting commissioning video podunga
Super Anna
Super
Tq❤
Bro , hooter connection mattum puriyala
Fire Alarm technician job available sir
What is the use resistor capacity..bro
1k
Sir jobs available sir iam fire alarm technician
What different Addressable vs Convesational
Addressable is hard to maintain , conventional is easy to maintain
Bro oru doubt telegram contact kudunga bro voice message la kekanum
No telegram, Instagram - graduate electrician
@@graduateelectrician4619 ok bro message panren
what is the wire gauges
Thanks for your comment, we used 1sqmm wire
Hi Bro one douted
Ravel 12 zone panel how to connect Hooters MCP and detectior
Addressable or conventional
Panel detail sollunka
Ravel
Bro types of fire alarm sollunga pls
Addressable, conventional.... Main types using in India. Inum 2 more types iruku. Please check in Google
More videos
Please reply pannunga
Device fault agadhu, but work agadhu. Sorry for late reply
Appuram termination correct aha pannuna ok akiruma
@@graduateelectrician4619 thanks for replying
First time work pannuren device unaccepted varuthu
S
Hi
Oooh u r using oly normal wires for all the site ah... So u quote your rate low boz u install just wires instead of armored cable for all the site...
1. Use oly 2 core 1.5 sq mm Cooper armored cable.
2. MCP means Manual call point
3. Y using oly 4 hooters for NAC 1... arhuku mala use panina yanna agum sound varatha
4. Imp point - y resistance r using in opp end... Panel side la resistance use panina panel vadichiruma.....
5. No nc la yatho wire irundha mathiri thariuthu atha yaan expalin panala.... Yaan athu yathukuna thariyalaya....
6. Starting sonna mathiri convention addressable and ithu mathiri naraya irukunu sonniga... Innu yanna yanna model irunku konjam expain pannuga pakalam
I think u r election oly you taking electrical contract also with fire... U r not a fire alarm integrator...
I m not fire alarm technician. I m electrician.
Here we are laying the wires in separate shaft through pipes. So cable is not required. Then cable needs more space.
2. MCP is manual call point. One or two times I told manual control point. Sorry for that.
3. We are using wires, 4 hooters enough.
4. If the resistance are connected in panel end, you are getting fault signal.
5. Theriyala. Sollunga therinjikren.
Super anna
Super machii👍👍