Lecture Series on Design of Steel Structures by Dr.Damodar Maity, Department of Civil Engineering, IIT Guwahati. For more details on NPTEL visit nptel.iitm.ac.in
Solution of design of builtup section ISA at 00:34:50 in video is wrong... i guess. Rmin= 16.9 is taken/said for individual section rather it should have been for quivalent builtup section .... Please clarify
See, To understand steel design as per IS 800:2007, follow Rammarutham and S.K. Duggal book. They are the best. As an experienced academician, I will surely suggest those 2 books first.
now we are using is 800 2007...so ans may be different?
Anita Dhami yes
I do got the same doubt
Solution of design of builtup section ISA at 00:34:50 in video is wrong... i guess.
Rmin= 16.9 is taken/said for individual section rather it should have been for quivalent builtup section ....
Please clarify
See, To understand steel design as per IS 800:2007, follow Rammarutham and S.K. Duggal book. They are the best. As an experienced academician, I will surely suggest those 2 books first.